Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance NO 127 UGRAPPA BUILDING 5TH E CROSS BALLERY ROAD BYATARAYANAPURA BENGALURU BANGALORE KARNATAKA 560092 | BENGALURU URBAN | KARNATAKA | 560092 | Admitted-Finance |
Tender Value
₹2.4 L
Closing Date
22 Sept 2021, 4:00 pmClosed
EE(E), BSNL ED-II
BSNL Electrical Division 2, WMS Compound, 47th Cross, 9th Main, 5th Block, Jayanagar, Bengaluru560 041
Dismantling and Tr of 8x1.5 TR SAC from different TE Bldgs, ITC of SAC Units, Wiring and associated Works for Replacement of PAC at TE PEENYA, Bengaluru
2021_BSNL_88144_1
16/2021-2022/BSNL/ ED-II/ BGL
Open Tender
Electrical Works
Item Rate
30 days
TE PEENYA BENGALURU
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts Officer (Cash), HQ, BSNL, BGTD
Exempted
30 Sept 2021
14 Sept 2021
24 Sept 2021
14 Sept 2021
22 Sept 2021
14 Sept 2021
14 Sept 2021 - 22 Sept 2021
Amount
3 Nos 7TR Package AC Units at TE PEENYA
Dismantling the existing 1.5 TR spilt AC units i/c indoor/ outdoor unit, refrigerant piping, etc at different TE buildings under Bengaluru urban area, along with stabilizers without damaging the units i/c arranging necessary T&P, manpower, etc as reqd. Tentative buildings for dismantling: Gudemaranahalli (2), Thippasandra (2).
Transportation of dismantled 1.5 TR spilt AC units i/c indoor/ outdoor unit, with all accessories and stabilizers etc from different BTS sites under BGTD, to TE PEENYA (up to a distance of 60 kms for Gudemaranahalli and Thippasandra) without damaging the units i/c shifting the units from different floors, loading and unloading with necessary manpower, etc as reqd.
ITC of 1.5 TR Spilt AC units along with indoor and outdoor units , laying of recovered copper piping, making opening in wall and making good the damages, including checking the connections, PCB's, motors, general servicing of the unit etc reqd.
S/L of extra copper refrigerant pipe both hot gas line and liquid refrigerant lines of suitable size respectively I/c brazing, etc as reqd.
S/F of powder coated heavy duty iron Stand for mounting outdoor units of the above AC i/c providing necessary hardwares, etc as reqd.
Supplying and laying 50 mm Rigid/flexible PVC pipe with accessories for protection of refrigerant piping including clamping etc as required
Supplying and laying 20 mm Rigid PVC pipe with accessories for drain piping including clamping etc as required
S/L 3 core 2.5 sqmm PVC insulated PVC sheathed copper conductor cable in the existing conduit including connections etc as required
Supplying and charging additional refrigerant gas suitable for existing split AC unit, including transportation etc as required
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed conduit/Truf as required. 2x4 sq. mm + 1x4 Sqmm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed conduit/Truf as required. 4x4 sq. mm + 2x4 Sqmm earth wire
Supplying and fixing of 20 mm dia medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 25 mm dia medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing 5A to 32A rating, 240V, 10 kA, “C” curve, SINGLE POLE miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required (M/s Indoasian/Hager or s/s make)
Supplying and fixing 25 A, 2 Pole Changeover MCB suitable for operation on 240V 1 Ph AC supply in the existing MCB DB complete with connections, testing and commissioning etc. as required (M/s Indoasian/Hager or s/s make)
Supplying and fixing 2 Way MCB Distribution board suitable for operation on 240V 1 Ph AC supply on surface of wall, complete with connections, testing and commissioning etc. as required (M/s Indoasian/Hager or s/s make)
S/F factory fabricated M.S sheet steel enclosure suitable for 2 way MCB including supplying and fixing 1 No. 20 A SPNMCB, necessary interconnections etc as reqd.
S/F of 12mm thick plywood sheet i/c suitable nut bolt for closing of existing opening including cutting the sheet to required shape, making good the damages etc., as reqd
Supplying and Fixing of Running capacitors suitable for 1.5 TR AC Units including dismantling faulty spares etc as required.
Supplying and Fixing of control PCB suitable for 1.5 TR AC Units including dismantling faulty spares etc as required.
Supplying and Fixing of Indoor/outdoor motor suitable for 1.5 TR AC Units including dismantling faulty spares etc as required.
S/F of the following electrical accessories on surface of wall including making necessary interconnections, testing, commissioning, etc as reqd. (a) 450 mm Heavy duty Pedestal Air Circulator (M/s Almonard or SS make)
S/F of Fiber type Fan blade suitable for 1.5 TR Split AC outdoor unit with necessory hardware items i/c dismantling faulty, testing etc., as reqd.
S/F 63A, 4 Pole TPN MCB suitable for operation on 415V AC supply in the existing MCB DB complete with connections, testing and commissioning etc. as required (M/s L&T)
AGNES ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .