Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹37.4 L+₹2.5 L (7.15%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹41.3 L+₹6.4 L (18.2%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹41.6 L+₹6.7 L (19.2%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹43.2 L+₹8.3 L (23.8%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/S PRAJAPATI ENGINEERS L3 | AGGARWAL ASSOCIATES L7 | JAI DURGA CONSTRUCTION CO L6 | R.K. Works L2 | Standard engineers L5 | M/S Shankardass Devidass L1 | M/S Chib Engineers L8 | M/S J S ENGINEERS L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | SCHEDULE 'A' PART -I Taking down carefully unserviceable aluminium point wiring (light, fan, socket bell or power) complete, (fittings such as switches, ceiling rose lamp holder, regulators, sockets, pendants) stacking at site and keeping in safe custody for taking credit complete all as specified & directed | 2,345 | Point | 10 ₹23,450 | 30 ₹70,350 | 10 ₹23,450 | 10 ₹23,450 | 10 ₹23,450 | 5 ₹11,725 Lowest | 12 ₹28,140 | 5 ₹11,725 Lowest |
| 2.00 | Taking down ceiling fan any sweep, removing blades ,cleaning the fan completely for dust and dirt and hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook, rubber pad, nut bolts and washers etc, complete all as specified and directed | 220 | Each Job | 50 ₹11,000 | 100 ₹22,000 | 60 ₹13,200 | 50 ₹11,000 | 55 ₹12,100 | 10 ₹2,200 Lowest | 60 ₹13,200 | 25 ₹5,500 |
| 3.00 | Taking down existing energy meters, keeping aside safely & refixing the same in its original position after making functional & after completion of point wiring/sub main wiring, complete all as specified & directed
Note:- Small items required for fixing the electric energy meter at site shall be provided by the contractor and cost for the same shall be deemed to be included in the quoted rates. | 100 | Each Job | 50 ₹5,000 | 100 ₹10,000 | 60 ₹6,000 | 50 ₹5,000 | 55 ₹5,500 | 20 ₹2,000 Lowest | 60 ₹6,000 | 30 ₹3,000 |
| 4.00 | Taking down existing electric water heater, keeping aside safely & refixing the same to its original position after servicing of the whole geyser/making functional and after completion of wiring work, complete all as specified & directed.
Note: If any part found unserviceable during the refixing of water heater at site shall be provided by the contractor and cost for the same shall be deemed to be included in the quoted rates. | 60 | Each Job | 50 ₹3,000 | 100 ₹6,000 | 60 ₹3,600 | 100 ₹6,000 | 55 ₹3,300 | 50 ₹3,000 | 60 ₹3,600 | 49 ₹2,940 Lowest |
| 5.00 | M&L for point wiring with PVC insulated sheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and in existing PVC conduit of any size , fixing acessories inculding sunken anodised pressed terminal box not less than 1.2 mm thick covered with 3 mm thick bakelite laminated sheet cover of suitable size with suitable size screws for mounting switches, sockets, regulators with and including 1.5 sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly for One light/fan point /bell point controlled by one switch switches/sockets/regulators complete all as specified & directed. | 225 | Point | 300 ₹67,500 Lowest | 350 ₹78,750 | 325 ₹73,125 | 350 ₹78,750 | 310 ₹69,750 | 400 ₹90,000 | 340 ₹76,500 | 390 ₹87,750 |
| 6.00 | All as per Srl item N0 05 above but for one socket out let 5 Amp controlled by one switch on same board with other switch complete all as spd & directed | 40 | Point | 300 ₹12,000 | 350 ₹14,000 | 325 ₹13,000 | 150 ₹6,000 Lowest | 290 ₹11,600 | 430 ₹17,200 | 340 ₹13,600 | 180 ₹7,200 |
| 7.00 | All as per Srl item N0 05 above for one socket out let 5 Amp controlled by one switch on independent board with other switch complete all as specified and directed | 60 | Point | 300 ₹18,000 | 350 ₹21,000 | 325 ₹19,500 | 350 ₹21,000 | 290 ₹17,400 | 400 ₹24,000 | 340 ₹20,400 | 280 ₹16,800 Lowest |
| 8.00 | M&L for point wiring with PVC insulated sheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20 mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed terminal box not less than 1.2 mm thick covered with 3 mm thick bakelite laminated sheet cover of suitable size with suitable size screws for mounting switches, sockets, regulators with and including 1.5 sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly for One light/fan point /bell point controlled by one switch switches/sockets/regulators complete all as specified & directed. | 170 | Point | 300 ₹51,000 | 350 ₹59,500 | 325 ₹55,250 | 350 ₹59,500 | 290 ₹49,300 Lowest | 430 ₹73,100 | 340 ₹57,800 | 390 ₹66,300 |
| 9.00 | All as per Srl item N0 08 above but for one socket out let 5 Amp controlled by one switch on same board with other switch complete all as spd & directed | 30 | Point | 300 ₹9,000 | 350 ₹10,500 | 325 ₹9,750 | 200 ₹6,000 | 310 ₹9,300 | 450 ₹13,500 | 340 ₹10,200 | 180 ₹5,400 Lowest |
| 10.00 | All as per Srl item N0 08 above for one socket out let 5 Amp controlled by one switch on independent board with other switch complete all as spd & directed | 60 | Point | 300 ₹18,000 | 350 ₹21,000 | 325 ₹19,500 | 380 ₹22,800 | 310 ₹18,600 | 480 ₹28,800 | 340 ₹20,400 | 230 ₹13,800 Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
10 Jun 2025, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
REPAIR REPLACEMENT OF INTERNAL WIRING INCLUDING FITTING AND FIXTURES AT OFFRS MD ACCN UNDER AGE EM OF GE NAGROTA
2025_MES_708228_1
CANO GEN-22/2025-2026
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAGROTA
Class D category b i
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹1 L
Yes
19 Aug 2025
15 May 2025
17 Jun 2025
15 May 2025
10 Jun 2025
29 May 2025
Amount
SCHEDULE 'A' PART -I Taking down carefully unserviceable aluminium point wiring (light, fan, socket bell or power) complete, (fittings such as switches, ceiling rose lamp holder, regulators, sockets, pendants) stacking at site and keeping in safe custody for taking credit complete all as specified & directed
Taking down ceiling fan any sweep, removing blades ,cleaning the fan completely for dust and dirt and hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook, rubber pad, nut bolts and washers etc, complete all as specified and directed
Taking down existing energy meters, keeping aside safely & refixing the same in its original position after making functional & after completion of point wiring/sub main wiring, complete all as specified & directed Note:- Small items required for fixing the electric energy meter at site shall be provided by the contractor and cost for the same shall be deemed to be included in the quoted rates.
Taking down existing electric water heater, keeping aside safely & refixing the same to its original position after servicing of the whole geyser/making functional and after completion of wiring work, complete all as specified & directed. Note: If any part found unserviceable during the refixing of water heater at site shall be provided by the contractor and cost for the same shall be deemed to be included in the quoted rates.
M&L for point wiring with PVC insulated sheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and in existing PVC conduit of any size , fixing acessories inculding sunken anodised pressed terminal box not less than 1.2 mm thick covered with 3 mm thick bakelite laminated sheet cover of suitable size with suitable size screws for mounting switches, sockets, regulators with and including 1.5 sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly for One light/fan point /bell point controlled by one switch switches/sockets/regulators complete all as specified & directed.
All as per Srl item N0 05 above but for one socket out let 5 Amp controlled by one switch on same board with other switch complete all as spd & directed
All as per Srl item N0 05 above for one socket out let 5 Amp controlled by one switch on independent board with other switch complete all as specified and directed
M&L for point wiring with PVC insulated sheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20 mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed terminal box not less than 1.2 mm thick covered with 3 mm thick bakelite laminated sheet cover of suitable size with suitable size screws for mounting switches, sockets, regulators with and including 1.5 sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly for One light/fan point /bell point controlled by one switch switches/sockets/regulators complete all as specified & directed.
All as per Srl item N0 08 above but for one socket out let 5 Amp controlled by one switch on same board with other switch complete all as spd & directed
All as per Srl item N0 08 above for one socket out let 5 Amp controlled by one switch on independent board with other switch complete all as spd & directed
S&F switch piano flush type 5 Amps single pole one way complete all as specified & directed.
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified & directed.
S&F switch socket combination 2 in 1 5 pin 5 /15 Amps flush type complete all as specified & directed.
S&F of ceiling rose surface type 65mm x 50mm 2 to 3 terminal complete all as specified & directed.
S&F Step type fan regulator 300 watt, 230 volts, 50 HZ, AC. Supply complete all as specified & directed.
S&F bell push piano type 5 Amps complete all as specified & directed.
S&F electric bell ding dong 230 volt AC complete all as specified & directed.
M&L for Concealed Point wiring using FRLS PVC insulated sheathed multi strand copper conductor cable 1100 volt garde 1.5 Sqmm FRLS PVC insulated sheathed multi strand copper conductor earth wire drawn IN and including PVC conduit ISI marked not less than 20 mm dia concealed in wall & surface on ceiling with all conduit fittings etc incl testing and making good to disturbed surface to match existing surface for One light/fan point /bell point complete all as specified & directed. (Note :- cost of modular boxes, Suitable modular switch base, frame & cover is included in quoted rate.)
All as per Srl item N0 18 above but for one socket out let 5 Amp controlled by one switch on same board with other switch complete all as spd & directed
All as per Srl item N0 18 above for one socket out let 5 Amp controlled by one switch on independent board with other switch complete all as spd & directed.
All as per item No 14 here in before but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15Amp socket out let controlled by one 15Amp switch on independat board complete all as specified & directed.
All as per item No 14 here in before but point wiring with 4 sqmm FRLS multi stranded copper conductor cable for main circuit and 4 sqmm cable as earth continuity conductor for controlled by two pin and earth plug and socket complete all as specified & directed.
S & F Modular snap switch SP one way 5/6 Amps suitable for 1 Module complete all as specified & directed.
S & F Modular Bell push ,SP 5/6 A suitable for 1 Module complete all as specified & directed.
S & F Modular socket 5 pin 5/6 Amps suitable for 2 Module complete all as specified & directed.
S & F Modular snap switch SP one way 15/16 Amps suitable for 1 Module complete all as specified & directed.
S & F Modular socket 5/6 pin 15/16 Amps suitable for 2 Module complete all as specified & directed.
S & F Modular Fan step Regulator electronic, 120 watts 2 Module complete all as specified & directed.
S & F Modular blanking plates 1 module complete all as specified & directed.
S&F electric bell ding dong 230 volt AC complete all as specified & directed.
S&F of ceiling rose 3 terminal complete PVC/Polycarbonate isolated boly complete all as specified and directed.
Supply in replacement, white / warm / cool white PVC LED fitting 1x20 watt complete with all accessories 230V 50 Hz complete as specified and directed.
Supply in replacement, white / warm / cool white LED channel of 5W, 230V frequency 50/60 Hz integral sleek extruded polycarbonate LED channel with white acrylic cover, Power Factor not less then 0.9 as complete as specified and directed.
M&L LED light fitting white / warm / cool white 1x9W bulk head luminaries IP 65 complete with all accessories including LED lamp 9 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz complete as specified and directed.
S&F decorative wall mounted luminaire in white / warm / cool white with & including 9 Watt LED lamp complete all as specified and directed.
S &F LED white / warm / cool white sleek surface round ceiling mounted decorative down light fitting with PC cover suitable for 1x15 watt complete all as specified and directed. Cat Part No HPLLEDRB15 (CW)S
S&F for lamp holder PVC/polycarbonate type with back plate incl 7 Watt LED Bulb suitable for batten fittings complete all as specified and directed.
Supply & fixing of LED Bulb warm / white / cool whtie 9 Watt complete all as specified and directed
Supply and fixing swing type wall mounting fan 400 mm sweep single phase AC 230/240V complete for wall mounting incl grouting, holding down bolts, nuts, and provision of flexible copper conductor cable 3 core 23/0.0076 size from ceiling rose to fan. complete all as specified and directed
Supply & fixing PVC Exhaust fan 250/300 mm sweep single phase AC 230/240V complete with louvers complete all as specified and directed
Supply & fixing Steel Body Exhaust fan 300 mm sweep single phase AC 230/240V complete with louver, complete all as specified & directed.
Supply and fix house service static electronic temper proof energy meter AC single phase static energy meter of accuracy class 1.0 rating 10-60 A, 240 V ,50 Hz static watthour meter, complete all as specified & directed.
S&F MCB single pole 5 to 32 Amps 10 KA 240 volts "C" series complete all as specified & directed.
S&F MCB SPN 40 A to 63 A 10 KA 240 volts "C" series complete all as specified & directed.
S&F MCB single pole 40/63 Amps 10 KA 230 volts "C" series complete all as specified & directed.
S&F TPN 40 to 100 Amp 4Pole 16KA 415 Volt with fixed magnetic and fixed thermal setting complete all as specified & directed.
S&F sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete incl taking out existing UNSV DB with MCBs complete all as specified & directed.
S&F sheet metal enclosure distribution board SPN 8 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete incl taking out existing UNSV DB with MCBs complete all as specified & directed.
S&F sheet metal enclosure distribution board SPN 4 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete incl taking out existing UNSV DB with MCBs complete all as specified & directed.
S&F MCCB 125A 4Pole 16KA 415 Volt with fixed magnetic and fixed thermal setting complete all as specified & directed.
S&F MCCB 100A 4Pole 16KA 415 Volt with fixed magnetic and fixed thermal setting complete all as specified & directed.
S&F sheet metal enclosure double door for distribution board factory made for MCB DB load link VTPN 4 way (when MCB's are to be used) with suitable size of busbar including complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down complete all as specified & directed.
Supply and fix electric water heater, storage type steel body with stainless steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified & directed.
S&F sheet metal enclosure double door for distribution board factory made for MCB DB load link Vertical TPN 4 way including MCCB 125 Amps, 16 KA 230 V suitable for MCCB as incomer, 125 Amp,4 pole. (when MCB's are to be used) with suitable size of busbar including 125 A MCCB as incomer 16 KA complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down all as directed by Engr-in-Charge at site incl taking out of exsing UNSV DB with MCBs, complete all as specified & directed.
M&L in replacement of sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked minimum 20 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 sq mm as earth continuity conductor connected to commen earth and earth dolly complete including taking down existing UNSV complete all as specified & directed.
M&L in replacement of sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked minimum 20 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 sq mm as earth continuity conductor connected to commen earth and earth dolly complete including taking down existing UNSV complete all as specified & directed.
S&F building security light luminaries eenergy saving and envirnment friendly long life LED light of 25W made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistanve of IK07, including MS Bracket light grade 25 mm dia, 1.2 m long bend in shape fixed on wall having an angle 120 degree, fixed with and suitable size nuts, bolts and washers etc including taking down of existing light fitting and complete all as specified and directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete all as specified & directed.
R.K. Works (BID ID -3319045)
M/S PRAJAPATI ENGINEERS (BID ID -3312170)
M/S J S ENGINEERS (BID ID -3312099)
Standard engineers (BID ID -3312379)
JAI DURGA CONSTRUCTION CO (BID ID -3312453)
AGGARWAL ASSOCIATES (BID ID -3312429)
M/S Chib Engineers (BID ID -3312476)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .