Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹22.2 L+₹25,060.30 (1.14%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹22.3 L+₹41,284.30 (1.88%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹22.7 L+₹73,962.30 (3.37%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹22.9 L+₹95,417.30 (4.35%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SHIVAM INDUSTRIES L3 | SWASTIK INDUSTRIES L5 | BHARATI ELECTRICO L18 | International Transformers Pvt ltd L21 | Mahendra Engineering Limited L8 | APS POWER TECH INDIA PVT LTD L20 | TRANSYS ENGINEERS L1 | SUMAN ELECTRICALS L17 | M/S BALAJI TRANSFORMERS L7 | Kailash Transformer L6 | SHIV ENGINEERING L4 | ANAND TRANSFORMERS PVT LTD L12 | J P ELECTRICAL INDUSTRIES L2 | Laxmi Technocrats L14 | KAMLA TRANSFORMERS PVT. LTD. L16 | Keshav Transformers L13 | SAMTECH INDUSTRIES L11 | Transtron Electricals Pvt. Ltd L19 | ABC Transormers Pvt Ltd L9 | Electromec Engineering Enterprises L9 | STAR ENGINEERING INDUSTRIES L15 | Ashoka Electricals L15 | M/S LAKSHMI ELECTRICALS L10 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Labour charges for | ||||||||||||||||||||||||||
| 1.01 | Preliminary inspection of transformers at MVVNL site/workshop involving minor repairs at site/workshop | 1 | Firm | 8,000 ₹27,000 | 10,000 ₹33,000 | 10,000 ₹33,000 | 10,000 ₹33,000 | 10,000 ₹33,000 | 10,000 ₹33,000 | 9,900 ₹32,700 | 10,000 ₹33,000 | 10,000 ₹33,000 | 10,000 ₹32,500 | 9,000 ₹29,000 | 10,000 ₹30,000 | 3,700 ₹12,300 | 10,000 ₹33,000 | 10,100 ₹33,300 | 9,500 ₹31,500 | 9,000 ₹30,000 | 3,100 ₹10,800 Lowest | 9,200 ₹29,700 | 9,200 ₹29,700 | 10,000 ₹33,000 | 10,000 ₹33,000 | 10,000 ₹33,000 |
| 1.02 | Labour Charges for Preliminary inspection of transformers at MVVNL site/workshop for estimation involving major repairs unloading of transformers, at contractors work & repair of transformer cover, draining of oil, if any, detanking core and coil assembly, and replacement of damaged parts, minor repair of core and tank (if required) cleaning washing of dust & dirt etc. from all parts including core tank & cooling tubes of radiators, removal of damaged parts, requiring replacement, fitting, fixing of new parts, making connection & assembly, complete in all respect, re-tanking after repairs, filling fresh transformer oil, making transfomer ready for tests & testing for all tests as per clause 16.0 of Technical specification. | 1 | Firm | 69,000 ₹2,42,000 | 70,000 ₹2,45,000 | 70,000 ₹2,45,000 | 68,000 ₹2,40,000 | 70,000 ₹2,35,000 | 70,000 ₹2,45,000 | 69,500 ₹2,43,500 | 70,101 ₹2,45,090 | 60,000 ₹2,25,000 Lowest | 70,500 ₹2,44,500 | 69,500 ₹2,43,000 | 69,000 ₹2,42,000 | 68,500 ₹2,40,500 | 70,000 ₹2,45,000 | 69,950 ₹2,44,860 | 69,000 ₹2,42,000 | 69,000 ₹2,41,000 | 72,000 ₹2,52,000 | 70,000 ₹2,44,950 | 70,000 ₹2,44,950 | 70,000 ₹2,45,000 | 70,000 ₹2,45,000 | 69,000 ₹2,43,500 |
| 1.03 | HV leg coils complete with insulation, varnishing by vacuum impregnation (if required as per sample) and baking of coil assembly | 1 | Variable | 890 ₹2,670 | 890 ₹2,670 | 900 ₹2,700 | 890 ₹2,670 | 900 ₹2,700 | 900 ₹2,700 | 880 ₹2,640 | 895 ₹2,685 | 900 ₹2,700 | 902 ₹2,706 | 895 ₹2,685 | 900 ₹2,700 | 803 ₹2,409 Lowest | 900 ₹2,700 | 899 ₹2,699 | 880 ₹2,640 | 899 ₹2,697 | 900 ₹2,700 | 890 ₹2,670 | 890 ₹2,670 | 900 ₹2,700 | 900 ₹2,700 | 898 ₹2,694 |
| 1.04 | LV leg coils complete with insulation, vanishing by vacuum impregnation (if required as per sample) and baking of coil assembly | 1 | Variable | 890 ₹2,670 | 890 ₹2,670 | 900 ₹2,700 | 890 ₹2,670 | 900 ₹2,700 | 900 ₹2,700 | 880 ₹2,640 | 895 ₹2,685 | 900 ₹2,700 | 902 ₹2,706 | 895 ₹2,685 | 900 ₹2,700 | 803 ₹2,409 Lowest | 900 ₹2,700 | 899 ₹2,699 | 880 ₹2,640 | 899 ₹2,697 | 900 ₹2,700 | 890 ₹2,670 | 890 ₹2,670 | 900 ₹2,700 | 900 ₹2,700 | 898 ₹2,694 |
| 1.05 | HV bushing 33/37.5 KV | 1 | Firm | 780 ₹2,780 | 790 ₹2,890 | 800 ₹3,000 | 800 ₹3,000 | 750 ₹2,750 | 800 ₹3,000 | 795 ₹2,385 Lowest | 800 ₹3,000 | 800 ₹3,000 | 800 ₹3,000 | 780 ₹2,780 | 790 ₹3,010 | 875 ₹2,625 | 800 ₹3,000 | 800 ₹3,000 | 750 ₹2,850 | 790 ₹2,980 | 1,250 ₹4,300 | 790 ₹2,940 | 790 ₹2,940 | 800 ₹3,000 | 800 ₹3,000 | 795 ₹3,005 |
| 1.06 | LV Bushing 11 KV | 1 | Firm | 480 ₹2,080 | 500 ₹2,260 | 500 ₹2,300 | 500 ₹2,300 | 450 ₹2,050 | 500 ₹2,300 | 480 ₹1,440 Lowest | 500 ₹2,300 | 500 ₹2,300 | 500 ₹2,200 | 485 ₹2,245 | 500 ₹2,300 | 605 ₹2,015 | 500 ₹2,300 | 500 ₹2,300 | 890 ₹2,670 | 500 ₹2,280 | 600 ₹1,800 | 495 ₹2,275 | 495 ₹2,275 | 500 ₹2,300 | 500 ₹2,300 | 500 ₹2,280 |
| 1.07 | HV bushing metal parts | 1 | Firm | 1,100 ₹4,300 | 1,200 ₹4,400 | 1,200 ₹4,600 | 1,200 ₹3,600 Lowest | 1,100 ₹4,300 | 1,200 ₹4,600 | 1,200 ₹4,300 | 1,200 ₹4,600 | 1,200 ₹4,600 | 1,200 ₹4,600 | 1,150 ₹4,450 | 1,210 ₹4,630 | 1,180 ₹4,140 | 1,200 ₹4,600 | 1,200 ₹4,600 | 1,100 ₹4,300 | 1,180 ₹4,540 | 1,600 ₹5,100 | 1,195 ₹4,615 | 1,195 ₹4,615 | 1,200 ₹4,600 | 1,200 ₹4,600 | 1,150 ₹4,600 |
| 1.08 | LV bushing metal parts | 1 | Firm | 2,100 ₹6,900 | 2,150 ₹7,050 | 2,200 ₹7,200 | 1,100 ₹4,100 Lowest | 2,000 ₹7,000 | 2,200 ₹7,200 | 1,200 ₹4,300 | 2,200 ₹7,200 | 2,100 ₹6,900 | 2,200 ₹7,400 | 2,150 ₹7,050 | 2,200 ₹7,180 | 1,700 ₹5,500 | 2,200 ₹7,200 | 2,250 ₹7,350 | 2,100 ₹6,900 | 2,150 ₹7,110 | 1,400 ₹4,500 | 2,200 ₹7,200 | 2,200 ₹7,200 | 2,200 ₹7,200 | 2,200 ₹7,200 | 2,150 ₹7,150 |
| 1.09 | Set of gaskets (rubberized cork) | 1 | Firm | 2,400 ₹8,200 Lowest | 2,500 ₹8,500 | 2,500 ₹8,500 | 2,500 ₹8,500 | 2,500 ₹8,300 | 2,500 ₹8,500 | 2,500 ₹8,300 | 2,500 ₹8,500 | 2,400 ₹8,200 Lowest | 2,500 ₹8,300 | 2,500 ₹8,500 | 2,500 ₹8,500 | 2,400 ₹8,200 Lowest | 2,500 ₹8,500 | 2,550 ₹8,650 | 2,400 ₹8,200 Lowest | 2,480 ₹8,440 | 3,800 ₹12,000 | 2,500 ₹8,450 | 2,500 ₹8,450 | 2,500 ₹8,500 | 2,500 ₹8,500 | 2,600 ₹8,400 |
Tender Value
Refer Docs
EMD Value
₹13.8 L
Closing Date
15 Jun 2021, 1:00 pmClosed
SE MM
4 A GOKHALE MARG LKO
WORK OF REPAIR OF 33-37.5/11 KV 5 MVA, 8 MVA AND 10 MVA DAMAGED / BURNT POWER TRANSFORMERS
2021_MVVNL_592633_1
MEDCO/2582/2021
Open Tender
Miscellaneous Works
Fixed-rate
365 days
Lucknow
As per tender document
2 documents required · 2 mandatory
₹11,800
A/c No. 10101985738, IFS Code-SBIN0003347
₹13.8 L
28 Jul 2021
5 Jun 2021
16 Jun 2021
5 Jun 2021
15 Jun 2021
5 Jun 2021
Amount
Labour charges for
Preliminary inspection of transformers at MVVNL site/workshop involving minor repairs at site/workshop
Labour Charges for Preliminary inspection of transformers at MVVNL site/workshop for estimation involving major repairs unloading of transformers, at contractors work & repair of transformer cover, draining of oil, if any, detanking core and coil assembly, and replacement of damaged parts, minor repair of core and tank (if required) cleaning washing of dust & dirt etc. from all parts including core tank & cooling tubes of radiators, removal of damaged parts, requiring replacement, fitting, fixing of new parts, making connection & assembly, complete in all respect, re-tanking after repairs, filling fresh transformer oil, making transfomer ready for tests & testing for all tests as per clause 16.0 of Technical specification.
HV leg coils complete with insulation, varnishing by vacuum impregnation (if required as per sample) and baking of coil assembly
LV leg coils complete with insulation, vanishing by vacuum impregnation (if required as per sample) and baking of coil assembly
HV bushing 33/37.5 KV
LV Bushing 11 KV
HV bushing metal parts
LV bushing metal parts
Set of gaskets (rubberized cork)
Silicagel breather with fresh Silicagel
Magnetic type oil level gauge with low level alarm contact
Tapping switch 33/37.5 KV complete with handle
Tapping switch handle
Oil drain valve incorporating sampling device (with narrow orifice) & having suitable arrangement for locking
Filter valve
Dial type thermometer of minimum 150 mm dia with maximum temperature indicator complete with resetting device and alarm contacts
Double float Bucholz relay complete with alarm and trip contacts
Air release plug
Pressure Released valve
Replacement of damaged core
Pair of arcing horns 33/37.5 KV
Radiator
Radiator valve
M. S. Clamping ring
Winding temperature indicator (complete set)
Fresh transformer oil of standard quality as per IS:335/83 and latest amendment thereof.
Sundry item viz cover bolt, plug, caps, screw, washers, insulation material, minor repairs of tank, other parts required if any, Aluminium Name Plate etc.
Painting inside & outside of transformer including radiator tubes concervator with suitable primer and two coats of suitable paint of grey colour and marking etc.
Burnt/damaged leg coils to be retained by the contractor
Damaged metal parts of bushing to be retained by contractor
TOTAL
Transportation/Carriage charges
Upto 10 kms.
Above 10 kms. To 25 kms.
Above 25 kms. To 50 kms.
Above 50 km. To 100 kms.
Above 100 kms. To 150 kms.
Above 150 kms. To 200 kms.
Above 200 kms. But upto 300 kms.
Above 300 kms. But upto 400 kms
Above 400 kms. But upto 500 kms
Above 500 kms. Bu upto 600 kms
J P ELECTRICAL INDUSTRIES
SHIVAM INDUSTRIES
SHIV ENGINEERING
SWASTIK INDUSTRIES
Kailash Transformer
M/S BALAJI TRANSFORMERS
Mahendra Engineering Limited
ABC Transormers Pvt Ltd
Electromec Engineering Enterprises
M/S LAKSHMI ELECTRICALS
SAMTECH INDUSTRIES
ANAND TRANSFORMERS PVT LTD
Keshav Transformers
Laxmi Technocrats
Ashoka Electricals
STAR ENGINEERING INDUSTRIES
KAMLA TRANSFORMERS PVT. LTD.
SUMAN ELECTRICALS
BHARATI ELECTRICO
Transtron Electricals Pvt. Ltd
APS POWER TECH INDIA PVT LTD
International Transformers Pvt ltd
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .