Executive Engineer (EnM)M-VIII
C-2A Block Janakpuri BPS New Delhi-110058
SITC of LT Panels and Starters and other electrical equipmet at BE Block BPS in Hari Nagar in AC-28.
2025_DJB_275034_36
e-NIT No.06 / (EnM)M-VIII/ 2025-26
Open Tender
Miscellaneous Works
Works
30 days
C-2A Block Janakpuri BPS New Delhi
Please refer Tender Document
3 documents required · 3 mandatory
₹500
Yes
DJB Account No. 50448339804
₹11,300
Yes
24 Jul 2025
5 Jul 2025
11 Jul 2025
5 Jul 2025
11 Jul 2025
5 Jul 2025
LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection. Each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipment’s of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire, size 1400MM x1200x375mm. Having following components of approved make.
MCCB 415V, Four Pole High breaking capacity 50KA 50Hz,320Amp with spreader - Make L&T/Siemens
MCCB 415V, TP 3phase High breaking capacity 50KA 50Hz,100Amp with spreader - Make L&T/Siemens
MCB Single pole 6Amp. Make L&T/Siemens
MCB Triple pole 63Amp. Make L&T/Siemens
MCB Triple pole 32Amp. Make L&T/Siemens
Over load relay 36-60 amp Make: L&T/Siemens
Over load relay 4.5 -7.5 amp Make: L&T/Siemens
Digital Amp. Meter Make AE/L&T
Digital Volt Meter-Make AE/L&T
Motor protection RelayM-10 type Make: L&T/Siemens/Protech
Power contactor 220V 3phase 40Amp. Make L&T/Siemens
Power contactor 220V 3phase 70Amp. Make L&T/Siemens
Power contactor 220V 3phase18Amp. Make L&T/Siemens
Star delta timer on delay make: L&T/Siemens
Indicating lights LED type RYB & On/OFF Make: L&T /Siemens
Current Transformer300/5& 100/5 Make AE /Advance/Saviour
On load change over switch 200Amp. Open execution type Make:L&T/HPL
Supply of 25 sq mm Single core Copper Cable. Make: Havells/polycab /Grandlay/Finolex/ any other make approved by DJB
Loading, unloading by crane or heavy labor and cartage up to site cleaning & dressing the surface for
Installation of the panel at site on base frame, laying of cable, termination of cable both incoming &out going side
Testing & commissioning of panel, as per required parameters with relevant IS. testing of the panel prior to switching on as follow:- i) Continuity and earth testing ii) Meagering of all equipment’s for phase to phase, neutral to body, neutral to earth and phase to earth. iii) checking for all tightness of nut and bolts iv) Alignments of doors etc. Interlocking tests. All function tests
DAYAL TRADERS (BID ID -1598476)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .