Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹25.4 L+₹36,019 (1.44%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹26.4 L+₹1.4 L (5.79%)Rejected-Finance 140 DEORISINGHPURA RANIPUR JHANSI JHANSI UTTAR PRADESH 284205 UDYAM UP 39 0007853 | JHANSI | UTTAR PRADESH | 284205 | L3 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
7 Mar 2023, 6:00 pmClosed
Lt Col Priyesh Srivastava
GE (AF) SURATGARH
SHIFTING AND INSTALLATION OF GROUND RUN BLAST DEFLECTOR WITH PICKETING HOOKS AT 23 SQN WITH MISCELLANEOUS BUILDING RELATED WORKS AND DRILLING AND LAYING OF OFC CABLES FROM PAR 8044 HUT TO GCA DISPLAY AT AF STN SURATGARH
2023_MES_573977_2
8023/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹48,000
Yes
22 Mar 2023
14 Feb 2023
9 Mar 2023
14 Feb 2023
7 Mar 2023
21 Feb 2023
Amount
(SHIFTING AND INSTALLATION OF GROUND RUN BLAST DEFLECTOR WITH PICKETING HOOKS AT 23 SQN WITH MISCELLANEOUS BUILDING RELATED WORKS AND DRILLING AND LAYING OF OFC CABLES FROM PAR 8044 HUT TO GCA DISPLAY AT AF STN SURATGARH)
Demolition of cement concrete (PQC) (Rigid/Flexible Pavement) by PQC cutting machine or mechanical equipment (JCB Breaker) of any depth exc 15cm thickness Below of Existing ground Level including removing of PQC materials etc to out side of MOD land complete all as specified and directed by Engr-in-charge.
M & L for providiing Reinforced Cement Concrete M-30 grade, Design Mix, as in columns, pillars, piers, posts & struts complete all as specified and as directed.
Use and waste of Form work to sides of concrete in foundations, footing base, base of columns, side and soffits of roof beam and similar work complete all as specified and as directed.
S&F TMT bars 10mm dia and over , cut to length, bent to shape requred, including cranking bending and binding with mild steel (annealed) wire not less than 0.90mm dia complete all as specified and as directed.
Dismantling mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge
M&L for Rolled Mild Steel Plates (plain or Chequered) channels, square cut or notched, forming holes, with riveted, bolted or welded attachment confirming to Fe 410 - W complete all as specified and as directed.
M & L for Rolled Mild Steel Plates (plain or Chequered) channels, square cut or notched, forming holes, with riveted, bolted or welded attachment confirming to Fe 410 - W (fixing only except Material) complete all as specified and as directed.
S&F mild steel for framed structure like trusses, purlins, crane gantries,post rails and fastenings and heavy bracket framming (Beam,Tee, Angle, Channels, flat sections) including distance pieces, cleats etc conforming to Fe410-W (Gde-E-250) quality-A complete all as specified and as directed.
M & L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors complete all as specified and as directed.
M&L for Machine pressed precast concrete interlocking paver block ISI Marked any shape and size confirming to IS 15658-2021 of 60mm thickness, M-35 Grade with grey cement and no pigment complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block ISI Marked any shape and size confirming to IS 15658-2021 of 80mm thickness, M-40 Grade with grey cement and no pigment complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation Complete all as specified and directed.
Providing 400 micron polythene film as per IS-2508 laid over sand layer including all necessary cutting, overlaps not less than 300mm and wastage complete all as specified and as directed by Engr-in-charge. Note:- Sand layer measured and paid separately.
M&L for pavement quality cement concrete work in pavement of flexural strength 45kg/Sqm using minimum 400kg of cement/cum as per design mix including mixing of non circular polyester fibre @ 1 kg/Cum all as per design mix laid and finished by using fixed form work of steel along with Concrete roller screed paver machine including electric vibrator of approved size shall be used with prior approval of GE complete all as specified and directed by Engr-in-charge. Note:- (1) supply of polyester non-circular fibre as secondary reinforced shall be measured and paid separately
Supply only non circular polyster fiber as secondary reinforcement with circumcircle diameter 30-35 micron design for melting point 240-260 degree celcius and having of 1.34 to 1.4 recron (recron 3s from reliance) @ 1 kg/Cum of concrete complete all as specified and directed.
Material and Labour for repairing to concrete slab surface (depressed portion/cracked portion) by cutting damaged/spilled portion and concrete pavement by mechanical equipment into rectangular crossed section, removing useless and worthless all loose and foreign materials etc to a distance exceeding 500m but not exceeding 1000 meter cleaning the surface thoroughly with brushes and finally with compressed air, including filling and levelling the surface, priming the patches with special primer recommended by manufacturer and filling with modified ready mix ELASTOMERIC concrete not exceeding 50mm depth, including form work where required all as per manufacture's instructions complete all as specified and directed. MAKE: Dr Fixit / Bostik / Chokesy Chemical / STP LTD (Product Name "Flex O Patch") or equivalent. Note : Complete quantity of material required shall be supplied in advance within 15 days of commencement of work.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish of the premises complete all as specified and as directed.
M&L Glazed coloured ceramic tiles in vertical surface 300mm x 450 mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing over 10 mm thick back coat in CM 1:4 complete all as specified and as directed.
M & L for white ceramic non-skid tiles area of tiles exceeding 0.11 sqm but not exceeding 0.18 sqm and 7-8 mm thick laid in floors, set and jointed in neat cement slurry laid over 15 mm thick screed bed in cement mortar 1:6 to match the shade complete all as specified and as directed.
M & L for Vitrified Ceramic tiles Light shade 10mm thick( square/rectangular) Polished area of each tile not exceeding 0.36sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles laid over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
M&L Dholpur stone 20 mm to 25 mm thick polished stone mixed with pigment to match the shade of the slab including rubbing and polishingof any description or thickness laid over 20 mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including demolition of stone slab and tiles of any description or thickness complete all as specified and as directed.
M&L granite tile 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white/coloured cement with admixture of pigment to match the shade of granite store including cutting and polishing etc complete all as specified and as directed.
All as per item No 23 above over 10mm thick back coat in CM 1:4 on dado/skirting.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in platforms/stair case/ Countertop including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rounding off/curving the edges of granite stone & polishing laid over 20 mm thick screed bed in CM 1:6 complete all as specified & directed.
Complete treating the old surface of granite and kota stone with grinding rubbing and beeswax polishing complete all as specified and directed.
Taking down chowkats with shutter (without taking off shutter from the frame) exc 1.5 Sqm but not 4 Sqm each
Taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 Sqm each
Taking down shutters of any description but exc 1 sqm and not exc 2 sqm each and refixing in same opening complete all as specified and directed.
Taking down chowkats or frames exc 1.5sqm but n exc 4 sqm each complete all as specified.
S & F Framed work of rolled mild steel conforming to Fe-290 (GdeE165) as in doors or gates of angle or other section with gusset plates, rails, braces, etc, drilled for fixing of steel sheeting or other covering; doors etc to be prepared for hanging or sliding with and including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting, running rails & guides) and hanging, fastening & fixing complete all as specified and directed.
S&F 35mm thick 2nd class HW Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F 35mm thick Flush door shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed by Engr-in-Charge
S&F floor door stopper 150mm overall length of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed by Engr-in-Charge
Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like including all necessary labours, articles n exc 200 Cu.cm each in 2nd class Hard Wood complete all as specified and directed.
S&F mild steel butt hinges of size 100mm, medium weight, cold rolled complete all as specified and directed.
S&F 300mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S&F mild steel barrel tower bolt 200mm, stove enamelled black with bright bolts complete all as specified and directed.
S&F mild steel pressed handles 150mm, oval type, stove enamelled black complete all as specified and directed.
M&L for 2 coats of synthetic enamel painting to wood and wood based surfaces of any description, not otherwise described over 10cm width or girth over one coat of pink primer including preparation of new surfaces complete all as specified and directed..
S&F steel window with side hung shutter including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges with steel peg stay, complete without glazing bars,complete all as specified and directed.
M&L for 2 coats of synthetic enemel painting to iron and steel surfaces of any description over a coat of red oxide primer not otherwise described over 10cm width or girth including preparation of new steel surfaces complete all as specified and directed.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, Windows ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and complete all as specified and directed.
Providing and fixing Anodised aluminium (minimum thickness of powder coating 50 micron) work for doors, Windows ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and complete all as specified and directed.
M & L 12 mm thick both sides prelaminated Particle board, medium density, fixed with screws to frame work in cup board shutters, partitions, shelves complete all as specified and directed.
S & F 4.8mm thick sheet glass, ordinary quality and in square exc 0.5 sq.m in each pane in any position complete all as specified and directed.
S & F in repair door closer hydraulically regulated, design No 3 universal type suitable for door shutter 851 mm to 1000 mm in width and of weight 61 to 80 Kg each cast iron body complete all as specified and directed.
S & F solid PVC door frame of size 50 mm x 47 mm made out of 5mm thick PVC sheet reinforced with mild steel square tube complete all as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing complete all as per specification and directed.
S&F aluminum anodized ‘D’ type handles 125 mm complete all as specified and directed .
S&F 150 mm aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
S & F 100 mm Aluminium polished butt hinges type B12 complete all as specified and as directed.
S&F in repair waste coupling of PTMT (half or full threaded). (Minimum weight 32mm-45 gms)complete all as specified and directed.
Supply only flush pipe of polyethylene flexible of low or high density or PVC, 32mm dia, for wash hand basin, Urinal complete all as specified and directed.
S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F 15mm bore Pillar taps cast copper alloy, with capstan head, fancy type, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and flynuts, screwed for iron pipe complete all as specified and directed.
S&F 15mm Stop valve, fancy type, chromium plated with long shank and cup (concealed type) high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F Grating doom 125mm dia with \waste hole of PTMT (minimum weight 40 gms)
S & F in repair Vitreous China Ware Wash hand basin white, flat back, size 630 x 450 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand complete all as specified and directed..
S & F in repairs counter wash hand basin vitreous china white oval shape size 440X525X195mm including waste coupling of 32mm complete making good the surface / joints with white cement complete all as specified and as directed.
S & F in repairs 15 mm bore chromium plated fancy type brass angle valve with wall flange screwed down high pressure screwed both ends for Iron pipe or for union complete including CP cap complete all as specified and directed.
S & F in repairs 600mm long PVC connection with CP brass nuts & PVC /rubber washer suitable for 15mm dia tap / pipes complete all as specified and directed.
S & F in repairs 32 mm bore waste pipe for WHB, Sink, Urinals etc complete all as specified and as directed.
S & F in repair vitreous china urinals half stall type white including connection to inlet and out going pipe (waste coupling) complete fixed to walls with steel screws and PVC rawl plug, waste coupling and and making good the surface by white cement to match the wall shade complete all as specified and as directed.
S&F in repair Vitreous china urinal partition white of size 310x700mm complete all as specified and as directed by Engr-in-Charge
M & L for Vitreous China wash down water closet pan (pedestal pattern), white including fixing bolts, with inlet, ball valve, float and handle including brackets and Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern ® including Plastic water closet seat, black, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
Dismantling of CI pipes jointed CM & taking out of branches if required complete all as specified and directed.
S&F cast iron spun soil waste and vent pipes in any length with or without ears, jointed with lead joints, fixed to wall or laid in trenches / in floors (bore of pipe 100 mm) complete all as specified and directed.
S&F cast iron spun soil waste and vent pipes in any length with or without ears, jointed with lead joints, fixed to wall or laid in trenches / in floors (bore of pipe 75 mm) complete all as specified and directed..
S&F 75 mm CI bends any radius, diminishing pieces or tapers of any description complete all as directed by Engr-in-Charge.
S&F 100 mm CI bends any radius, diminishing pieces or tapers of any description complete all as directed by Engr-in-Charge.
S&F in repairs 100 mm bore Tee/branch piece single (Equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F in repairs 75 mm bore Tee/branch piece single (Equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F 75mm cast iron floor trap, with gratting including jointing to waste pipe fixed in cement concretetype B1(1:2:4), fixed in repair complete all as specified and directed.
S&F 75mm cast iron Nahani trap, with gratting including jointing to waste pipe fixed in cement concrete type B1(1:2:4), fixed in repair complete all as specified and directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) Gully trap 125/110mm, setting and jointing with solvent cement, fixed in repair complete all as specified and directed.
Hacking out old broken glass (any thickness , size , quality or description) from metal frame including punching or drilling out old glazing pins /spring clips and provding and fixing new ones complete all as specified and directed.
S&F 3 mm thick plain sheet glass ordinary quality & glazing with oil putty in square n exc 0.50sqm in each pane complete all as specified and directed.
S&F, Frosted sheet glass 3 mm thick, ordinary quality and glazing with oil putty (in metal frames etc) in squares not exceeding 0.5 Sq. m in each pane, complete all as specified and directed.
S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
Demolition of Brickwork or stone/boulders masonry built in cement mortar complete all as specified and as directed by Engr-in-charge
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cm 1 : 6 complete all as specified and as directed by Engr-in-Charge.
All as per item NO 86 here-in-before but except brick complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed.
Applying two coats of exterior acrylic emulsion (weather proof treatment), in camouflaging patterns , including preparation over new plastered surfaces complete all as specified and directed.
M&L for 1-1.5 mm thick birla/JK wall care putty to receive smooth finishes complete all as specified and directed.
M&L for painting of treated surfaces to receive two coat of distemper oil emulsion on surfaces of walls and ceiling complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections,including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20mm dia steel tubing and connections,including cleaning for refixing or removal to store complete all as specified and as directed.
S&F 15 mm GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floor complete all as specified and directed.
S&F 20mm GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floor complete all as specified and directed.
Re-fixing steel water tubing of 15 mm bore, with all fittings at new or old position, laid in floor along wall or at ceiling, complete all as specified and directed.
Re-fixing steel water tubing of 20 mm bore, with all fittings at new or old position, laid in floor along wall or at ceiling, complete all as specified and directed.
M&L for cutting chases for concealed water tubing or pinning end etc and making good the facing /cutting in cm 1 : 3 width exc 10 cm but not exc 20 cm girth in brick walls etc complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L PCC type B1 1:2:4 (using 20mm graded aggregate) 25 mm thick as in floor finished surfaces fair and even to receive tile complete all as specified and as directed by Engr-in-Charge
M&L for PCC 1:3:6 type C2 (using 40 mm grade aggregate) 75 mm thick as in plinth protection / paving finished fair and even without using extra cement complete all as specified and directed.
Demolition of RCC of any description in any position not otherwise specially provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L for providing reinforcement cement concrete 1:2:4 type B1(using 20mm graded stone agg) as in slabs/ beams/column in floors balconies,canopies, desc slabs and the shelves and the like complete all as specified and directed.
M&L for RCC chajjas 1:2:4 type B0 (using 12.5mm graded aggregate) as in approved design all as directed by Engr-in-Charge
Use and waste of Formwork to soffits of suspended slab such as roof slab, floor slab, landing and similar work n.exc 200mm thick (Horizontal or sloping) flat in fair finished surfaces of concrete complete all as specified and directed.
Use and waste of Formwork to cornices and mouldings of any shape in cross section and any girth in fair finished surfaces of concrete complete all as specified and as directed by Engr-in-Charge
Use and waste of Formwork to edges of concrete flats, treads breaks in floor, window cills, concrete railing, openings in concrete walls, floor and roofs and similar works exc 5cm but n.exc 10cm wide rough finish surface of concrete complete all as specified and directed.
Use and waste of Form work to edge of concrete flats, breaks in floors, opening in concrete walls,floors and roofs and side of RCC/PCC bands in walls ad similar works n exc 20cm thick,complete all as specified and directed.
S&F TMT bars 6 to 8mm dia , cut to length, bent to shape requred, including cranking bending and binding with mild steel (annealed) wire not less than 0.90mm dia complete all as specified and directed..
Dismantling existing water tank of capacity 500ltr capacity and removing to store yard complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of capacity 500 ltrs complete all as specified and directed.
S&F in repairs 20mm bore dia nipple suitable for HDPE water tank. (minimum weight 20mm-45gms)
S&F 20mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in repair complete all as specified and directed.
S&F, Ball valve of 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) & fixed in repairs , complete all as specified and directed by Engineer-in-Charge.
Dismantling Structural steel work including doors, gates and plate but excluding framed truss etc complete all as specified and directed by Engr-in-Charge.
Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings complete all as specified and directed by Engr-in-Charge.
S & F MS steel work in tubular trusses including special shaped washers etc., complete using but ERW or induction butt welded tubes confirming to IS 1161- 1979 graded St 240 with one shop coat of zinc chromate primer paint complete all as specified and directed.
M & L 6 mm thick Asbestos Cement sheet, corrugated, or semi corrugated sheets in roofs, walls etc. and fixed with L hook or Cranked bolts complete all as specified and directed.
M&L for pre painted galvanlume aluminium zinc coating having GI based corrugated steel sheets 0.50mm thick of any colour as in tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screw complete all as specified and directed by Engr-in-charge.
S&F mild steel screws bolt (Machine made) with hexagonal or square heads one end screwed , each screwed end have one washer and one nut, dia of shunk 11-15mm and length of bolt exec 5 cm and n exc 10cm complete all as specified and directed.
S&F mild steel flat iron as wind tie for roof including necessary drilling for securing bolts etc complete all as specified and directed.
S&F, Bib tap standard of PTMT ,15mm bore dia of any colour high pressure screwed for iron pipe and fixed as in repair (minimum weight 90gms) ,complete all as specified and directed by Engineer-in-Charge.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid dry or laid dry and pointed complete all as specified and directed.
M&L for coloured designer Chequered cement concrete tiles 300X300X25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments complete all as specified and as directed by Engr-in-Charge.
Dismantling of wall and ceiling or insulation boards/ slabs / PVC panelling any thickness and in any position incl frame grid and cover fillets and framework etc complete all as specified and directed.
M&L for Designer type gypsum ceiling board / mineral fibre board of size 595 mm x 595 mm x 7-8 mm thick as in ceiling, fixed with screws on GI grid frame work of size 600mm x 600 mm, GI T-section of size 25mm x 25 mm x 1.25mm, GI L-section 25 mm x 25 mm x 1.25 mm, hanging arrangements with roof with GI wire not less than 4.00 mm dia, including applying two coats of distemper oil emulsion (of approve shade) after preparation of surface, including taking down existing ceiling board of any description complete as per manufactures instructions , complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on Brick or concrete surfaces incl racking out joints hacking for key scrubbing down with water etc complete
M&L for rendering 5 mm thick in CM 1:3 on concrete surfaces on ceiling / facia /RCC Chhaja etc & finished even & smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
Applying two coats of exterior acrylic emulsion (weather proof treatment), in camouflaging patterns , including preparation of old surfaces like brooming down or steel wire brushing scraping down smoke soot, moulds mass and efflorescent salt and trading oil and greasy spots complete all as specified and directed.
M&L for 3 coat of white washing on newely plastered ceiling surfaces including preparation of surfaces complete all as specified and directed.
M&L for complete removal of existing treament through mechanical scraper machine for any type of existing surface of walls/ceiling complete all as specified and directed by Engr-in-Charge.
M&L for painting of treated surfaces to recive two coats of dry distemper on surfaces of walls and ceiling complete all as specified and directed.
M&L for painting with one coat of synthetic enamel paint on plastered surfaces including preparation of old decorated surfaces of walls/kerb stone etc complete all as specified and directed by Engineer in Charge.
M&L for painting steel surfaces exc 10cm width or girth with one coat of synthetic enamel paint of approved tint including preparation of surfaces complete all as specified and directed.
All as per item No 135 above but on wooden surfaces.
Dismantling Bricks (laid flat or on edge) or brick tiles laid, bedded and pointed in any mortar in floors, channels, kerbs, aprons, etc complete all as specified and directed.
Removing mortar from and cleaning bricks, stacking for measurement including all extra handling and removal and disposing off rubbish complete all as specified and directed..
Demolition Mud in roofs, any thicknes, including plastering and leeping (whether full thickness removed or only or part thereof) including roughing of surface after demolition and Removing the material exc. 1.50 km but n exc.5km and depositing where directed all as specified and directed.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate in roof as levelling course, kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
M&L for 10mm thick cement plaster in CM 1:3 on fair faces of brick work or concrete surfaces and finished even and smooth with out using extra cement but using water proofing compound @ 3% of cement weight complete all as specified and directed.
Supply only Integral waterproofing compound.
M&L for APP based polymeric membrane minimum weighing 3.5 Kg/Sqm and minimum 3mm thick reinfored with polyster non wooven fabric( wt not less than 160gm/sqm ) laid over primed surfaces including bituminous primer conforming to IS-3384applied @ 0.3 Ltr/Sqm by forced application all as specified and directed.
M&L for Applying one coat bitumen grade 85/25 @ 1.2kg / sqm complete all as specified and directed.
M&L for 40mm thick brick tiles are bedded in 15mm thick cement mortar (1:6) and joints grouted flush in cement mortar (1:3) mixed with liquid WPC in lit on APP membrane bedded in cement mortar (1:6) all as specifed and directed by Engr-in-charge.
M&L for reusing the old serviceable 40mm thick tiles bedded in 15mm thick cement mortar (1:6) and joints grouted flush in cement mortar (1:3) mixed with liquid WPC in lit on APP membrane bedded in cement mortar (1:6) all as specifed and directed by Engr-in-charge.
M&L for boring of holes under road/pavement/hard standing by trenchless technology using ultra sound technique and necessary machine including material and labour for insertion of HDPE pipe of 40mm dia suitable for 6kgF/Sq CM working pressure into drilled hole all as directed by Engineer In Charge.
M&L for construction of new valve chamber round shape of size 2M depth and 1M diameter with brick work comprising the following items all as specified and directed:- (a) Brick construction with(1:6) cement mortar rendering 15mm thick plaster externally complete for face of brick work surface. (b) MS Cover of thickness 4mm double door type welded to angle iron frame of size 40X40X6 mm embedded in PCC coping with anchor fasteners including locking arrangement complete with two coats of highly corrosive resistant epoxy paint over one coat of red oxide primer all as specified and directed. (c) 150mm thick PCC foundation(1:2:4) type B2 40mm grade aggregate.
Laying only OFC/AFLS multi core cable mannually/ Mechanically through HDPE pipe already laid in hole/ trench or fixed on wall/ pole and testing including transporting the cable from AF store to site of work complete all as specified and directed. Note : New cable shall be issued by IAF free for laying.
Supply and fix cable route marker made of good quality stone 250mm X 150mm size, 900mm long with top of oval shaped, two sides engraved with letters ' OFC Cable', letter painted with approved paint, embedded in ground including necessary excavation and earthwork complete all as specified and directed.
Preparing the ends of OFC and material & labour for splicing the OFC using OTDR machine as directed by Engineer in Charge.
M&L for Cutting holes not exceeding 150 Sq CM for passing cable, pipe etc into or through brick walls built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete complete all as specified and directed.
Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket or power)complete including fixture and fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings, wooden terminal boxes, plastic laminated sheet cover, including taking down of DB’s, meter board any type all as specified and as directed.
Dismantling and taking down fluorescent tube light single/double of any wattage or size fitting for repair or replacement of burnt/worn out accessories or carrying to MES store(Accessories or components to be provided free for replacment by department), complete all as specified and as directed.
Taking down unserviceable sub main wiring of any type/size including wires, conduits/batten etc, complete all as specified and as directed.
Taking down unserviceable DB's box including MCB's of any size/rating, complete all as specified and as directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volts grade FRLS cable of copper conductor multi stranded of size 1.5 sqmm (Nominal size) drawn through and including non metallic rigid PVC conduit medium grade, ISI marked not less then 20 mm dia with all accessories like tee, straight joint, L bend etc concealed in wall , ceiling , floor etc, pressed GI modular boxes in wall of required size and colour for modular switches and sockets, 1.5 sqmm (Nominal size) PVC insulated (green insulation) copper conductor FRLS earth continuity cable drawn with wiring and connected to common earth dolly all as specified for one light point controlled by one SP switch including making good distrubed surface, complete all as specified and directed. Note :- GI modular boxes shall be measured and paid under respective item & Cost for cutting, chasing and making good to existing surfaces shall deemed to be included in the quoted rate.
All as per Srl item No. 157 here-in-before but for one ceiling fan/exhaust fan and wall mounted fan point controlled by one SP switch, complete all as specified and directed.
All as per Srl item No 157 here-in-before but for one 5 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size, complete all as specified and directed.
All as per Srl item No 157 here-in-before but for one 5 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size, complete all as specified and directed.
All as per Srl item No 157 here-in-before but for one power point 6 pin 15 Amps socket out let with 2.5 Sq mm stranded copper conductor FRLS cable PVC insulated including earth wire 2.5 Sq mm copper conductor FRLS cable connected to earth dolly complete, all as specified and directed.
All as per Srl item No 157 here-in-before but for AC/Geyser with 4 Sq mm stranded copper conductor FRLS cable PVC insulated including earth wire 4.0 Sq mm copper conductor FRLS cable connected to earth dolly complete, all as specified and directed.
S & F Socket outlet, flush type 2 in 1, 3 pin, 5 amps, 240 volts all as specified and as directed by EIC.
S & F switch piano flush button single pole one way 5 amp 240 volts, all as specified and as directed.
S & F Socket outlet 2 in 1, 3 pin, 5 and 15 amps, flush type, 240 volts all as specified and as directed.
S & F switch piano flush button single pole one way 15 amp 240 volts, all as specified and as directed.
S&F of lamp holder, PVC/polycarbonate type, insulated body with back plate of batten fitting complete all as specified and as directed by Engr-in-Charge.
S&F of LED bulb 09 watt, complete all as specified and directed. Make - Crompton cat part No LED 9W - B22/E27 - CDL / WW or equivalent to Polycab/Havells.
M & L for ceiling rose, surface bakelite, 65 x 50 mm, three terminals all as specified and as directed.
S&F energy saving slim design light fitting 230 Volts surface mounted complete with high efficiency PMMA diffuser soft glare free light LED tube light 20 watt, with all accessories, pre-wired, etc including providing flexible copper wire, three core cable PVC insulated sheathed, complete all as specified and directed by Engr-in-Charge. Make- Crompton cat part No for fitting LDSLRP-20-CDL or equivalent in Havells/Bajaj/Polycab/C&S.
S&F LED bulkhead luminaire 10 watt, wall/surface mounted complete with LED lamp 10 watt, all accessories, pre-wired including providing flexible copper wire, twin core cable PVC insulated sheathed, complete all as specified and directed by Engr- in-Charge.
Taking down ceiling fans of any sweep and any size including cable connections and disconnecting of fan blades and removing the fan with blades deposit to store yard as it is in working condition for further hanging in its original position or any other position including as per direction of Engineer-in-Charge including it's fitting and fixtures after carrying out service includes cleaning, greasing and oiling, painting of fan with one coat of synthetic enamel spraying painting including marking of MES number with black paint after preparation of surface reassembling the fan etc including testing complete all as specified and as directed by Engr- in-charge. Note :- Any damage has to be made good by the contractor to make the item functional after testing.
S&F exhaust fan with louvers metallic body, complete 450mm sweep 230 volts, single phase , AC supply complete with nuts, bolts and washers size of the bolts 06 inch long 6mm dia embedded in the wall including provisioning of flexible cord copper of size 1.5 sqmm three core from ceiling rose to exhaust fan for giving connection and providing continous earthing connection complete all as specified and direted by Engr-in-Charge.
S&F Fan step regulator, 120W 230 volts, 50 HZ, AC. Supply complete all as specified and as directed by Engr-in-Charge.
M&L for submain wiring with two single core 6.0 sq mm PVC insulated FRLS multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit of size not less than 25mm dia, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 6.0 Sqmm multistranded copper conductor cable as continuous earth wire complete all as sepcified and as directed. Note- (a) The two runs of single core cable and specified earth continuity conductor and PVC conduit with fitting acessories will be measured as one run. (b) Cost of cutting, chasing and make good to existing surfaces are deemed to be including in the quoted rate by the contractor.
S&F in replacement sheet metal enclosures single pole and neutral earth enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps, 240 volts, complete all as specified and directed.
S&F sheet metal enclosure for distribution board SPN (when MCBs to be used) 8 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed by Engr-in-Charge.
S&F of MCB SP, 6-32A,10KA complete all as specified and as directed by Engr-in-Charge.
S&F of MCB SPN, 32A ,10KA complete all as specified and as directed by Engr-in-Charge.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge, 8 mesh per liner inch, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with XPM JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed.
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.
SRI SAI CONSTRUCTION COMPANY
M/s Tiwari & Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .