Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC GROUND BALURGHAT COMPOUND NEAR TRIPURA ROAD KHANAPARA ROAD GUWAHATI KAMRUP METROPOLITAN ASSAM 781029 | KAMRUP METRO | ASSAM | 781029 | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.8 L+₹1.7 L (5.35%)Rejected-Finance | L2 | Rejected-Finance Other than lowest Bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
25 Apr 2020, 6:00 pmClosed
GE (N) Bikaner
GE (N) Bikaner Mil Stn Bikaner
UTSOURCING SERVICES FOR 1.0 MLD STP AT LONGEWALA COMPLEX AND 1.2 MLD STP AT UMRAO COMPLEX WITH ALLIED WORKS AT MIL STN BIKANER UNDER GE (N) BIKANER
2020_MES_336561_1
GE (N) BKN-Token/71/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Bikaner
Class D and category d (v)
8 documents required · 8 mandatory
₹500
GE (N) Bikaner
₹70,000
Yes
1 Mar 2021
27 Mar 2020
27 Apr 2020
27 Mar 2020
25 Apr 2020
11 Apr 2020
Amount
Schedule 'A' Section I (Note for item No.1 &2 : The rate quoted shall not be less than minimum wages as notified by Government of India/State Government/Local body whichever is higher . In case the rates quoted are less than the minimum wages as notified by the Government of India/State Government/Local body whichever is higher his tender will be treated as NON BONAFIDE and will not be considered for acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid / bonofied bids only) Outsourcing of services for 1.0 MLD STP at longewala complex with 01 FGM in each shift for 3 shifts round the clock and one helper for one shift only will be employed by the contractor (each shift for 08 hours) all as directed by Engineer-in-Charge.
Outsourcing of services for 1.2 MLD STP at Umrao complex(KLP-II) with 01 FGM in each shift for 3 shifts round the clock and one helper for one shift only will be employed by the contractor (each shift for 08 hours) all as directed by Engineer-in-Charge. Notes : For Item No 01 & 02 (i) Daily, weekly, monthly, quarterly, half yearly and annual maint to be carried out and keeping records thereof. (ii) Daily log sheet attendance register for persons employed by the contractor to be maintained. (iii) All types of T&P required for day to day maintenance shall be provided by the contractor. (iv) All types of transportation if reqd for handling materials/eqpts etc shall be provided by the contractor. (v) All types of fire eqpts provided in all the installations shall be maintained and operated properly. (vi) All electrical fitting and fixtures installed at STP installation to be maintained and contractor shall be responsible for any damage. (vii) All types of water tanks shall be maintained. (viii) All installations to be kept neat and clean all the time. (ix) In case of any damage, misuse, mishandling of Govt property, contractor will be held responsible for the same. (x) Chlorination of sewage water are to be carried out from the recognized lab i.e., C.O.D, B.O.D etc and record to be maintained. (xi) Treated water to be tested monthly from recognized lab and record to be maintained. (xii) Medical needs to be provided by the contractor to the employees as and when required. (xiii) First Aid Box with basic medicines to be kept in installation by the contractor. (xiv) Misuse of electricity and water to be penalised and effective recovery will be made by the department. (xv) Outsourcing of services shall start immediately after acceptance of work. (xvi) All garden, lawns, trees etc being planted in all the installations shall be maintained regularly and to be developed further as directed. (xvii) FGM should be ITI qualified or 02 years experience in the particular field. (xviii) Fuel for running of DG Sets of both STP's shall be supplied by the department and contractor shall responsible to collect the fuel from the department by his own arrangement. (xix) Entire area inside and outside of STPs shall be cleaned properly by the contractor and cost shall be deemed included in the quoted rate. (xx) All the FGMs & Helper shall be in proper dress code and shoes as approved by the GE.
Schedule 'A' Section II M & L for taking up incl dismantling, reassembling, transporting and lowering of submersible pump of capacity 13 Mtr head and 42 Mtr Cubic per hours discharge single stage all as specified and directed by Engineer-in-Charge. Make of pump: CALAMA/SABAR/KSB/BED FORD GARVIN/ KIRLOSKAR. Note :- Crane for taking up & lowering of submersible pump set while repairing/rewinding will be arranged by the contractor and the rent for the same is included in the item rate.
Supply & fixing in replacement of the following unserviceable spare parts of submersible pump as per existing make and size against item No 3 above :- (a) S/S Impeller.
(b) S/S Pump shaft (single stage)
(c) Hook bolt (Upper & lower)
(d) S/S neck ring
(e) Key for pump shaft (Each stage)
(f) Distance sleeve
(g) Suction chamber
Dismantling, transporting and reassembling of submersible motor after rewinding & replacement of worn out parts mentioned below incl rewinding of submersible motor 7.5 HP of 03 Phase, 415 volts with PVC insulated solid copper conductor (wire) superior quality of approved make , size & number of wire as per existing complete.
Supply & fix in replacement of the following unserviceable spare parts of submersible motor as per existing make and size against item No 5.00 above :- (a) GM Bearing Bush
(b) Rotor sleeve
(c) Water seal (KSB only)
(d) Cable seal
Dismantling of existing defective induction motor of 7.5 HP capacity, 03 phase, 415 volts 50 HZ and make from the foundation, disconnecting the electric connecting coupling pulley, and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor ( winding wire)as existing size and gauge complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed by Engineer-in-Charge.
Dismantling opening and reassembling after repair /replacement of U/S under mentioned parts of centrifugal pump of capacity 7.5 HP. Job includes disconnection from base foundation frame disconnecting electrically, reconnection, re-fixing in position transportation to work shop & back make of pump :- Kirlosker/Crompton Greaves.
Supply & fix in replacement of the following unserviceable spare parts of centrifugal pump as per existing make and size against item No 8 above :- (a) Gland Bush
(b) Gland Cap CI with nut bolt
(c) Ball bearing for 7.5 HP. Make - SKF. NBC.
(d) Shaft sleeve Bronze
(e) Shaft sleeve nut bronze
(f) Set of gasket
(g) Bearing housing DE
(h) Bearing housing NDE
(j) Flexible Tyres cupling
(g) Motor Terminal plate
(g) Motor Terminal plate
Supply and fixing for replacement of liquid chlorine pump set of capacity 1.0 HP Single phase including all necessary connection, testing complete all as specified and directed by Engr-in-charge. Make : Kirloskar/Milton Roy India (P) Ltd / equivalent
Painting of existing pipe lines at STP with one coat of synthetic enamel paint of colour and shade as approved by the GE including making of arrow mark in the direction of flow complete all as directed by Engineer-in-Charge.
Cleaning of sewage water tank by de-sludging,scraping the bottom wall with the help of scrapper/wire iron brush removing all scales, craked earth, dirt, mud/slit algi, fungus and other foreign deposited materials and dewatering the left over water and taking them out complete and painting of one coat by liquid bleaching powder complete all as specified and directed Engineer-in-Charge.
Cleaning of sewage water well carefully by removing wire mess and lifting the deposited material over the well and taking them out away from well on weekly basis all as specified and directed Engineer-in-Charge.
Cleaning of filter media chambers (04 Nos) by removing deposited material inside the chamber including lifting the material from the chamber and getting out from the chamber without any damage to the chamber on weekly basis including cleaning of filter media all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement MCCB 100 Amp capacity triple pole breaking capacity 25 KA at 415 volts including making connections by using suitable size copper lugs/thimbles and crimping tool complete all as specified and directed by Engr in charge. Make: - L&T/Havells/Crompton greaves
Supply & fix in replacement MCCB 125 Amp capacity four pole breaking capacity 25 KA at 415 volts including making connections by using suitable size copper lugs/thimbles and crimping tool complete all as specified and directed by Engr in charge. Make: - L&T/Havells/Crompton greaves
Supply & fixing in replacement of NRV CI flanged ends ISI marked size 100mm bore with rubber or fibre board gasket including necessary nuts, bolts and washer complete all as specified and directed . Make : LEADER/ KIRLOSKAR/BIR
Taking out/dismantling of unserviceable compressor cap 30 HP including replacement of wornout components such as bearing as per existing size, compressor oil, rubber seal, repair to pump including reassembling installation, connecting and testing etc complete all as specified and directed by Engineer-in-Charge.
(a) Supply and fixing in replacement. Ball Bearing No. 3307 of Make :SKF/NBC
(b) Supply and fixing in replacement. Ball Bearing No 6306 of make : SKF/NBC
(c ) Supply and fixing in replacement. Rubber Seal for 30 HP compressor
(d) Supply and fixing inreplacement fan belt for air blower, induction motor suitable for 30 HP motor as per sample all as specified and directed by Engr-in-Charge.
Taking down of defective induction motor of the following capacity and make from the foundation, disconnecting the electric connecting coupling pulley, and transporting to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor ( winding wire) complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed by Engineer-in-Charge. (a) 30 HP capacity, 03 phase, 415 volt 50 HZ
(b) Supply and Fixing in replacement Ball Bearing No. 6309 for motor Make- SKF/NBC
Supply, hoisting and fixing of Rotational moulded polyethylene water storage tanks of capacity 200 Ltrs, ISI marked, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provison of wash out pipe etc including dismantling water tank and removing to store complete all as specified and as directed by Engr-in charge. Note: (i) The water storage tanks shall be 2 layered, HDPE tanks moulded to seam-less perfection of rotational moulding process. The tanks shall be manufactured only from FDA approved special grade of polyethylene and shall be certified fit for potable water. Also refer paras 18.60 and 18.60 A of MES Schedule Part-I. (ii) Payment for inlet, outlet and over flow pipes and ball valve shall be made seprately. however cost of providing necessary GI fittings such as nipplies with check nuts for inlet and outlet pipes, GI plug with check nut for over flow pipe and 30 cm long wash out pipe, GI 20mm nominal bore, medium grade and check nut for wash out pipes of size as per acturl requirements and as directed by the Engr-in-Charge shall be deemed to be included in the unit rate of this item. (iii) HDPE storage tanks shall be procured form the manufactures as per Appendix "D".
Supply and fixing in replacement of float valves of size 20 mm brass complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of old pattern unservicable street light into LED based street light housing made up of pressure die cast aluminum alloy with effective thermal management, sturdiness. The fixture should have a minimum system efficacy of more than 80 lumens/ watt and a minimum system lumen output of not less than 7200 lumens and maximum system wattage 72 to 90 watts. The fixture shall have a correlated color temperature of at least 5000 K and a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance. Ingress protection of IP65 ( lamp and gear compartment and mechanical impact resistance rating of IK >=05. The fixture driver should have an operating voltage range at 140 – 300 V . Surge protection not less than 4 KV PF >0.95 and the <20%. The fixture should empty with the parameters as per IS10322 and for EMI and IM 79 test reports(Make Philips, Crompton Greave, Bajaj)
Supply and fixing in replacement of LED tube light fitting suitable for 1 x 18/20 Watt with complete with all accessoris including connecting up with twin core twisted flexible copper conductor cable with suitable. Make - CG Cat Part No T5GP28EB or equivalent Surya/Philips/Bajaj.
S&F ih replacement PVC Insulated sheathed 3 core sumersable flate cable for sumserable pumps copper conductor cable (stranded) 1100 Volts grade of size 10 Sqmm
Supply and laying in replacement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core
Supply and laying in replacement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.00 sq mm 2 core
Supply and fixing of sub main 10 Sqmm PVC FRLS insulated cable with multi stranded copper conductor with 6 sqmm PVC FRLS insulated cable with stranded copper conductor as earth continuity including all accessories complete all as directed by Eng-in-charge.
Taking up or down existing old/rusted/worn out cracked/ broken (HDPE) 110 mm bore of pressure rating 6 Kg/Sqmm & connections from wall/ trenches ( Excavation and earth work shall be measured spritely)
Supply and fixing in replacement of highdensity pulythelene pipe (HDPE) 110 mm bore of paressure rating 6 kg/Sqcm conforming to IS 4985, 1988 with all fittings such as ends, elbows, lee, raducing lee, adopters sockets, plugs, climps etc and fixing to walls etc complete with saddles (snap chips), wall clips hooks, complet all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of butter fly valve of size 100 mm bore. Make : BIR/Advance/Leader/Sant
Supply and fixing in replacement of butter fly valve of size 150 mm bore. Make : BIR/Advance/Leader/Sant
Supply and fixing in replacement of butter fly valve of size 80 mm bore. Make : BIR/Advance/Leader/Sant
Supply and fixing in replacement of butter fly valve of size 50 mm bore. Make : BIR/Advance/Leader/Sant
Supply and fixing in replacement of butter fly valve of size 40 mm bore. Make : BIR/Advance/Leader/Sant
Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.0’ of 100 mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable CI sluice valve of 100 mm bore, complete, all as specified & directed.
Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 150 mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable CI sluice valve of 150 mm bore, complete, all as specified & directed.
M & L in replacement cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Eng-in-charge.
M & L for painting of old steet tublar pole upto 9 mtr hight with two coat of approved aluminum paint after scraping of pole complete all as specified and directed by Eng-in-charge.
M & L in replacement of junction box out door type on street light pole of size 30X20X15 cm with 100 Amps capacity 02 Nos aluminum bus bar of suitable size for cable termination mounted on Porcelain insulator and S & F MCB SP 6 Amps in side . The junction box shall be painted with two coats of synthatic enameled paint over a coat of red oxide primer and fixed on pole with clamps of suitable size including cable connection complete all as specified and directed by Eng-in-charge.
M & L in replacement MS pipe medium grade of size 200mm bore in tank of STP's complete all as specified and directed by Eng-in-charge.
All as per item 40.00 above but size 80mm flanged type
Supply & fix in replacement MCCB 200 Amp capacity triple pole breaking capacity 25 KA at 415 volts including making connections by using suitable size copper lugs/thimbles and crimping tool complete all as specified and directed by Engr in charge. Make: - L&T/Havells/Crompton greaves
All as per item No. 42.00 above but MCCB 63 Amps 16 KA
S&F in replacement MCB single pole, 240 volts of rating 6-32 Amps, breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge Make :- Schneider/ HPL/Legrand/ GE/ Seimens/L&T/Indo sian/C&S/Havells/BCH/ABB
S&F in replacement MCB suitable for 6 to 32 Amps, 240 Volt AC supply single pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ GE/ Seimens/L&T/Indo Asian/C&S/ABB/BCH
S&F in replacement MCB suitable for 32 Amps, 415 Volt AC supply triple pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ GE/ Seimens/L&T/Indo Asian/C&S/ABB/BCH
Excavation in trenches in soft/loose not exc. 1.5m wide and not exc. 1.5m in depth and getting out complete all as specified.
Returning filling including spreading, leveling watering and well ramming in soft/loose soil in layers not exc. 25cm thick complete all as specified.
Removing surplus soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed
Protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class 'B' bricks complete all as specified and directed by Engr-in-charge.
Local tibba dry sand cushioning for protection of cable complete all as specified and as directed by Engineer-in-charge. Note Local approved tibba dry sand after removal of vegetations, grass and other deleterious substances shall be used for sand cushioning.
M&L in replacement air pressure gauge round type 0-150 Kg/cm2. make : Guru/ equivenlant
S&F in replacement MPP type heavy duty power factor improvement capacitor ( H/D ) with connector suitable for indoor/outdoor operation and provided with discharge resistors of rated voltage 440 V, 50 HZ 3 phase with delta connection of rating 1 KVAR to 5 KVAR all as specified. Make : Legrand/Siemens/L&T/GE/CG.
Taking out Bio careers media from STP tanks and replaced unservicable/unuseable in to new Bio careers media ( Material : Organic polymer high density polyethylene, mix into nano sized in organic in gradients(cokes powder zeolite etc.)) for proper airation for sewage water specification as under :- (a) Product : Thermak/equivalent (b) Colour : Black (c) Shape : conical furstum / Tube chip shape (d) Avg. Dia : 10mm (e) Length : 17 mm (f) Thickness : 0.3mm (g) Density : 0.97 to 0.98 Gm/Cm² (h) Surface area : 700-800 Sqm/cum (j) detention time : 5 to 12 hrs Note :- Dissolved oxygen concentration in the reacter to be maintained above 4Mg/ltr
Supply only liquid chlorine (Sodium Hypochlorite at 12% to 16% ) all as directed by Engineer-in-Charge. Make- Chloromax/Shree Rayalaseema Hi-Strength Hypo Ltd (i) Sealed packed liquid chlorine container shall be supplied by the contractor on requirement basis at STP. (ii) Transportation incl labour charge will deemed in the item. (iii) The contractor ensure that liquid chlorine shall be kept for one month in advance at STP.
M&L in replacement of GI Pipe medium grade in trenches complete with fittings all as specified and directed by Engr-in-charge. (a) 150mm bore
(b) 100mm bore
(c) 80mm bore
(d) 50mm bore
(e) 40mm bore
( f) 25mm bore
(g) 20 mm bore
Supply and fixing in replacement gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for iron pipe complete all as specified (a) of size 80mm
(b) of size 50mm
(c) of size 25mm
(d) of size 20 mm
S&F detachable joint complete with rubber ring and necessary nut,bolts and washers suitable for CI/GI pipe line complete all as specified and directed by Engr-in-charge (a) 150mm bore
(b) 100mm bore
Cutting of existing CI/GI line of size 100mm/150mm dia bore in position for insertion of new CI fittings complete all as specified and directed by Engr-in-charge
M&L CI fitting such as Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed by Engr-in-charge
Supply and Fixing in replacement off load changover switch 200 Amp 415 Volt AC-23 A 50 Hz 4 Pole front handle operated in sheet metal enclouser complete including fixing connection of cables, nut bolts and washer of suitable sie required for fixing complete all as specified and as directed by Engr-in-Charge.
Material and labour for construction of brick masonary valve pit chamber of size 900x 900 x 600 mm (Internal dimension) using sub class ‘B’ bricks complete, earth work, PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation including necessary excavation RFR & removing of surplus soil etc PCC (1:2:4) type B-1 using 200 mm graded stone aggregate as in coping on top including formwork, internal plaster 10 mm thick in CM (1:4) MS sheet cover 3 mm thick with locking arrangement and hinging device, duly painted with two coats of synthetic enamel paint over a coat of primer red oxide complete all as specified and as directed by the Engineer in charge.
Supply and fixing in replacement of the following spare parts of panels contactor MNX 18 - 25 Amp (Make : L&T/C&F/Legrand)
Supply and fixing in replacement of the following spare parts of panels contactor MNX 50 Amp (Make : L&T/C&F/Legrand)
Supply and fixing in replacement of Relay MN-2 as per sample
Taking out of UNSV analogue Amp meter and supply and fix new digital ebrit panel mounted AC ammeter (0-300A) of size 96 X 96 sqmm flush mounted case three phase, calss 0.5 item code PAMEBRITA 32. Make:-AE/HPL
Taking down UNSV phase indicator lamp supply and fix new phase indicator lamp (red, yellow & blue)
Taking out of UNSV analogue volt meter and supply and fix new digital ebrit panel mounted AC volt meter (0-500A) of size 96 X 96 sqmm flush mounted case three phase, calss 0.5 item code PAMEBRITA 32. Make:-AE/HPL
S&F electronic type single phasing preventer in existing panel boards (max 600v min 380v) three phase 415volts variation voltage 4% tripping time 2-5 sec max type VSP-1 complete all as directed by Engr in charge. Make:- L&T/Minilac/Siemens.
Supply and fix in replacement star delta timer range 0-30 second Make : C&S/L&T /Schiender
Supply and fixing in replacement of connector as per sample
Supply and fixing in replacement of panel lock as per sample
Dis connecting the LT panel of any size and Cap and repair of complete panel by taking out the cable ,MCCB,Bus -bar , Voltmtr , Amp mtr ,including wiring and other minor parts, cleaning the complete accessories carefully. Minor repairs shall be rectified Parts/accessories shall be cleaned properly and refixing the parts at its original locations, checking and repair of the internal panel wiring with suitable size of wire and remove the carbon deposited inside the contact, cleaning all other spare parts all as directed by the Engineer-in-charge and reassembled after repair/replacement of following parts. (Note: Spare parts as required for replacement of existing worm out parts shall be measured and paid separately under appropriate items Nos a to here-in-after as supply only of make Crompton greaves and seimen.)
Cleaning and preparation of old painted surface of LT panel board complete and spray painting with one coat of synthetic enamel paint a all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less then 1.5 meters below normal ground level, connecting alvanized earth lead 32X6 mm Strip from earth plate to running earth wire/over head line conductors along pole by means of bolts, nuts, check nuts and washers of alvanized iron or steel, 40 mm bore GI light grade pipe for protection of earth lead from plate and up to 3.00 meter along pole fixed with two clamps made from mild steel flat iron 25 mm x 3 mm, bolts, nuts & washers etc. 20 mm GI pipe light grade for watering, PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) as in earthing pit. PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing all as specified and shown in electrical plate No.3 of MES Schedule Part-I
M/s Chopra Associates
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .