Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC 180 10 STREET NO 10 HARPAL NAGAR NEAR TRIVENI MANDIR BHATTI ROAD BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹17.9 L+₹2.7 L (18.0%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
₹15.2 L
EMD Value
₹30,386
Closing Date
9 Oct 2023, 1:00 pmClosed
Xen,Kandi Canal Stage2 Division,hoshiarpur
Xen,Kandi Canal Stage2 Division,hoshiarpur
Restoration of damaged direct outlet at RD.119.200 km right side of Kandi canal stage -2
2023_WR_110156_1
57
Open Tender
Civil Works - Canal
Item Rate
60 days
Hoshiarpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
₹30,386
Yes
18 Jun 2024
30 Sept 2023
9 Oct 2023
30 Sept 2023
9 Oct 2023
30 Sept 2023
Amount
(2) Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Earth work upto 1.5 m. Depth for
All classes of soil except rocky
Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing , cost of nut bolts & rubber insertion all carriages complete.
C.I Single air valve screwed (Size 50mm)
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
(a) Size 0.6 m. x 0.6 m.
(b) Size 0.9 m. x 0.9 m.
Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge
Capacity of Air compressor 300 cfm at 250 PSI
BRICK WORK First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
PLASTERING & POINTING 12.5 mm thick cement plaster 1:4
Cement rendering on plaster 1mm thick
CONCRETE Cement concrete 1:2:4mixing by mechanical means using concrete mixer volumetric type
STEEL AND IRON WORKCold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
providing laying , fixing & jointing of UPVC socketed type pipe as per ISI-4985 (ISI marked with the prior approval of engg.in.charg. )along the trenches & laying the same in trench to correct alignment & gradient,cutting ,jointing& testing complete as per specification pipe 2.5 kg /sqcm 160mm dia
providing laying , fixing & jointing of UPVC socketed type pipe as per ISI-4985 (ISI marked with the prior approval of engg.in.charg.)along the trenches & laying the same in trench to correct alignment & gradient,cutting ,jointing& testing complete as per specification pipe 2.5 kg /sqcm 180mm
providing laying , fixing & jointing of UPVC socketed typepipe as per ISI-4985 (ISI marked with the prior approval of engg.in.charg. )along the trenches & laying the same in trench to correct alignment & gradient,cutting ,jointing& testing complete as per specification pipe 2.5 kg /sqcm 200mm
providing laying , fixing & jointing of UPVC socketed type pipe as per ISI-4985 (ISI marked with the prior approval of engg.in.charg. )along the trenches & laying the same in trench to correct alignment & gradient,cutting ,jointing& testing complete as per specification pipe 2.5 kg /sqcm 250mm
providing laying , fixing & jointing of UPVC socketed type pipe as per ISI-4985 (ISI marked with the prior approval of engg.in.charg. )along the trenches & laying the same in trench to correct alignment & gradient,cutting ,jointing& testing complete as per specification pipe 2.5 kg /sqcm 315mm
providing &fixing ISI marked Alfa valve 160mm
Providing & fixing ISI Marked Alfa valve 180mm
Providing & fixing ISI Marked Alfa valve 200mm
Providing & fixing upvc Bend (6kg/sqm pressure )conforming to IS codes with latest amendment if any at sint of work including loading,unloading if any complete in all respects as per design & P.W.D specification & instruction of engg.in charge. 160mm
Providing & fixing upvc Bend (6kg/sqm pressure ) conforming to IS codes with latest amendment if any at sint of work including loading,unloading if any complete in all respects as per design & P.W.D specification & instruction of engg.in charge. 180mm
Providing & fixing upvc Bend (6kg/sqm pressure ) conforming to IS codes with latest amendment if any at sint of work including loading,unloading if any complete in all respects as per design & P.W.D specification & instruction of engg.in charge. 200mm
any other item
Deepak Kumar Beetan
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .