Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹30.0 L+₹6.0 L (25.2%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹32.5 L+₹8.5 L (35.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹32.6 L+₹8.7 L (36.2%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹32.8 L+₹8.9 L (37.0%)Rejected-Finance 499 A VIDHYUT NAGAR A AJMER ROAD JAIPUR 302021 | JAIPUR | JAIPUR | RAJASTHAN | 302021 | L5 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | M/S Anil Enterprises L1 | SHREE BHAGWATI ENTERPRISES L2 | DIVYA ASSOCIATES L5 | S.R.Enterprises L3 | LAKSHMI ASSOCIATES L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables errection of poles / struts/stays etc n.exe 10 Sqm on plan not exceeding 1.5 metre in depth and getting out in any type of soil. | 100 | Cum | 80 ₹8,000 Lowest | 125 ₹12,500 | 130 ₹13,000 | 90 ₹9,000 | 111 ₹11,100 |
| 2.00 | Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point | 33 | Cum | 50 ₹1,650 | 50 ₹1,650 | 50 ₹1,650 | 40 ₹1,320 | 21 ₹693 Lowest |
| 3.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in any type of soil. | 67 | Cum | 40 ₹2,680 | 50 ₹3,350 | 30 ₹2,010 | 40 ₹2,680 | 21 ₹1,407 Lowest |
| 4.00 | Supplying and laying un-reinforced precast cable covers class HV, type I, flat, size 300mm x 180mm x 40mm. | 1,390 | Each | 20 ₹27,800 Lowest | 30 ₹41,700 | 25 ₹34,750 | 25 ₹34,750 | 29 ₹40,310 |
| 5.00 | Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables complete all as specified. | 23 | Cum | 1,000 ₹23,000 | 250 ₹5,750 Lowest | 500 ₹11,500 | 250 ₹5,750 Lowest | 300 ₹6,900 |
| 6.00 | M&L Disc type insulator, Porcelain, vitreous brown, white or green single disc assembly, 145mm high & 255mm dia ball & socket type, for tension clamps for conductors, working pressure 11000 volts including taking down/dismantling old item. | 6 | Each | 100 ₹600 Lowest | 300 ₹1,800 | 500 ₹3,000 | 1,100 ₹6,600 | 450 ₹2,700 |
| 7.00 | M&L Pin type, porcelain, vitreous brown, white or green insulator (HT), 150mm height and 150 mm dia, 11000 volts grade including one galvanised MS spindle, two GI washers and one GI nut complete | 12 | Each | 100 ₹1,200 Lowest | 156 ₹1,872 | 300 ₹3,600 | 250 ₹3,000 | 180 ₹2,160 |
| 8.00 | Supply and fix lightening arrestor expulsion type complete with all fittings transmission class discharge capacity 65 KA suitable for 11000 volts including taking down/dismantling old item. | 4 | Each Set | 2,000 ₹8,000 Lowest | 3,000 ₹12,000 | 4,000 ₹16,000 | 3,500 ₹14,000 | 3,900 ₹15,600 |
| 9.00 | Supply & Fix Air break switch 200 amp, for HT 11 KV, 50 Hz AC, Gang Operated, triple pole, outdoor, horizonal / vertical mounting type (ISI marked), mounted on insulators and MS frame work, with fuse carriers & HT fuses, manually operated from ground level with locking arrangment including 65 mm pad lock with two keys, necessary electric connections, taking down old item complete all as specified and directed by Engineer-in-Charge. | 9 | Each | 12,000 ₹1,08,000 Lowest | 15,800 ₹1,42,200 | 14,000 ₹1,26,000 | 14,500 ₹1,30,500 | 12,000 ₹1,08,000 Lowest |
| 10.00 | Supply & Fix, fixed contact of Brass Alloy single pole including fastners suitable for air break gang operated switch of cap 200/400 amp 3 pole 11000 volts grade including taking down/dismantling old item. | 8 | Each | 100 ₹800 Lowest | 300 ₹2,400 | 400 ₹3,200 | 900 ₹7,200 | 210 ₹1,680 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
27 Mar 2026, 6:00 pmClosed
CWE JAIPUR
Military Engineer Services, HQ Commander Works Engineer, KalyanMarg, Banipark, Jaipur-06
REPAIR AND MAINT OF 11 KV NETWORK INCLUDING TRANSFORMER, SWITCHGEAR AND CONNECTED ACCESSORIES AT ZONE-III AREA UNDER GE (S) JAIPUR
2026_MES_751072_2
82534/JPR(S)/E8
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH JAIPUR
AS PER NIT
6 documents required · 6 mandatory
₹500
GE (S) JAIPUR
₹60,000
Yes
HQ CWE JAIPUR
29 May 2026
6 Mar 2026
30 Mar 2026
6 Mar 2026
27 Mar 2026
21 Mar 2026
13 Mar 2026
Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables errection of poles / struts/stays etc n.exe 10 Sqm on plan not exceeding 1.5 metre in depth and getting out in any type of soil.
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in any type of soil.
Supplying and laying un-reinforced precast cable covers class HV, type I, flat, size 300mm x 180mm x 40mm.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables complete all as specified.
M&L Disc type insulator, Porcelain, vitreous brown, white or green single disc assembly, 145mm high & 255mm dia ball & socket type, for tension clamps for conductors, working pressure 11000 volts including taking down/dismantling old item.
M&L Pin type, porcelain, vitreous brown, white or green insulator (HT), 150mm height and 150 mm dia, 11000 volts grade including one galvanised MS spindle, two GI washers and one GI nut complete
Supply and fix lightening arrestor expulsion type complete with all fittings transmission class discharge capacity 65 KA suitable for 11000 volts including taking down/dismantling old item.
Supply & Fix Air break switch 200 amp, for HT 11 KV, 50 Hz AC, Gang Operated, triple pole, outdoor, horizonal / vertical mounting type (ISI marked), mounted on insulators and MS frame work, with fuse carriers & HT fuses, manually operated from ground level with locking arrangment including 65 mm pad lock with two keys, necessary electric connections, taking down old item complete all as specified and directed by Engineer-in-Charge.
Supply & Fix, fixed contact of Brass Alloy single pole including fastners suitable for air break gang operated switch of cap 200/400 amp 3 pole 11000 volts grade including taking down/dismantling old item.
Supply & Fix, moving contact of Brass Alloy single pole including fastners suitable for air break gang operated switch of cap 200/400 amp 3 pole 11000 volts grade including taking down/dismantling old item.
Supply & Fix, flexible Copper strip including fastners suitable for air break gang operated switch 200/400 amps 11000 volts for single phase including taking down/dismantling old item.
M&L for shifting of transformer of any capacity from any location within the station to location of defective transformer and connecting with HT 11 KV incomer from existing source and LT outgoing cables complete as directed by Engineer-in-Charge.
M&L for disconnecting and dismantling including handling and transportation of defective transformer, any type, 63 KVA to 125 KVA, 11 KV/433 V, copper/ Aluminium wound, opening the transformer, safe draining of tranformer oil for reuse, removing all burnt particles i.e tape, paper insulating strings etc gently and carefully, washing of the dust, rust and dirt from all parts including HT/LT coil, core tank and cooling tubes, painting the inner side of tank by zinc chromate paint and preparing the same for re-assembling after carrying out required repairs, re-assembling and re-installation, including connecting up electrically, commissioning at site all as directed by Engineer-in-Charge. Note :- 1.Repair cost is deemed to be included in the quoted rate; and Unsv items required to be replaced shall be measured and paid separately. 2.The burnt transformer oil will be contractor property & any new oil will be measured and paid seperatly under respective item. 3. The coils and the oil shall be inspected for repair/replacement by department rep.
-ditto- but 150 KVA to 250 KVA capacity
-ditto- but 315 KVA to 400 KVA capacity
Supply only copper coil with suitable insulation for copper wound transformer of any type/capacity for following (i) HT Coil
(ii) LT Coil
Supply only HT porecelain bushing complete with brass/tinned copper rod with nuts and gasket set complete for 63 KVA to 125 KVA capacity transformer.
-ditto- but 150 KVA to 250 KVA capacity
-ditto- but 315 KVA to 400 KVA capacity
Supply only LT porecelain bushing complete with brass/tinned copper rod with nuts and gasket set complete for 63 KVA to 125 KVA capacity transformer.
-ditto- but 150 KVA to 250 KVA capacity
-ditto- but 315 KVA to 400 KVA capacity
S&F in replacement of breather of transformer with silica gel complete with end fitting as per existing size and shape as directed by Engineer -in-Charge
M&L for Painting of transformer 63 KVA to 125 KVA applying two coats of synthetic enamel paint of grey colour by spraying complete including preparation of old surfaces, removing & cleaning of oil/grease all as specified and directed by Engr in Charge.
-ditto- but 150 KVA to 250 KVA capacity
-ditto- but 315 KVA to 400 KVA capacity
M&L for refilling fresh Silica Gel into the breather including removal of old item.
M&L for boring of existing road/path for laying of GI pipe Size 100mm dia protection for UG cable including making good distrurbed area/surface all as specified and directed.
Supply & fixing or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles / walls under road crossing etc of size 100 mm bore including dismantling & taking down existing pipe.
M&L for calibration and testing of protection relay of any make or type fitted on 11 KV 4 Way RMU as per IS and code of practice to insure NO ERROR including setting for each fault over current with trip time delay in accordance to feeder load and other parameters of site including grading with incomer panels at MRS. Servicing complete with decarbonizing the contact points, cleaning with CRC solution etc. All indicating lamp of the panel replaced if necessary, breaker control switch, digital Amp meter, Volt meter should be replaced if in case found defective, testing after repair complete all as directed by Engineer-in-Charge of any make and type. Note:- Servicing will be done twice at the duration twice in duration of contact and this will be considered as one job.
M&L for calibration and testing of protection relay of any make or type fitted on 11 KV 6 Way RMU as per IS and code of practice to insure NO ERROR including setting for each fault over current with trip time delay in accordance to feeder load and other parameters of site including grading with incomer panels at MRS. Servicing complete with decarbonizing the contact points, cleaning with CRC solution etc. All indicating lamp of the panel replaced if necessary, breaker control switch, digital Amp meter, Volt meter should be replaced if in case found defective, testing after repair complete all as directed by Engineer-in-Charge of any make and type. Note:- Servicing will be done twice at the duration twice in duration of contact and this will be considered as one job.
Disconnecting of HT supply from 11 KV VCB of any capacity of Amps for overhauling of mechanism trolly and carry out repair works, servicing complete with decarborizing the contact points, cleaning with CRC solution tightening springs greasing etc etc testing after repair complete all as directed by Engineer-in-Charge. Make of VCB AREVA/ ALSTOM/ CG Note:- Parts replaced in VCB shall be measured and paid separately under respective item.
M&L for Disconnecting of HT supply from 33 KV VCB/SF 6 CB-4 Nos with panel capacity of 1250 Amp outdoor type for overhauling of mechanism and carry out repair works, servicing complete with decarburizing the contact points, cleaning with CRC solution etc testing after repair complete all as specified and directed Note:- Servicing will be done twice at the interval of 3 months and this will be considered as one job. Note:- Parts replaced of VCB shall be measured and paid separately under respective items.
M&L for testing of CT and PT and its oil level of any make or type fitted in 33 KV switchyard (details given below) as per IS and code in accordance to feeder load and other parameters of site including grading with incomer panels at MRS (a) Out going / Incoming 33 KV- 05 Nos (b) Testing and tightening of bus bar of 33KV switchyard alongwith testing of insulators of 33kV from Incomer to the VCBS of 11KV (c) Checking and testing of insulators of 33 KV swithcyard complete. NOTE: (i) The testing and setting must be completed with in 3 weeks from the date of commencement placed to avoid major break down. (ii) The testing and setting shall be carried out by only qualified and experienced engineer. (ii) The testing includes comprehensive testing from the supply received at Combined CT PT to the incomer of the Power transformers (v) Certificate/report of rep of authorised person should be submitted after testing the CT and PT. The record of testing/ setting of CT and PT and Switchyard of 33KV shall be submitted by the Contractor.
Replacement of following parts for item No 32 to 35 above :- Supply only Ratchet wheel Assembly with Ratchet pin suitable for 11 KV VCB
Supply only Shunt Trip Coil, operating voltage 24 Volts DC suitable for 11 KV VCB/ SF6 gas breaker.
Supply only digital type multifunctional meter with Ammeter/Volt Meter for 11 KV VCB.
S&F Anti-pumping relay 2NO+2NC, 24V DC, 6 Amp.
Supply only Closing coil, operating voltage 24 Volt DC suitable for 11KV VCB/SF-6 gas breaker.
Supply only triping coil assy suitable for 11KV VCB.
Supply only small gear assy with motor shaft suitable for 11 KV VCB.
S&F Auxillary contactor for contact multiplication 7NO+7NC, 24V, DC, 6 Amp.
Supply, installation & testing of Microprocessor based three phase relay system for over current, earth fault protection type MICOM/CGI 14N Model for 11 KV breaker, setting range with necessary wiring/fitting including dismantling of old IDMTL/Unserviceable relays.as directed by Engr-in-charge.
S&F Hooter system operating voltage 24V/220V AC/DC for 4 Nos VCB parallel operating system complete with testing including all accessories such as contactor,re-set switch and cut- out complete wiring etc including taking down old U/S, and as directed by Engr-in-charge.
Disconnecting of HT supply from 11 KV VCB of capacity upto 800 Amps for rewiring of VCB control circuit with copper conductor wire size not less than 1.0 Sqmm and after wiring testing complete all as directed by Engr-in-Charge.
M&L in replacement of spring charge motor assembly with Gear Assembly operating voltage 220 V AC/ DC suitable for 11 KV VCB of Areva/CG as existing on site complete with required material and as directed by Engr-in-charge.
Supply & fixing HT Jumper not more than 2 m long in repair /replacement on existing OH circuit/two Pole /four Pole Structure etc including ACSR Conductor (Weasel) using PG clamp/lugs, fastners etc as per site requirment.
S & F epoxy based cast resin CT having ratio 200-150-100//05 for sutiable for 11 KV system size as per site and as directed by Engr-in-Charge.
Supply and Fixing in replacement LED/Neon indicator Lamps with holder size 22.5mm of different colour (24 V/220 V, AC/DC).
M&L for rectification, detection of gas leakage & refilling of the 33 KV, SF6 in compatible to the pressure marked by the OEM complete all as specified and directed.
Supply & Filling of transformer oil in transformer in situ/at site for toping up the level of oil having dielectric strength 60-80 KV during filling after filtration conforming to IS-335.
M&L earthing with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 32 mm x 6 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cove rwith handle complete all as specified & tested complete as per electrical plate No. 3 of MES SSR Part-I. NOTE:- (i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.00 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Quoted shall include the cost of 7.5 metre GI pipe for protection of earth wire/strip. (iii) Quoted shall include cost of 7.5 metre earth lead wire/strip. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sidesNOTE:- (i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.00 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Quoted shall include the cost of 7.5 metre GI pipe for protection of earth wire/strip. (iii) Quoted shall include cost of 7.5 metre earth lead wire/strip. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides
Supply & Fixing Polyfloor insulating rubber mat suitable for 11 KV sub station of size 2mtr x 1mtr x 3mm thick ISI mark, IS 15652 complete and as directed by Engr-in-Charge.
Dehydration /filtration of transformer oil of existing transformers installed at site with portable plant to improve the dielectric strength above 60 KV after filtration including testing of dielectric strength after dehydration at site.
Supply, laying and commissioning XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade IS-7098 marked, suitable for HT 11 KV (E) System laid in trenches/ ducts/ encased in GI pipe/ fixed to poles including jointing & testing complete all as specified and directed of size 95 Sqmm, 3 core cable including taking down/dismantling old item.
-ditto- 185 Sqmm, 3 core cable
M&L for cable end termination, jointing kit, HT 11 KV grade, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade complete all as specified and directed of size 95 Sqmm x 3 core .
Z & -ditto- but 120 to 185 Sqmm x 3 core êM&L for cable straight thr
湩楴杮欠瑩呈ㄠ‱噋朠慲敤敨瑡猠牨湩慫汢ⱥ漠瑵潤牯琠灹潣灭敬整眠瑩潪湩楴杮洠瑡牥慩畳瑩扡敬映牯䠠⁔䱘䕐挠扡敬㌠挠牯ㄱ䬠⁖牧摡潣灭敬整愠汬愠灳捥晩敩湡楤敲瑣摥漠楳敺㤠‵煓浭砠㌠挠牯䴮က娀ఀࠀ♍⁌潦慣汢湥整浲湩瑡潩Ɱ樠楯瑮湩楫ⱴ䠠⁔ㄱ䬠⁖牧摡ⱥ栠慥⁴桳楲歮扡敬湩潤牯琠灹潣灭敬整眠瑩潪湩楴杮洠瑡牥慩畳瑩扡敬映牯䠠⁔䱘䕐挠扡敬㌠挠牯ㄱ䬠⁖牧摡潣灭敬整愠汬愠灳捥晩敩湡楤敲瑣摥漠猠穩㤠‵煓浭砠㌠挠牯MZ % 搭瑩潴戠瑵ㄠ〲琠㠱‵煓浭砠㌠挠牯®䴀䰦映牯†慦汵⁴楦摮湩湩唠䜯挠扡敬甠楳杮映畡瑬氠捯瑡湩慭档湩湯爠煥極敲敭瑮映牯ㄠ‱噋䠠⁔慣汢獥漠湡⁹祴数猯穩潣灭敬整愠汬愠灳捥晩敩湡楤敲瑣摥戠⁹湅牧椭档牡敧牔浩業杮漠牴敥䠠⁔癯牥栠慥楬敮ⱳ䘠畯潰敬猠牴捵畴敲ⱳ睔潰敬猠牴捵畴敲ⱳ牔湡晳牯敭獲愠摮猠楷捴票牡楶楣楮祴漠汥捥牴捩猠灵汰⁹潰敬猯牴敥⁴楬桧⁴潰敬猯汯牡洠摯汵獥☠†敤潰楳楴杮愠⁴汰捡獥渠攠捸㔠洰愠汬愠楤敲瑣摥戠⁹湅楧敮牥椭桃牡敧娠慐湩楴杮漠呈映畯潰敬琯潷瀠汯瑳畲瑣牵獥椠据畬楤杮䜠䑏挠浯汰瑥瑡瘠牡潩獵瀠慬散ⱳ愠灰祬湩睴潣瑡景猠湹桴瑥捩攠慮敭慰湩⁴景愠畬業楮浵挠汯畯祢猠牰祡湩潣灭敬整椠据畬楤杮瀠敲慰慲楴湯漠汯畳晲捡獥敲潭楶杮☠挠敬湡湩景挠牯潲楳湯愠汬愠灳捥晩敩湡楤敲瑣摥戠⁹湅楧敮牥椠桃牡敧汰捡獥†污獡搠物捥整祢䔠杮湩敥湩䌭慨杲†Ĩ倀楡瑮湩景䠠⁔睳瑩档慹摲ㄠ‱噋猠扵猭慴楴湯椠据畬楤杮䜠䑏挠浯汰瑥瑡瘠牡潩獵瀠慬散ⱳ愠灰祬湩睴潣瑡景猠湹桴瑥捩攠慮敭慰湩⁴景愠畬業楮浵挠汯畯祢猠牰祡湩潣灭敬整椠据畬楤杮瀠敲慰慲楴湯漠汯畳晲捡獥敲潭楶杮☠挠敬湡湩景挠牯潲楳湯愠汬愠灳捥晩敩湡楤敲瑣摥戠⁹湅楧敮牥椠桃牡敧㸮慌潢牵漠汮⁹潦映硩湩挠扡敬攠摮琠牥業慮楴湯䠠⁔樠楯瑮湩楫ⱴㄠ‱噋朠慲敤敨瑡猠牨湩慫汢ⱥ椠摮潯漯瑵搠潯祴数†猠穩㤠‵煓浭砠㌠挠牯琠㐲‰煓浭㌠挠牯潣灭敬整眠瑩潪湩楴杮洠瑡牥慩慭楫杮愠汬攠敬瑣楲慣潣湮捥楴湯獡搠物捥整祢䔠杮湩䌭慨杲丠呏⁅ⴺ†呈挠扡敬䨠楯瑮†桳污敢瀠潲楶敤湵敤捓䈧ਧľ䰀扡畯湯祬映牯†楦楸杮†慣汢瑳慲杩瑨琠牨畯桧呈†潪湩楴杮欠瑩ㄠ‱噋朠慲敤敨瑡猠牨湩慫汢ⱥ椠摮潯漯瑵搠潯祴数†楳敺†㔹匠浱⁸″潣敲†潴㈠〴匠浱″潣敲挠浯汰瑥楷桴樠楯瑮湩慭整楲污洠歡湩污汥捥牴捩污挠湯敮瑣潩獮愠楤敲瑣摥戠⁹湅牧椭桃牡敧低䕔㨠䠠⁔慣汢潊湩⁴猠慨汬戠牰癯摩摥甠摮牥匠档✠❂㼠慌潢牵漠汮⁹潦映硩湩挠扡敬猠牴楡桧⁴桴潲杵ⱨ䠠⁔樠楯瑮湩楫ⱴ†㌳䬠⁖牧摡ⱥ栠慥⁴桳楲歮扡敬湩潤牯⼠畯⁴潤牯琠灹猠穩ㄠ㔸匠浱⁸″潣敲†潴㌠〰匠浱″潣敲挠浯汰瑥楷桴樠楯瑮湩慭整楲污洠歡湩污汥捥牴捩污挠湯敮瑣潩獮愠楤敲瑣摥戠⁹湅牧椭桃牡敧低䕔㨠䠠⁔慣汢潊湩⁴猠慨汬戠牰癯摩摥甠摮牥匠档✠❂㼠慌潢牵漠汮⁹潦映硩湩挠扡敬攠摮琠牥業慮楴湯䠠⁔樠楯瑮湩楫ⱴ㌠″噋朠慲敤敨瑡猠牨湩慫汢ⱥ椠摮潯漯瑵搠潯祴数†猠穩ㄠ㔸匠浱⁸″潣敲†潴㌠〰匠浱″潣敲挠浯汰瑥楷桴樠楯瑮湩慭整楲污洠歡湩污汥捥牴捩污挠湯敮瑣潩獮愠楤敲瑣摥戠⁹湅牧椭桃牡敧低䕔㨠䠠⁔慣汢潊湩⁴猠慨汬戠牰癯摩摥甠摮牥匠档✠❂ࠊ慌潢牵漠汮⁹潦氠祡湩湡整瑳湩景䠠⁔䱘䕐挠扡敬ㄱ䬠⁖牧摡ⱥ猠穩㤠‵煓浭砠㌠挠牯琠㐲‰煓浭㌠挠牯潣灭敬整眠瑩潪湩楴杮洠瑡牥慩慭楫杮愠汬攠敬瑣楲慣潣湮捥楴湯獡搠物捥整祢䔠杮湩䌭慨杲ਠ低䕔㨠䠠⁔慣汢ㄱ䬠⁖桳污敢瀠潲楶敤湵敤捓䈧‧á䴀䰦愠摮吠倦映牯琠杩瑨湥湩景樠浵数獲愠摮戠獵慢湡湡牧慥楳杮漠佇⁄瑡映畯⽲睴潰敬猠牴捵畴敲湡楴桧整楮杮漠慣汢瑡䠠⁔湡呌愠⁴潢桴攠摮漠牴湡晳牯敭獲挠浯汰瑥景愠汬愠灳捥晩敩湡楤敲瑣摥戠⁹湅牧椭档牡敧Ʈ匀灵汰⁹…楦楸杮挠慨湩氠湩敦据湩景猠穩⸲‱瑭敨杩瑨愠摮眠物敭桳猠穩〱洰⁸〱洰Ɑ㐠浭搠慩椠据畬楤杮氠湩楷敲ⱳ†祴数漠敭桳愠数瑳湡慤摲猠穩ⱥ爠楡獬瑳慲湩湩潢瑬ⱳ攠捴椠据畬楤杮瀠潲楶楳湯漠楢摮湩楷敲愠摮琠歡湩畯⁴汯敦据湩污獡搠物捥整湡灳捥晩敩†††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††††♍⁌潦楍摬匠整汥眠牯畳档愠湡汧物湯映湥楣杮瀠獯⁴瑳畲獴愠摮映慬⁴物湯映汩敬獴攠捴漠牧摡敆㌭〱〭湩汣摵湩牤汩楬杮栠汯獥異据楨杮灳楬瑴湩湥獤琠敳畣敲挠慨湩氠湩敦据湩牯映硩湩景戠牡敢楷敲琠潰瑳湩汣摵湩污敮散獳牡⁹畣瑴湩Ⱨ眠汥楤杮搠楲汬湩Ⱨ戠汯楴杮漠楲敶楴杮攠捴愠摮椠据畬楤杮戠湡獤猠牴灡猠灵潰瑲映牯挠慨湩氠湩Ⱬ猠整汥猠牣睥愠敲畱物摥ㄬ洰楤卍戠牡愠湩琠敩戠牡⽳潨楲潺瑮污戠牡楦數潴猠捥牵桴敦据湩湯瀠獯獴挠浯汰瑥湡潲汬摥洠汩瑳敥牆浡摥眠牯獡椠慇整景愠杮敬漠瑯敨敳瑣潩楷桴朠獵敳⁴汰瑡獥慲汩ⱳ戠慲散ⱳ攠捴Ⱞ挠浯汰瑥ⱥ搠楲汬摥映牯映硩湩景猠整汥猠敨瑥湩牯漠桴牥挠癯牥湩Ⱨ䐠潯獲攠捴潴戠牰灥牡摥映牯栠湡楧杮漠汳摩湩楷桴☠椠据畬楤杮攠瑩敨潨歯…楨杮獥漠瑳敥慨杮湩潤牯映瑩楴杮攨捸畬楳敶漠瑳敥桳敥楴杮漠瑯敨潣敶楲杮畲湮湩慲汩…畧摩獥 …慨杮湩㭧愠獬慦瑳湥湩…楦楸杮挠浯汰瑥䑇⁅敆㐠〱〭漠敆㌠〱〭椠据畬楤杮琠歡湩潤湷漠摬映湥楣杮愠汬愠灳捥晩敩湡楤敲瑣摥戠⁹湅牧椭桃牡敧♍⁌潦畓晲捡牄獥楳杮 汃慥楮杮漠慶楲畯ㄱ㌯″噋猠扵猭慴楴湯牦敥映潲敶敧慴楴湯漠湡⁹祴数椠据畬楤杮琠楲浭湩景琠敲牢湡档獥畢桳獥牣敥数獲瑥愠獬湯映湥楣杮†潣灭敬整愠汬愠灳捥晩敩…楤敲瑣摥上瑯㩥吠敨映敲畱湥祣漠畳晲捡牤獥楳杮猠慨汬渠瑯戠敬獳琠慨‱潭瑮獨ȸ倀潲楶楤杮愠摮氠祡湩瑡漠敮牡朠潲湵敬敶慦瑣牯⁹慭敤欠牥瑳湯景䴠㈭‵牧摡散敭瑮挠湯牣瑥湩瀠獯瑩潩潴琠敨爠煥極敲楬敮敬敶湡畣癲瑡牵ⱥ樠楯瑮摥眠瑩散敭瑮洠牯慴㨱″ㄨ挠浥湥㩴㌠挠慯獲慳摮Ⱙ椠据畬楤杮洠歡湩潪湩獴眠瑩牯眠瑩潨瑵朠潲癯獥⠠桴捩湫獥景樠楯瑮硥散瑰愠⁴桳牡⁰畣癲桳污潮⁴潴洠牯桴湡㔠洠⥭湩汣摵湩慭楫杮搠慲湩条灯湥湩桷牥癥牥爠煥極敲潣灭敬整潆污瑩浥潎整㨠汁呈攠畱灩敭瑮楬敫吠慲獮潦浲牥嘬䉃ⱳ敒慬獹猠潨汵敢琠獥整祢愠祮䜠癯⁴牯愠瑵潨楲敺条湥祣愠摮琠獥楴杮爠灥牯⁴桳畯摬戠畳浢瑩摥眠瑩楦慮楢汬輮♍⁌潦慣楬牢瑡潩湡敳瑴湩景瀠潲整瑣潩敲慬⁹景愠祮洠歡牯琠灹楦瑴摥漠㌳䬠⁖牢慥敫獲瀠湡汥䤨䵄⁔敲慬ⱹ琠慲獮潦浲牥䈠捵档汯⁺敲慬ⱹ圠䥔呏ⱔ倠噒挠湯牴汯瀠湡汥愠⁴前ⱓ愠摮挠牥慴湩漠桴牥氠捯瑡潩獮†獡瀠牥䤠⁓湡潣敤漠牰捡楴散琠湥畳敲丠⁏剅佒⁒湩汣摵湩敳瑴湩潦慥瑲慦汵ⱴ漠敶畣牲湥⁴楷桴琠楲⁰楴敭搠汥祡椠捡潣摲湡散琠敦摥牥氠慯湡瑯敨慰慲敭整獲漠楳整椠据畬楤杮琠浩牧摡湩景琠敨猠浡楷桴䨠噖䱎猠瑥楴杮琠湥畳敲琠慨⁴慦汵⁴桳污潮⁴牴癡汥琠敮牡獥⁴潳牵散映敥敤㭲椠据畬楤杮洠湩牯爠灥楡獲敲汰捡浥湥⁴景眠物湩瑥…畳浢瑩琠獥⁴散瑲晩捩瑡景愠潢敶爠汥祡琠獥楴杮愠摮挠污扩慲楴湯攠捴挠浯汰瑥污獡猠数楣楦摥愠摮搠物捥整⠊⥡䌠湯牴汯愠摮删汥祡瀠湡汥漠㌳䬠⁖牢慥敫㐰丠獯ਮ戨 ㌳ㄯ‱噋‵噍⁁牴湡晳牯敭敲慬⁹潣瑮潲慰敮〭‴潎ੳ潎整ⴺ吠敨映敲畱捥祮漠整瑳湩湡慣楬牢瑡潩桳污敢搠湯睴捩獡挠慨杮景猠慥潳敢睴敥楷瑮牥琠畳浭牥愠摮瘠捩敶獲ᔊࠄ♍⁌潦慣楬牢瑡潩湡敳瑴湩景瀠潲整瑣潩敲慬獹漠湡⁹慭敫†映瑩整湯ㄠ‱噋嘠䉃搨瑥楡獬朠癩湥戠汥睯 獡瀠牥䤠⁓湡潣敤漠牰捡楴散琠湥畳敲丠⁏剅佒⁒湩汣摵湩敳瑴湩潦慥档映畡瑬漠敶畣牲湥⁴楷桴琠楲⁰楴敭搠汥祡椠捡潣摲湡散琠敦摥牥氠慯湡瑯敨慰慲敭整獲漠楳整椠据畬楤杮朠慲楤杮眠瑩湩潣敭慰敮獬愠⁴前⁓猬湹档潲楮楺杮漠桴慳敭眠瑩前⁓猠瑥楴杮琠湥畳敲琠慨⁴慦汵⁴桳污潮⁴牴癡汥琠敮牡獥⁴潳牵散映敥敤湩汣摵湩業潮敲慰物ⱳ爠灥慬散敭瑮漠楷楲杮攠捴晩爠煥極敲匠牥楶楣杮挠浯汰瑥楷桴搠捥牡潢楮楺杮琠敨挠湯慴瑣†潰湩獴汣慥楮杮眠瑩剃⁃猠汯瑵潩瑥䄠汬椠摮捩瑡湩慬灭漠桴慰敮敲汰捡摥椠敮散獳牡ⱹ戠敲歡牥挠湯牴汯猠楷捴ⱨ搠杩瑩污䄠灭洠瑥牥潖瑬洠瑥牥猠潨汵敢爠灥慬散晩椠慣敳映畯摮搠晥捥楴敶整瑳湩晡整敲慰物挠浯汰瑥污獡搠物捥整祢䔠杮湩敥湩䌭慨杲景愠祮洠歡湡祴数潎整ⴺ匠牥楶楣杮眠汩敢搠湯睴捩瑡琠敨搠牵瑡潩睴捩湩搠牵瑡潩景挠湯慴瑣愠摮琠楨眠汩敢挠湯楳敤敲獡漠敮樠扯污獡搠物捥整祢䔠杮湩敥椠䌠慨杲⠊⥡传瑵朠楯杮⼠䤠据浯湩ㄱ䬠ⵖㄠ′潎ੳᐊఄ刀♍⁌潦慣楬牢瑡潩湡整瑳湩景瀠潲整瑣潩敲慬⁹景愠祮洠歡牯琠灹楦瑴摥漠㌳䬠⁖″慗⁹䵒⁕†獡瀠牥䤠⁓湡潣敤漠牰捡楴散琠湥畳敲丠⁏剅佒⁒湩汣摵湩敳瑴湩潦慥档映畡瑬漠敶畣牲湥⁴楷桴琠楲⁰楴敭搠汥祡椠捡潣摲湡散琠敦摥牥氠慯湡瑯敨慰慲敭整獲漠楳整椠据畬楤杮朠慲楤杮眠瑩湩潣敭慰敮獬愠⁴前⹓匠牥楶楣杮挠浯汰瑥楷桴搠捥牡潢楮楺杮琠敨挠湯慴瑣†潰湩獴汣慥楮杮眠瑩剃⁃猠汯瑵潩瑥䄠汬椠摮捩瑡湩慬灭漠桴慰敮敲汰捡摥椠敮散獳牡ⱹ戠敲歡牥挠湯牴汯猠楷捴ⱨ搠杩瑩污䄠灭洠瑥牥潖瑬洠瑥牥猠潨汵敢
Z & -ditto- but 120 to 185 Sqmm x 3 core êM&L for cable straight thr
replaced if in case found defective, testing after repair complete all as directed by Engineer-in-Charge of any make and type. Note:- Servicing will be done twice at the duration twice in duration of contact and this will be considered as one job NOTE FOR ITEM NO. 32 to 35(i) The calibration and setting must be completed with in 3 weeks from the date of commencement placed to avoid major break down. (ii) The calibration and setting shall be carried out by only qualified and experienced engineer. (iii) The relay setting shall be carried out once in three month as per load and site conditions to avoid any fault travel to next adjacent source breaker and shall be monitored regularly. (iv) For payment purpose the payment for calibration of relay once in 06 months and setting of relay twice in 06 months is considered as one job. The cost of monitoring is also included in the item rate. (v) Calibration Certificate by authorised person should be submitted after calibraction/setting the VCBs. The record of calibration/setting of relays shall be submitted by the Contractor.ÉSupply and laying stone aggregate of size 40-80 mm upto height of 30 cm after the height of sand cushioning (river sand) which will be laid upto height of 15 cm before laying stone aggregate in sub-stations/electric yards including levelling. complete all as specified and directed Note:- It should be ensured that before laying stone aggregate and sand the grass or unwanted bushes shall be treated chemically to remove the unwanted vegetation and surface of the switchyard/installation should be made totally free from the existing unused aggregates without destroying the cable, earthpit etc at the installation including waterproof tarpaulin, all area covered by waterproof tarpaulin before laying of sand.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
RETENDER82534.pdf
Tender Documents • 0.70 MB
BOQ_846131.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .