Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 CrAccepted-AOC 41 21 A KMC TOWERS C2 C2 SCHEME ROAD THENI 625531 | THENI | TAMIL NADU | 625531 | ₹10.1 Cr | L1 | Accepted-AOC Admitted |
| 2 | L2₹10.9 CrRejected-AOC NO 59 SOUTH STREET NAGARAPPADI POST SRIMUSHNAM TALUK CUDDALORE 608703 | SRIMUSHNAM | CUDDALORE | TAMIL NADU | 608703 | ₹10.9 Cr | L2 | Rejected-AOC Not Admitted |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical EMD Not Furnished |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical EMD Not Furnished |
Tender Value
Refer Docs
EMD Value
₹12.4 L
Closing Date
31 Oct 2023, 3:00 pmClosed
Executive Officer
17,patti Street, srimushnam, Srimushnam (TK) Cuddalore (DT)
Improvement of existing water supply system in Srimushnam Town Panchayat
2023_DTP_375371_1
A1/74/2023
Open Tender
Water Supply/Equipments/Meter/Drilling/Boring
365 days
Srimushnam Town panchayat
Improvement of existing water supply system in Srimushnam Town Panchayat
3 documents required · 3 mandatory
₹0
₹12.4 L
Yes
21 Dec 2023
3 Oct 2023
31 Oct 2023
3 Oct 2023
31 Oct 2023
3 Oct 2023
3 Oct 2023 - 31 Oct 2023
Amount
Borewell - 150 mtr And 180 mtr Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the Department Officers) including construction of mud pit. - Upto 60m depth ending below ground level
Borewell - 150 mtr And 180 mtr Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the Department Officers) including construction of mud pit. - From 60m and upto 90m depth ending below ground level
Borewell - 150 mtr And 180 mtr Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the Department Officers) including construction of mud pit. - From 90m and upto 120m depth ending below ground level
From 120m and upto 150m depth ending below ground level
From150m and upto 180m depth ending below ground level
Reaming from 140/150 mm dia pilot bore to 300 mm dia bore as directed by the Department officers - Upto 60m depth ending below ground level
Borewell - 150 mtr And 180 mtr Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the Department Officers) including construction of mud pit. - From 60m and upto 90m depth ending below ground level
Borewell - 150 mtr And 180 mtr Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the Department Officers) including construction of mud pit. - From 90m and upto 120m depth ending below ground level
Borewell - 150 mtr And 180 mtr Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the Department Officers) including construction of mud pit. - From 120m and upto 150m depth ending below ground level
Borewell - 150 mtr And 180 mtr Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the Department Officers) including construction of mud pit. - From150m and upto 180m depth ending below ground level
Supply and delivery of unplasticised PVC casing pipes of the following diametre in 3 metres length with screwed and scoket ends and centering guides for every 15m length of pipes as per IS 12812 / 92 and DN 4925 and as amended from time to time to suit - Supply of 150mm Nominal dia (6") Deep borewell PVC plain casing pipe (CM)
Supply and delivery of 150 mm Nominal dia ( 6") Deep borewell Ribbed screen PVC Casing pipe (RDS) with suitable 1.0mm horizandal slot with having open areas 12 % minimum with wall thckness 13mm to 14.30 mm at site of work
Supply and delivery of Bore cap using M.S. Flat of size 1 cm x 3 mm and M.S. sheet on top with bolting arrangements for securing the cap in position (Bore caps with M.S. Couplings need not be made) - Supply of 150 mm Nominal dia ( 6") dia PVC deep well bottom cap at site of work
Labour Charges for inserting PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with Cement paste etc.,complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineers -150 mm OD PVC casings Pipes assembly
Charges for developing the Borewell with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor as directed by Officers and conducting yield test by 'V' notch method.
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers - Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with smallsize boulders and hard gravelly soil.SS20B For Foundation - First depth of 0 to 2 m - FOR HSC, HRE
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers - Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with smallsize boulders and hard gravelly soil.SS20B For Foundation - Second depth of 1m - FOR SDR
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers - Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with smallsize boulders and hard gravelly soil.SS20B For Foundation -2nd depth of 2m to 3m - FOR DMR not requiring blasting
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers - Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with smallsize boulders and hard gravelly soil.SS20B For Foundation - For Di Pipes - 100 MM Dia DI K7
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers - Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with smallsize boulders and hard gravelly soil.SS20B For Foundation - For Di Pipes - 150 MM Dia DI K7
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers - Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with smallsize boulders and hard gravelly soil.SS20B For Foundation - For HDPE - 90 mm HDPE PE100PN6
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers - Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with smallsize boulders and hard gravelly soil.SS20B For Foundation - For HDPE - 110 mm HDPE PE100PN6
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers - Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with smallsize boulders and hard gravelly soil.SS20B For Foundation - For HDPE - 125 mm HDPE PE100PN6
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers - Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with smallsize boulders and hard gravelly soil.SS20B For Foundation - For HDPE - 140 mm HDPE PE100PN6
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers - Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with smallsize boulders and hard gravelly soil.SS20B For Foundation - For HDPE - 160 mm HDPE PE100PN6
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers - Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with smallsize boulders and hard gravelly soil.SS20B For Foundation - For HDPE - 180 mm HDPE PE100PN6
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers - Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with smallsize boulders and hard gravelly soil.SS20B For Foundation - For HDPE - 200 mm HDPE PE100PN6
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers - Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with smallsize boulders and hard gravelly soil.SS20B For Foundation - For HDPE - 225 mm HDPE PE100PN6
Supply and Delivery DUCTILE IRON PIPES FOR CLASS K7 AS PER IS 8329/2000 - 100mm diameter
Supply and Delivery DUCTILE IRON PIPES FOR CLASS K7 AS PER IS 8329/2000 -150mm diameter
Supply and Delivery DUCTILE IRON SPECIALS AS PER IS 9523/2000- 100mm - 90 Deg D/S Bend
Supply and Delivery DUCTILE IRON SPECIALS AS PER IS 9523/2000- 100mm - 45 Deg D/S Bend
Supply and Delivery DUCTILE IRON SPECIALS AS PER IS 9523/2000- 100mm - 22 1/2 Deg D/S Bend
Supply and Delivery DUCTILE IRON SPECIALS AS PER IS 9523/2000- 150mm - 90 Deg D/S Bend
Supply and Delivery DUCTILE IRON SPECIALS AS PER IS 9523/2000- 150mm - 45 Deg D/S Bend
Supply and Delivery DUCTILE IRON SPECIALS AS PER IS 9523/2000- 150mm - 22 1/2 Deg D/S Bend
Supply, Delivery and fixing of DI D/F Gate valves (Soft Seated) resilient seated soft sealing gate valves (sluice valves) with body bonnet of ductile cast iron of grade GGG40 or equivalent grade, wedge fully rubber lined with EPDM, replaceable spindle nut, without gland packing and with 3 O-Ring protection on the shaft and seals of NBR and the valves should be of vaccum tight and 100% leak proof with face to face dimentions as CI D/F SLUICE VALVE WITH CAP/ WHEEL AS PER IS 14846/2000 PN 1.0 WITH ISI MARKING All the valves should be with electrostatic powder coating both inside and outside with pocket less straight thro' body passage, inside and outside color Blue including Flange/socket and Flange/spicot tail pieces, etc., loading,unloading, Transportation charges and stacking etc. complete as per specifications. All the valves are to be compatible for burried application with pressure rating PN 10/16 - For DI 100mm dia Valve
Supply, Delivery and fixing of DI D/F Gate valves (Soft Seated) resilient seated soft sealing gate valves (sluice valves) with body bonnet of ductile cast iron of grade GGG40 or equivalent grade, wedge fully rubber lined with EPDM, replaceable spindle nut, without gland packing and with 3 O-Ring protection on the shaft and seals of NBR and the valves should be of vaccum tight and 100% leak proof with face to face dimentions as CI D/F SLUICE VALVE WITH CAP/ WHEEL AS PER IS 14846/2000 PN 1.0 WITH ISI MARKING All the valves should be with electrostatic powder coating both inside and outside with pocket less straight thro' body passage, inside and outside color Blue including Flange/socket and Flange/spicot tail pieces, etc., loading,unloading, Transportation charges and stacking etc. complete as per specifications. All the valves are to be compatible for burried application with pressure rating PN 10/16 - 150mm diameter
Manufacture, Supply and Delivery of Tamper proof C.I. DOUBLE AIR VALVE AS PER ISI 14845/2000 with pressure range from PN 1.0 to 2.5 with body and cover made of Ductile Iron of Grade GGG 40 or equivalent grade conforming to IS 1865 with Food Grade Epoxy Powder coating(EP-P) inside and for outside of colour blue RAL 5005. All internal parts such as float, shell etc., cover bolts, made of Austenitic alloy steel of SS AISI 304/316. The float shall be made of Polytetrafluroethylene/ Austenitic alloy steel of AISI 304/316. Gaskets and seals of EPDM / Neoprene rubber and as amended from time to time and suitable for water supply main including loading freight, transit, unloading and stacking them at site etc. complete - 50 mm Air Valve
Supply and delivery of DI D/F specials of conforming to IS 9523/2000 specifications at site of work including all taxes, duties, loading, transportation, unloading, insurance etc., complete and as directed by Engineer incharge. - 150 mm Flanged Socket Tail Piece
Supply and delivery of DI D/F specials of conforming to IS 9523/2000 specifications at site of work including all taxes, duties, loading, transportation, unloading, insurance etc., complete and as directed by Engineer incharge. - 150 mm Flanged Spigot Tail Piece
Supply and delivery of DI D/F specials of conforming to IS 9523/2000 specifications at site of work including all taxes, duties, loading, transportation, unloading, insurance etc., complete and as directed by Engineer incharge. - 150 mm DUCKFOOT BEND
Supply and delivery of DI D/F specials of conforming to IS 9523/2000 specifications at site of work including all taxes, duties, loading, transportation, unloading, insurance etc., complete and as directed by Engineer incharge. - 150x 100 mm DI D/S Tee with Flange
Supply and delivery of DI D/F specials of conforming to IS 9523/2000 specifications at site of work including all taxes, duties, loading, transportation, unloading, insurance etc., complete and as directed by Engineer incharge. - 100x 100 mm DI D/S Tee with Flange
Supply and delivery of DI D/F specials of conforming to IS 9523/2000 specifications at site of work including all taxes, duties, loading, transportation, unloading, insurance etc., complete and as directed by Engineer incharge. - 150x 150 mm DI D/S Tee with Flange
Supply and delivery of DI D/F specials of conforming to IS 9523/2000 specifications at site of work including all taxes, duties, loading, transportation, unloading, insurance etc., complete and as directed by Engineer incharge. - 100 mm Flanged Socket Tail Piece
Supply and delivery of DI D/F specials of conforming to IS 9523/2000 specifications at site of work including all taxes, duties, loading, transportation, unloading, insurance etc., complete and as directed by Engineer incharge. - 100 mm Flanged Spigot Tail Piece
Supply and delivery of DI D/F specials of conforming to IS 9523/2000 specifications at site of work including all taxes, duties, loading, transportation, unloading, insurance etc., complete and as directed by Engineer incharge. - 100mm dia DI 900 Duck foot flanged bend For 3.00 OHT
Supply and delivery of DI D/F specials of conforming to IS 9523/2000 specifications at site of work including all taxes, duties, loading, transportation, unloading, insurance etc., complete and as directed by Engineer incharge. - 100mm dia DI 900 D/F flanged bend For 3.00 LL OHT
Supply and delivery of DI D/F specials of conforming to IS 9523/2000 specifications at site of work including all taxes, duties, loading, transportation, unloading, insurance etc., complete and as directed by Engineer incharge. - 100mm dia DI flanged socket For 3.00 LL OHT
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow.The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”.Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished - 100mm diameter
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow.The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”.Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished - 150mm diameter
Lowering of DI pipes and specials carefully into the trench and laying to proper grade and alignment including labour charges, incidental and operational charges etc complete as per standard specifications and as directed by the Departmental Engineer - 100mm diameter
Lowering of DI pipes and specials carefully into the trench and laying to proper grade and alignment including labour charges, incidental and operational charges etc complete as per standard specifications and as directed by the Departmental Engineer - 150mm diameter
Cutting of CI and DI pipes and specials true to axis and filing smoothly and finishing the ends complete, with / without water in the pipe including labour charges, incidental and operational charges etc complete as per standard specifications and as directed by Departmental Engineer - 100mm diameter
Cutting of CI and DI pipes and specials true to axis and filing smoothly and finishing the ends complete, with / without water in the pipe including labour charges, incidental and operational charges etc complete as per standard specifications and as directed by Departmental Engineer - 150mm diameter
Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials) - 100mm diameter
Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials) - 150mm diameter
Testing of M.S. / C.I. / D.I / P.V.C. /D.W,C, pipes with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc.,complete for the following diameters of Di Pipes - 100mm diameter
Testing of M.S. / C.I. / D.I / P.V.C. /D.W,C, pipes with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc.,complete for the following diameters of Di Pipes - 150mm diameter
Testing of M.S. / C.I. / D.I / P.V.C. /D.W,C, pipes with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc.,complete for the following diameters of HDPE Pipes - 90 mm HDPE PE100PN6
Testing of M.S. / C.I. / D.I / P.V.C. /D.W,C, pipes with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc.,complete for the following diameters of HDPE Pipes - 110 mm HDPE PE100PN6
Testing of M.S. / C.I. / D.I / P.V.C. /D.W,C, pipes with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc.,complete for the following diameters of HDPE Pipes - 125 mm HDPE PE100PN6
Testing of M.S. / C.I. / D.I / P.V.C. /D.W,C, pipes with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc.,complete for the following diameters of HDPE Pipes - 140 mm HDPE PE100PN6
Testing of M.S. / C.I. / D.I / P.V.C. /D.W,C, pipes with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc.,complete for the following diameters of HDPE Pipes - 160 mm HDPE PE100PN6
Testing of M.S. / C.I. / D.I / P.V.C. /D.W,C, pipes with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc.,complete for the following diameters of HDPE Pipes - 180 mm HDPE PE100PN6
Testing of M.S. / C.I. / D.I / P.V.C. /D.W,C, pipes with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc.,complete for the following diameters of HDPE Pipes - 200 mm HDPE PE100PN6
Testing of M.S. / C.I. / D.I / P.V.C. /D.W,C, pipes with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc.,complete for the following diameters of HDPE Pipes - 225 mm HDPE PE100PN6
Testing of M.S. / C.I. / D.I / P.V.C. /D.W,C, pipes with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc.,complete for the following diameters of HDPE Pipes - 250 mm HDPE PE100PN6
Barricading work (Where the lines are in narrow width of municipality area, busy streets like Market, Bus-stand and in the Highways etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia. and 1.80m height) vertical with horizontal poles in two rows, painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including supplying, delivery and fixing of GI sheet (0.90m x 0.8mm thick) in the horizontal poles and fixing 75mm dia. reflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc., complete and as directed by Departmental Engineers.
"Construction of Brick work valve Chamber with M30 Grade concrete . The rate should include earth work excavation in various soils met with at the site of work, refilling the pit after the construction of the pit, PCC M10 for Blinding Concrete, Brick work in CM 1:5 and plastering with CM 1:5 - 12mm thick, cost of steel reinforcement fabrication charges, Cover slab with manhole cover etc., and fixing the valves in position inside the pit including laying, jointing of valves, HDPE pipes and specials including the cost of jointing materials such as bolts and nuts RI sheets washers etc., complete and as directed by the Departmental Engineer.Valve Chamber size (inner) - 1.00mx1.00mx1.50m
Plain Cement concrete 1:4:8 (one cement four sand and eight aggregates) using 40mm HBGS for levelling course for foundation including the cost of mixing concrete, ramming, curing etc., complete as directed by Departmental Engineer.
Plain Cement Concrete 1:2:4 (one cement, two fine aggregates and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification
Supplying and filling in foundation and basement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Reinforced Cement Concrete with M25 Design Mix for the following members excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges but including the cost of all materials, mixing, placing in position, lifting, vibrating, finishing & curing, etc. complete.and as directed by Department Engineer - For Upto 1.50 m Below GL
Reinforced Cement Concrete with M25 Design Mix for the following members excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges but including the cost of all materials, mixing, placing in position, lifting, vibrating, finishing & curing, etc. complete.and as directed by Department Engineer - For Upto 4.50 m Above GL
Reinforced Cement Concrete with M25 Design Mix for the following members excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges but including the cost of all materials, mixing, placing in position, lifting, vibrating, finishing & curing, etc. complete.and as directed by Department Engineer - For Above 4.50m to 7.32m ht., from G.L
Reinforced Cement Concrete with M25 Design Mix for the following members excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges but including the cost of all materials, mixing, placing in position, lifting, vibrating, finishing & curing, etc. complete.and as directed by Department Engineer - For Above 7.32m to 10.98m ht., from G.L
Reinforced Cement Concrete with M25 Design Mix for the following members excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges but including the cost of all materials, mixing, placing in position, lifting, vibrating, finishing & curing, etc. complete.and as directed by Department Engineer - For Above 10.98m to 14.64m ht., from G.L
Reinforced Cement Concrete with M30 Design Mix for the following members excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges but including the cost of all materials, mixing, placing in position, lifting, vibrating, finishing & curing, etc. complete.and as directed by Department Engineer.Beyond 1.50 m & upto 4.50 m below GL For 2.00 LL Sump 62.99 cum For 0.60 LL OHT 11.13 cum
Reinforced Cement Concrete with M30 Design Mix for the following members excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges but including the cost of all materials, mixing, placing in position, lifting, vibrating, finishing & curing, etc. complete.and as directed by Department Engineer.Upto 1.50 m Below GL For 2.00 LL Sump 7.87 Cum For 0.60 LL OHT 3.50 cum
Reinforced Cement Concrete with M30 Design Mix for the following members excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges but including the cost of all materials, mixing, placing in position, lifting, vibrating, finishing & curing, etc. complete.and as directed by Department Engineer.Upto 4.50 m Above GL For 2.00 LL Sump 23.62 Cum For 0.60 LL OHT 3.79 cum
Reinforced Cement Concrete with M30 Design Mix for the following members excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges but including the cost of all materials, mixing, placing in position, lifting, vibrating, finishing & curing, etc. complete.and as directed by Department Engineer.Above 4.50m to 7.32m ht., from G.L For 0.60 LL OHT 2.97 cum
Reinforced Cement Concrete with M30 Design Mix for the following members excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges but including the cost of all materials, mixing, placing in position, lifting, vibrating, finishing & curing, etc. complete.and as directed by Department Engineer.Above 7.32m to 10.98m ht., from G.L For 0.60 LL OHT 3.38 cum
Reinforced Cement Concrete with M30 Design Mix for the following members excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges but including the cost of all materials, mixing, placing in position, lifting, vibrating, finishing & curing, etc. complete.and as directed by Department Engineer.Above 10.98m to 14.64m ht., from G.L For 0.60 LL OHT 17.62 cum
Reinforced Cement Concrete with M30 Design Mix for the following members excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges but including the cost of all materials, mixing, placing in position, lifting, vibrating, finishing & curing, etc. complete.and as directed by Department Engineer.Above 14.64m ht., to 18.30m ht., For 0.60 LL OHT 8.59 cum For 3.00 LL OHT 67.00 Cum
Reinforced Cement Concrete with M30 Design Mix for the following members excluding the cost of reinforcement and fabricating, centering, shuttering and strutting charges but including the cost of all materials, mixing, placing in position, lifting, vibrating, finishing & curing, etc. complete.and as directed by Department Engineer.Above 18.30 m to 21.96m ht., from G.L For 3.00 LL OHT - 26.00 Cu,
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Plane Surface - For 0.00 to 3.30 M
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Plane Surface - For 3.30 to 4.30 M
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Plane Surface - For 5.30 to 6.30 M
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Plane Surface - For 6.30 to 7.30 M
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Plane Surface - For 7.30 to 8.30 M
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Plane Surface - For 9.30 to 10.30 M
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Plane Surface - 11.30m to 12.30m ht above GL
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Plane Surface - 12.30m to 13.30m ht above GL
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Plane Surface - 15.30m to 16.30m ht above GL
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Curved Surface - 0.00 to 3.30 M
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Curved Surface - 3.30 to 4.30 M
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Curved Surface - 16.30 to 17.30 M
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Curved Surface - 17.30 to 18.30 M
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Curved Surface - 18.30 to 19.30 M
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 On Curved Surface - 19.30 to 20.30 M
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Circular Column 0.00 to 3.30 M
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Circular Column 3.30m to 4.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Circular Column 4.30m to 5.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Circular Column 5.30m to 6.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Circular Column 6.30m to 7.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Circular Column 7.30m to 8.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Circular Column 8.30m to 9.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Circular Column 9.30m to 10.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Circular Column 10.30m to 11.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Circular Column 11.30m to 12.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Circular Column 12.30m to 13.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Circular Column 13.30m to 14.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Circular Column 14.30m to 15.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Square column 0 to 3.30 m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Square column 3.30 to 4.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Square column 4.30 to 5.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Square column 5.30 to 6.30 m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Square column 6.30 to 7.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Square column 7.30 to 8.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Square column 8.30 to 9.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Square column 9.30 to 10.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Square column 10.30 to 11.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Square column 11.30 to 12.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Square column 12.30 to 13.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Square column 13.30 to 14.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Square column 14.30 to 15.30m
Supplying and erecting centering to sides and soffits including supports and strutting with necessary cross bracing for plain surface such as RCC slabs rectangular beams all beams lintels etc., centering for soffits upto 3 meter height using mild steel sheet of size 90 cm x 60 cm x 10 mm gauge with MS angles of size 25mm x 25mm x 3mm laid over silver oak (CW) joists of size 10cm x 6cm spaced upto 90cm c/c and casurina props or 10 cm to 13 cm dia spaced at 0.750 cm c/c complying with standard specifications as per TNDSS NO : 30 & 86 - Square column 15.30 to 16.30m
Supplying and fabrication placing in position of M.S. (or) RTS rods for required size and length as directed by the deparmental officers approved design including bending cutting tying and cost of binding wire cost and conveyance of all materials to site etc., complete as per standard specification
Fiber Reinforced Concrete frane aand Covers As per IS 12592/2002 ,Part 1 & 2 Supply and installation of 600mm dia FRC manhole cover to suit 600 mm clear opening manhole frame (extra heavy duty
Exterior Emulsion paint Two coats with good quality of approved Emulsion paint including cost of all materials to site and all labour charges for mixing applying and proper curring etc., Complete as per Standard Specifications for 10 sqm
Providing and fixing of RCC inner access ladder in RCC 1:1.5:3 (one cement, one and half sane! and three aggregates) using 20mm HBG stone for OHT including cost of reinforcement, placing grill in position, centering shuttering charges, mixing concrete curing etc., to required height and clear width of 4Scm consisting of two Nos. of vertical post of 10cm x lScm and step slab of 2Smm x 25mm etc., complete and as directed by TWAD Board officers. Providing PVC ventilating arrangements mosquito proof nylon net with 1l0mm PVC pipes and cowl and as directed by TWAD Board officers. Providing cut stone slab in CM 1:3 and as directed by Departmental Engineer. - 3.95 m ht
Provision for supply & fixing of MS ladder including Painting etc. complete.
Construction of RCC spiral staircase in RCC 1:1.5:3 (1 Cement : 1.5 Sand : 3 Coarse Aggregate) using 20 mm HBGS of 1.80 m diameter of required height for approach to the roof of Service Reservoir with RCC Handrails including earthwork excavation, providing CC 1:4:8 mix, RCC footing 1:1.5:3 mix, GL platform etc., and also including cost of steel reinforcement, fabrication charges, scaffolding, centering, precasting charges, cement, painting etc. complete as per standard specifications and as directed by Engineer. The staircase shall be braced to the column of service reservoir at suitable interval. (in the BOQ, quantity column the exact height to be mentioned from GL to roof slab bottom to get total value of work to be done.
Supply and delivery of following dia of GI Pipes (Medium) as per IS 1239/Part I 2004 For 65mm GI Pipe
Supply and delivery of following dia of GI Pipes (Medium) as per IS 1239/Part I 2004 For 80mm GI Pipe
Labour charges for Painting Name board inaccordance with the size and specifications as approved by the Board on the Service Reservoirs including cost of all consumables, one coat of base paint, scaffolding charges including painting NRDWP Logo on the Service Reservoirs.
Supply and delivery of following dia of GI Specials as per IS 1239/1239/Part II - For GI unequal tee (Medium) 80 mm x 65 mm
Supply and delivery of following dia of GI Specials as per IS 1239/1239/Part II65mm dia G.I Coupling
Supply and delivery of following dia of GI Specials as per IS 1239/1239/Part II80mm dia G.I Coupling
Supply and delivery of following dia of GI Specials as per IS 1239/1239/Part II65mm dia G.I. Flange set
Supply and delivery of following dia of GI Specials as per IS 1239/1239/Part II80mm dia G.I. Flange set
Supply and delivery of following dia of GI Specials as per IS 1239/1239/Part II65mm dia G.I. Bend
Supply and delivery of following dia of GI Specials as per IS 1239/1239/Part II80mm dia G.I. Bend
Supply and delivery of following dia of GI Specials as per IS 1239/1239/Part IIRubber sheet for Flange of 65mm dia
Supply and delivery of following dia of GI Specials as per IS 1239/1239/Part IIRubber sheet for Flange of 80mm dia
Supply and delivery of following dia of GI Specials as per IS 1239/1239/Part II65mm dia G.I.Reduced Tee Plain
Supply and delivery of following dia of GI Specials as per IS 1239/1239/Part II80mm dia G.I.Reduced Tee Plain
Supply and delivery of following dia of GI Specials as per IS 1239/1239/Part IIMS BOLTS AND NUTS 16 mm dia x 65 to 90 mm length fully threaded bolts and nuts with 2 Nos.
Supply and delivery of G.M Gate Valves as per IS BS 5154 and related IS Specifications For 65mm dia gate valve
Supply and delivery of G.M Gate Valves as per IS BS 5154 and related IS Specifications80mm dia gate valve
Lowering GI pipes and specials in the trenches and laying to proper grade and alignment,jointing with GI Specials and as directed by the Dept officers For 65mm dia GI Pipe
80mm dia GI Pipe
Providing and fixing in position of PVC water bar 150mm wide with single bulb for horizontal joints necessary holders fabrication, the rate inclusive of cost of water bar, holders fabrication and fixing in position etc complete as per standard specification and as directed by the Engineer
Providing and fixing in position of precast RCC (1:11/2:3) Hand rails of approvced design for one meter height by using 20mm HBG stone including cost of all materials, centering, shuttering, strutting, reinforcement, placing of concrete, finishing, curing and fixing in position on the roof slab etc.,complete and as directed by dept officers.
Jointing DI double flanged pipes and specials with rubber insertion or any equivalent to the required specifications with M.S. bolts and nuts etc., complete (including cost of jointing materials) For 100 mm Dia
Jointing DI double flanged pipes and specials with rubber insertion or any equivalent to the required specifications with M.S. bolts and nuts etc., complete (including cost of jointing materials) For 150 mm Dia
Jointing DI double flanged pipes and specials with rubber insertion or any equivalent to the required specifications with M.S. bolts and nuts etc., complete (including cost of jointing materials) For 200 mm Dia
Supplying of following dia. DI class PN 10 Flanged pipes as per IS 8329/2000 with latest Amendment including cost of conveyance, stocking charges, etc., complete as per standard specifications for inlet and outlet of OHT 150 mm Dia (4.00m length pipes)
200 mm Dia (4.00m length pipes)
DI Specials connection arrangements for inlet, outlet, scour and overflow etc, as per approved drawing including cost of specials, labour charges for lifting, aligning, fixing specials to DI pipes etc, complete
Labour for cutting open road for laying water mains or sewer For BT Cutting
Labour for cutting open road for laying water mains or sewer For CC Cutting
Supply & delivery of following sizes of HDPE PIPES confirming to IS 4984/2016 - For 90 mm HDPE PE100PN6
Supply & delivery of following sizes of HDPE PIPES confirming to IS 4984/2016 - For 110 mm HDPE PE100PN6
Supply & delivery of following sizes of HDPE PIPES confirming to IS 4984/2016 - For 125 mm HDPE PE100PN6
Supply & delivery of following sizes of HDPE PIPES confirming to IS 4984/2016 - For 140 mm HDPE PE100PN6
Supply & delivery of following sizes of HDPE PIPES confirming to IS 4984/2016 - For 160 mm HDPE PE100PN6
Supply & delivery of following sizes of HDPE PIPES confirming to IS 4984/2016 - For 180 mm HDPE PE100PN6
Supply & delivery of following sizes of HDPE PIPES confirming to IS 4984/2016 - For 200 mm HDPE PE100PN6
Supply & delivery of following sizes of HDPE PIPES confirming to IS 4984/2016 - For 225 mm HDPE PE100PN6
Supply & delivery of following sizes of HDPE PIPES confirming to IS 4984/2016 - For 250 mm HDPE PE100PN6
Lowering HDPE PE100PN6 pipes and specials to trench and laying to proper grade and alignment and as directed by the Departmental Engineer - For 90 mm HDPE PE100PN6
Lowering HDPE PE100PN6 pipes and specials to trench and laying to proper grade and alignment and as directed by the Departmental Engineer - For 110 mm HDPE PE100PN6
Lowering HDPE PE100PN6 pipes and specials to trench and laying to proper grade and alignment and as directed by the Departmental Engineer - For 125 mm HDPE PE100PN6
Lowering HDPE PE100PN6 pipes and specials to trench and laying to proper grade and alignment and as directed by the Departmental Engineer - For 140 mm HDPE PE100PN6
Lowering HDPE PE100PN6 pipes and specials to trench and laying to proper grade and alignment and as directed by the Departmental Engineer - For 160 mm HDPE PE100PN6
Lowering HDPE PE100PN6 pipes and specials to trench and laying to proper grade and alignment and as directed by the Departmental Engineer - For 180 mm HDPE PE100PN6
Lowering HDPE PE100PN6 pipes and specials to trench and laying to proper grade and alignment and as directed by the Departmental Engineer - For 200 mm HDPE PE100PN6
Lowering HDPE PE100PN6 pipes and specials to trench and laying to proper grade and alignment and as directed by the Departmental Engineer - For 225 mm HDPE PE100PN6
Lowering HDPE PE100PN6 pipes and specials to trench and laying to proper grade and alignment and as directed by the Departmental Engineer - For 250 mm HDPE PE100PN6
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Deartment Engineer - For 90 mm HDPE PE100PN6
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Deartment Engineer - For 110 mm HDPE PE100PN6
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Deartment Engineer - For 125 mm HDPE PE100PN6
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Deartment Engineer - For 140 mm HDPE PE100PN6
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Deartment Engineer - For 160 mm HDPE PE100PN6
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Deartment Engineer - For 180 mm HDPE PE100PN6
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Deartment Engineer - For 200 mm HDPE PE100PN6
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Deartment Engineer - For 225 mm HDPE PE100PN6
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Deartment Engineer - For 250 mm HDPE PE100PN6
SI NO12.14.6 DI Pressure Reducing and Flow Limit Control Valve (PN10/16) with the function to reduce higher upstream pressure into a preset lower downstream pressure and to not allow flow rate in the line to exceed beyond the defined set point. The flow orifice diameter is designed based on the set point as per the design requirement. The set point can be changed to a maximum of +10%.“Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Reducing and flow limit control valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1 and Stainless steel 316 orifice plate shall be as per the set point of flow rate, all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self- cleaning filter to avoid possibility of dirt build up inside the control tubing For Valves 80 mm
SI NO12.14.6 DI Pressure Reducing and Flow Limit Control Valve (PN10/16) with the function to reduce higher upstream pressure into a preset lower downstream pressure and to not allow flow rate in the line to exceed beyond the defined set point. The flow orifice diameter is designed based on the set point as per the design requirement. The set point can be changed to a maximum of +10%.“Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Reducing and flow limit control valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1 and Stainless steel 316 orifice plate shall be as per the set point of flow rate, all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self- cleaning filter to avoid possibility of dirt build up inside the control tubing100 mm
SI NO12.14.6 DI Pressure Reducing and Flow Limit Control Valve (PN10/16) with the function to reduce higher upstream pressure into a preset lower downstream pressure and to not allow flow rate in the line to exceed beyond the defined set point. The flow orifice diameter is designed based on the set point as per the design requirement. The set point can be changed to a maximum of +10%.“Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Reducing and flow limit control valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1 and Stainless steel 316 orifice plate shall be as per the set point of flow rate, all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self- cleaning filter to avoid possibility of dirt build up inside the control tubing150 mm
SI NO12.14.6 DI Pressure Reducing and Flow Limit Control Valve (PN10/16) with the function to reduce higher upstream pressure into a preset lower downstream pressure and to not allow flow rate in the line to exceed beyond the defined set point. The flow orifice diameter is designed based on the set point as per the design requirement. The set point can be changed to a maximum of +10%.“Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Reducing and flow limit control valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1 and Stainless steel 316 orifice plate shall be as per the set point of flow rate, all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self- cleaning filter to avoid possibility of dirt build up inside the control tubing200 mm
SI NO12.14.6 DI Pressure Reducing and Flow Limit Control Valve (PN10/16) with the function to reduce higher upstream pressure into a preset lower downstream pressure and to not allow flow rate in the line to exceed beyond the defined set point. The flow orifice diameter is designed based on the set point as per the design requirement. The set point can be changed to a maximum of +10%.“Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Reducing and flow limit control valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1 and Stainless steel 316 orifice plate shall be as per the set point of flow rate, all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self- cleaning filter to avoid possibility of dirt build up inside the control tubing250 mm
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.6 with ISI mark, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes. - For 80mm sluice valve
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.6 with ISI mark, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes. - For 100mm sluice valve
Supply and delivery of clear water vertical wet type submersible pumpset suitable for not less than 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. Rated capable of discharging noted LPM against head of water column due to all causes.The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 % For 200 lpm against a total head of (110m to 122 m )
Supply and delivery of MS Kiosk of size 0.75m x 0.45m x 0.75m made up of MS angle of size 50mm x 50mmx 4mm alround covered with 16 gauge MS sheet and kiosk door made up of MS plates of size 25 mm x 3 mm including cutting, welding, grinding, locking arrangements and labour charges etc.,
Supply, delivery, erection, testing and commissioning of following sizes of power shunt capacitor for power factor improvement, suitable to operate on 415V, 3Ph,50Hz A/C supply, on suitable angle iron frame-works (37.5 mm x 37.5 mm x 6.24mm ) at a height of 0.25m from the ground, including earthing and incidental civil works etc., complete For 2.5 kVAR
Supplying and fixing of following capacity Triple Pole fuse carrier in MS Sheet steel encloure with provision for accommodating the TNEB meter including earthing etc., complete as per TANGEDCO which includes LT meter panel board For63 Amps
Supplying and fixing of following capacity Triple Pole SFU with fuses on suitable angle iron frame with earth connection only. For 63 Amps
Supplying and laying following LTUG Armoured Aluminium cables in a trench to be excavated at a depth of 2 ½ ' putting 6” layer of sand and covering the cable with brick and sand refilling the earth to make good as directed. DO - 4 core 10 sq.mm. for Incomer.
Supplying and laying following LTUG Armoured Aluminium cables in a trench to be excavated at a depth of 2 ½ ' putting 6” layer of sand and covering the cable with brick and sand refilling the earth to make good as directed. DO - 4 core 4 sq.mm. for Lighting
Supplying and laying following LTUG Copper Flat cables in a trench to be excavated at a depth of 2 ½ ' putting 6” layer of sand and covering the cable with brick and sand refilling the earth to make good as directed. DO - 3 core 6 sq.mm - for pump
Supplying and fixing of cable gland and termination with Aluminium cable lugs for following PVC UG cable and with earth connectionDO - 4 core 10 sq.mm
Supplying and fixing of cable gland and termination with Aluminium cable lugs for following PVC UG cable and with earth connectionDO - 4 core 4 sq.mm
Supplying and fixing of cable gland and termination with copper cable lugs for following PVC UG cable and with earth connectionDO - 3 core 6 sq.mm
Supply, delivery and erection of Three Phase 4 way 32 Amps, 10kA LDB with the following: 1 No of 40 A FP isolator for incoming supply 3 Nos. of 16A, DP RCCB 3 Nos. of 16A, SP MCB 1 No of 16A, DP MCB 3 Nos of 6A, DP MCB in sheet steel enclosure fitted with busbars and neutral links and suitable angle iron frame works with provision for earthing etc. complete.
Run of 2 of 2.5 sq mm PVC unsheathed copper single core cable in PVC pipe for mains with continuous earth connection by 14 SWG wire From the MCB DB to the Switch boards in office, store,and 16A power socket.
Wiring with 2.5 sq mm PVC insulated single core copper cables of 650 V Grade on suitable rigid PVC pipe on wall and ceiling with PVC accessories, with MS switch box covered with 3 mm thick hylam sheet with continous earth wire connection of 14 SWG TC wire.Light points
Earthing as per ISI specifications with necessary masonary work.
Supply and connection of earthing conductor including two coats of approved painting and laying between earth pit and equipment.25 x 6 mm copper Flat
Supply, conveying and fixing GI specials as per the latest revision of IS 1239 including with ISI markings on it including earthwork excavation, lowering into the trenches, aligning, refilling the trenches with excavated soil, watering and ramming to consolidation, etc.50 mm G.I Elbow
Supply, conveying and fixing GI specials as per the latest revision of IS 1239 including with ISI markings on it including earthwork excavation, lowering into the trenches, aligning, refilling the trenches with excavated soil, watering and ramming to consolidation, etc.50 mm GI Coupling
Supply, conveying and fixing GI specials as per the latest revision of IS 1239 including with ISI markings on it including earthwork excavation, lowering into the trenches, aligning, refilling the trenches with excavated soil, watering and ramming to consolidation, etc.50 mm GI Union
Supply, conveying and fixing GI specials as per the latest revision of IS 1239 including with ISI markings on it including earthwork excavation, lowering into the trenches, aligning, refilling the trenches with excavated soil, watering and ramming to consolidation, etc.50 mmMS Clamp Set
Supply, conveying and fixing following GI pipes as per latest revision of IS 1239 with ISI markings - 50 mm G.I pipe - 1 mtr
Supplying, delivery and installation at site, conveying and fixing the GM valves as per IS 5154 with ISI marking including loading, transportation charges and stacking etc complete as per specifications For 50mm GM valve
Supplying, delivery and installation at site, conveying and fixing the GM Reflux valves as per IS 5154 with ISI marking including loading, transportation charges and stacking etc complete as per specifications For 50 mm dia GM non-return valve
Brick work in CM 1:5 (one cement and six sand) using country bricks of size 8.75" X 4.25" X 2.00" including cost of all materials, labour charges, curing etc., complete for Superstructure and as directed Departmental Engineers.
Reinforced cement concrete 1:1.5:3 (one cement, one and half sand, three course aggregate) using 20mm size hard blue granite stone (machine crushed) for beam and roof slab excluding cost of reinforcement, fabrication and placing the grills in position and excluding cost of centering, shuttering, strutting but including curing and finishing mixing concrete using machanical mixer machine and compaction by machanical vibrator etc., complete and as directed by Departmental Engineerss.
Plastering with CM 1:5(one cement and five sand) 12mm thick including cost of materials, labour charges for finishing, curing etc., complete and as directed by Departmental Engineerss.
Finishing the top of flooring with granothatic flooring with cement concrete 1:2:4 (one cement, two sand and four aggrigate) using 10 to 12mm stone chips – 25mm tk etc., Complete.
Special ceiling plastering with CM 1:3 (one cement and three sand) 10 mm thick including labour charges for mixing, finishing , curing etc., complete and as directed by Departmental Engineers.
Supplying and fixing of steel Doors two leaves including all cost , with fitting etc complete as directed by Departmental Engineerss. (the design should be got approved by the SE before supply & fixing)1x2.1m
Supplying and fixing of steel Windows two leaves including all cost , with fitting etc complete as directed by Departmental Engineerss.(the design should be got approved by the SE before supply & fixing)0.9x0.6m
Weathering course with broken Brick Jelly of 20 mm size in pure slaked lime (no sand to be used) over RCC Roof slab with proportion being 32:12 1/2 for required depth of 80mm thickness over the roof slab as required well beaten with wooden beaters for giving required slope complying with standard specification etc., complete and as directed by Departmental Engineerss.
Terrace Flooring with two course of flat tiles using of size 200mmx200mmx20mm laid in CM 1:3(one cement and three sand) mixed with crude oil to 10% by weight of cement and pointed neatly with the same oiled morter etc., complete complying with standard specification and as directed by Departmental Engineerss.
Providing House service connection with suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around including road cutting, replacement of utilities, providing house service connection, refilling, restoration of roads / drains, testing etc complete with the following materials
Kaliyamoorthy
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid