Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹149.5 CrAccepted-AOC L 87 STREET NO 7C MAHIPALPUR EXTENSION NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | ₹149.5 Cr | L1 | Accepted-AOC Due to L1 rate quoted. |
| 2 | L2₹151.0 CrRejected-Finance 401 THE GRAND MALL OPP STATE BANK ZONAL OFFICE S M ROAD AMBAWADI AHMEDABAD 380015 | AHMADABAD | GUJARAT | 380015 | ₹151.0 Cr | L2 | Rejected-Finance Other than L1 rate quoted. |
| 3 | L3₹169.7 CrRejected-Finance | ₹169.7 Cr | L3 | Rejected-Finance Other than L1 rate quoted. |
| 4 | L4₹171.9 CrRejected-Finance PLOT NO 65 SECTOR 18 OPP HIPA SARHAUL GURUGRAM 122 001 | ₹171.9 Cr | L4 | Rejected-Finance Other than L1 rate quoted. |
| 5 | L5₹174.2 CrRejected-Finance | ₹174.2 Cr | L5 | Rejected-Finance Other than L1 rate quoted. |
| Sl No | Description | Qty | Unit | VISHAL INFRASTRUCTURE LTD L5 | Varindera Constructions Limited L4 | Dineshchandra R.Agrawal Infracon Pvt.Ltd L2 | NSC Projects Pvt. Ltd. L1 | VRC Constructions (India) Limited L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00Note: (i) Please refer Schedule 'A' Notes given on serial page No. 26 to 48 of tender documents. | ||||||||
| 2.00BUILDING WORKS | ||||||||
| 2.01 | Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part-I brought forward from serial page No. 48 to 51. | 1 | Lump sum | 63,00,50,000 ₹63.0 Cr | 46,19,79,693 ₹46.2 Cr | 41,75,00,000 ₹41.8 Cr | 48,49,94,004 ₹48.5 Cr | 51,00,00,000 ₹51 Cr |
| 2.02 | Sch 'A' Part-I (Sec-B) (PRE ENGINEERED BUILDING WORK)
Design, supply and erect pre-engineered building steel structure of WSI FLIGHT HANGER with annexe (Double Storey) complete all as specified and directed. | 1 | Each Block | 4,88,59,313 ₹4.9 Cr | 12,23,00,000 ₹12.2 Cr | 10,50,00,000 ₹10.5 Cr | 9,87,36,452 ₹9.9 Cr | 12,00,00,000 ₹12 Cr |
| 2.03 | Sch 'A' Part-I (Sec-C) (PRE ENGINEERED BUILDING WORK)
Design, supply and erect pre-engineered building steel structure of ROLE EQUIPMENT HANGER (Single Storey) complete all as specified and directed. | 1 | Each Block | 95,30,529 ₹95.3 L | 2,31,00,000 ₹2.3 Cr | 2,50,00,000 ₹2.5 Cr | 2,42,18,818 ₹2.4 Cr | 2,50,00,000 ₹2.5 Cr |
| 3.00LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS | ||||||||
| 3.01 | Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTH WORK as listed in Schedule 'A' Part-II brought forward from serial page No. 53 to 55. | 1 | Lump sum | 19,09,20,959.5 ₹19.1 Cr | 27,11,85,181.07 ₹27.1 Cr | 24,00,00,000 ₹24 Cr | 18,31,01,795 ₹18.3 Cr | 27,11,00,379 ₹27.1 Cr |
| 3.02 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 56 to 62. | 1 | Lump sum | 1,24,65,801 ₹1.2 Cr | 90,65,235 ₹90.7 L | 54,39,141.27 ₹54.4 L | 90,64,166 ₹90.6 L | 69,25,895 ₹69.3 L |
| 3.03 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-IV brought forward from serial page No. 63. | 1 | Lump sum | 15,65,180 ₹15.7 L | 17,26,952.86 ₹17.3 L | 14,27,233.77 ₹14.3 L | 20,91,624 ₹20.9 L | 16,16,411 ₹16.2 L |
| 3.04 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 64 & 65. | 1 | Lump sum | 26,02,984.5 ₹26.0 L | 28,57,336.08 ₹28.6 L | 20,00,000 ₹20 L | 42,90,079 ₹42.9 L | 27,09,974 ₹27.1 L |
Updated dates
Tender Value
₹184.0 Cr
EMD Value
₹15 L
Closing Date
5 Jan 2026, 6:00 pmClosed
Chief Engineer Jalandhar Zone Jalandhar Cantt
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
PROVN OF CERTAIN TECHNICAL INFRASTRUCTURE AT TIBRI (GURDASPUR) MIL STN (PHASE-II) (TENDER-1)
2025_MES_734394_1
81068/E8
Open Tender
Civil Works
3975 days
Jalandhar Cantt
As per NIT Documents
9 documents required · 9 mandatory
₹3,000
Garrison Engineer Gurdaspur
₹15 L
Yes
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
19 Mar 2026
9 Oct 2025
12 Jan 2026
9 Oct 2025
5 Jan 2026
15 Dec 2025
10 Oct 2025 - 4 Nov 2025
27 Oct 2025
SECURITY WALL WORKS
Supply and fix LED flat panel 560mm x 560mm x 45mm, 24 watts for surface mounting soft-light and glare free symmetrical illumination including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
AIRFIELD LIGHTING WORKS
One light point controlled by two Nos two way switches.
M&L for construction of valve pit of size 90cm x 90cm x 90cm (internal dimensions), stone/ brick construction, including all necessary excavation and earth work in any type of soil, returning, filling in disposal of surplus spoil to distance not exceeding 50m and depositing where directed, PCC in foundation of the mix (1:2:4) type D-2, stone masonry in cement mortar (1:4) rendering 12mm duck in cement mortar (1:4) internally, finished even and fair and pointing flush externally as the work proceeds in the same mortar. Mild steel angle iron 40mm x 40mm x 6mm frame MS sheet cover 3.15 mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the that as approved by the GE over a cost of red oxide primer and painting all the MS embedded in PCC with two coats of black bituminous paint complete all as specified and shown on drawing.
M&L for construction of valve pit of size 60cm x 60cm x 60cm (internal dimensions), stone/ brick construction, including all necessary excavation and earth work in any type of soil, returning, filling in disposal of surplus spoil to distance not exceeding 50m and depositing where directed, PCC in foundation of the mix (1:2:4) type D-2, stone masonry in cement mortar (1:4) rendering 12 mm duck in cement mortar (1:4) internally, finished even and fair and pointing flush externally as the work proceeds in the same mortar. Mild steel angle iron 40 x 40 x 6mm frame MS sheet cover 3.15 mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the that as approved by the GE over a cost of red oxide primer and painting all the MS embedded in PCC with two coats of black bituminous paint complete all as specified and shown on drawing.
One socket outlet 5 pin 5 Amp controlled by one No. one way switch on same board.
Supply and fix modular white cover plate 12 module with frame complete all as specified and directed.
Supply and fix LED energy efficient LED bulb B22 9 watt complete all as specified and directed.
Supply and fix reading light, aluminium base body flush mount 3 watt LED fixed on wall at suitable height complete all as specified and directed.
One socket outlet point 5 amps on the independent board.
Output AC (a) AC grid connection type : 3/N/PE (b) Rated Power at unity PF: Suitable for SPV DC cap installed at building. (c) Max AC output power : 110% of rated power (d) Max AC output Apparent power : As per Inverter rated output (e) Max AC output Current : As per Inverter rated output (f) Max AC fault current : As per Inverter rated output (g) Nominal Output Voltage : 415 V (h) Grid Output voltage range : According to SEB standard (j) Rated Grid Frequency : 50 Hz (k) Output Frequency : 50 Hz ± 3Hz (l) Power factor : > 0.9 (Lag or lead) (m) Thermal Harmonic Distortion i (THDi) : < 3% (n) MPPT Efficiency : > 99% (o) EU efficiency : 97.5% (p) No of Protected DC inputs :
(k) Plants installed in high dust geographies like Punjab must have the solar modules tested with relevant dust standards (Applicable standard would be IEC 60068-2-68). (l) Both PV cells and SPV modules shall be make in India. (m) Each structure should have angle of inclination as per the site conditions to generate maximum power. (n) Any damage to the existing roof treatment of any type due to the Installation of Solar Power System shall be Re-done/made good as per existing treatment. Cost of the same shall be deemed to be included in the unit rate quoted. Nothing extra shall be admissible on this account.
Output AC (a) AC grid connection type : 3/N/PE (b) Rated Power at unity PF: Suitable for SPV DC cap installed at building. (c) Max AC output power : 110% of rated power (d) Max AC output Apparent power : As per Inverter rated output (e) Max AC output Current : As per Inverter rated output (f) Max AC fault current : As per Inverter rated output (g) Nominal Output Voltage : 415 V (h) Grid Output voltage range : According to SEB standard (j) Rated Grid Frequency : 50 Hz (k) Output Frequency : 50 Hz ± 3Hz (l) Power factor : > 0.9 (Lag or lead) (m) Thermal Harmonic Distortion i (THDi) : < 3% (n) MPPT Efficiency : > 99% (o) EU efficiency : 97.5% (p) No of Protected DC inputs :
Supply and fix VTPN DB 4 way, double door, 415 V IP 43, suitable size and length of CRCA sheet steel, dust protection, duly powder painted inclusive of factory fitted copper bus bar of suitable size, 01 No MCC
B as incomer and 12 Nos of SP as outgoing with common neutral link, earth bar, Din bar for mounting of MCB's and blanking plate including fixing to wall complete all as specified and directed.
Supply and fix VTPN DB 6 way, double door, 415 V IP 43, suitable size and length of CRCA sheet steel, dust protection, duly powder painted inclusive of factory fitted copper bus bar of suitable size, 01 No MCCB as a incomer and 24 Nos of SP as outgoing with common neutral link, earth bar, Din bar for mounting of MCB's and blanking plate including fixing to wall complete all as specified and directed.
All as Ser item 4.01 here in before but with 2.5 sqmm wire and earth wire of 2.5 sqmm for 3 Pin 15 Amp modular type socket outlet.
Supply and fix LED tube light fitting in extruded aluminium housing for all purpose surface and wall mounted with single side connection polycarbonate LED batten with polycarbonate housing and integrated electronic driver of capacity 20 W, four feet and connection with PVC insulated twin core 23/ 0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed.
Square Metre
Supply and fix wall/ ceiling mounting LED 9/ 10 Watt tube light fitting in extruded aluminium housing and integrated electronic driver complete with all accessories 1 x 9/ 10 watt LED, two feet with CCT of 6000k suitable for domestic application, 240 Volts, 50 Hz and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection complete all as specified and directed.
Supply and fix LED tube light fitting for surface and wall mounted with single side connection polycarbonate LED batten in extruded aluminium housing and integrated electronic driver of capacity 36/40 W, four feet and connection with PVC insulated twin core 23/ 0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed.
Supply and fix modular dummy plate complete all as specified and directed.
Supply and fix bldg street fitting made up of pressure die cast aluminium housing with high efficiency LED's as lighting source and lens embedded PC cover having TOP opening, separate driver compartment with IP 66 protection and impact resistance of IK07, CCT 5700 K of wattage 25 watt including connection with 3 core PVC insulated overall sheathed flexible cable with multi stranded copper conductor of size not less than 1.0 sqmm from celling rose to fitting terminal all as specified and as directed.
Supply and fix aviation obstacle light die-cast aluminium housing with red polycarbonate dome for better illumination with integral driver, IP-65 protection of capacity 10 watt including connection with PVC insulated overall sheathed flexible cable with multi stranded copper conductor of suitable size complete all as specified and as directed.
Output AC (a) AC grid connection type : 3/N/PE (b) Rated Power at unity PF: Suitable for SPV DC cap installed at building. (c) Max AC output power : 110% of rated power (d) Max AC output Apparent power : As per Inverter rated output (e) Max AC output Current : As per Inverter rated output (f) Max AC fault current : As per Inverter rated output (g) Nominal Output Voltage : 415 V (h) Grid Output voltage range : According to SEB standard (j) Rated Grid Frequency : 50 Hz (k) Output Frequency : 50 Hz ± 3Hz (l) Power factor : > 0.9 (Lag or lead) (m) Thermal Harmonic Distortion i (THDi) : < 3% (n) MPPT Efficiency : > 99% (o) EU efficiency : 97.5% (p) No of Protected DC inputs :
Supply and fix energy saving new generation 10 watt LED built up, 6000k bulk head luminaire with opal diffuser light fitting complete with all accessories and connection complete all as specified and directed.
Supply & fix on site conventional LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, Vent shaft, connection etc. complete for 20 users capacity complete all as specified and directed.
Supply & fix stainless steel control valve 15mm bore as specified and directed.
Supply and fix stainless steel pipe (AISL 304) 20mm bore schedule 10mm wall thickness 2.11mm laid in floor or trench with all fitting and accessories i.e. bend, socket, reducer, tee etc. as required at site complete all as specified and directed.
M&L for drilling 300mm bore hole by hydraulic rig/ reverse rotary/ callex rig in any type of strata including hard and soft rock complete all as specified and directed.
S&F 150mm dia UPVC slotted pipe of slot size 1.58mm with 5mm thick pipe of approved make complete all as specified and directed.
S&F bail plug 160mm dia and housing clamp with nuts and bolts complete all as specified and directed.
S&F plug cap 160mm dia and housing clamp with nuts and bolts complete all as specified and directed.
Supply and laid in layers 12.5 mm graded coarse aggregate as in rainwater harvesting recharge pit, complete all as specified.
Supply and laid in layers 3 to 5mm size Pea Gravel as in rainwater harvesting recharge pit, complete all as specified.
Supply and fix LED tube light fitting suspended mounted linear down light luminaire with enclosure made of heavy gauge extruded aluminium housing with PC diffuser with IP 20 including jointing accessories and suspension kits of capacity 20 W and connection with PVC insulated twin core 23/ 0.0076 twisted copper cable from ceiling rose to LED light fitting complete all as specified and directed.
S&F junction box poly carbonate with glass fibre reinforced, environment friendly, recyclable, UV resistant, halogen and silicon free anti acid and anti-corrosive IP65/ 66 in accordance with IE rule internally embedded gasket, junction box including 3 phase 415 volt aluminium bus bar and one no MCB SP 6A, 10 KA to control the street light including necessary clamps, nuts bolts to fix the junction box with poles all specified and directed.
FORWARD SPEED LANDING AREA WORKS
Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65, outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/ outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400mm below the ground level constructed with bricks (sub class 'B') work duly plastered in CM (1:3) and PCC copping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-
Supply and fix modular metal box flush type 12 module made out of GI sheet not less than 1.2mm with earthing terminal complete all as specified and directed.
Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65, outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/ outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400mm below the ground level constructed with bricks (sub class 'B') work duly plastered in CM (1:3) and PCC copping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-
Supply and fix bracket made out of 32mm bore light grade GI pipe 1.50m long bend to shape including 2 No. MS clamps made out of flat iron of size 32mm x 4mm thick compatible with bldg security light mentioned in item ser No. 4.24 with nuts & bolts, washers fixed to wall/ pole at specified height complete all as specified and directed.
Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65, outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/ outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400mm below the ground level constructed with bricks (sub class 'B') work duly plastered in CM (1:3) and PCC copping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-
Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65, outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/ outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400mm below the ground level constructed with bricks (sub class 'B') work duly plastered in CM (1:3) and PCC copping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-
Supply and fixing kitchen chimney dry heat, auto clean technology, stainless with air outlet 150mm, steel finish front matte black glass panel with digital display. touch control panel with 9 speed gesture motion, heavy duty baffle filters, minimum air flow 1480 m³/ hour, energy saving LED light of suitable wattage, copper winding BLDC motor, 59dba max noise level and voltage 220-240 V, 50 Hz including making hole in the wall and making good the disturbed surface of wall including all accessories complete all as specified and directed. Make :- KAFF Model No. SKU OPECDHC90BLK(IS) or eqvt in Hindware/ Faber.
Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65, outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/ outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400mm below the ground level constructed with bricks (sub class 'B') work duly plastered in CM (1:3) and PCC copping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-
Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65, outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/ outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400mm below the ground level constructed with bricks (sub class 'B') work duly plastered in CM (1:3) and PCC copping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-
Each jOB
Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65, outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/ outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400mm below the ground level constructed with bricks (sub class 'B') work duly plastered in CM (1:3) and PCC copping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65,outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400 mm below the ground level constructed with bricks (sub class 'B') work duly plastered in CM (1:3) and PCC copping (1:2:4) not less than 50 mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-
Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65, outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/ outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400mm below the ground level constructed with bricks (sub class 'B') work duly plastered in CM (1:3) and PCC copping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-
Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65, outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/ outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400mm below the ground level constructed with bricks (sub class 'B') work duly plastered in CM (1:3) and PCC copping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-
Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65, outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/ outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400mm below the ground level constructed with bricks (sub class 'B') work duly plastered in CM (1:3) and PCC copping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-
Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65, outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/ outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400mm below the ground level constructed with bricks (sub class 'B') work duly plastered in CM (1:3) and PCC copping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-
Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65, outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/ outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400mm below the ground level constructed with bricks (sub class 'B') work duly plastered in CM (1:3) and PCC copping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:-
Supply and fixing heavy duty, turbo force exhaust fan 300mm sweep, 1400 RPM, 1710 m³/ hour air delivery with corrosion resistant body, minimal noise operation and maintenance free design, totally enclosed, high efficient heavy duty motor with pressure die cast aluminium rotor mounted on two ball bearings, aerodynamically contoured blades, rigid frame with rubber mountings for silent operation conforming to IS 2313-1967 single phase, IP 55 including cutting circular hole in the wall to suit the size of the frame which shall be fixed by means of rag bolts embedded in the wall. The hole shall be neatly plastered to the original finish of the wall and connected with and including three core 1.5 sqmm, PVC insulated but unsheathed FRLS cable with multi-stranded copper conductors from ceiling rose to fan complete all as specified and directed. Make:- Modal No Turbo force single phase FHEHDSPDB120 of Havells or equivalent in Bajaj and CG.
(F) Power Conditioning Unit/ Grid Tied Inverter: Design, supply, installation, testing and commissioning 3 phase PCU/ string inverters - 01 Nos(min) or higher qty as per site/ design approved of suitable capacity as given AC (nominal power), suitable to convert DC power of installed Solar PV module/ array to AC for planned building for further feeding to grid confirming to IEC:61683/ IS 61683, IS 16221 (Part 2), IS 16169 and IEC 60068-2 (1,2,14 & 30)/IEC : 62093 (as applicable)/ equivalent BIS standard for efficiency, for safety and for reliability. The input DC & output AC technical specification of Inverter are as under :-. Input (DC) (a) Max input Voltage : 1100 V (b) Rated Input Voltage : 600 V c) Start-up input voltage : 200 V d) Operating input DC voltage range : 300 - 950 V (e) No of independent MPPT : Must be suitable to accommodate installed DC SPV array & their cap. Min 2 to 10 (as per approved design based on No of array strings) (f) MPPT operating voltage range : 180 - 960 V (g) Max input DC Current : As per approved array string design (h) Maximum input short circuit current : As technically reqd & Suitable as per approved array string design (j) No of Protected DC inputs/ strings : 6 to 20 (as per approved design based on No of array strings)
Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type copper wound, designed for input voltage between 170 volts to 250 volts and output voltage stabilized at 230 volts with accuracy of + 2.5% and of capacity 5 KVA with low and high voltage cut off for 2 to 3 minute time delay relay complete all as specified and directed.
Supply & fix bracket made out of 32mm bore light grade GI pipe 1.5 mtr long bend to shape with suitable cut at bend point & welded as per standard engineering practice provided with two No. MS clamps made out of 32mm x 6mm thick flat iron fixed with nuts, bolts and washers of suitable size complete all as specified and directed.
Supply and fixing weather proof flat three core cable aluminium conductor of size 2.5 sqmm all as specified and directed
S&F aviation obstacle light die-cast aluminium housing with red polycarbonate dome for better illumination with integral driver, IP-65 protection of capacity 10 watt complete all as specified and directed.
M&L for construction of platform of suitable size (Minimum size- 300cm x 300cm x 120cm) using brick masonry of sub class 'B' (old size) bricks for mounting of outdoor type transformer of capacity 200 KVA to 400 KVA including 1 meter working space all around complete all as specified and directed.
M&L for drilling hole under the road, pavement, hard standing etc. by trenchless technology using ultra sounding technique and necessary machine including supply and laying 150mm dia HDPE pipe suitable for 0.4 Mpa working pressure complete all as specified and directed.
Fan point/ exhaust fan point/ one light point/ bell/ buzzer controlled by one switch/ bell push.
Supply and fix 150 watt ADV series high bay LED light fitting, energy saving, environment friendly and robust high bay LED with PDC housing suitable for mounting on ceiling (surface/ suspended) with system efficacy 150 Lm/ watt including jointing accessories and suspension kits of capacity 150 W and connection with suitable size PVC insulated copper cable from ceiling rose to LED high bay light fitting complete all as specified and directed. (For WSI FLT Hanger, Roll Eqpt Hanger & Blast Pen) Make:- Cat No SAUCERGENXADBHBP150WLED857PWBBORL of Havells or eqvt in HPL/ Bajaj/ CG.
(D) ACCOUSTIC ENCLOSURE: Provision of an integral type approved/ certified acoustic enclosure. It shall be made of 16 SWG or manufacturer's standard norms out of CRCA sheet with powder coated finish on outside and provided with non-igniting fire retardant foam as acoustic material of suitable thickness and perforated sheet of stainless steel as per manufacturer design. The doors and glass window shall be as per manufacturer's design. The base frame shall be of ISMC. It shall also include the following:- (a) Silencer: Suitable exhaust Residential grade silencer to reduce the noise level. (b) Internal wiring with PVC copper cable FRLS in conduit and for light and fan point lamp fittings including lamp. (c) Fuel tank: Sub Base Fuel tank of 14 SWG MS sheet of capacity considered as per OEM duly powder coated. (d) Two No of 12V 120 Ah maintenance free batteries as recommended by manufacturer. (E) Standard digital control panel suitable to accommodate inside acoustic enclosure all as specified. (F) Base rail: Base rail with integral fuel tank is provided. (G) AMF Power Control Panel:- Supply fabricating, fixing, commissioning & testing Powder Coated AMF control panel suitable for 58.5 KVA DG Set manufactured with 3.00mm thick CRCA sheet with angle iron frame of 50mm x 50mm x 6mm and shall be outdoor cubical type LT panel 415 Volts 3 Phase 4 wire system 50 Hz, floor mounted consisting of following accessories:- (a) Master controller of suitable size- 01 No. (b) MCCB four pole of suitable size- 03 No. (c) Contactor and relays of suitable capacity- 02 No. (d) Digital Volt meter of suitable size- 02 No. (e) Digital Ampere meter of suitable size- 02 No. (f) Digital Frequency meter- 01 aux supply 230 volts AC. (g) Push Button start, stop reset-01 No set, three
Supply, installation, testing and commissioning of 45 Watts elevated Omni-directional LED runway edge light, 6.6Amp/ 6.6 Amp of colour white/ white alongwith mounting assembly (breakable coupling & other components), connecting leads, gasket fasteners suitably protected against corrosion by nickel plating, base plate with 06 No. M-10 stainless steel bolts including painting all as per OEM recommendation and specifications of ICAO Annx 14 complete all as specified and as directed.
Supply, installation, testing and commissioning of 65 Watt elevated omni-directional LED flare path lights, 6.6 Amp/ 6.6 Amp, white colour on both side of helipad along the runway alongwith mounting assembly (breakable coupling & other components), connecting leads, gasket fasteners suitably protected against corrosion by nickel plating, base plate with 06 No. M-10 stainless steel bolts including painting all as per OEM recommendation and specifications of ICAO Annx 14 complete all as specified and as directed.
Supply, installation, testing and commissioning of 65 Watts elevated Bi-directional LED runway threshold cum end lights, 6.6 Amp/ 6.6 Amp of colour Red & Green alongwith mounting assembly (breakable coupling & other components), connecting leads, gasket fasteners suitably protected against corrosion by nickel plating, base plate with 06 No. M-10 stainless steel bolts including painting all as per OEM recommendation and specifications of ICAO Annx 14 complete all as specified and as directed.
Supply, installation, testing and commissioning of 100 watts elevated Uni-directional LED approach funnel light, 6.6Amp/ 6.6 Amp of white colour/ white alongwith mounting assembly (breakable coupling & other components), connecting leads, gasket fasteners suitably protected against corrosion by nickel plating , base plate with 06 No. M-10 stainless steel bolts including painting all as per OEM recommendation and specifications of ICAO Annx 14 complete all as specified and as directed.
Supply, installation, testing and commissioning of 65 Watt LED elevated Yellow colour Helipad lights, 6.6 Amp/ 6.6 Amp complete alongwith mounting assembly (breakable coupling & other components), connecting leads, gasket fasteners suitably protected against corrosion by nickel plating, base plate with 06 No. M-10 stainless steel bolts including painting all as per OEM recommendation and specifications of ICAO Annx 14 complete all as specified and as directed.
ROOF TOP SOLAR SYSTEM
Supply, Installation, testing and commissioning of 45 Watt, 6.6A/ 6.6A, rating 5KV, 50 Hz series isolating transformers for runway edge lights encapsulated in polyester resin, finally moulded in neoprene type rubber and with primary and secondary connections, necessary connecting kit for connection of runway lights confirming to ICAO Annx-14 specifications complete all as specified and as directed.
Supply, Installation, testing and commissioning of 65 Watt, 6.6A/ 6.6A, rating 5KV, 50 Hz series isolating transformers for flare path, threshold cum end & helipad light encapsulated in polyester resin, finally moulded in neoprene type rubber and with primary and secondary connections, necessary connecting kit for connection of runway lights confirming to ICAO Annx 14 spec
ifications complete all as specified and as directed.
Supply, installation, testing and commissioning of 100 Watt, 6.6A/ 6.6A, rating 5KV, 50 Hz series isolating transformers for approach light encapsulated in polyester resin, finally moulded in neoprene type rubber and with primary and secondary connections, necessary connecting kit for connection of runway lights confirming to ICAO Annx-14 specifications complete all as specified and as directed.
S&F 160mm dia UPVC pipe of first quality of approved make complete all as specified and directed.
Each Job
Supply & fix of 6 Sqmm, 5 KV grade plug and receptacle of type 1 class ‘B’ connector and suitable field attachment with 5 KV grade PVC insulated PVC sheathed single core 6 Sqmm size copper conductor cable confirming to the specified specification etc. complete all as specified and as directed.
Supply & laying 63mm/ 50mm dia DWC (Double Wall Corrugated) HDPE pipe in trench for cable protection with necessary connecting material viz. snap fit coupler etc. for aviation cable laying complete all as specified and directed. (Excavation and earthwork will be measured and paid for separately).
Supply only standard maintenance tools for AFLS incorporating HV IR Tester (Make: Fluke or equivalent), RMS Tong tester (Make: Fluke or equivalent) and insulation sleeves blower gun complete all as specified and directed. Make: Bosch or equivalent make as approved by GE.
Supply, installation, testing and commissioning of elevated Omni directional LED Taxi Way Edge lights of 10 Watts, 6.6 Amp/ 6.6 Amp of colour blue alongwith mounting assembly (breakable coupling & other components), connecting leads, gasket fasteners suitably protected against corrosion by nickel plating, base plate with 06 No M-10 stainless steel bolts including painting all as per OEM recommendations and specifications of ICAO Annx-14 complete all as specified and directed
Supply, installation, testing and commissioning of LED elevated blue dispersal light of max 65 watts, 6.6 Amp/ 6.6 Amp alongwith mounting assembly (breakable coupling & other components), connecting leads , gasket fasteners suitably protected against corrosion by nickel plating , base plate with 06 No. M-10 stainless steel bolts including painting all as per OEM recommendation and specifications of ICAO Annx-14 complete all as specified and directed.
Supply, installation, testing and commissioning of 10 watt, 6.6A/ 6.6A, rating 5KV, 50 Hz series isolating transformers for taxiway edge lights (10 W) encapsulated in polyester resin, finally moulded in neoprene type rubber and with primary and secondary connections, necessary connecting kit for connection of runway lights confirming to ICAO Annx-14 specifications complete all as specified and directed.
Supply, installation, testing and commissioning of 65 watt, 6.6A/ 6.6A, rating 5KV, 50 Hz series isolating transformers for dispersal light encapsulated in polyester resin, finally moulded in neoprene type rubber and with primary and secondary connections, necessary connecting kit for connection of runway lights confirming to ICAO Annx-14 specifications complete all as specified and as directed.
Supply and laying 6 SWG GI wire all as specified and directed.
M&L for chemical earthing including steel electrode, high tensile, low carbon molecularly bonded with copper on outer surface as per UL requirement of 3 mtr long, 17mm dia with copper bonded thickness of 250 microns (Minimum), copper coated low carbon bonded bus bar of size 300mm x 25mm x 6mm with suitable hole and exothermically welded to main earth electrode for taking the connections to main earth bus bar and backfilling with conductive, non-semi water soluble and earth pit cover chamber of poly plastic, heavy duty, weather proof, environmental free with cover size about top dia 254mm, bottom dia 330mm and height 260mm including copper earth strip 50mm x 6mm complete all as specified and directed.
Supply & fixing online UPS of rating 20 KVA with batteries conforming to JISC including batteries for 30 min backup 3 phase 300 to 450 Volt and output 415 Volt ± 1 % of capacity 20 KVA including necessary input and output wiring complete all as specified and directed.
Supply, laying, commissioning and testing of single mode optical fibre as per OEM and site requirement including suitable size pipe protection with necessary clamping for protection of cable along the wall/ floor complete all as specified and directed.
Supply & fix automatic air release valve 50mm dia suitable for domestic water with 50mm gun metal stop valve complete all as specified and directed.
Supply and fix dual plates CI wafer type check valve, 80mm bore tested to pressure of 15Kg/ Sqcm complete all as specified and directed.
Supply, installation, testing and commissioning of electric terrace fire control panel metal clad cubical type suitable for 425 V AC three phase 4 wire 50 Hz supply system. The panel should be suitable for automatic operation for the fire pump 440 volt, 3 phase, 50 Hz, 30m head having 450 LPM discharge. The panel shall be compartmentalized and provided with relays, contractor, starters, aluminium bus bar, designation labels as per requirement, continuous earth bar, panel separators, protective screens, cable clamping supports system, panel lamps, top/ bottom cable gland plate for incoming and outgoing cable entries complete all as specified and directed.
Supply and fix pipe supports for pipe of any type and size including hangers/ fasteners/ elbows/ supports/ tees etc. complete all as specified and directed.
Supply and fixing repeater panel model No. CF-FIRELINE AR Make- Agni/ Apollo all as specified and directed.
Supply & fix laser etched LED light double sided exit signage on ceiling/ wall mounted with logo & exit arrow on transparent acrylic sheet of 303mmx 140mm and powder coated top M.S Box with 4 hours backup complete all as specified and directed.
Supply & fix 2 sqmm 2 core stranded copper conductor armoured cable XLPE insulated with GI steel wire round/ strip armoured PVC outer sheathed complete all as specified and directed.
Supply & fix 1.5 sqmm 4 core stranded copper conductor armoured cable XLPE insulated with GI steel wire round/ strip armoured PVC outer sheathed complete all as specified and directed.
Supply, installation and testing of rechargeable maintenance free 24 volts, sealed lead acid batteries, sufficient for 24 hours normal working & then capable of operating the system for 24 hours during emergency conditions as required having volts and backup of life not less than 3 years fixed in and including suitable MS box complete all as specified and directed.
Supply & fix cast iron transformer housing boxes 330mm dia and 450mm height having side plate all around and top plate with hole on top plate complete including necessary excavation and earth work and PCC work as per OEM recommendations and as per ICAO Specifications Annx-14 complete all as specified and directed.
Supply and fix dual zone module Model No. CF-CHQ-DZM of make Cease Fire or equivalent as approved by GE complete all as specified and directed.
Supply and fix water-cum-foam monitor on fixed fire hydrant line SS tank mobile foam unit capacity 200 litre alongwith inline inductor, nozzle, water cum foam monitor with swivel action, 1750 LPM 63mm dia for flow and 3% concentration foam type complete all as specified and directed.
and directed.
Supplying, fixing, testing and commissioning 150mm dia installation control valve with turbine type automatic alarm gong connected with control valve, drain & test valve and all necessary components as per manufacturer's specifications complete all as specified and directed.
SUMMER APPLIANCES AND COOLING APPLIANCES WORKS
Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type copper wound, designed for input voltage between 170 volts to 250 volts and output voltage stabilized at 230 volt with accuracy of + 2.5% and of capacity 4 KVA with low and high voltage cut off for 2 to 3 minute time delay relay complete all as specified and directed.
Supply & fix refrigerator, electric driven (single phase) and capacity 195 ltr with BEE 5 star rating complete all as specified and directed.
M&L for planting carpet grass including surface excavation n. exc. 30cm deep and averaging 15cm deep and getting out in soft/ loose soil, separating the roots/ grass and good earth by sieving with suitable sieve size, stacking good earth and mixing manure of 5:1 ratio including supply of manure, screened through sieve of 1.5 designation 4.75mm and spreading the mixture, applying suitable pesticide, watering to the depth of 15cm including removal of roots/ grass out of MoD land complete all as specified and directed.
M&L for DI fittings such as bends, tapers, tail pieces, Tee pieces, caps and plug set including rubber ring push on joints suitable for 100mm bore DI pipes complete as specified and directed.
Kilogram
M&L for taping existing DI pipe 100mm to 80mm dia including cutting, jointing and inserting tee piece and other all accessories including necessary joints complete all as specified and directed.
M&L for taping existing DI pipe 100mm to 50mm dia including cutting, jointing and inserting tee piece and other all accessories including necessary joints complete all as specified and directed.
M&L for taping existing DI pipe 100mm to 40mm dia including cutting, jointing and inserting tee piece and other all accessories including necessary joints complete all as specified and directed.
M&L for taping existing 150mm bore DI rising main to DI 100mm for fire fighting UG sump including cutting, jointing and inserting tee and providing one No. 100mm dia sluice valve complete with all accessories, flanges etc. complete all as specified and directed.
Supply & fix air compressor alongwith intake filter, flywheel mounted with 220 litre air tank fitted with pressure switch, pressure gauge, safety valve, non-return valve, drain valve, delivery valve, V- belt with belt guard including motor and starter of capacity 5 HP with max pressure 12 kg/ cm², 3 phase including necessary foundation as per manufacturer’s instructions complete all as specified and directed.
Supply & fix stainless steel nozzle for 15mm bore pipe as specified and directed.
Supply and fix 120 watt LED flood light made up of pressure die cast aluminium housing with high efficiency LED's as a light source suitable for highlighting architectural features with IP 66 protection and impact resistance of IK07, CCT 5700 K of wattage 120 watt including connection with 3 core PVC insulated overall sheathed flexible cable with multi stranded copper conductor of suitable size from celling rose to fitting terminal complete all as specified and as directed. (For Elevated watch Tower & WSI FLT Hanger/ Roll Eqpt Hanger/ Blast Pen outside Area)
Supply and fixing sub main wiring with 2 runs of 1.5 sqmm single core, multi-stranded PVC insulated, FRLS unsheathed cable 1100 volts grade with copper conductor drawn through and including non-metallic PVC conduit, medium grade of suitable size with necessary conduit fittings and accessories on surface of wall/ ceiling of hanger including 1 run of 1.5 Sqmm multi-stranded PVC insulated FRLS copper conductor cable as earth continuity conductor and conn
ecting to common earth dolly complete all as specified and directed. (For High bay Light fittings & Flood Light LED fittings in WSI FLT Hanger, Roll Eqpt Hanger) Notes: (i)Two runs of 1.5 sqmm copper cable and one run of 1.5 sqmm copper cable alongwith non-metallic PVC conduit/ conduit accessories will be measured as one unit length (ii) The setup allows for control two Nos high bay light fitting/ flood light fittings with a single switch conveniently.
Supply only pedestal air circulator fan 450mm sweep, 1440 RPM of aerodynamically designed blades for higher air delivery and minimal noise levels with double 'Z', shielded ball bearing, oscillation upto 90º total flexibility, sturdy brazed wire guards with power coating ensures corrosion resistance conforming to IS 2997-1964 complete all as specified and directed. (for Repair bays)
Supply and fix three phase 8 KW automatic street light control switch using infrared sensor based NATURE SWITCH for automatic switching of street lights. Nature switch operation should be based on Natural Light Lux level. Switching off luminance level should be of minimum 30 LUX and switching on luminance should be greater than or equal to 10 LUX. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs. The circuit shall have a provision for manual over ride operation. The sensor along with suitable power contactors and incoming outgoing MCB’s should be enclosed in pole/ wall mountable enclosures made of rust proof, electric shock proof, termite proof and FR grade with Hensel Enclosures, conforming to IP 66 complete all as directed. Make of switch: Kaatiya Energy System/ Havells/ Healer Enterprises. Make of Contactor: Legrand/ L&T/ Schneider. Make of MCBs: Legrand/ L&T/ Schneider. Make of SMC enclosure and circuit sheet: Hensel/ Sintex.
Supply, installation, commissioning and testing of eco-friendly Diesel Engine driven generating set silent type confirming to CPCB IV condition/ norms, 15 KVA (12 KW) rating as per BS-5514, 03 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM, 415 volts (AC 3 phase,4 wire system of supply) 50 Hz at 0.8 power factor directly coupled alternator & engine, water cooled, mounted on common base plate of rigid fabricated mild steel frame platform with floor mounted fuel tank of suitable capacity(minimum 12 hrs capacity of consumption) & including all excavation PCC foundation, anti-vibration pads/ dampers including standard control panel other accessories as per manufacturer's design. The Gen set should be fitted with integrated acoustic enclosure manufactured by the OEM of the Generating set .The Generating Set and acoustic enclosure shall confirm to emission norms and noise level. The acoustic enclosure shall be type tested and certificate obtained for the type approved from approved agencies listed in Govt. Notification. Specifications of DG set shall be as specified and comprising of the following: - (A) ENGINE (Prime mover): Diesel engine vertical type of adequate capacity for 15 KVA (12 KW), 03 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM under NTP conditions of BS: 5514, turbo charged water cooled, compression ratio 17.3:1, 02 No. x 12 volts 90 Ah electric battery start, complete with fly wheel and all standard fittings/ fixtures as per manufacturer instructions including suitable engine control panel/dash Board with electronic tachometer. Lubrication oil temperature & pressure gauges water temp gauge and frequency meter (digital type) including safety automatic shutdown in case of fault such as high water temperature low oil pressure, over speed etc. including self-starter, alternator, cogged, V-belt, fuel tank with first fill of lubricating oil and coolant (as applicable) etc. complete all as specified. (B) ALTERNATOR: Alternator AC, 3 phase 415 volts 4 wire rated line current for output 15 KVA, PF 0.8, 1500 RPM confirming to BS 5000 directly coupled with above engine. The Alternator shall be brushless type, screen protected, revolving field, self-exited, self-regulated through an AVR. The alternator has the following features :- (a) + 0.5% voltage regulation (max) in static conditions. (b) IP-23 protection with insulation class H (c) Permissible overload of 10% for one hour in 12 hours of operation. (d) Anti-vibration pads for mounting engine and alternator assembly on the base frame/ plate or as recommended/ provided by the manufacturer.
Supply, installation, commissioning and testing of eco-friendly Diesel Engine driven generating set silent type confirming to CPCB IV condition/ norms, 160 KVA (128 KW) rating as per BS-5514, 06 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM, 415 volts (AC 3 phase,4 wire system of supply) 50 Hz at 0.8 power factor directly coupled alternator & engine, water cooled, mounted on common base plate of rigid fabricated mild steel frame platform with floor mounted fuel tank of suitable capacity(minimum 12 hrs capacity of consumption) & including all excavation PCC foundation, anti-vibration pads/ dampers including standard control panel other accessories as per manufacturer's design. The Gen set should be fitted with integrated acoustic enclosure manufactured by the OEM of the Generating set .The Generating Set and acoustic enclosure shall confirm to emission norms and noise level. The acoustic enclosure shall be type tested and certificate obtained for the type approved from approved agencies listed in Govt. Notification. Specifications of DG set shall be as specified and comprising of the following: - (A) ENGINE (Prime mover): Diesel engine vertical type of adequate capacity for 160 KVA (128 KW), 06 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM under NTP conditions of BS: 5514, turbo charged water cooled, compression ratio 17.3:1, 02 No. x 12 volts 180 Ah electric battery start, complete with fly wheel and all standard fittings/ fixtures as per manufacturer instructions including suitable engine control panel/dash Board with electronic tachometer. Lubrication oil temperature & pressure gauges water temp gauge and frequency meter (digital type) including safety automatic shutdown in case of fault such as high water temperature low oil pressure, over speed etc. including self-starter, alternator, cogged, V-belt, fuel tank with first fill of lubricating oil and coolant (as applicable) etc. complete all as specified. (B) ALTERNATOR: Alternator AC, 3 phase 415 volts 4 wire rated line current for output 160 KVA, PF 0.8 1500 RPM confirming to BS 5000 directly coupled with above engine. The Alternator shall be brushless type, screen protected, revolving field, self-exited, self-regulated through an AVR. The alternator has the following features :- (a) + 0.5% voltage regulation (max) in static conditions. (b) IP-23 protection with insulation class H (c) Permissible overload of 10% for one hour in 12 hours of operation. (d) Anti-vibration pads for mounting engine and alternator assembly on the base frame/ plate or as recommended/ provided by the manufacturer. (C) Base frame made out of structural steel as per manufacturer's recommended design/ specifications.
Supply, installation, commissioning and testing of eco-friendly Diesel Engine driven generating set silent type confirming to CPCB IV condition/ norms, 25 KVA (20 KW) rating as per BS-5514, 03 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM, 415 volts (AC 3 phase,4 wire system of supply) 50 Hz at 0.8 power factor directly coupled alternator & engine, water cooled, mounted on common base plate of rigid fabricated mild steel frame platform with floor mounted fuel tank of suitable capacity(minimum 12 hrs capacity of consumption) & including all excavation PCC foundation, anti-vibration pads/ dampers including standard control panel other accessories as per manufacturer's design. The Gen set should be fitted with integrated acoustic enclosure manufactured by the OEM of the Generating set .The Generating Set and acoustic enclosure shall confirm to emission norms and noise level. The acoustic enclosure shall be type tested and certificate obtained for the type approved from approved agencies listed in Govt. Notification. Specifications of DG set shall be as specified and comprising of the following: - (A) ENGINE (Prime mover): Diesel engine vertical type of adequate capacity for 25 KVA (20 KW), 03 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM under NTP conditions of BS: 5514, turbo charged water cooled, compression ratio 17.3:1, 02 No. x 12 volts 120 Ah electric battery start, complete with fly wheel and all standard fittings/ fixtures as per manufacturer instructions including suitable engine control panel/dash Board with electronic tachometer. Lubrication oil temperature & pressure gauges water temp gauge and frequency meter (digital type) including safety automatic shutdown in case of fault such as high water temperature low oil pressure, over speed etc. including self-starter, alternator, cogged, V-belt, fuel tank with first fill of lubricating oil and coolant (as applicable) etc. complete all as specified. (B) ALTERNATOR: Alternator AC, 3 phase 415 volts 4 wire rated line current for output 25 KVA, PF 0.8, 1500 RPM confirming to BS 5000 directly coupled with above engine. The Alternator shall be brushless type, screen protected, revolving field, self-exited, self-regulated through an AVR. The alternator has the following features :- (a) + 0.5% voltage regulation (max) in static conditions. (b) IP-23 protection with insulation class H (c) Permissible overload of 10% for one hour in 12 hours of operation. (d) Anti-vibration pads for mounting engine and alternator assembly on the base frame/ plate or as recommended/ provided by the manufacturer. (C) Base frame made out of structural steel as per manufacturer's recommended design/ specifications.
Supply, installation, commissioning and testing of eco-friendly Diesel Engine driven generating set silent type confirming to CPCB IV condition/ norms, 58.5 KVA (47 KW) rating as per BS-5514, 04 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM, 415 volts (AC 3 phase,4 wire system of supply) 50 Hz at 0.8 power factor directly coupled alternator & engine, water cooled, mounted on common base plate of rigid fabricated mild steel frame platform with floor mounted fuel tank of suitable capacity(minimum 12 hrs capacity of consumption) & including all excavation PCC foundation, anti-vibration pads/ dampers including standard control panel other accessories as per manufacturer's design. The Gen set should be fitted with integrated acoustic enclosure manufactured by the OEM of the Generating set .The Generating Set and acoustic enclosure shall confirm to emission norms and noise level. The acoustic enclosure shall be type tested and certificate obtained for the type approved from approved agencies listed in Govt. Notification. Specifications of DG set shall be as specified and comprising of the following: - (A) E
NGINE (Prime mover): Diesel engine vertical type of adequate capacity for 58.5 KVA (47 KW), 04 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM under NTP conditions of BS: 5514, turbo charged water cooled, compression ratio 17.3:1, 02 No. x 12 volts 120 Ah electric battery start, complete with fly wheel and all standard fittings/ fixtures as per manufacturer instructions including suitable engine control panel/dash Board with electronic tachometer. Lubrication oil temperature & pressure gauges water temp gauge and frequency meter (digital type) including safety automatic shutdown in case of fault such as high water temperature low oil pressure, over speed etc. including self-starter, alternator, cogged, V-belt, fuel tank with first fill of lubricating oil and coolant (as applicable) etc. complete all as specified. (B) ALTERNATOR: Alternator AC, 3 phase 415 volts 4 wire rated line current for output 58.5 KVA, PF 0.8, 1500 RPM confirming to BS 5000 directly coupled with above engine. The Alternator shall be brushless type, screen protected, revolving field, self-exited, self-regulated through an AVR. The alternator has the following features :- (a) + 0.5% voltage regulation (max) in static conditions. (b) IP-23 protection with insulation class H (c) Permissible overload of 10% for one hour in 12 hours of operation. (d) Anti-vibration pads for mounting engine and alternator assembly on the base frame/ plate or as recommended/ provided by the manufacturer. (C) Base frame made out of structural steel as per manufacturer's recommended design/ specifications.
(e) Each module shall have RFID tag encapsulated/ laminated inside glass. Following information must be mentioned in RFID:- (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell (iii) Month and year of Manufacturing (separately for solar cell and module) (iv) Country of Origin for solar cell and module (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no and model no of module (viii) IV curve of module (f) The temperature coefficient (Power) for the PV module shall not be more than - 0.40% per degree Celsius. (g) Every module must have bypass diode of suitable capacity. (h) PV module must confirm to latest edition of IEC 61215/ IS 14286, IEC 61853 Part I or IS 16170 Part-I. In addition the modules must confirm to IEC 61730 Part-1 & Part-2 and IS-17210 (Part-I) or IEC 62804-1 (PID). For use in a highly corrosive atmosphere throughout their life time, modules must qualify to IEC 61701/IS 61701. (j) It shall also be in conformity to latest minimum technical specifications issued by MNRE & IREDA from time to time. DCR Modules should be of MNRE's ALMM & IREDA approved companies and as per latest IEC/IS standards. (k) Plants installed in high dust geographies like Punjab must have the solar modules tested with relevant dust standards (Applicable standard would be IEC 60068-2-68). (l) Both PV cells and SPV modules shall be make in India. (m) Each structure should have angle of inclination as per the site conditions to generate maximum power. (n) Any damage to the existing roof treatment of any type due to the Installation of Solar Power System shall be Re-done/made good as per existing treatment. Cost of the same shall be deemed to be included in the unit rate quoted. Nothing extra shall be admissible on this account.
(B) DC distribution/ Junction Boxes : S&F DC junction boxes of suitable capacity, rating & Nos (as per design approved)/ OEM recommendations having suitably rated inputs and output terminals having separate DC fuses for both (+) & (-) on input and isolator on output terminal for each string. Each junction box must have a spare input terminal. The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plastic with IP 65 protection or better standard in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and suitable arrangement for earthing connections as per relevant standard. The junction box shall have suitable arrangement of the following :- (a) The strings are required to be connected to the copper bus bar/ switch gear through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each string/SJB/ SCB. (c) Provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard/ IS standard. (e) The incoming and outgoing cables from box, panel shall be properly sealed through proper glands. (f) Each array junction box shall have suitable bypass & reverse blocking diodes for maximum DC blocking voltage of 1000V or system voltage as approved designed with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. Make : As per OEM
(D) Module Mounting Structure (MMS): Design, supply/ procure, fixing, module mounting & support structure made of hot dipped galvanised iron with min 80 micron thickness including necessary RCC foundation (as applicable) and associated iron work cutting, drilling, welding, jointing, grouting, PCC/ RCC filling, disposing waste material, etc., complete and fixing mounting arrangement suitable for SPV modules so as it can withstand wind speed of 200 km per hour. The mounting structure is to be installed at RCC Roofs (as existing at site) and the array structure has to be so designed that maximum load is directly on roof beams and columns to avoid any affect on life & strength of structure. It shall also occupy minimum space without sacrificing the output of SPV panels & adequate space between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, mounting structure including module mounting structure shall have to be adequately protected from the atmosphere and weather prevailing in the area. All the fasteners, nut, bolts shall be of Stainless Steel of grade SS 304 or hot dip galvanized. Module mounting structure may require to customize with respect to the site availability and in case, if any water tank is present on the roof, then mounting structure height should be more than 1.5 feet (min) above the water tank height so that space of water tank should be fully utilized for installation of PV module and to avoid any shadow of water tanks on modules. Notes for MMS: (a) Two numbers of anti-theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) The module mounting structure shall be installed to provide maximum generation. (c) The contractor shall submit structural design on Stad-Pro based or equivalent software on wind load 200 Kmph, live load and dead load of structure with solar panel & seismic zone, wind speed zone of Jalandhar, Punjab. Any deflection to the mounting structure shall be as per IS 800:2007. Structural design of the mounting structure should be carried out by a consultant/ company approved by the GE. The height of Roof top MMS shall be as per latest MNRE & IREDA guidelines for ease in maintenance.
(d) Any damage done to water proofing/ Roof structure during installation shall be made good by the contractor at no extra cost. Water Leak Protection has to be ensured with Pure Epoxy Resin based chemical anchoring system, wherever damage to structure occurs. (e) MMS steel shall be as per latest IS 2062: 2011 and galvanization of mounting structure shall be in compliance of IS 4759. (e) MMS steel shall be as per latest IS 2062: 2011 and galavnization of mounting structure shall be in compliance of IS 4759. (f) The PV array structure design shall be appropriate with a factor of safety 1.5 min or higher factor of safety. (g) The mounting structure shall have reqd rafters, Purlins, front bracing, back bracing for proper installation of solar SPV.
(b) NET METER (as applicable): CT/ VT operated bidirectional energy meter (as reqd) with following features :- (i) True four quadrant metering (ii) Import/ export metering and forwarded metering option for LT systems (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with annunciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery.
General Notes for SPV Plant System : (a) The contractor must visit the site before quoting the rates to assess the site conditions so as to decide up on location and layout of SPV, placement of inverter as per buildings, length of DC cables, AC cables, lightning arresters, earthing, mounting structure etc. complete. (b) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, location/ placement of LAs, Civil work, etc., complete as per MNRE/ IREDA latest guidelines as applicable, relevant IEC/IS norms to the GE for approval within one month of date of commencement of the work for approval. Design calculation: The tenderer should work out design based on the conditions prevalent at Jalandhar , Punjab. The complete design and installation and layout of solar roof system be carried out in consonance with MNRE latest guidelines for roof top solar phase and preliminary solar panel direction layout, structure design with Stad pro/ equivalent software and single line diagram be ratif
ied by MNRE empanelled charted Engr/ firm/ consultant. The dimensioned drawing of the site of work clearly marked with all sub systems components etc. shall be submitted to GE for approval which shall be self-contained and self-explanatory representation of layout of equipment and subsystems. Schematic diagram of the electrical system. This shall contain specification, size, current, voltage and fault levels rating of all cables, switch gears and instrumentation & control systems and all metering and interlocking etc. Schematic diagram of the electrical system. This shall contain specification, size, current, voltage and fault levels rating of all cables,switch gears and instrumentation & control systems and all metering and interlocking etc. All the documents/ technical details mentioned above duly vetted as specified above shall be approved by GE. GE may approve the documents as submitted by the Contractor or may suggest modification/ alteration in documents/technical specifications duly supported with reasons for the same. The work shall be executed based on the approved documents.
wooden board including catalogue board. (c) Foundation for mounting of DG set shall be done as per manufacturer design within overall cost quoted. (UG OPS room & Perimeter security lights near blast pens))
Design, supply, erection, installation, testing and commissioning of ON GRID type Roof Top Solar Photo Voltaic Power Plant system of 7.5 KW capacity complete comprising of DCR Solar Photo Voltaic Modules (cap as specified under in required quantity to make full cap 7.5 kW), Inverters/ PCUs, Module mounting structure, Net meter (as applicable) , Generation meter, Array Junction boxes, DC junction/ distribution boxes, AC junction/ distribution boxes, Solar grade DC copper cables, AC cables, Lightning arrestor, surge arrestor, earthing, civil RCC/ PCC/ earth work, Ladders, below mentioned items, BOS, accessories complete including miscellaneous items required for satisfactory functioning of roof top solar power plant suitable to be installed at Servant Qtrs and Offr Mess under GE Gurdaspur, Punjab.
Supply, installation, commissioning and testing of eco-friendly Diesel Engine driven generating set silent type confirming to CPCB IV condition/ norms, 25 KVA (20 KW) rating as per BS-5514, 03 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM, 415 volts (AC 3 phase,4 wire system of supply) 50 Hz at 0.8 power factor directly coupled alternator & engine, water cooled, mounted on common base plate of rigid fabricated mild steel frame platform with floor mounted fuel tank of suitable capacity(minimum 12 hrs capacity of consumption) & including all excavation PCC foundation, anti-vibration pads/ dampers including standard control panel other accessories as per manufacturer's design. The Gen set should be fitted with integrated acoustic enclosure manufactured by the OEM of the Generating set .The Generating Set and acoustic enclosure shall confirm to emission norms and noise level. The acoustic enclosure shall be type tested and certificate obtained for the type approved from approved agencies listed in Govt. Notification. Specifications of DG set shall be as specified and comprising of the following: - (A) ENGINE (Prime mover): Diesel engine vertical type of adequate capacity for 25 KVA (20 KW), 03 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM under NTP conditions of BS: 5514, turbo charged water cooled, compression ratio 17.3:1, 02 No. x 12 volts 120 Ah electric battery start, complete with fly wheel and all standard fittings/ fixtures as per manufacturer instructions including suitable engine control panel/dash Board with electronic tachometer. Lubrication oil temperature & pressure gauges water temp gauge and frequency meter (digital type) including safety automatic shutdown in case of fault such as high water temperature low oil pressure, over speed etc. including self-starter, alternator, cogged, V-belt, fuel tank with first fill of lubricating oil and coolant (as applicable) etc. complete all as specified. (B) ALTERNATOR: Alternator AC, 3 phase 415 volts 4 wire rated line current for output 25 KVA, PF 0.8, 1500 RPM confirming to BS 5000 directly coupled with above engine. The Alternator shall be brushless type, screen protected, revolving field, self-exited, self-regulated through an AVR. The alternator has the following features :- (a) + 0.5% voltage regulation (max) in static conditions. (b) IP-23 protection with insulation class H (c) Permissible overload of 10% for one hour in 12 hours of operation. (d) Anti-vibration pads for mounting engine and alternator assembly on the base frame/ plate or as recommended/ provided by the manufacturer. (C) Base frame made out of structural steel as per manufacturer's recommended design/ specifications.
Supply, installation, commissioning and testing of eco-friendly Diesel Engine driven generating set silent type confirming to CPCB IV condition/ norms, 58.5 KVA (47 KW) rating as per BS-5514, 04 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM, 415 volts (AC 3 phase,4 wire system of supply) 50 Hz at 0.8 power factor directly coupled alternator & engine, water cooled, mounted on common base plate of rigid fabricated mild steel frame platform with floor mounted fuel tank of suitable capacity(minimum 12 hrs capacity of consumption) & including all excavation PCC foundation, anti-vibration pads/ dampers including standard control panel other accessories as per manufacturer's design. The Gen set should be fitted with integrated acoustic enclosure manufactured by the OEM of the Generating set .The Generating Set and acoustic enclosure shall confirm to emission norms and noise level. The acoustic enclosure shall be type tested and certificate obtained for the type approved from approved agencies listed in Govt. Notification. Specifications of DG set shall be as specified and comprising of the following: - (A) E
d have a nominal power output more than 90% at STC during the first Ten years and more than 80% during next 15 years. Further, module shall have nominal power output of more than 97% during the first year of installation.
(e) Each module shall have RFID tag encapsulated/ laminated inside glass. Following information must be mentioned in RFID (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell (iii) Month and year of Manufacturing (separately for solar cell and module) (iv) Country of Origin for solar cell and module (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no and model no of module (viii) IV curve of module (f) The temperature coefficient (Power) for the PV module shall not be more than - 0.40% per degree Celcius. (g) Every module must have bypass diode of suitable capacity. (h) PV module must confirm to latest edition of IEC 61215/ IS 14286, IEC 61853 Part I or IS 16170 Part-I. In addition the modules must confirm to IEC 61730 Part-1 & Part-2 and IS-17210 (Part-I) or IEC 62804-1 (PID). For use in a highly corrosive atmosphere throughout their life time, modules must qualify to IEC 61701/IS 61701. (j) It shall also be in conformity to latest minimum technical specifications issued by MNRE & IREDA from time to time. DCR Modules should be of MNRE's ALMM & IREDA approved companies and as per latest IEC/IS standards.
(B) DC distribution/ Junction Boxes : S&F DC junction boxes of suitable capacity, rating & Nos (as per design approved)/ OEM recommendations having suitably rated inputs and output terminals having separate DC fuses for both (+) & (-) on input and isolator on output terminal for each string. Each junction box must have a spare input terminal. The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plastic with IP 65 protection or better standard in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and suitable arrangement for earthing connections as per relevant standard. The junction box shall have suitable arrangement of the following :- (a) The strings are required to be connected to the copper bus bar/ switch gear through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each string/SJB/ SCB. (c) Provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard/ IS standard. (e) The incoming and outgoing cables from box, panel shall be properly sealed through proper glands. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for maximum DC blocking voltage of 1000V or system voltage as approved designed with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. Make : As per OEM
(D) Module Mounting Structure (MMS): Design, supply/ procure, fixing, module mounting & support structure made of hot dipped galvanised iron with min 80 micron thickness including necessary RCC foundation (as applicable) and associated iron work cutting, drilling, welding, jointing, grouting, PCC/ RCC filling, disposing waste material, etc., complete and fixing mounting arrangement suitable for SPV modules so as it can withstand wind speed of 200 km per hour. The mounting structure is to be installed at RCC Roofs (as existing at site) and the array structure has to be so designed that maximum load is directly on roof beams and columns to avoid any effect on life & strength of structure. It shall also occupy minimum space without sacrificing the output of SPV panels & adequate space between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, mounting structure including module mounting structure shall have to be adequately protected from the atmosphere and weather prevailing in the area. All the fasteners, nut, bolts shall be of Stainless Steel of grade SS 304 or hot dip galvanized. Module mounting structure may require to customize with respect to the site availability and in case, if any water tank is present on the roof, then mounting structure height should be more than 1.5 feet (min) above the water tank height so that space of water tank should be fully utilized for installation of PV module and to avoid any shadow of water tanks on modules. Notes for MMS: (a) Two numbers of anti-theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) The module mounting structure shall be installed to provide maximum generation. (c) The contractor shall submit structural design on Stad-Pro based or equivalent software on wind load 200 Kmph, live load and dead load of structure with solar panel & seismic zone, wind speed zone of Jalandhar, Punjab. Any deflection to the mounting structure shall be as per IS 800:2007. Structural design of the mounting structure should be carried out by a consultant/ company approved by the GE. The height of Roof top MMS shall be as per latest MNRE & IREDA guidelines for ease in maintenance.
(d) Any damage done to water proofin
Design, supply, erection, installation, testing and commissioning of ON GRID type Roof Top Solar Photo Voltaic Power Plant system of 7.5 KW capacity complete comprising of DCR Solar Photo Voltaic Modules (cap as specified under in required quantity to make full cap 7.5 kW), Inverters/ PCUs, Module mounting structure, Net meter (as applicable) , Generation meter, Array Junction boxes, DC junction/ distribution boxes, AC junction/ distribution boxes, Solar grade DC copper cables, AC cables, Lightning arrestor, surge arrestor, earthing, civil RCC/ PCC/ earth work, Ladders, below mentioned items, BOS, accessories complete including miscellaneous items required for satisfactory functioning of roof top solar power plant suitable to be installed at Servant Qtrs and Offr Mess under GE Gurdaspur, Punjab.
Supply, installation, commissioning and testing of eco-friendly Diesel Engine driven generating set silent type confirming to CPCB IV condition/ norms, 25 KVA (20 KW) rating as per BS-5514, 03 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM, 415 volts (AC 3 phase,4 wire system of supply) 50 Hz at 0.8 power factor directly coupled alternator & engine, water cooled, mounted on common base plate of rigid fabricated mild steel frame platform with floor mounted fuel tank of suitable capacity(minimum 12 hrs capacity of consumption) & including all excavation PCC foundation, anti-vibration pads/ dampers including standard control panel other accessories as per manufacturer's design. The Gen set should be fitted with integrated acoustic enclosure manufactured by the OEM of the Generating set .The Generating Set and acoustic enclosure shall confirm to emission norms and noise level. The acoustic enclosure shall be type tested and certificate obtained for the type approved from approved agencies listed in Govt. Notification. Specifications of DG set shall be as specified and comprising of the following: - (A) ENGINE (Prime mover): Diesel engine vertical type of adequate capacity for 25 KVA (20 KW), 03 Cylinder, inline, 4 stoke cycle, water cooled turbocharged, at 1500 RPM under NTP conditions of BS: 5514, turbo charged water cooled, compression ratio 17.3:1, 02 No. x 12 volts 120 Ah electric battery start, complete with fly wheel and all standard fittings/ fixtures as per manufacturer instructions including suitable engine control panel/dash Board with electronic tachometer. Lubrication oil temperature & pressure gauges water temp gauge and frequency meter (digital type) including safety automatic shutdown in case of fault such as high water temperature low oil pressure, over speed etc. including self-starter, alternator, cogged, V-belt, fuel tank with first fill of lubricating oil and coolant (as applicable) etc. complete all as specified. (B) ALTERNATOR: Alternator AC, 3 phase 415 volts 4 wire rated line current for output 25 KVA, PF 0.8, 1500 RPM confirming to BS 5000 directly coupled with above engine. The Alternator shall be brushless type, screen protected, revolving field, self-exited, self-regulated through an AVR. The alternator has the following features :- (a) + 0.5% voltage regulation (max) in static conditions. (b) IP-23 protection with insulation class H (c) Permissible overload of 10% for one hour in 12 hours of operation. (d) Anti-vibration pads for mounting engine and alternator assembly on the base frame/ plate or as recommended/ provided by the manufacturer. (C) Base frame made out of structural steel as per manufacturer's recommended design/ specifications.
xtures and accessories of AFLS shall be deemed to be within the scope of the specifications whether mentioned or not specifically mentioned in BOQ, but essentially required for final completion and testing/ commissioning of AFLS. The contractor shall ensure the following during execution of AFLS works:- (i) GPS survey before installation of AFLS shall be carried out at no extra cost through specialist agency and report must be submitted within 7 days of survey to the GE. (ii) Subsequently the contractor in consultation with specialist agency shall submit a layout plan of control wiring/ Airfield cabling work, DWC HDPE piping work, with consideration of future expansion and will obtain approval from GE/ Users before commencement of AFLS construction of rigid pavement work. (d) In addition to the qualification testing & mechanical testing of Air Field Lighting System prescribed under ICAO Annex-14, following checks will be carried out by the user & GE. Necessary arrangement will be carried out by the contractor/ Specialist Agency:- (i) Pre acceptance checks as per Annex ‘A’ (AFLS). (ii) Endurance check as Annex ‘B’ (ALFS). (iii) Final acceptance check.0͓Ȉ一瑯獥䘠牯䤠整牓潎ㄠ⸳琠㌱㈮‷䌨湯摴㨩⠊⥥吠敨爠瑡獥焠潵整湵敤敲敬慶瑮椠整獭漠佂⁑牡敤浥摥琠敢椠据畬楳敶漠湥慧敧敭瑮漠楁晲敩摬传䵅䔠杮湩敥獲爠杩瑨映潲灡牰癯污畳灰祬漠䙁卌映瑩楴杮愠摮映硩畴敲捡散獳牯敩ⱳ愠摮䄠物楦汥慣汢瑥畳数癲獩潩畤楲杮攠數畣楴湯整瑳湩湡潣浭獩楳湯湩湡慨摮湩癯牥琠桴湵瑩愠摮琠敨猠潣数漠潷歲洠湥楴湯摥瘠摩潮整⠠⥣☠⠠⥤愠潢敶桔慲整畱瑯摥椠佂⁑条楡獮⁴慥档椠整獭漠䙁卌眠汩敢椠据畬楳敶漠污敤慴汩敲畱物摥映牯椠獮慴汬瑡潩Ɱ琠獥楴杮☠挠浯業獳潩楮杮漠桴䙁卌椠牲獥数瑣癩景搠獥牣灩楴湯景椠整獭漠佂⹑⠊⥦吠敨挠湯牴捡潴桳污畳浢瑩㌠礠慥獲眠牡慲瑮敥映潲慭畮慦瑣牵牥映潲桴慤整漠潣灭敬楴湯桔潣瑮慲瑣牯猠慨汬愠獬畳浢瑩琠獥⁴敲潰瑲琠湅楧敮牥椭桃牡敧湁⁹敤敦瑣漠捣牵楲杮搠牵湩桴獩瀠牥潩桳污敢爠捥楴楦摥映敲景挠獯⁴祢琠敨挠湯牴捡潴,דȈ䜀久剅䱁䐠呅䥁卌ⴺ⠊⥡†瑓湡扤⁹灯牥瑡潩潣獮浵瑰潩愨⁴楮桧⥴㨠㰠㈠圠⠊⥢丠潬摡氠獯敳㩳䰠獥桴湡ㄠ‥景爠瑡摥瀠睯牥⠊⥣䄠汬睯扡敬删汥瑡癩畈業楤祴爠条›‰⁾〱‰ਥ搨 流楢湥⁴整灭牥瑡牵慲杮›㔲䎺琠〶䎺ਮ攨 䄠瑣癩潰敷摁番瑳扡敬爠湡敧㨠〠縠ㄠ〰┠⠊⥦吠灯汯杯⁹›牔湡晳牯敭汲獥ੳ木 湉整牧瑡摥䐠⁃睳瑩档㨠夠獥⠊⥨†牐瑯捥楴湯㨠†桔湩敶瑲牥猠潨汵慨敶瀠潲楶楳湯景䜠污慶楮獩汯瑡潩Ɱ愠瑮獩慬摮湩牰瑯捥楴湯⠠䕉䕅ㄠ㐵⼷䱕ㄠ㐷⤱攠畱癩污湥⁴卉䍄删癥牥敳倠汯牡瑩⁹牰瑯捥楴湯畏灴瑵漠敶捲牵敲瑮☠漠瑵異⁴癯牥瘠汯慴敧瀠潲整瑣潩Ɱ朠潲湵慦汵⁴潭楮潴楲杮牧摩洠湯瑩牯湩Ⱨ䄠⁃湡䍄猠潨瑲挠物畣瑩挠牵敲瑮愠摮漠敶畣牲湥ⱴ䄠⁃湡䍄漠敶潶瑬条湡癯牥琠浥数慲畴敲瀠潲整瑣潩䍁☠䐠⁃畓杲牰瑯捥楴湯牰癥湥⁴楬桧湴湩慤慭敧攠捴⠊⥪䤠杮敲獳倠潲整瑣潩›偉㘠‵牯戠瑥整ੲ欨 敒潭整䴠湯瑩牯湩›楗楦 假卒 卒㐠㔸愠敮散獳瑩瑡摥戠⁹楳整挠湯楤楴湯…楤敲瑣摥戠⁹䕇敗慢敳潭楮潴楲杮眠瑩楨瑳牯捩污搠瑡瑳牯条潦湡污獹獩⠊⥬䐠獩汰祡›䍌洨 慗牲湡祴㨠㔠礠慥獲䴠湩ਮ渨 †桔湩敶瑲牥猠慨汬愠橤獵⁴潶瑬条湡牦煥敵据⁹敬敶獬琠畳瑩琠敨朠楲⠊⥯†桔湩敶瑲牥猠慨汬戠敳晬挭浯畭慴整眠瑩畐獬楗瑤潍畤慬楴湯⠠坐⥍琠捥湨汯杯⁹湡桳污敢挠灡扡敬漠祳据牨湯獩慭楸畭楷桴湩漠敮洠湩瑵牯氠獥楴敭ਮ瀨 †慍楸畭潐敷潐湩⁴牔捡敫䴨偐⥔猠慨汬戠湩整牧瑡摥椠桴湩敶瑲牥 䍐⁕潴洠硡浩穩湥牥祧搠慲湷映潲桴牡慲䌠慨杲潣瑮潲汬牥⠠晩愠祮⼩䴠偐⁔湵瑩湥楶潲浮湥慴整瑳湩桳畯摬焠慵楬祦䤠䍅㘠〰㠶㈭⠠ⰱⰲ㐱㌬⤰ 煅極慶敬瑮䈠卉猠慴摮牡 ѳЉ⠀䠀⤀ 䴀攀琀攀爀椀渀最㨀 儀甀漀琀攀搀 爀愀琀攀猀 椀渀挀氀甀猀椀瘀攀 漀昀 椀渀猀琀愀氀氀愀琀椀漀渀 漀昀 昀漀氀氀漀眀椀渀最 洀攀琀攀爀猀⸀ 匀甀椀琀愀戀氀攀 搀甀愀氀 洀攀琀攀爀椀渀最 愀爀爀愀渀最攀洀攀渀琀猀 眀椀琀栀 爀攀挀漀爀搀椀渀最 昀愀挀椀氀椀琀礀 猀栀愀氀氀 戀攀 瀀爀漀瘀椀搀攀搀⸀ 吀栀攀 洀攀琀攀爀椀渀最 愀爀爀愀渀最攀洀攀渀琀猀 洀甀猀琀 栀愀瘀攀 昀攀愀琀甀爀攀 琀漀 洀攀愀猀甀爀攀 愀渀搀 爀攀挀漀爀搀 瀀愀爀愀洀攀琀攀爀猀 漀昀 䬀圀Ⰰ 䬀圀栀Ⰰ 䬀嘀䄀刀Ⰰ 瘀漀氀琀愀最攀Ⰰ 挀甀爀爀攀渀琀Ⰰ 倀䘀 愀渀搀 愀渀礀 漀琀栀攀爀 洀攀琀攀爀椀渀最 爀攀焀甀椀爀攀搀 琀漀 搀攀琀攀爀洀椀渀攀 攀昀昀椀挀椀攀渀挀礀 愀渀搀 攀昀昀椀挀愀挀礀 漀昀 琀栀攀 猀礀猀琀攀洀 挀漀洀瀀氀攀琀攀 愀猀 甀渀搀攀爀㨀ⴀ 愀⤀ 䜀攀渀攀爀愀琀椀漀渀⼀ 䌀栀攀挀欀 䴀攀琀攀爀椀渀最 䄀爀爀愀渀最攀洀攀渀琀猀㨀 䰀吀 ㌀ 倀栀愀猀攀 㐀 圀椀爀攀 䔀氀攀挀琀爀漀渀椀挀 吀爀椀瘀攀挀琀漀爀 䴀攀琀攀爀 眀椀琀栀 爀攀焀搀 䌀吀 爀愀琀椀漀⼀ 吀漀琀愀氀 眀愀琀琀栀漀甀爀 洀攀琀攀爀 猀栀漀甀氀搀 戀攀 愀猀 瀀攀爀 挀愀瀀愀挀椀琀礀 漀昀 匀倀嘀 瀀氀愀渀琀⸀⠀椀⤀ 匀琀愀渀搀愀爀搀㨀 䤀匀 ㌀㜀㜀㤀㨀㈀ ㈀ ⠀椀椀⤀ 䄀挀挀甀爀愀挀礀㨀 䌀氀愀猀猀 漀爀 戀攀琀琀攀爀⠀椀椀椀⤀ 刀攀昀攀爀攀渀挀攀 嘀漀氀琀愀最攀 ⴀ ㌀砀㈀㐀 嘀⠀椀瘀⤀ 䈀愀猀椀挀 䌀甀爀爀攀渀琀 ⠀䤀戀⤀ ⴀ 㔀 䄀 漀爀 愀猀 瀀攀爀 䤀匀 猀琀愀渀搀愀爀搀 愀瀀瀀氀椀挀愀戀氀攀 ⠀瘀⤀ 䴀愀砀椀洀甀洀 挀漀渀琀椀渀甀漀甀猀 挀甀爀爀攀渀琀 ⠀䤀洀愀砀⤀ ⴀ 䄀猀 爀攀焀搀 昀漀爀 挀愀瀀 漀昀 猀漀氀愀爀 瀀漀眀攀爀 瀀氀愀渀琀⠀瘀椀⤀ 刀愀琀攀搀 䘀爀攀焀甀攀渀挀礀 ⴀ 㔀 䠀稀 ⠀瘀椀椀⤀ 倀漀眀攀爀 挀漀渀猀甀洀瀀琀椀漀渀㨀ⴀ 䄀猀 瀀攀爀 䤀匀 猀琀愀渀搀愀爀搀⠀瘀椀椀椀⤀ 䐀椀猀瀀氀愀礀 琀礀瀀攀㨀 㠀 搀椀最椀琀 㜀 猀攀最洀攀渀琀 戀愀挀欀氀椀琀 䰀䌀䐀 搀椀猀瀀氀愀礀⠀椀砀⤀ 䌀漀洀洀甀渀椀挀愀琀椀漀渀 瀀漀爀琀㨀 䜀愀氀瘀愀渀椀挀愀氀氀礀 椀猀漀氀愀琀攀搀 伀瀀琀椀挀愀氀 䌀漀洀洀甀渀椀挀愀琀椀漀渀 瀀漀爀琀 昀漀爀 搀愀琀愀 琀爀愀渀猀昀攀爀 琀栀爀漀甀最栀 攀椀琀栀攀爀 䌀䴀刀䤀 漀爀 爀攀洀漀琀攀 搀攀瘀椀挀攀 漀爀 戀漀琀栀 椀猀 瀀爀漀瘀椀搀攀搀 眀椀琀栀 刀匀 㐀㠀㔀 昀漀爀 䐀䰀䴀匀 瀀爀漀琀漀挀漀氀⠀砀⤀ 䔀渀攀爀最礀 爀攀挀漀爀搀椀渀最 ጀ†唀渀椀搀椀爀攀挀琀椀漀渀愀氀 ༀༀఀ稀༁ꌀఁ먀ࠈ䐨 䴠摯汵潍湵楴杮匠牴捵畴敲⠠䵍⥓›敄楳湧畳灰祬 牰捯牵ⱥ映硩湩Ⱨ洠摯汵潭湵楴杮☠猠灵潰瑲猠牴捵畴敲洠摡景栠瑯搠灩数慧癬湡獩摥椠潲楷桴洠湩㠠‰業牣湯琠楨正敮獳椠据畬楤杮渠捥獥慳祲删䍃映畯摮瑡潩愨灡汰捩扡敬 湡獡潳楣瑡摥椠潲潷歲挠瑵楴杮牤汩楬杮敷摬湩Ⱨ樠楯瑮湩Ⱨ朠潲瑵湩Ⱨ倠䍃 䍒⁃楦汬湩Ⱨ搠獩潰楳杮眠獡整洠瑡牥慩ⱬ攠捴Ⱞ挠浯汰瑥湡楦楸杮洠畯瑮湩牡慲杮浥湥⁴畳瑩扡敬映牯匠噐洠摯汵獥猠獡椠⁴慣楷桴瑳湡楷摮猠数摥漠〲‰浫瀠牥栠畯吠敨洠畯瑮湩瑳畲瑣牵獩琠敢椠獮慴汬摥愠⁴䍒⁃潒景愨硥獩楴杮愠⁴楳整 湡桴牡慲⁹瑳畲瑣牵慨潴戠潳搠獥杩敮桴瑡洠硡浩浵氠慯獩搠物捥汴⁹湯爠潯敢浡湡潣畬湭潴愠潶摩愠祮攠晦捥⁴湯氠晩…瑳敲杮桴漠瑳畲瑣牵䤠⁴桳污污潳漠捣灵⁹業楮畭灳捡楷桴畯⁴慳牣晩捩湩桴畯灴瑵漠偓⁖慰敮獬☠愠敤畱瑡灳捡敢睴敥桴牡慲獹猠慨汬戠癡楡慬汢潦慥祳挠敬湡湩湡慭湩整慮据丠瑵ⱳ戠汯獴潭湵楴杮猠牴捵畴敲椠据畬楤杮洠摯汵潭湵楴杮猠牴捵畴敲猠慨汬栠癡潴戠摡煥慵整祬瀠潲整瑣摥映潲桴瑡潭灳敨敲愠摮眠慥桴牥瀠敲慶汩湩湩琠敨愠敲䄠汬琠敨映獡整敮獲畮ⱴ戠汯獴猠慨汬戠景匠慴湩敬獳匠整汥漠牧摡卓㌠㐰漠潨⁴楤⁰慧癬湡穩摥䴠摯汵潭湵楴杮猠牴捵畴敲洠祡爠煥極敲琠畣瑳浯穩楷桴爠獥数瑣琠桴楳
(e) Each module shall have RFID tag encapsulated/ laminated inside glass. Following information must be mentioned in RFID:- (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell (iii) Month and year of Manufacturing (separately for solar cell and module) (iv) Country of Origin for solar cell and module (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no and model no of module (viii) IV curve of module (f) The temperature coefficient (Power) for the PV module shall not be more than - 0.40% per degree Celsius. (g) Every module must have bypass diode of suitable capacity. (h) PV module must confirm to latest edition of IEC 61215/ IS 14286, IEC 61853 Part I or IS 16170 Part-I. In addition the modules must confirm to IEC 61730 Part-1 & Part-2 and IS-17210 (Part-I) or IEC 62804-1 (PID). For use in a highly corrosive atmosphere throughout their life time, modules must qualify to IEC 61701/IS 61701. (j) It shall also be in conformity to latest minimum technical specifications issued by MNRE & IREDA from time to time. DCR Modules should be of MNRE's ALMM & IREDA approved companies and as per latest IEC/IS standards. (k) Plants installed in high dust geographies like Punjab must have the solar modules tested with relevant dust standards (Applicable standard would be IEC 60068-2-68). (l) Both PV cells and SPV modules shall be make in India. (m) Each structure should have angle of inclination as per the site conditions to generate maximum power. (n) Any damage to the existing roof treatment of any type due to the Installation of Solar Power System shall be Re-done/made good as per existing treatment. Cost of the same shall be deemed to be included in the unit rate quoted. Nothing extra shall be admissible on this account.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.33 MB
SDWDPART6.pdf
Additional Documents • 4.57 MB
SDWDPART7.pdf
Additional Documents • 4.19 MB
SDWDPART2.pdf
Additional Documents • 5.40 MB
SDWDPART3.pdf
Additional Documents • 4.69 MB
STD_DRG_1.pdf
Additional Documents • 35.79 MB
TenderDocuments81068.pdf
Tender Documents • 4.25 MB
SDWDPART4.pdf
Additional Documents • 4.07 MB
STD_DRG_2.pdf
Additional Documents • 2.58 MB
SDWDPART5.pdf
Additional Documents • 3.68 MB
SDWDPART1.pdf
Additional Documents • 5.33 MB
TD_DRG.pdf
Additional Documents • 35.85 MB
BOQ_822415.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid