Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | Admitted-Finance |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
17 Oct 2024, 6:00 pmClosed
GE Amritsar
GARRISON ENGINEER AMRITSAR CANTT PIN -143001
EPAIR/MAINTENANCE OF SUBMERSIBLE PUMPS AT DIFFERENT LOCATION OF OLD AMRITSAR CANTT, GG FORT, VALLAH DUMP AND SWIMMING POOL INCLUDING ALLIED WORKS UNDER GARRISON ENGINEER AMRTISAR CANTT
2024_MES_675146_1
GE/ASR-71/2024-25
Open Tender
Civil Works
Works
180 days
GE Amritsar
CLASS E CATEGORY b i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹50,000
24 Oct 2024
18 Sept 2024
18 Oct 2024
18 Sept 2024
17 Oct 2024
3 Oct 2024
Amount
Material and Labour for opening of foundation nuts, bolts, coupling and transportation of unserviceable centrifugal/booster pump-motor upto 15 HP capacity HP upto repair workshop, dismantling all parts, segregating serviceable and worn out parts, carry out repair work, re-assembling the centrifugal/booster pump, re-transportation and re-installation of pump at its original location and testing for proper functioning ; Complete all as specified and directed by Engineer-in-charge. NOTE: (a) Major spare parts required for repair shall be paid as supply only under serial item No. 02 to 06 here-in-after, where as any minor parts/misc. parts i.e., gasket set, S/s shaft, gun metal threaded washer ring, fully treaded studs, MS gland packing cover plates, CI impeller, rubber bush suitable for coupling etc., those which are not catered in Sch 'A' and required for smooth functioning of pump are deemed to be included in the quoted rates. (b) The contractor will furnish six months warranty against any kind of defect for the repair carried out after the date of installation. (c) Rate shall be inclusive of loading/unloading and transporting to & from workshop.
Supply only key impeller as per sample suitable for booster pump ; Complete all as specified and directed by Engineer-in-charge.
Supply only deep groove ball bearing of suitable size for booster pump ; Complete all as specified and directed by Engineer-in-charge.
Supply only set of mild steel coupling with hard rubber bushes suitable of pump & motor having opening as per the shaft and grooves for key all as per sample ; Complete all as specified and directed by Engineer-in-charge.
Supply only adopter made out of graded cast iron as per sample suitable for booster pump ; Complete all as specified and directed by Engineer-in-charge.
Supply only CI impeller as per sample suitable for booster pump ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for opening of foundation nuts, bolts, coupling and transportation of unserviceable centrifugal/booster pump-motor of size upto 15 HP capacity, taking out the burnt windings, cleaning and washing of slots and re-winding the same by super enamelled water proof & insulated copper wire of existing gauge with same number of turns (as per original manufacturer design), providing insulating materials such as insulating sheets insulating paper (Class "F"), insulating heat resistant sleeves, sealing compounds varnish etc and re-assembling the motor, re-transportation and re-installation of pump-motor at its original location and testing for proper functioning ; Complete all as specified and directed by Engineer-in-charge. NOTE: (a) The contractor will furnish six months warranty against any kind of defect for the repair carried out after the date of installation. (b) Submersible cable for connection of suitable size miniᵐ 3 mtr each length from motor will be included in quoted rates. (c) Rate shall be inclusive of loading/unloading and transporting to & from workshop.
Material and Labour for lifting of submersible pump-motor assembly of capacity 50 to 60 HP alongwith flanged column pipe of any size, submersible cable, safety rope, etc. from the existing borewell with chain pulley arrangements & engaging sufficient man power to ensure safety of plant as well as working persons, etc., disconnecting of delivery main lines, dismantling the column pipe, by opening of nuts & bolts, pump and motor, disconnecting electric connections, etc., segregating & stacking serviceable and unserviceable items complete, re-assembling the pump-motor after repair, making electrical connections, lowering of submersible pump motor assembly by the chain pulley, connecting water supply delivery mains, etc., ; Complete all as specified and directed by Engineer-in-charge. NOTE FOR SER ITEM NO. 08 TO 12 : (a) Rate shall be inclusive of loading/unloading and transporting to & from workshop. (b) Any major spare parts required for repair shall be paid separately as supply only under ser item No. 09 to 22 here-in-after, where as any minor parts i.e. S/s sleeve, brush CI impellers, efficiency ring, neck ring, ball bearing etc., those are not included in Sch 'A' and required for smooth functioning of pump-motor are deemed to be included in the quoted rates
All as per item No. 08 above but for submersible pump & motor of 35 to 45 HP capacity. ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 08 above but for submersible pump & motor of 20 to 30 HP capacity ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 08 above but for submersible pump & motor of 10 HP to 15 HP capacity ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 08 above but for submersible pump & motor of upto 7.5 HP capacity ; Complete all as specified and directed by Engineer-in-charge.
Supply only column pipe made of galvanized iron pipe, heavy grade, 150mm bore, 3 metre long, both side galvanised, 10mm thick flange duly screwed and welded with GI column pipe and consisting one number ISI marked rubber packing, four numbers 15 mm dia 100 mm long nuts, bolts and washer complete in all respect and ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 06 above but for column pipe of size 100mm bore ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 06 above but for column pipe of size 80mm bore ; Complete all as specified and directed by Engineer-in-charge.
Supply only Gun metal impellers suitable for submersible pump of any capacity ; Complete all as specified and directed by Engineer-in-charge.
Supply only stainless steel shaft of standard size for submersible pump of any capacity ; Complete all as specified and directed by Engineer-in-charge.
Supply only Carbon Thurst bearing suitable for submersible motor any capacity ; Complete all as specified and directed by Engineer-in-charge.
Supply only pump bush suitable for submersible pump any capacity ; Complete all as specified and directed by Engineer-in-charge.
Supply only bowel case suitable for submersible pump-motor any capacity ; Complete all as specified and directed by Engineer-in-charge.
Supply only Rotor filling suitable for submersible motor any capacity ; Complete all as specified and directed by Engineer-in-charge.
Supply only motor bush suitable for submersible motor any capacity ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for dismantling of electric driven submersible motor of capacity 50 to 60 HP, taking out the burnt windings, cleaning and washing of slots and re-winding the same by super enamelled water proof & insulated copper wire of existing gauge with same number of turns (as per original manufacturer design), providing insulating materials such as insulating sheets, insulating paper (Class "F"), insulating heat resistant sleeves, sealing compounds varnish, etc. and re-assembling the motor, re-transportation and re-installation of pump-motor at its original location and testing for proper functioning including making electrical connection complete ; Complete all as specified and directed by Engineer-in-charge. NOTE FOR SER ITEM NO. 23 TO 27: (a) The contractor will furnish six months warranty against any kind of defect for the repair carried out after the date of installation. (b) Submersible cable for connection of suitable size miniᵐ 3 mtr each length from motor will be included in quoted rates. (c) Rate shall be inclusive of loading/unloading and transporting to & from workshop.
All as per item No. 23 above but for submersible pump and motor of 35 to 45 HP capacity ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 23 above but for submersible pump and motor of 20 to 30 HP capacity ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 23 above but for submersible pump and motor of 10 to 15 HP capacity ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 23 above but for submersible pump and motor of up to 7.5 HP capacity ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for checking, inspecting and maintaining for water leakage of centrifugal pump set, sluice valves any size, electrical faults, etc., in different locations at Old Cantt, G G Fort, Vallah damp areas including replacement of required size of gland packing and making leak proof, electrical connections, etc., ; Complete all as specified and directed by Engineer-in-charge. NOTE: (a) Cost of gland packing of required size shall be deemed to be included in the quoted rates. (b) One supervisor will report to the JE in charge on daily basis along with complaint register, complaint slip in duplicate which shall also be arranged by the contractor without any extra cost for recording/monitoring of water supply complaints. (c) Contractor shall arrange at his own expense the security passes for himself, his supervisor, plumbers, electricians and labours as per stn security policy.
Material and Labour for collecting the treated water samples in a sterilized bottle, as and when directed by the deptt. and transporting the samples upto Govt recognized laboratory at Amritsar for carrying out the test as per IS-10500 : 2012 for drinking water and submitting report to the Engr-in-Charge
Supply and Fixing power contactor 3 pole power contactor ML 5, AC-3 rating, 40 Amp, with auxilary 240 V contact including making electrical connections and dismantling of old UNSV one from site complete ; Complete all as specified and directed by Engineer-in-charge. \
All as per item No. 30 above but of rating 70 Amp ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 30 above but of rating 95 Amp ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing over load relay having relay range 25 to 37 Amps built in single phase protection facility, manual & auto reset mode, front access to START and STOP/RESET buttons including making electrical connections and dismantling of old UNSV one from site complete ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 33 above but of range 35 to 45 Amps ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing electronics timer with time delay period of 3 to30 second for 415 volt, 50 Hz, AC supply suitable for star-delta starter for any capacity pump-motor including making electrical connections and dismantling of old UNSV one from site ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing push button actuator standard flush pattern of Red, Green and Yellow (as per site requirement) including making electrical connection and dismantling of old UNSV one from site complete ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing single phase preventor relay with timer, 415 Volts, AC, 6 wires completely fixed with panel including making electrical connections and dismantling of old UNSV one from site complete ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing MCCB triple pole and neutral (4 pole) 200-250 Amp, 415 volts, 50 Hz, of , having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 36 kA including making incoming/outgoing connections and dismantling of old UNSV one from site complete ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 38 above but of 160 Amps 25 kA ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 38 above but of 100 Amps 25 kA ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 38 above but of triple pole (3 pole) 160 Amps 25 kA ; Complete all as specified and directed by Engineer-in-charge.
Supply, laying & testing of XLPE insulated, armoured with multistranded aluminium conductor cable of size 3½ core 95 sqmm nominal cross sectional area conforming to IS-7098 Part-I (1998), heavy duty (Electric power cable) conforming to IS-1554, 1100 Volts grade, stacking laid into trenches/drawn through pipes or in road crossing/floors/along poles/equipments etc., including making electrical connection over pole/panel at one end and into the panel/MCB DB's/Main switch/Change over switch through proper double compression copper gland/lugs/thimbles of suitable size at the another end including taking down old UNSV LTUG cable any type & size from site ; Complete all as specified and directed by Engineer-in-charge. NOTE: (a) Excavation, earthwork, brick protection & cable protection etc. will be measured and paid separately under relevant items of this schedule. (b) Cost of double compression, lugs, thimbles of suitable size will be included in the quoted rate.
All as per item No. 42 above but of size 70 sqmm, 3½ core. ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 42 above but of size 50 sqmm, 3½ core. ; Complete all as specified and directed by Engineer-in-charge.
All as per item No. 42 above but of size 35 sqmm, 3½ core. ; Complete all as specified and directed by Engineer-in-charge.
Supply and connecting flat, water proof, 16 Sqmm, PVC insulated & PVC sheated with electrolytic grade of , annealed, 3 core, 1100 volt grade, multi stranded copper conductor confirming to IS-694/1990, suitable for submersible pump motors incl taking out old unsv from site complete all as specified and directed by Engr-in-Charge.
All as per ser item No. 46 above but of 3 core 10 Sqmm ; Complete all as specified and directed by Engineer-in-charge.
Supply & laying double wall corrugated (DWC) high density poly ethylene (HDPE) of size 50mm dia including all necessary fittings, PN-4 rating, pressure 6 Kgf/cm², conforming to IS-16205 (Part-24) with high ring stiffness & cursh resistance capacity, etc., laid in trench for protection of submersible flat cable ; Complete all as specified and directed by Engineer-in-charge..
All as per item No. 48 above but of size 80 mm dia ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Bib tap standard of PTMT, suitable for 20mm bore GI pipe, any colour high pressure, not less than 125 gms weight, screwed for iron pipe including taking down old UNSV one from site complete ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Ball brass valves, high pressure, with polythene float and fly nut, with epoxy coated Al Rod complete screwed of size 20mm bore for PVC over head tank inside PPR pipe and fixed ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing rotational moulded polyethylene water storage tanks, triple layers of capacity 500 litres, 100% UV stabilised, Cylindrical vertical with closed top, hoisted and fixed in position and connecting up complete all as specified in SSR Part - I ; Complete all as specified and directed by Engineer-in-charge.
Supply and install in replacement of off load change over switch 415 volt AC, 50Hz in sheet steel enclosure, 4 pole of capacity 160 Amps, confirming to IEC-947-3 staggered terminals, site convertible fuse version, interchangeable dual shaft position with site convertibility, to be fixed with suitable bolts, nuts grouted on wall and making electrical connections including dismantling of old UNSV one from site complete all as specified and directed by Engr-in-Charge.
All as per item No. 53 above but of size 100 Amps ; Complete all as specified and directed by Engineer-in-charge.
Repair to Altoch dosing unit by dismantling of pump, motor and other connecting components/accessories and carrying out necessary repair works, making the machine functional, reassembling, fixing in position and testing ; Complete all as specified and directed by Engineer-in-charge.. NOTE: Spare parts required for repair of dozing pump shall be measured and paid under Sl item No 56 to 64 here-in-after under supply only rates
Supply only gear motor complete set with working voltage 230 Volts, 50 Hz. ; Complete all as specified and directed by Engineer-in-charge.
Supply only rotor assembly with bearing brackets and tolerance rings. ; Complete all as specified and directed by Engineer-in-charge.
Supply only field/armature coil 250 Volts, 50 Hz. ; Complete all as specified and directed by Engineer-in-charge.
Supply only roller assembly. ; Complete all as specified and directed by Engineer-in-charge.
Supply only 7 pump tube. ; Complete all as specified and directed by Engineer-in-charge.
Supply only injection check valve 3/8". ; Complete all as specified and directed by Engineer-in-charge.
Supply only 3/8" white suction/discharge tubing. ; Complete all as specified and directed by Engineer-in-charge.
Supply only check value duckbill only (Pkt of 5). ; Complete all as specified and directed by Engineer-in-charge.
Supply only connecting nut 3/8". ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Air release valve with two air outlets (double chamber) conforming to IS:14845, of size 80 mm dia bore, CI body, rubber coated wooden balls, synthetic rubber gaskets, high tensile brass plug, carbon steel bolting suitable for fixing in CI/DI water supply mains, including taking down old UNSV one from site ; Complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 65 above but of size 50 mm bore. ; Complete all as specified and directed by Engineer-in-charge.
Material & labour for DI/CI fittings conforming to IS:9523 for flanged/spigot socketed type DI pieces special any type upto 150mm dia bore such as bends (any type of radious and angle) tapers any type (straight bend increasing, decreasing or double socket etc) Tee pieces, single branch, 'Y' junctions, doubled branch, cross (all sockets and sockets & spigots), collars, caps and plugs ; Complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of CI foot valve flange type of 80mm dia with synthetic metal ball and jointing with suitable size bolts, nuts & washers, including taking down old UNSV one from site ; Complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 68 above but of size 50 mm bore. ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and having dia of neck 11 to 15mm for tightening of CI/DI/GI flanged joint/Sluice valve ; Complete all as specified and directed by Engineer-in-charge..
All as per ser item No. 70 above but length of bolt exc 5cm but n exc 10cm long & neck dia 11 to 15mm ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for preparation of old painted external surfaces of CI/DI/GI pipe of any size, not exc. 60cm girth including holderbats, distance pieces, etc. (length measured over bends, branches etc.) with two coats of synthetic enamel paint of colour as directed by Engr-in-Charge, over a coat of red oxide zinc chrome primer after necessary scrapping off old surface using wire brush inside the Pump House Area complete all as specified and directed by Engr-in-Charge.
Material and Labour for marking Index hands (natural size) or arrows not exc. 40cm long and width 25mm, painted with thick fluorecent paints on pipe line for indicating direction complete all as specified and directed by Engr-in-Charge
Material and Labour for painting one coat of black bituminous/aluminum paint on steel or iron surface of any description, not exc. 10cm width/girth including preparation of old painted surface (i.e. cross arms, bracings, angle iron, clamps etc.) by scrubbing with emery paper around the Pump House Area complete all as specified and directed by Engr-in-Charge. NOTE: Cost of Aluminium/black bituminous paint will be measure and paid as Supply only under relevant items.
Supply only Aluminium paint (in dual containers) ; Complete all as specified and directed by Engineer-in-charge.
Supply only Black bituminous paint ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for preparation of old plastered surfaces including brooming down to remove all dust, dirt and loose scales of item and other foreign matter or steel wire brushing scrapping down smoke soot, grease spots, moulds moss, efforescent salts & trading oil and applying one coat of cement base paint on wall ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in repair to MS plain black sheet of 1.60mm thick in wall cladding, steel gates and similar work, for valve chamber cover cut to size, holes punched, including round headed screws, clout nails or riveting, welding and fixed to and including steel framing of required size with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc., ; Complete all as specified and directed by Engineer-in-charge.
Material and labour for construction of brick masonary pits (230mm thick wall) of 900x600x1000mm internal dimension (bottom PCC floor of the pit should be minimum 30cms below the bottom surface of sluice valve flange to provide sufficient working space), bottom floor of the pit be constructed in PCC (1:4:8) type D2 using 15cms thick with 20mm stone aggregate for foundation, brick wall with sub class 'B' bricks built in CM 1:6, inner and exposed surfaces and bottom floor of the pit should be plastered in cement mortar (1:4) 15mm thick, PCC 1:2:4 type B1 using 20mm graded stone aggregate for coping. The sluice valve and other fittings should be housed in center of the pit. The vertices of the pit should in right angle and chamfered. The top cover of the pit will be made out of MS sheet 3mm thick with angle iron frame made out of MS angle 50mmx50mmx6mm with galvanized steel hinges two Nos. and locking arrangements duly painted with two coats of water resistant synthetic enameled paint over one coat of red oxide including necessary excavation and earth work in any type of soil complete all as specified and directed by Engr-in-Charge
All as per ser item No. 79 above but of valve pit of internal dimension 450mm x 450mm x 600mm ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Submersible Pump Controller in sheet encloures fully Automatic Star-Delta Starter, with short circuit protection IP-54, conforming to IS/IEC-60947-4-1, with inbuilt metering & MCB, 3 Phase, 415 Volt, AC-3 duty, 50 Hz, Motor Output Capacity upto 15 HP / 10 KW and relay range 12-18 Amps and making incoming & outgoing electric connection including dismantling of old UNSV one from site complete ; Complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 81 above but of motor outpur capacity 30 HP / 22.5 KW and relay range 22-32 Amps ; Complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 81 above but of motor outpur capacity 45 HP/33 KW and relay range 28-40 Amps ; Complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 81 above but of motor outpur capacity 50 HP/37.5 KW and relay range 34-50 Amps ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Direct-on-Line (DOL) starter in sheet encloures, 3 Phase, 415 Volt, AC-3 duty, 50 Hz, Motor Output Capacity upto 5 HP /3.5 KW and relay range 9-14 Amps and making incoming & outgoing electric connection including dismantling of old UNSV one from site complete ; Complete all as specified and directed by Engineer-in-charge.
Material and Labour for cement concrete 1:2:4 type C-2 (using 40mm graded stone aggregate) for copinng of poles, mass concrete including necessary form work ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Wood core nylon brush 36” long for sweeper (pool cleaner) ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing suction sweeper pipe as per sample, of superior quality, 50mm dia ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing digital Ammeter, flush mounting, of size 96x96mm, 0-500A, AC 3 phase, class-1 including making electrical connection and dismantling of old UNSV one from site ; Complete all as specified and directed by Engineer-in-charge.
Supply and Fixing digital voltmeter, flush mounting, of size 96x96mm 0-500 volt, AC 3 phase, class-1 including making electrical connection and dismantling of old UNSV one from site ; Complete all as specified and directed by Engineer-in-charge.
Material and labour for development of bore well with high capacity air compresser of suitable sizefor running duration not less than 4 hours till the water becomes sand and silt free including removal of liquid mud, sand, silt etc up to a distance of 50 metre and deposited where directed, ; Complete all as specified and directed by Engineer-in-charge. NOTE: (a) Air compressor, fuel, manpower, any other equipment of suitable capacity for the development of tube well shall be arranged by the contractor under his own arrangements and nothing extra shall be payable to the contractor on this account. (b) The discharge shall be measured by providing orifice system of 'V' notch fixed to steel tanks of adequate capacity. (c) A proper record and log sheet for running of compressor shall be prepared and signed by the contractor & Engineer-in-Charge, countersigned by GE and shall form part of final bill.
Material and Labour Surface excavation n.exc 30 cm deep and averaging 15cm deep in soft/loose soil including clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth and getting out rubbish upto a distance of 50 metres outside the periphery of the area under clearance including levelling of the area complete including necessary glyphosate 41% SL Glykol Herbicide required to remove vegatationa in the entire pump house complex within the fencing ; Complete all as specified and directed by Engineer-in-charge. NOTE: (a) T&P required for this job to be brought by the contractor.
Supply and fixing glow sign board of size 750mm x 1000mm x 100mm fabricated made out from GI sheet of size not less than 2.0mm thick for all four sides and back side of the board and for front side using acrylic sheet with white colour vinyl film with computerised cut/printed letters/pictures as required size/shape as approved by Engr-in-Charge including provn of 04 Nos. LED tube light fittings 2'x10 Watts fixed inside the board complete all prewired with 3 core flexible copper conductor cable and including welding griding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary nuts and bolts on inside wall of the MES installation/ pump house building with angle iron of size 40mm x 40mm x 6mm with nut/bolts or grounting on wall complete and writting letters of installation details, flow diagrams, water distribution area, MES logo as per direction/sample etc., ; Complete all as specified and directed by Engineer-in-charge. NOTE: Cost of service cables of suitable size required to connect the glow sign board from switch board and testing will be deemed to be included in the quoted rate.
Material and Labour for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6.0 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) normal with top edge of plate not less than 1.5m below normal ground level, earth plate connected to GI strip earth lead of size 25 x 4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR part I connected to earth test point all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 meter long for earth wire including PCC (1:2:4) pit with precast RCC (1:2:4) type B -1 cover, 40mm thick reinforced with 6mm dia MS bars @ 100 mm both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with funnel, wire, common salt, charcoal filling, necessary excavation and earth work in any type of soil ; Complete all as specified and directed by Engineer-in-charge.
HARPAL ENGINEERS AND BUILDERS (BID ID -3142569)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .