| 1 | L1₹1.5 CrAccepted-Finance 268 237 MASTER KANHAIYA LAL ROAD AISHBAGH AISHBAGH LUCKNOW UTTAR PRADESH 226004 UDYAM UP 50 0018557 | LUCKNOW | UTTAR PRADESH | 226004 | ₹1.5 Cr | L1 | Accepted-Finance Lowest Rate |
| 2 | L2₹1.6 Cr+₹3.3 L (2.14%)Rejected-Finance | ₹1.6 Cr+₹3.3 L (2.14%) | L2 | Rejected-Finance Higher Rate |
Tender Value
Refer Docs
EMD Value
₹3.1 L
Closing Date
19 Apr 2022, 11:00 amClosed
Suprintending Engineer
Suprintending Engineer, U.P. State Construction and Infrastructure Development Corporation Ltd. Lekhraj Market- 1st, IIIrd Floor Indira Nagar Lucknow .
(Balance work) Construction of Natural Science Museum In State Museum Campus At Dist.- Lucknow
2022_SCIDC_686403_1
16/S.E//E-TENDER/2022-23
Open Tender
Civil Works
Item Rate
90 days
Lucknow
(Balance work) Construction of Natural Science Museum In State Museum Campus At Dist.- Lucknow
2 documents required · 2 mandatory
₹2,600
UPSCIDCo.ltd.
₹3.1 L
11.04.2022
29 Apr 2022
9 Apr 2022
19 Apr 2022
9 Apr 2022
19 Apr 2022
9 Apr 2022
11 Apr 2022
Amount
Civil work
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick
Wall painting with Plastic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth Complete.
French spirit polishing : Two or more coats on new works including a coat of wood filler
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing Apron Drain with brick work in cement mortar in proportion 1:6 with half brick thick side and 100mm thick C.C. (1:4:8) base over 40 mm thick C.C. (1:2:4) including 15 mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of the work etc. as specified. 300 mm wide and average 300mm deep.
Providing & laying of 40 mm brick ballast/broken AAC block/ Cinder under floor of toilet /sunken roofs including compacting as per directed by E/I.
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the coloumn pits, wall trenches, basement excavation, top surface of plinth, filling junction of wall and floor, along the external perimeter of binding, expansion joints, surrounding of pipes and conduits etc. complete. Plinth area of the building at ground floor only shall be measured as per I.S.6313 (Part II 1981). Aldrine emulsifiable concrete or any other approved material such as heptachlor or Chlorpyrifos or Chlordane will be used.
External Sewer System
Providing and laying HDPE PIPEwith 6 kg pressure including all assesaries such as valve,service saddle, tee band and trenching,backfilling , shifting of line ,making chamber ,jointing of pipe with butt fusion and testing complete as per desiser of enginee-1-Pipes, 200 mm dia. 2-0.00 to 1.5 m depth
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (1-0.00 to 1.0 m depth 2-
1.01 to 1.5 m depth
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar
C.C Paver Block
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Granular sub -base with close graded material ( Table:400.1): Construction of granular sub-base by providing close graded matrila ,spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. For Grading-I Material (By Mix in Place Method).
Providing and laying Interlocking concrete blocks pavement having thickness 80mm as per drawings and technical specification Clause 1504
SIGN BOARD
Providing Retro-reflective regulatory sign board of size 900 mm dia meter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge.
LANDSCAPE & HORTICULTURE
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm
Fine dressing of the ground
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge..
Preparation of beds for hedging and shrubbery by excavating 60 cmdeep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deepHoles 90 cm dia, and 90 cm deep
SUPPLY OF PLANTS
Supply and stacking of Grevillea robusta (Silver Oak) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer -incharge.
Supply and stacking of Polyalthia pendula (Ashok pendula) plant of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer -incharge.
Supply and stacking of Azadirachta indica (Neem) plant of height 120-130 cm. in big poly bags of size 25 cm as per direction of the officer -incharge.
Supply and stacking of Polyalthia longifolia (Ashok) plant of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer -incharge.
Supply and stacking of Bauhinia blakeana (Kachnar) plant of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer -incharge.
RAIN WATER HARVESTING
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
R.C.C. work with cement approved coarse sand and 2 cm Gauge approved stone ballast in the proportion of 1:1.5:3 in Slab, excluding supply of reinforcement and its binding but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc and also including supply of all materials, labour and T&P etc. required for proper completion of the work. Binding wire cost being included in the item.
Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Thermo-Mechanically Treated bars of grade Fe-500D or more work such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soilBoring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 200 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :
PVC PIPE Line WITH CHAMBER
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 200 mm dia pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round P.V.C. pipes including bed concrete as per standard design:200 mm diameter P.V.C. pipe
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
EXTERNAL WATER SUPPLY SYSTEM
Providing and laying HDPE PIPEwith 6 kg pressure including all assesaries such as valve,service saddle, tee band and trenching,backfilling , shifting of line ,making chamber ,jointing of pipe with butt fusion and testing complete as per desiser of engineer in charge.160 MM
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 With F.P.S. bricks class designation 75, 0.00 to 1.0 m depth
DRAINS
RCC DRAIN 450 MM X 450 MM
Guard Room
WATER SUPPLY AND SANITARY
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I.brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls where required : White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board610X510 mm bowl depth 200mm.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing & fixing PVC waste pipe for sink oncluding PVC waste fitting Complete Flexible Pipe 32mm Dia
40mm Dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing toilet paper holder :C.P. brass
Providing and fixing soil, waste, vent pipes Centrifugally cast (spun) iron S&S pipe100mm dia cast (spun) iron S&S pipe
Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. For 100mm dia. Pipe
Providing and fixing heel rest sanitary bend, in 100mm Centrifugally cast (spun) iron pipe S&S
Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100X100X100mmSand cast iron S&S as per IS : 3989
Providing and fixing PLAIN JUNCTION of required degree 100X100X100mmSand cast iron S&S as per IS : 3989
Providing and fixing terminal guard:100mmSand cast iron S&S as per IS - 3989
Providing and fixing collar.100mmSand cast iron S&S as per IS - 3989
Providing and lead caulked joint 100 Dia
Providing and fixing cast iron trap of self cleansing design with cast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.100 mm inlet and 100 mm outlet,Sand cast iron S&S as per IS: 3989
Painting sand cast iron / centrifugally cast iron( spun) iron soil, waste and vent pipes and fittings with paint of any colour such as chocolate, grey or buff etc. over a coat of primer (of approval quality) for new work100mm dia
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 20 mm nominal outer dia pipes
25 mm nominal outer dia pipes
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :15 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. External work40 mm dia, nominal bore
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)25mm dia, nominal bore
32 mm dia, nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls)20 mm nominal outer dia pipes
25 mm nominal outer dia pipes
Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality40 mm dia, nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work 40 mm dia, nominal bore
Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)15mm nominal bore
20mm nominal bore
25mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality confirming to IS:893115mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.15 mm nominal bore
Providing and fixing PTMT grating of approved quality and colourCircular type100 mm nominal dia
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m :Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round R.C.C. pipes including bed concrete as per standard design : 150 mm diameter R.C.C. pipe
Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than100x100 mm size P typeWith F.P.S. Bricks class designation 75
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia rcc pipe
16 Passenger Lift (G+2)
Supply of Hoist Beam : 100 kg/m x (SOR PWD Item 503)
Add Extra for Supply of Trap Door : 50 kg/sqm x (SOR PWD Item 503)
Cable etc.
Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following sizesize 35 sq mm x 3-1/2core
size 50 sq mm x 3-1/2core
Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer -incharge.for cable size 35 sq mm x 3-1/2core
size 50 sq mm x 3-1/2core
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable size 35 sq mm
size 50 sq mm
S&F of 63 Amp. 415 V metal clad T.P.N. rewireable type switch fuse unit on angle iron bracket complete in all respect. CAT B
Supply and fixing of flush/surface mounting 8 ways SPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by engineer incharge. CAT A
Supply & fixing and making connection of 63 amp. 100mA ELCB/ RCCB of Din Rail mounting in complete in all respect as per direction and satisfaction to the Engineer in Charge.
SITC of 62.5 KVA DG Set
SITC of Silent type D.G. set 62.5 KVA Cummins/Kirloskar make as per below specifications. Diesel Engine SITC of Diesel engine model 4BTAA3.3-G11 developing 84 HP at 1500 RPM, water cooled, four stroke, electric start, Four cylinder engine conforming to BS: 5514 / ISO 3046 with capacity of 10% over loading for one hour in twelve hours operation having following accessories as scope of supply :- AIR INTAKE SYSTEM, EXHAUST SYSTEM, COOLANT SYSTEM, LUBRICATING SYSTEM, FUEL SYSTEM, STARTING SYSTEM, POWERSTART CONTROL MICROPROCESSOR BASED (PS 0600), LED including lamps, Data Logs, Alternator Data, Engine Data, Functions: Control/Protection, Vibration damper & Flywheel with housing.Alternator Synchronous alternator, single bearing, Stamford make of 62.5 KVA rating, suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p.f.(lag), 50 Hz, 3 phase, 4 wire system. The alternator shall be Brushless type, self excited & self regulated through an AVR. The alternator will be suitable for tropical climate and shall generally confirm to IS: 4722. The salient features of the alternator are:- + 1.5% voltage regulation (max) in static conditions. IP: 23 protection with class ‘H’ insulation. Permanent lubricating bearing. Permissible overload of 10% for one hour in 12 hours of operation. Complete with Base Fram, Fuel Tank, Battery & acoustic enclosure is made of 16 gauge CRCA sheet with making of RCC foundation size 3.25 x 1.45 mtr. above ground labour 0.35 mtr. as per enclosed Drawing.
Diesel
Supply & Laying of 25 mm x 3 mm G.I. Strip from earth electrode directly in the ground as required complete in all respect.
Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50 mm, inner Dia 25, terminal Dia 12 mm, outer G.I. pipe of 16 swg and inner G.I. pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25 mm x 3mm G.I. strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Supply & Laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.70 sq.mm x 3½ core.
S&F of 200 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge.
VRV Air Conditioning System
SITC of VRV Air Conditioning System Daikin/'O' General/Mitsubihi Make Outdoor Units - (R410A) - VRT Function Heat Pump with required foundation. ODU - 18 HP
SITC of Indoor Units with Hanging arrangement & proper suport. VRV Round Flow Cassette Type - 3.31 TR
VRV Round Flow Cassette Type - 1.65 TR
VRV Round Flow Cassette Type - 1.06 TR
Supply & Laying of refrigerant copper pipe with (19 mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported.28.6 mm
Providing and fixing rigid PVC piping complete with fitting, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation. Size 32 mm dia.
Providing and fixing control cum transmission wiring of 2 core x 1.5 sq. mm copper in suitable conduits between indoor and outdoor unit.
Supply & Laying of M.S. slotted Angle for pipes and cables horizontaly and vertically along with threaded rod, nut, bolt saddle, tie etc
Automatic Fire Fighting System
SITC of MS black pipe C class (IS 1239/3589) including cutting welding etc providing suitable flanges along with necessary fitting like bends tees etc & anti corrosive Treatment & wrapping coating for in ground pipe. Make Jindal /Qst /Haryana/Tata 200 mm dia
150 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
SITC of first aid hose reel drum with 20mm dia 30 mtr long rubber pipe shut off nozzle 25 mm dia gate valve complete conforming to IS: 884/444 Make:- Safeguard/ lifeguard/ firex /fire matic/ new age/G tec.
SITC of single headed SS hydrant valve comprising of 80 mm dia flanged bend 63 mm dia SS oblique pattern landing valve complete with blank cap etc Make:- Safeguard/lifeguard/ Gtec/Minimax/Safeax/Newage
SITC of RRL hose 63mm dia 15 mtr long complete with SS coupling conforming to IS 636 Make:- Safeguard/ Lifeguard/ Newage/tulsi/Primear
S/F SS Branch pipe with nozzle 63 mm dia conforming to IS: 903 Make:- Safeguard/lifeguard/Newage/ Minimax/Safeax
SITC of Hose Box of 18 SWG MS sheet with glass fronted door including locking aggrement to accommondate 02 nos RRL hose & 01 no SS branch pipe with nozzle (External)
SITC of Hose Box of 18 SWG MS sheet with glass fronted door to accommondate 02 nos RRL hose & 01 no SS branch pipe with nozzle (Internal)
Supply and installation of Air cushion tank assembly 200 mm dia, 1.5 mtr long with air release valve pressure gauge,accessories complete in all respect.
SITC of GM fire bridge 4 way Inlet connection 63 mm dia Make Firex/Safex/ Minimax/Newage.
SITC of cost iron double flanged non return valve complete with nuts bolts & washers etc confirming to IS 5312 Make Kalpna/Aarko /Sir /Kartar/Kirloskar150 mm
SITC of CI double aflanged sluice valve complete with nuts bolts & washers etc confirming IS 780 Make Kalpna/Aarko/Sir/Kartar/ Kirloskar150 mm
SITC of C.I. double flanged Butterfly valve complete with nuts bolts & washers etc confirming IS 780 make:-Kalpna/Aarko/Sir/ Kartar/ Kirloskar150 mm
Supply, Installation, Testing & Commissioning of ball valve 25 mm
SITC of Air Release Valve.
Supply, Installation, Testing & Commissioning of Sprinkler flexible hosepiep 1500 mm
Supply, Installation, Testing & Commissioning of Pendent type sprinkler.
Supply, Installation, Testing & Commissioning of upright type sprinkler
Supply, Installation, Testing & Commissioning of side throw sprinkler
Supply, fixing, testing & commissioning of 25 mm dia. inspecting and testing assembly with gun metal valve, sight glass, by pass valve and connection to the drain line as required completing the system.
Providin & Fixing of 1.6 mm thick M.S / Door Frame Door capable of accomodating fire hose reel landing valve hose pipes fittings & accessories the door shall have a front glass with lock and key arrangment & shall be painted with post office red color (approoval shall be taken on the basis of submitted sample before ordering cost of fire extinguishers not included in item rate. (2100X900X600 mm ) indoor cabinet.
Supply, Installation, Testing & Commissioning of Y type strainer complete with flanges Gasket nut bolts. (Make SIR/VENUS/LP/ KARTAR).150 mm dia
100 mm dia
80 mm dia
Supply, Installation, Testing & Commissioning of Anti Vibration Paid expansion bellow complete with flanges, gasket and nut bolts.100 mm dia
80 mm dia
Supply, Installation, Testing & Commissioning of foot valve complete with flanges, gasket and nut bolts.150 mm dia
100 mm dia
Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. As per electrical SI NO 1131A Rates are inclusive of cess, lavies,royalties, etc. and other taxes but exclusive of GST
Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. As per electrical SI NO 1132 Rates are inclusive of cess, lavies, royalties, etc. and other taxes but exclusive of GST
Automatic Fire Alarm System
Supply, Installation, Testing & Commissioning of addressable low profile optical smoke detectors with base with LED shall be visible from 360 Deg. Intelligent tumpreture from 10 Deg.C to 55 Deg.C. Soft addressing mounting base inbuilt fault for complete as required. (Make: morley/GST/Cooper/ Eaton)
Supply, Installation, Testing & Commissioning of Fault isolater. (Make: morley/GST/Cooper/Eaton) )
Supply, Installation, Testing & Commissioning of integral Microprocessor (not microcontroller) intelligent addressable type manual call point, 1 stage with in-built LED lighting up automatically to confirm its actuation complete as per specification as required. (Make: morley/GST/ Cooper/Eaton)
Supply, Installation, Testing & Commissioning of EN-54/UL listed wall mounted hooter with strobe (100 dba) complete as per specification as required.(Make: morley/GST/Cooper/Eaton))
Supply, Installation, Testing & Commissioning of Microprocessor Based Networkable 2 Loop Analogue Adressable Fire Alarm Control Panel shall be compliant with EN54-2, EN54-4 and approoved by LPCB. The fire alarm control panel shall have expendable capacity from 2 loops to 15 loops the panel must have full color 800x480 LCD with resistive touch screen and automatic backlight dimming the panel must also have the capacity to lake adressable intelligent wired and wireless Devices and 127 Base sounder/base sounder Beacons. the panel shall have an event log of minimum 9,999 events 1 second resolution filterable and printable the panel shall have three access levels panel shall support upto 5000 cause & effects entires with upto 20,000 inputs controlling and 20,000 controlling output across the network the panel shall have capabilty for peer to peer networking through RS 485 network card The Panel must have up to sub-addressabe 512 programmable inputs/outputs via optional RS485 COMMS serially connected extension cards. The panel shall have 240 V AC power supply along with automatic Battery charger. the panel shall be fully expandable via common plug in loop driver boards. the user shall have a choice of using th panel with 10.25 amp power supply unit which is inbuilt in the FACP and should be approoved to En54-4 the panel shall have configurable via USB Port to PC or memory stick the panel shall have dedicated RS 232 serial port optional printer the panel shall have facilty to connect printer to printout log and facilty to have integration with analog/digital voice evacaution system ( which is part of the schedule to work under SH:PA system) and shall be complete with all accessories. The panel shall be compitable for IBMS system with open protocal BACnet/Modbus over IP complete as per specifications Approved by LPCB. 2 Loop Panel.(Make: morley/GST/Cooper/Eaton)
Supply & wiring of submain with 3 no 1.5 sqmm pvc insulated 1100 volt grade single core copper cunductor cable in 20/25 mm dia heavy guage PVC conduit on surface complete in all respect.
Supplying, installation,testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required. (Make: morley/GST/Cooper/ Eaton)
Supply, Installation, Testing & Commissioning of Repeater panel with 320 character Touch screen LCD Display with inbuilt reset, acknowledge and silence switches complete as required. (Make: morley/GST/ Cooper/Eaton)
Supply, Installation, Testing & Commissioning of Response indicator. (Make: morley/GST/Cooper/ Eaton)
Supply, Installation, Testing & Commissioning of Fire control Module. (Make: morley/GST/Cooper/ Eaton)
Supply, Installation, Testing & Commissioning of Adressable Phone control Module. (Make: morley/ GST/Cooper/ Eaton)
Public Addressable System
Supply, Installation, Testing & Commissioning of 6 zone voice alarm controller with USB MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. (Make: morley/GST/Cooper/ Eaton)
Supply, Installation, Testing & Commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. (Make: morley/GST/Cooper/ Eaton)
Supply, Installation, Testing & Commissioning of ceiling/wall loud speakers 3/1.5 watt in ABS enclosure complete as required. (Make: morley/GST/Cooper/ Eaton)
Supply, Installation, Testing & Commissioning of digital audio amplifier 75 watt, 25V rms operating at 240 Volt AC Supply complete as required. (Make: morley/GST/ Cooper/ Eaton)
Supply, Installation, Testing & Commissioning of voice command keypad 6 zone, with microphone assembly as required. (Make: morley/GST/Cooper/ Eaton)
Supply, and Laying OF PVC Pipe 25 mm with 2X1.5sqmm Flexible wire complete the system.
Supplying & Drawing of cable fire retardent PVC Insulated copper conductor cable in the existing surface recessed steel conduit of following pairs cores and size including connections and interconnections as required. 17.5.3.2 speaker cable two pair 2 core 1.5 sqmm
17.5.3.4 speaker cable four pair 2 core 1.5 sqmm
Supplying &fixing 25 mm dia MS Flexible pipe with PVC coating along with all ancillaries and accessories like coupler as required.
Wiring for 2 Nos. Lift
Labour Charges For Fixing of Wiring point for light with 1.5 Sq. mm FR PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earth wire drawn inside. continuity wire, Modular type switch & ceiling rose/angle/ batten holder on 3mm thick phenolic laminated backelite sheet etc. complete in all respect. with Modular Box & Cover plate.
Do as above Item But Fan/Fresh air Fan Point
Do as above Item But Plug Point
Labour Charges For Laying of submains with two number 4 sq.mm FRLSH PVC insulated 1100 Volt grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit with one no. 2.5 sq.mm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. complete in all respect.
Labour Charges For Laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.25 sqmm x 3½ core.
Labour Charges For Laying of 25 mm x 3 mm G.I. Strip from earth electrode directly in the ground as required complete in all respect.
Labour Charges For Burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50 mm, inner Dia 25, terminal Dia 12 mm, outer G.I. pipe of 16 swg and inner G.I. pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25 mm x 3mm G.I. strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Labour Charges For Fixing of 6 Amp. To 32 Amp. SPMCB (10 KA) Cat-A
Labour Charges For Fixing of 40Amp. DP MCB (10 KA) Cat.-A
Labour Charges For Fixing of surface/flush mounting 8 ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge. Cat-A
Labour Charges For Fixing of 16 gauge M.S. drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect.
Labour Charges For Fixing of Power plug with 20A/250 volt flush type modular switch and 5 pin 20A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for completion of work.
Labour Charges For Fixing of hexagonal/Round G.P. fan box of approved make made up 1.0 mm thick ISI Marked G.P. sheet spot welded four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S. bar x 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting along with supply of all material, labour, T&P etc. required for proper completion of work.
Labour Charges For Fixing of Electronic fan regulator(Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper copmletion of work to the satisfaction of Engineer in charge of work.
Labour Charges For Laying of submain with two number 1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit with 1 nos. 1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduite complete in all respect including matching colour wash.
Labour Charges For Fixing of LED Tube Light with batten suitable for up to 1 x 22 watt LED tube light fitting including tube On surface complete in all respect. Cat-AAA
Labour Charges For Fixing of water tight oblong 10 watt LED bulkhead luminaire having die cast housing with driver set confirming to IP 65 and above protection. complete in all respect. 1100 system lumens, 1101m/watt, PF>0.95, with 5 year warrantee Cat AAA
Labour Charges For Fixing of ceiling fan ISI Marked 1200 mm sweep. Usha / Crompton/Bajaj make
Labour Charges For Fixing of LED Bulb 9 watt ISI
Labour Charges For Fixing of 5 Amp Plug & Switch with Modular box, sheet etc.
Labour Charges For Fixing of light duites exhaust fan 12" dia Bajaj / Usha / Cromption make.
Labour Charges For Light duty exhaust fan luvers 12”dia.
Wiring for 2 Nos. Lift
Supply of Required Material for light with 1.5 Sq. mm FR PVC insulated multistrand single core copper conductor cable, PVC conduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earth wire, Modular Box, Covr Plate, Modular type switch & ceiling rose/angle/ batten holder on 3mm thick phenolic laminated backelite sheet etc.
Do as above Item But Fan/Fresh air Fan Point
Do as above Item But Plug Point
Supply of Required Material for submains with two number 4 sq.mm FRLSH PVC insulated 1100 Volt grade multistrand single core copper conductor cable with 20 mm dia heavy duty (2 mm thick) PVC conduit pipe & one no. 2.5 sq.mm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire.
Supply of Required Material for Aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade. with burnt bricks for on sides and on top. On surface sand M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge. 25 sqmm x 3½ core.
Supply of Required Material for 25 mm x 3 mm G.I. Strip.
Supply of Required Material for Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50 mm, inner Dia 25, terminal Dia 12 mm, outer G.I. pipe of 16 swg and inner G.I. pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25 mm x 3mm G.I. strip upto switch board with 30 cm square C.I. frame with hinged cover & masonry housing.
Supply of 6 Amp. To 32 Amp. SPMCB (10 KA) Cat-A
Supply of 40Amp. DP MCB (10 KA) Cat.-A
Supply of Required Material for surface/flush mounting 8 ways SPN distribution board with additional metal door without MCB. Cat-A
Supply of Required Material for 16 gauge M.S. drum duly painted including making hole in the wall for exhaust fan and finishing properly.
Supply of Required Material for Power plug with 20A/250 volt flush type modular switch and 5 pin 20A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material.
Supply of Required Material for hexagonal/Round G.P. fan box of approved make made up 1.0 mm thick ISI Marked G.P. sheet spot welded four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S. bar x 12 mm & brand name should be embossed.
Supply of Required Material for Electronic fan regulator(Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material.
Supply of Required Material for submain with two number 1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable with 20 mm dia heavy duty (2mm thick) PVC conduit pipe & 1 nos. 1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire.
Supply of Required Material for LED Tube Light with batten suitable for up to 1 x 22 watt LED tube light fitting including tube On surface complete in all respect. Cat-AAA
Labour Charges For Fixing of water tight oblong 10 watt LED bulkhead luminaire having die cast housing with driver set confirming to IP 65 and above protection. complete in all respect. 1100 system lumens, 1101m/watt, PF>0.95, with 5 year warrantee Cat AAA
Supply of Required Material for ceiling fan ISI Marked 1200 mm sweep. Usha / Crompton/Bajaj make
Supply of LED Bulb 9 watt ISI
12.5 % bulkage will be deduct from course sand
All rates are F.O.R. Site i/c loading unloading & stacking
G.S.T. Extra as applicable.
All Material will be as per UPPWD Specification & Approved Make.
Genuineness of Panel Board for the purchase of Panel Board from UPPWD Approved manufacturer. must be
Electrical Material make & Specification as per enclosed list.
It will be responsibility of the contractor to obtain NOC of fire fighting work from the fire department executed in Natural Science Museum Building at State Museum Campus Lucknow.
The Bidder must have Authorization from OEM firm Rolex Elevators Private Limited for SITC of Elevator.
Authorization certificate of D.G. Set and A.C. work must be submitted.
Final NOC will be submitted from Fire officer at the time of final payments.
"A" class license holder who valid license from director electrical safety U.P. Government.
Supply of Required Material for 5 Amp Plug & Switch with Modular box, sheet etc.
Supply of Required Material for light duites exhaust fan 12" dia Bajaj / Usha / Cromption make.
Supply of Required Material for Light duty exhaust fan luvers 12”dia.
Mahesh and Copany
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .