Loading…
Loading…
Tender Value
₹1.6 Cr
EMD Value
₹2.3 L
Closing Date
14 Jul 2025, 11:00 amClosed
Provision of CIB TIb for Bariarpur (BUP) and Dharah ( DRH) in mail line of Malda Division
MLDT_SNT_25-26_25_OT
MLDT_SNT_25-26_25_OT
Open
Works - General
365 Days
Maharajganj, Uttar Pradesh
₹0
₹2.3 L
20 Jun 2025
20 Jun 2025
A-Details are as under:
Item Breakup - A-Details are as under:
Supply of Central Data Controller ( CDC) with fully Numbers Redundent CPU units with relevant software as per RDSOspecification No. RDSO/SPN/TC/108/2019, ver-o.o or latest. This incudes Two CPU , Software, Rack , CDS ( Layer 3 switch) , KVM switch , Monitor speaker, 3 KVA online UPS for minimum one hour back up etc.
Installation, testing and commissioning of Central Data Numbers Controller ( CDC) with fully redundent CPU units with relevant software as per RDSOspecification No. RDSO/SPN/TC/108/2019, ver-o.o or latest. This incudes Computer , Software, Rack , CDS ( Layer 3 switch ) , KVM switch , Monitor speaker, 3 KVA online UPS for minimum one hour back up etc.
Supply of Platform Data controller ( PDC ) as per RDSO's Numbers Specification no. RDSO/SPN/TC/108/2019 Ver-0.0 or latest
Installation , testing and commissioning of PDC ( Platform Numbers Data Controller ) in suitable capacity 9U rack with 8-16 port LIU and rack mountable power socket . It should be integrated with existing ARECA Make IPIS system, SLDB, MLDB.
S u p p l y of LED Based Double faced Coach Guidance Numbers Display Board complete with acessories ( i.e. Pole, Clamp etc) as per RDSO's Specification No. RDSO/SPN/TC/108/2019, ver-o.o or latest
Installation, Testing and Commissioning of LED Based Numbers Double faced Coach Guidance Display Board in open area as per instruction of Site-in-Charge. All Fitting materials are to be supplied by the contractor. This includes Supply and installation of GI pole as per the technical specification including requirement of cement , sand stone chips etc as per site requirements. MALDA DIVISION-S AND T/EASTERN RLY
Installation, Testing and Commissioning of LED Based Numbers Double faced Coach Guidance Display Board under covered area as per instruction of Site-in-Charge. All Fitting materials are to be supplied by the contractor. should be integreted with existing system if required.
Supply & installation, testing & commissioning of Craft Numbers Terminal of complete for Network Monitoring. As per TS-1
Supply of LED Based Single faced Five Line Train Arrival / Numbers Departure display board as per RDSO Specificvation RDSO/SPN/TC/108/2019, Ver 0.0 or latest suitable clamping arrangement and all consumable materials including steel frame to be supplied by the contractor.
Installation and commissioning of LED Based Single faced Numbers Five Line Train Arrival / Departure display board as per RDSO Specificvation RDSO/SPN/TC/108/2019, Ver 0.0 or latest suitable clamping arrangement and all consumable maaterials including steel frame to be supplied by the contractor.
Supply of LED Based Single faced At a Glance display Numbers board as per RDSO Specificvation RDSO/SPN/TC/108/2019, Ver 0.0 or latest suitable clamping arrangement and all consumable materials including steel frame to be supplied by the contractor.
Installation and commissioning of LED Based Single faced Numbers At a Glance display board as per RDSO Specificvation RDSO/SPN/TC/108/2019, Ver 0.0 or latest suitable clamping arrangement and all consumable materials including steel frame to be supplied by the contractor.
Supply of Digital Clock suitable for Office Complex with Numbers GPS Synchronization in standalone mode as per Clause 6 of RDSO SPN TC 62/2008, (Rev 3.0) Amd. 2 or latest.
Supply of 4 Port Router as per RDSO Specification Numbers RDSO/SPN/TC/84/2008 Rev 0. with accessories as : 02 On Board GE,, 4 Port Serail WAN Interface Card , 2E HWIC SLOTS, 1 ISM SLOTS, 256 MB CF DEFAULT, 512MB RAM, IPBASE, 2 NOS V.35 Cable DTE MAke to SMART SERAIL 10 FEET LENGTH WITH REQUIRED CABLE & CONNECTION. Make:- CISCO MODEL No. ISR 4221/K9 or Similar . Make - CISCO Model: C8200L-1N-4T and accesories as per TS - II.
Supply and installation testing commissioning of 24 port Numbers Gigabit ethernet PoE Switch with 4 SFP Port along with supply of 4 SFM module, Brand D-Link (DGS-1210-24P). Acepted make: Cisco/Juniper/D-Link/Avaya/ Aruba/Netgear/HP etc.
Supply of Small Form- Factor Pluggable(SFP) as per IEEE Pair standard: IEEE 802.3z, Connector type: LC type, Wavelength(nm): 1310 nm, Fibre type: Single mode, Max cable distance: upto 20 km. Make & model DG-SA1133-20 DIGISOL/Netgear/Cisco or similar. ( to be suppied in pair )
Supply of 6 Fiber core armoured single mode Optic Fiber Kilometre cable as per GR/OFC-02/03 SEPT 2003 or latest. Make AMP/ DAX/ Legand/ Molex/Dlink
Supply of Layer 2 Managed switch (Minimum 8+2 ports Numbers manageable with 2 Nos. 10/100/1000 Mbps+ 2 Gigabit SFP port with optical module (2 Nos.) (LX/LX10) and 8 Nos. fast ethernet port, POE, (supports IEEE802.3 at Power budget 140 watt minimum, all 8 ports must support 8 APssimultaneously), Make D-link/Digisol/Cisco. make model DG-GS1510HPL DIGISOL / CISCO/JUNIPER or superior.
Supply , installation of Fiber Distribution Management Numbers System / 12 Port LIU fully loaded with 12 simplex SC couplers and 12 SC connectors with splicing placing tray inside , 19 inch rack mount FMS, Make Digisol, D-link, DAX, Hanutech
Supply of 40 mm dia permanently lubricated HDPE Kilometre Telecom duct (with cord) , as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev. 2.0 or latest. ammendment. following items are to be supplied (a) end plug-2 nos (b) cable sealing plugs -02 nos (c) end plugs to be provided along with drum 2-nos. MALDA DIVISION-S AND T/EASTERN RLY
Laying protective works including pulling of mono-mode armoured OFC cable ( 24/6 fibres) through duct in trenches and as advised by site engineer. Note: (1) The contractor will take over the OFC cable from Railway store to site of work duly checked the contuinity of each fiber from end to end. (2) before & after laying of optical cable through duct, continuity test from end to end of each fiber to be made by the contractor to ensure availability of all 24 fibre duly certified by the site engineer.
Supply & Installation of OFC Termination box as per TEC Numbers Spec No. TEC/GR/TX/FTB-02/APR-2010 with latest ammendment including all miscellineous and consumable for fiber splicing. It should have the capacity to terminate 02 No. 24OFC Cable through separate entry holes & to take out & terminate 6 or 24 pigtails through separate exit holes. Make: JT Optics/Raychem/Aras Telecom/ D-Link OR BETTER
Supply of armoured SC/PC-LC/PC pathch cord ( 3 mtr) Numbers Make: R&M OR BETTER
Supply of armoured SC/PC-LC/PC pathch cord ( 3 mtr) Numbers Make: R&M OR BETTER
Supply of armoured SC/PC-SC/PC pathch cord ( 3 mtr) Numbers Make: R&M OR BETTER
Supply of XLR Cable Connector ( Male & Female) with 5 Pair mtr
Supply of High Graded MICROPHONE Cable without XLR Metre Connector
Supply and installation of complete indoor wiring of 19 Numbers inch (42U) conered rack of size 2035 mm x 600 mm x600 mm ( Approx.) The rack shall be complete with all fittings for housing SDH equipments , Primary Muxes , DDF, MDF using crone module and others equipments like runway ladders etc. Completely wired and equipped with integrated protection modules for all channels as per technical specifications and other stipulations of tender document. It should be possible to lock all the equipment with only order wire telephone remaining out side the rack
Splicing and/or termination of OFC cores as per directive CORE of Rly.
Supply of STP (shielded Twisted Pair) Data Cable Make Kilometre Siemen/Systemax/ Panduit/ Tyco/Krone/AMP or similar
Supply, Installation, testing and commissioning of 2 core Kilometre screened /shielded multistrand PVC insulated wire (24/0.2mm dia) for speaer load Line.
Supply of screened 5 pair ( 10 core ) colour coded and Metre twisted Data communication cable each code of Cpopper conductor of 0.20 mm diameter (7/.20mm) abC 9 Annealed bare copper 0 & polythin Insulated . Tollerence in dimension s should be within +-10%
Supply of Power Cable 3 core 2.5 Sq.mm Multi strand Metre (36/0.3 mm dia) Cable a per IS 694:1990 reaffirmed 1995 or latest suitable for railway electrification area shall be reputed make like FINOLEX/Delton/ LAPP .
Supply of Serial Cable 3 mtr for intercae to G.703 / V.35 Numbers Modem as per requirement at site
Supply and fixing of PVC conduit pipe 25 mm with Kilometre accessories such as bend,tee, coupling, elbow, saddle, clamp, screw, PVC/ wooden plugs etc. on walls,angle or on rail of platform shelter etc. MS clamp made of 3 mm MS fl at to bemanufactured and supplied and fi xed to clamp the PVC pipe or angle/ rail runof platform shelter. Th e clamp should be painted with red oxide primer over which two coats of aluminum paint to be given. Where ever necessary jumper holes to be made in wall and above PVC pipe threaded and wall to be repaired to its original condition.
Supply of PVC conduit pipe 50 mm dia MALDA DIVISION-S AND T/EASTERN RLY
Fixing of PVC conduit pipe 50 mm dia on wall /shed Kilometre including supply of all fixing materials such as bend,tee, coupling, elbow, saddle, clamp, screw, PVC/ wooden plugs etc. angle or on rail of platform shelter etc. MS clamp made of 3 mm MS fl at to bemanufactured and supplied and fi xed to clamp the PVC pipe or angle/ rail runof platform shelter. Th e clamp should be painted with red oxide primer overwhich two coats of aluminum paint to be given. Where ever necessary jumperholes to be made in wall and above PVC pipe threaded and wall to be repairedto its original condition.
Laying & drawing of Data Cable & power cable/OFC Kilometre through PVC conduit through wall/structure of platform shed / underground through GI/DWC/HDPE pipe etc. This includes laying of PVC pipe, DWC pipe, GI pipe etc.
Supply of GI pipes of 50 mm dia Medium quality to Metre Specn.No-ISI239(part-1) 1990 & galvanised to specn. Is 4736-1986 or latest.Insp.Consignee.
Laying of GI Pipes 50/65/100 mm dia over cement/girder Metre bridges/FOB/COP/walls platforms etc as per the instruction of site incharge. Necessary suitable MS clamps are to be provided with all materials except GI pipes are to be arranged by the contractor. GI Pipe to be supplied by RLY Store.
Supply of Cable Tray Systems And Cable Ladder Systems Metre (Overhead Power Cable Tray) DIMENSION Wall thickness (in mm) 2 Width (in mm) 200 mm Cable tray system height (in mm) 75 . (Overhead Power Cable full required components for L-type iron angle for fitting and fixing on the wall with nut bolt ( all telecom cable inside the Cable tray) all materials should be supplied by Contractor.
Installation & fixing of cable tray , laying of cable & Metre drawing inter connecting cable e Tray Systems And Cable Ladder Systems.
Conceal Wiring with cutiing the wall and repair in 04 Inch Metre width. This includes supply of Concelling pipe/channel also.
Supply, Installation and commissioning of Class-B Set encapsulated type Lightning current arrestor. The parameter shall be as per RDSO specifi cation No. RDSO/ SPN/TC/98/2011, Rev.0, Amndt. 1, or latest, with visual indication and potential free contacts.
Supply of basic material to construct unit maintenance Lot free earth as per RDSO Specs. No. RDSO/SPN/197/2014 or latest and conforming to RDSO Drg.No.SDO/RDSO/E&B/001 . It consist of following: (a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. ( c ) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable MALDA DIVISION-S AND T/EASTERN RLY
Installation of Unit Maintenance Free Earth as per as Set supplied in above item. It includes ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 micrones to made requirement of under writer's laboratories (UL) 467- 2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specn.No.RDSO/SPN/197/2014 or latest and conforming to RDSO Drg.No.S DO/RDSO/E&B/001 or latest. 60 month warranty should be given by the firm.
Supply of GI FLAT (SPEC. NO. 226 STD or latest) of size 35 Numbers mm x 6 mm with length 5 mtr with holes of 12 mm dia at both ends as per CSTE/ER'S DRG. NO. S&T-1/2007 (or latest).
Fixing of earth electrode including laying and installation Numbers of GI flat of size 35 mm x 6 mm with length 5 mtr or as per extant practice of Eastern Railway. As per CSTE/ER'S DRG. NO. S&T 1/2007 for apparatus cases, signal post & other equipment as per instruction of site engineer. Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required for installation to be supplied by the contractor except earth electrodes and MS flat. Note: -all materials required to be arranged by the contractor except 2 core cable will be supplied by the railway.
Cutting of all types of platforms/Road crossing and Metre trenching and excavation to a width and depth of 300 mm x 300 mm, laying of DWC/HDPE/GI pipe in the trench and refi lling and concreting it after wards as per original condition. In hard rocky ground area, cables will be laid normally on layer of soft earth of 0.05 meter thickness previously deposited at bottom of the trench. The cutting to be filled and finished with cement/concrete (Including cutting of tiles neatly , removing slabs/tiles if any. Filling the trench after cable laying and restoring the surface with similar materials to match existing floor/Platform as per instruction of site incharge.. MALDA DIVISION-S AND T/EASTERN RLY
Transportation of HDT Machine with accessories including Metre handling of stores materials , preparation of sites and boring for placing of 110 mm dia HDPE Pipe for crossing of S&T cables together a bridges/culverts, puccu road/ crossing, boring trenc shall be minimum 3 (three) meter below the river bed and one(01) meter below the track /road /puccu road crossing area. This includes supply of accessories for HDPE pipes, including cost of fuel and all other items etc. which will be required for laying of cable through it. the work shall be executed as per instruction of site engineer. HDPE PIPES to be supplied as per RDSO SPEC. contractor shall provide all material required for boring and adequate nos. of labours for propoer laying of cables into the bore. cable shall be laid cautiously so that it should not get damage due to handling & pressure on cable. Boring up to the length of 150 meters. Preparation of site for Horizontal Boring shall be carried out in presence of Railway Representative.
Supply of Media Converter Single Mode, Double Fibre, Numbers Model:FCAT/01/SM 15/SC/CAD, make Mrotek or similar.
Supply, Instsallation and fixing of wall-mount 9U Rack Numbers with Transparent Toughened Glass Front Door, fan for heat dissipation, support for cable entry from top or bottom, power distribution unit, cable manager, secure locking of front glass door, compitiable with standard 19 inch equipment with all accessories. Make: HCL/Bestnet/D-Link or Similar.
Supply BOSCH/L'Acoustic/Renkus Heinz or superior. All necessary accessories required for installation will be supplied/provided by contractor. Make & Model: LB UC30- D1 or similar.
Installation & commissioning of Wall Mounting Speaker 20 Numbers watt minimum BOSCH/L'Acoustic/Renkus Heinz or superior. All necessary accessories required for installation will be provided by contractor.
Supply installation and commissioning of versatile PA horn Numbers speaker 30W with 100V LMT Taps 15, 10 and 5W complete with fixture of make Philips/Ahuja/AKG. Payment Terms: 100% after commissioning.
Supply Installation Commissioning of 700 Watt Amplifier Numbers make : Ahuja Model 24-02-2023 SSA7000or Similar
Supply of Microphone model 59XLR, make Ahuja or Numbers similar.
Supply of Microphone stand (DGT) with XLR chord Ahuja Numbers or higher
Supply & Installation of 19" Rack 17U with power strip Numbers and all fitting accesssories for housing of network equipment.
Supply, testing of 1.1/1.0 KVA Offline UPS. Make& Model : Numbers APC BX1100C-IN or better. Total 16009100.00
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .