Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.9 L+₹43,930 (2.52%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹18.7 L+₹1.2 L (7.09%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹19.8 L+₹2.4 L (13.7%)Rejected-Finance 018 GROUND FLOOR LEKHRAJ ENCLAVE LEKHRAJ PANNA SECTOR 2 VIKAS NAGAR LUCKNOW UTTAR PRADESH 226022 | LUCKNOW | UTTAR PRADESH | 226022 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹21.8 L+₹4.3 L (24.6%)Rejected-Finance 86 MAHEWA EAST NAINI PRAYAGRAJ U P | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
9 Sept 2021, 6:00 pmClosed
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
Repair/ maint of manholes, sewage lines including cleaning of sewage line of Zone A, B, C at old Cantt Allahabad.
2021_MES_469076_1
8497/E8
Open Tender
Civil Works
Item Rate
270 days
Allahabad
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹50,000
Yes
20 Nov 2021
18 Aug 2021
11 Sept 2021
18 Aug 2021
9 Sept 2021
2 Sept 2021
18 Aug 2021 - 25 Aug 2021
Amount
Cleaning of choked sewer line of 100mm dia depth upto 1.5m manually or through mechanical appliances and making sewer line functional, complete including working under foul conditions and depositing the sludge rubbish etc. off the premises at an isolated place not exceeding 1 km distance, complete all as specified and directed. Note: Manholes connected with affected sewer line shall be measured separately.
Cleaning of choked sewer line of 100mm dia depth upto 1.5m through diesel running vehilce mounting hydraulic operated high pressure suction-cum-jetting sewer cleaning machine fitted with pump having suction capacity and water jetting tank including skilled operator, supervisor/ enginer and two safaiwalas etc, including manholes of depth not exceeding 1.5 m, including working under foul conditions and depositing the sludge rubbish etc. off the premises at an isolated place not exceeding 1 km distance, complete all as specified and directed.
Cleaning of choked sewer line of 150mm dia depth upto 1.5m manually or through mechanical appliances and making sewer line functional, complete including working under foul conditions and depositing the sludge rubbish etc. off the premises at an isolated place not exceeding 1 km distance, complete all as specified and directed. Note: Manholes connected with affected sewer line shall be measured separately.
Cleaning of choked sewer line of 150mm dia depth upto 1.5m through diesel running vehilce mounting hydraulic operated high pressure suction-cum-jetting sewer cleaning machine fitted with pump having suction capacity and water jetting tank including skilled operator, supervisor/ enginer and two safaiwalas etc, including manholes of depth not exceeding 1.5 m, including working under foul conditions and depositing the sludge rubbish etc. off the premises at an isolated place not exceeding 1 km distance, complete all as specified and directed.
Cleaning of choked sewer line of 150mm dia depth exc 1.5m but n. exc. 3 m, through diesel running vehilce mounting hydraulic operated high pressure suction-cum-jetting sewer cleaning machine fitted with pump having suction capacity and water jetting tank including skilled operator, supervisor/ enginer and two safaiwalas etc, including working under foul conditions and depositing the sludge rubbish etc. off the premises at an isolated place not exceeding 1 km distance, complete all as specified and directed.
Cleaning of choked sewer line of 200mm dia depth exc 1.5m but n. exc. 3 m, through diesel running vehilce mounting hydraulic operated high pressure suction-cum-jetting sewer cleaning machine fitted with pump having suction capacity and water jetting tank including skilled operator, supervisor/ enginer and two safaiwalas etc, including working under foul conditions and depositing the sludge rubbish etc. off the premises at an isolated place not exceeding 1 km distance, complete all as specified and directed.
Cleaning of choked sewer line of 200mm dia depth exc 3.0m but n. exc. 4.5 m, through diesel running vehilce mounting hydraulic operated high pressure suction-cum-jetting sewer cleaning machine fitted with pump having suction capacity and water jetting tank including skilled operator, supervisor/ enginer and two safaiwalas etc, including working under foul conditions and depositing the sludge rubbish etc. off the premises at an isolated place not exceeding 1 km distance, complete all as specified and directed.
Cleaning of choked sewer line of 300mm dia depth exc 1.5m but n. exc. 3 m, through diesel running vehilce mounting hydraulic operated high pressure suction-cum-jetting sewer cleaning machine fitted with pump having suction capacity and water jetting tank including skilled operator, supervisor/ enginer and two safaiwalas etc, including working under foul conditions and depositing the sludge rubbish etc. off the premises at an isolated place not exceeding 1 km distance, complete all as specified and directed.
Cleaning of choked sewer line of 300mm dia depth exc 3.0m but n. exc. 4.5 m, through diesel running vehilce mounting hydraulic operated high pressure suction-cum-jetting sewer cleaning machine fitted with pump having suction capacity and water jetting tank including skilled operator, supervisor/ enginer and two safaiwalas etc, including working under foul conditions and depositing the sludge rubbish etc. off the premises at an isolated place not exceeding 1 km distance, complete all as specified and directed.
Cleaning of choked sewer line of 300mm dia depth exc 4.5m but n. exc. 6.0 m, through diesel running vehilce mounting hydraulic operated high pressure suction-cum-jetting sewer cleaning machine fitted with pump having suction capacity and water jetting tank including skilled operator, supervisor/ enginer and two safaiwalas etc, including working under foul conditions and depositing the sludge rubbish etc. off the premises at an isolated place not exceeding 1 km distance, complete all as specified and directed.
Cleaning of blocked / chocked manholes including removal of sludge / dirt etc water semi solid materials including other materials from manholes of depth of manholes not exceeding 1.5m depth and removing rubbish & deposited outside building premises complete all as specified and directed. Note: Sludge will be disposed off the area out of premises of MOD and covered the same by bleaching powder @1.5 kg/sqm over surface of sludge.
Cleaning of blocked / chocked manholes including removal of sludge / dirt etc water semi solid materials including other materials from manholes of depth of manholes exceeding 1.5m but not exceeding 3m depth and removing rubbish & deposited outside building premises complete all as specified and directed. Note: Sludge will be disposed off the area out of premises of MOD and covered the same by bleaching powder @1.5 kg/sqm over surface of sludge.
Cleaning of chocked Water closet/ Floor trap/ Gully trap etc mnually by taking off sludge waste, night soil and silted soil from the existing pipe, by taking out accumulated garbage, silt, mud etc and removing the same at a distance not exceeding 50 m (where directed), washing and well flushing of the floor trap/WC/gully trap with water, complete all as specfied and directed.
Demolition and breaking up salt glazed stoneware drain pipe of any internal dia, set in cement mortar, complete all as specfied and directed.
Salt glazed stoneware drain pipe 200mm bore, grade A laid in trenches and jointed in CM 1:1, complete all as specfied and directed.
Salt glazed stoneware drain pipe 150 mm bore, grade A laid in trenches and jointed in CM 1:1, complete all as specfied and directed.
Cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm crushed stone aggregate for the 200 mm internal dia of pipe complete all as specified & directed.
Cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm crushed stone aggregate for the 150 mm internal dia of pipe complete all as specified & directed.
UPVC (SWR) pipes of 110mm internal dia, single socketed in any length with rubber ring joints fixed to walls or laid in floors, with MS clips or clamps, fixed in repair, complete all as specified & directed.
UPVC (SWR) pipes of 75mm internal dia, single socketed in any length with rubber ring joints fixed to walls or laid in floors, with MS clips or clamps, fixed in repair, complete all as specified & directed.
UPVC(SWR) bends in any radius, 110mm bore, fixed in repair, complete all as specified and directed.
UPVC(SWR) bends in any radius, 110mm bore, provided with access door, fixed in repair, complete all as specified and directed.
UPVC(SWR) bends in any radius, 75mm bore, fixed in repair, complete all as specified and directed.
UPVC(SWR) bends in any radius, 75mm bore, provided with access door, fixed in repair, complete all as specified and directed.
Cast Iron 75mm bore floor trap, plain with grating including jointing with solvent cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) in repair, complete all as specified and directed.
Material & Labour 100 mm bore cast iron pipe sand cast soil waste and vent pipes in any length with or without ears, joint with cement joints, fixed in walls, complete all as specified & directed.
Cast Iron branch piece single (equal and unequal) for 100 mm bore pipe, complete all as specified & directed.
Cast Iron plain bend 100mm bore, fixed in reapir, complete all as specified & directed.
Excavation in trenches not exceeding 1.5m deep & not exceeding 1.5m wide or area not exceeding 10 Sqm on plan& depth not exceeding 1.5 m in soft/loose soil and getting out for foundation, trenches etc complete all as specified & directed.
Returning, filling in soils, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removing surplus excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
Demolition of Cement Concrete (reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed.
Precast cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in drain cover, cover slab (for manholes), chajjas, water troughs, mangers, shelves and similar work including necessary form work and set in CM 1:4 complete all as specified & directed. Note: (a) The quoted rate is deemed to include the use of forms, moulds or machine moulds and setting the blocks, slabs, etc. complete including raking back the joints of the internal faces (at least 10 mm) for pointing as the work proceeds or finishing with neat flush joints. (b) Reinforcement shall be measured and paid separately.
Mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified & directed.
Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facing, dresssed stonework and precast concrete articles complete all as specified and directed.
Brickwork with subclass ‘B’ old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:4, complete all as specified and directed.
Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as in wall, drain, etc, finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces as in wall, drain, etc, finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Demolition of Cement Concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed.
PCC 1:5:10 type E-2 using 40 mm graded crushed stone aggregate as in filling up sunken floor or mass concrete or similar wrok complete all as specified & directed.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe), including provision of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe, CI trap 100mm bore of pipe, fixed in repair, complete all as specified and directed.
Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), fixing seat cover including connection to drain (or outgoing pipe) and to flushing pipe and anti syphonage pipe etc with aluminium hin ging device, fixed in repair, complete all as specified and directed. Note: Plastic seat cover shall be measured separately as supply only as considered under respective items.
Dismantling floor, hearth or wall tiling including cement mortar bedding, removing rubbish off the premises complete all as specified and directed.
Joint free Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm each (Min size 400mm x 400mm), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Raj Contruction
ARADHYA ENTERPRISES
SK ENTERPRISES
MOHAMMAD RIZWAN CONTRACTOR
AMARDEEP ENTERPRISES
M/S A P CONSTRUCTION
ANKIT SHIP REPAIRERS AND SUPPLIERS
JAI MAA VINHYAVASANI CONSTRACTION CO
DINESH ELECTRICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .