Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹30.3 L+₹54,300.60 (1.83%)Rejected-Finance | L2 | Rejected-Finance Bidder rejected | |
| 3 | L3₹30.8 L+₹1.1 L (3.77%)Rejected-Finance | L3 | Rejected-Finance Bidder rejected | |
| 4 | L4₹31.5 L+₹1.8 L (6.06%)Rejected-Finance | L4 | Rejected-Finance Bidder rejected | |
| 5 | L5₹32.2 L+₹2.5 L (8.40%)Rejected-Finance KHOBLETENG ZEMITHANG PO ZEMITHANG PS LUMLA DIST TAWANG ARUNACHAL PRADESH PIN 790 106 | ZEMITHANG | TAWANG | ARUNACHAL PRADESH | 790106 | L5 | Rejected-Finance Bidder rejected |
Tender Value
₹29.7 L
EMD Value
₹59,400
Closing Date
3 Sept 2024, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL BIRENDRA SINGH
GE 859 EWS, C/O 99 APO
REPAIR AND MAINT OF INTERNAL ELECTRIFICATION CUM ACCESSORIES AND OTHER CONNECTED WORKS AT ENGR REGT, IFSU, JAK RIF, CISU, APJD JONG FD REGT AND MARATHA GROUND OF AGE E/M UNDER GE 859 EWS
2024_MES_664307_1
8827/E8
Open Tender
Civil Works
Item Rate
270 days
TAWANG
PLEASE AS PER NIT AND TENDER DOCUMENTS
6 documents required · 6 mandatory
₹0
₹59,400
Yes
2 Dec 2024
6 Jul 2024
5 Sept 2024
6 Jul 2024
3 Sept 2024
20 Jul 2024
Amount
Taking down carefully aluminium point wiring (light, fan, socket or power) complete and making good disturbed surfaces of walls, floors, etc. all as directed.including taking down fittings such as switches, ceiling roses, regulators, sockets,lamp holders, ceiling fittings, bulk head fittings, tube light fittings etc.
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC casing capping of size not less than 20mm on surface of wall including provn of PVC box of suitable size for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm all as specified and directed.One light/fan/call bell point controlled by one switch one way 5 Amps
All as per Sl Item no.2 but with One 2/3 pin socket outlet 5Amps on independent board.
All as per Sl Item no.2 but with One 3 pin socket outlet 5 Amps on the same board with other switches.
All as per item No 2 above but one switch socket combination 15 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm.
S&F switch piano flush type single pole one way switch 5 Amps.
S&F switch socket combination 2 in 1, 5 Amps flush type.
S&F switch socket combination multipurpose 5 A/16 Amps,5 in1,flush type.
S&F ceiling rose surface bakelite 3 terminals 65x50mm all as directed.
Supply & fix Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 18 Watt. Make : Havells. Cat No-LUMILINENXTBS18WLED830SPCWH or equivelent WIPRO/CG/Bajaj/Philips
Supply & fix Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 10 Watt.Make : Havells. Cat No-LUMILINENXTBS10WLED830SPCWH or equivelent WIPRO/CG/Bajaj/Philips
Supply and fix in repair Modular switch 1way 6A,1module
Supply and fix in repair Modular socket, 6A-2/3 pin combined 2 module
Supply and fix in repair Modular socket, 6A/16A-2/3 pin combined 2 module
M&L for Repairs to recessed mounting/ ceiling light fitting/switch,socket of any type/wattageincluding replacing all the unserviceable parts such as, driver, lamp holders all as directed. Note: (i) The unit rate quoted shall be deemed to include for replacement of worn out bolts, nuts, screws ,washers, partly wiring,driver etc wherever required.
S&F in repair of switch piano flush type single pole one way 5 Amps complete all as specified & directed.
S&F in repair of switch socket combination 2 in 1, 3 pin 5 Amps flush type complete all as specified & directed.
S&F in repair of Switch socket combination multipurpose 5/16 Amps, 5 in 1, 4 / 5 hole flush type complete all as specified & directed.
S&F in repair Lamp holder angle type made of PVC/Polycarbonate with back plate.
Supply & fix Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 18 Watt. Make : Havells. Cat No-LUMILINENXTBS18WLED830SPCWH or equivelent WIPRO/CG/Bajaj/Philips
Supply & fix Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 10 Watt. Make : Havells. Cat No-LUMILINENXTBS10WLED830SPCWH or equivelent WIPRO/CG/Bajaj/Philips
Supply & fix in repair Ultra modern recess mounting luminaire with high performance LEDs, 36 watt suitable for mounting with Armstrong/Grid ceiling. Make : Havells. Cat No-PLANO2X2PLR36WLED830TAPS or equivelent WIPRO/CG/Bajaj/Philips
Supply & fix in repair Square recess mounted LED edge lit slim downlight 15 watt with die-cast aluminum housing finished in premium white powder coating. Make : Havells/ WIPRO/CG /Bajaj/ Philips
Supply & fix in repair Slim design LED recessed round polycarbonate housing down lighter 18 watt with superior light output and integral driver. Make : Havells WIPRO/CG /Bajaj/ Philips
Supply and fix in repairs of 15 watts, 230 V LED light fitting for Building security LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07. Make : Havells Cat Part No. VILUMINASL15WLED757SASYBOPC
S&F in repair of MCCB 125 amps 4 pole 16 KA 415 volt complete including taking down all as specified & directed.
S&F in repair of MCCB 100 amps 16 KA 4 pole complete all as specified & directed.
S&F in replacement of MCCB 63 amps 10KA complete all as specified & directed.
S&F in repair, sheet metal enclosure distribution box suitable for MCB'S 4 way TPN 415 volts with 200 Amps rated bus bar double door complete including connecting up all as specified and making good distrubed surface.
All as per item No. 29 above but 8 way SPN with 200 Amps rated bus bar , 240 volts.
All as per item No 29 above but 4 way SPN with 200 Amps rated bus bar , 240 volts.
S&F in repair MCB Single pole, 240 volts 5 to 32 Amps 10 KA rupturing capacity, C series.
S&F in repair MCB Single pole & neutral 240volts 5 to 32 Amps, 10KA rupturing capacity, C series.
S&F MCB triple pole 415 volts 25 to 63 Amps 10KA rupturing capacity, C series.
Taking down sub main wiring of any size complete all as specified and directed.
M&L for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 4 sq mm drawn through suitable size of non-metallic PVC rigid conduit with 4 sqmm copper conductor cable as earth conductor of 4.0 sq mm and conduit accessories fixed up in surface including connecting up complete all as specified and directed. Note : Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
All as per item no 36 but cable size of 6.0 sqmm. Note : Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
M&L for sub main wiring with Four single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 6 sq mm drawn through suitable size of non-metallic PVC rigid conduit with 6 sqmm copper conductor cable as earth conductor of 6.0 sqmm and conduit accessories fixed up in surface including connecting up complete all as specified and directed.Note : Four run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
All as per item no 38 but cable size of 10.0 sqmm. Note : Four run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
Taking down Exhaust fan of any size type and make after disconnecting the electrical connections ,cleaning, servicing , greasing removing and replacing all the unserviceable spare ,painting with two coats of synthetic enamel paint by means of suitable spray gun after cleaning and prepairing the suface including writing the MES No. ,fixing the same back to the original location all as directed. Note for item No. 65 & 66 : (i) All the replaced spare for unserviceable spares will be measured and paid separately (ii) The rate quoted shall be deemed to include the cost of painting and minor spares such as split pin , screws washers etc.
Supply only ball bearing suitable for exhaust fans 300/450/600 mm dia sweep.
Supply only Capacitor 4 mfd for exhaust fans.
Supply only gun metal bush suitable for ceiling fans of 1200/1400/1500 mm sweep.
Supply only twin core flexible wire 1 Sqmm for connecting up ceiling fans, exhaust fans/wall mounting fan etc.
Taking down old burnt out copper winding wire from exhaust fan of any sweep and rewinding by using the same gauge of copper wire super enameled including heating and varnishing,cleaning, servicing,greasing ,refixing at siteand testing for smooth functioning complete all as specified & directed.
Supply only modular white cover plate with frame, 2 module ISI marked complete all as specified and as directed.
Supply only White cover plate with frame, 4 module ISI marked complete all as specified and as directed.
Supply and fix White cover plate with frame, 6 module ISI marked complete all as specified and as directed.
Supply only White cover plate with frame, 8 module ISI marked complete all as specified and as directed.
Earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground surrounded from all sides by 15cm thick and packed layer of charcoal dust and conmmon salt filling in alternate layers connected to and including GI earth wire 4.0 mm dia upto 7.5 mtr by means of bolts, nuts, check nuts and washers, and protected by light grade 20 mm dia and connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel wire mesh, RCC pit cover 50mm thick with 10mm dia reinforcement 100mm c/c and PCC chamber pit with P C C 1:2:4 Type C2 (including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 metre and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009
S&F in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire.
S&F in repair for 20 mm bore galvanised steel water tubing medium grade with all fitting laid in trenches complete all as specified.
Repair / servicing including trouble shooting /repair of geyser 25 to 50Ltrs capacity checking of serviceability of individual parts such as thermostat, heating element, pressure release valve, inlet/outlet connections etc, replacing worn-out fasteners and defective components and testing including taking down the geysers and refixing the same after repairs. Note : Spare parts including replacement will be measured and paid separately under relevant item. Rate quoted shall include replacement of worn-out fasteners.
Supply only heater coil of geyser all 1.5 KW as per existing make / model / size conforming to relevant IS.
All as per item No 54 above but 2.0 KW.
Supply only thermostat for any type /make/capacity of geyser .
Supply only pressure release valve 15mm dia with new one for any type /make/capacity of geyser .
Supply only PVC flexible connection of 15 mm dia 600 mm long with check with new one suitable for cold/hot water connection of geysers.
Supply and Fix 20 mm Non return valves, cast copper alloy, for GI Pipes pipe all as directed
Taking the copper or steel container carefully from the geyser, descaling, rectifying leakage by braising, resetting the insulating (glass wool), testing for the required pressure replacing rubber gaskets, worn-out fasteners etc,. with new ones complete all as directed by Engineer in charge.
Supply and Fix Base plate of Water Heater of 25 / 50 Ltrs Capacity all as directed
Supply only Indicator Lamp of RED / GREEN Suitable for Water Heater
S&F in replacement of Single pole and neutral Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps, 240 Volts, AC,50 HZ, completete all as directed and specified, including taking down old unserviceable plug socket and offering for credit.
Supply and fix PVC insulated copper cable 2.5 sqmm 3 core
Supply & lay 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc. of size 25 mm
Supply & fix driver of any type light fitting /path light of any watt/make.
M/S KESANG CONSTRUCTION (BID ID -3077654)
M/S L G BUILDERS (BID ID -3077666)
DEOGRATIES SEMPER AMA ASSOCIATE (BID ID -3077677)
M/S L.N. TRADERS (BID ID -3077690)
M/S YESHI THINLEY (BID ID -3077703)
M/S ACE BUILDERS (BID ID -3077715)
MS TD CONSTRUCTION (BID ID -3077736)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .