| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹2.7 L+₹28,296.80 (11.7%)Accepted-Finance NITIN ENGINEERING INDIA SANDEEP YADAV CONTRACTOR ISHWAR CONTRACTOR SHREE SALASAR ASSOCIATES | L2 | Accepted-Finance OK | |
| 3 | L3₹3.0 L+₹56,847.80 (23.6%)Accepted-Finance | L3 | Accepted-Finance Ok | |
| 4 | L4₹3.4 L+₹96,575 (40.0%)Accepted-Finance | L4 | Accepted-Finance Ok | |
| 5 | Rejected-Technical | - | Rejected-Technical Reject due to Not compiled Technical specification as per Tender documents |
Tender Value
Refer Docs
EMD Value
₹6,200
Closing Date
21 Sept 2021, 1:00 pmClosed
EE EnM HP I
DELHI JAL BOARD GOVT OF NCT OF DELHI OFFICE OF THE EXECUTIVE ENGINEER EnM HP I HAIDERPUR WATER WORKS DELHI 110085
Providing and fixing of exhaust fan with allied works at RWPH HPWWI
2021_DJB_208314_1
NIT No. 9 Item no. 1
Open Tender
Miscellaneous Works
Works
30 days
Delhi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹6,200
Yes
8 Oct 2021
14 Sept 2021
21 Sept 2021
14 Sept 2021
21 Sept 2021
14 Sept 2021
Supply of heavy duty exhaust fan size 450 mm/18 Inch, 1400 RPM- Gray(O) industrial type. Make: Havells/Crompton/Any DJB approved make
Supply of heavy duty exhaust fan size 600 mm/24 Inch, 900 RPM- Gray(O) industrial type. Make: Havells/Crompton/Any DJB approved make
Supply of Air Circulator turbo force 450 mm wall fan Make: Any DJB approved make
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing,commissioning etc. as required. (A). For 450 mm sweep. DSR 1.50.1
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A (DSR 1.1.1)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required (DSR E&M 2018 -- 1.7.1) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire DSR 1.7.1
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required (DSR E&M 2018 -- 1.7) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire DSR 1.7.3
Supplying and fixing of 6 Pin 15/16 amp. Socket piano type switch/ socket on the existing switch box/ cover including connections etc. as required. DSR 1.23.5
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 Way Double Door. DSR 2.3.4
Supply of MS strips of 6mm thickness, width 75 mm and length of 250 feet.
Fabrication and Fixing of Ms frame as per above existing exhaust fans with the help of Gas cutter machine and CC work as per site requirement.
Nut, Bolts and Washer and other accessories.
Supplying and fixing of 63 amp rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR 2.12
Un-installation/dismantling of Exhaust Fan from the existing slots
Nitin Engineering India
GOGIA BROTHERS
AQUA GASEOUS CONTROLS (INDIA)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .