Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹34.9 LAccepted-AOC SHOP NO 8 RAJA PRESIDENCY PANCHWATI NASHIK 422003 MAHARASHTRA | NASHIK | NASHIK | MAHARASHTRA | 422003 | L-1 | Accepted-AOC Successful Lowest L-1 Bidder | |
| 2 | L2₹36.9 L+₹2.0 L (5.80%)Rejected-Finance | L2 | Rejected-Finance Unsuccessful Lowest Bidder |
Tender Value
₹38.1 L
EMD Value
₹76,185
Closing Date
29 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sr.Manager (Engg.-Elect.)
Airports Authority of India,Room No.-002,ATS Complex,Sutar Pakhadi Road,Andheri (East),Mumbai - 400 099.
Replacement of Old AHUs and allied works at ATS Complex, C.S.M.I.Airport, Mumbai - Phase - III
2023_AAI_178078_1
MUM/ATS/ENGG-E/eNIT-03/2023-24
Open Tender
Electrical Works
Works
90 days
AAI, ATS Complex, C.S.M.I.Airport, Mumbai
As per PQ Performa and Tender document
4 documents required · 4 mandatory
₹1,180
₹76,185
8 Feb 2024
15 Dec 2023
1 Jan 2024
16 Dec 2023
29 Dec 2023
16 Dec 2023
16 Dec 2023 - 27 Dec 2023
Amount
Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal air handling units made of 25 mm. thick panels consisting of pre plasticized G.I. casing of thickness 0.8 mm. outside layer and 0.8 mm. inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure of 50 mm.W.G., minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm.) cooling coil of 6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor suitable for 415 ± 10% volts, 50 Hz, 3 Phase AC supply, drain connections, stainless steel (18 G) drain pan with PUF insulation, 150 mm. dia. dial type pressure guages (2 nos.) and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement, etc. complete as per specification and of following capacities:-
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. a) Thickness 1.00 mm. sheet
Supply, Installation, Testing and commissioning of Starter panel for up to 15 HP VFD Drive wall/floor standing,compartmentlized double door totally enclosed dust and vermin proof fabricated with 14 G CRCA sheet,Powder coated of suitable size Panel should have detachable gland plates for incomer switch and cable chamber and having locking arrangement,6 inch cooling fan with grill and filter including supplying and fixing following switchgear,making connections,earthing, etc. as per IE Rules complete as required 1.Incomer: 63 A,3 Phase,25 KA MCCB with Rotatory Handle,ELCB and Multifunction meter - 1 No. 2.Main / Delta power contector 32 A, - 5 Nos. 3.R,Y,B Indication LED Lamp - 3 Nos. 4.MVK 32 , 240V AC over load Relay with base, 9 - 15 A - 1 No. 5.Digital Ammeter and Voltmeter - 1 Set. 6. ON,OFF, TRIP, RUN Indication Lamp - 4 Nos. 7.Star Delta Timer A 1DS,240 V A.C or equipment - 1 No. 8.Changover relay with base - 1 No. 9.Indication lamp - LED Type one no. each,for ON/OFF & TRIP, STOP / START - PUSH BUTTON - 2 Nos.
Supply, Installation, Testing and commissioning of Motor control centre - wall/floor standing, 15 HP VFD Panel suitable to operate on 415 ± 10% volts, 50 Hz., 3 Phase AC including earthing, etc. as per IE Rules complete as required
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of MS 'C' class chilled water piping inside the building as per IS : 1239 (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastomeric nitril rubber of class 'O' insulation applied by adhesive confirming to standard specifications and finally applying 0.63 mm aluminum sheet cladding complete with type 3, grade 1 roofing felt strip (as per IS: 1322 as amended upto date) at joints and repairing of damage to building etc. as per specifications and as required.
a) 50 mm. dia. (25 mm. insulation)
b) 65 mm. dia. (25 mm. insulation)
Supply, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water duly insulated to same specifications as the connected piping and adequately supported as per specifications.
a) Up to 65 mm. dia. Butterfly valve (manual) with CI body SS disc, nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water circulation complete with flanges, bolts, nuts, gaskets, etc. confirming to specifications as required.
b) Up to 65 mm. dia. Y-Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled circulation including insulation as specified.
S.I.T.C. of 40 mm. ball valve for supply and return chilled water pipes i/c tightening, etc. complete as required.
Supply, Installation, Testing & Commissioning of Three way mixing valve Proportionate type with modulating Actuator suitable for Temp. of -25LC to 130LC. This assembly shall have 2 nos. Universal controller operating on 24 Volts AC Supply having analogue output 0 to 10 Volts DC & activated by duct temperature sensor and differential pressure sensor installed in return air duct of measuring range -15°C to 65°C including complete wiring etc as required. a) 50 mm.
Supplying, fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring. The damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
a) Fire damper
b) Actuator
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges, etc. as per specifications.
Supply and laying of following sizes of XLPE insulated (heavy duty), aluminum conductor cables, aromoured power cable of 1.1 KV grade conforming of IS 7098 part-I, amended upto date and laying on walls/ceiling / cable tray from main panel boards to AHUs and fixing arrangements, etc. as per specifications. a) 4C X 10 Sq.mm.
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. a) 4C X 10 Sq.mm.
Supplying and fixing of 50 mm. dia. Medium duty class 'B' GI pipe duly insulated with following closed cell elastomeric nitril rubber of class 'O' insulation applied by adhesive confirming to standard specifications and finally applying 0.63 mm. aluminum sheet cladding complete with type 3, grade 1 roofing felt strip (as per IS: 1322 as amended upto date) at joints and repairing of damage to building, etc. as per specifications and as required.
Supply and fixing of 100 m dia flexible duct with insulation complete as required.
Dismantling of existing old AHUs from the AHU rooms. The job include dismantling of pipe lines and AHUs enclosure and shifting of AHUs at the ground floor in the desired location as required.
Providing of 22 TR portable temporary air - conditioning units of (multi TR capacity) as required at the specified locations of ATS complex during the removal of old AHU and installation of new 04 nos. AHU in AHU rooms at different floors of ATS Complex. The job includes supply and fixing of AC units at desired locations,gas charging and removal of ACs after completion of shut down.
Dismantling of existing UVGI (Ultra violet germicidal irradiation ) system i/c all accessories , power and control cables / wiring from existing AHUs and ITC of the dismantled UVGI system in newly installed AHUs, etc. as required.
Air-O-Mec Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .