Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹13.3 L+₹54,720 (4.29%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L2 | Rejected-Finance Greater than L1 | |
| 3 | L3₹14.9 L+₹2.2 L (17.0%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance Greater than L1 | |
| 4 | L4₹15.5 L+₹2.7 L (21.5%)Rejected-Finance FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | L4 | Rejected-Finance Greater than L1 | |
| 5 | Rejected-Technical 503 GIRIRAJ HEIGHT VAITY WADI L B S MARG NEAR HARINIWAS CIRCLE THANE 400 602 | THANE | MAHARASHTRA | 400602 | - | Rejected-Technical NOT HAVING SPECIFIC CATEGORY |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
5 Feb 2024, 6:00 pmClosed
Shri Gaurav Tiwari, IDSE, EE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
REPAIR/MAINT OF FIRE FIGHTING AND ACCESSORIES INCLUDING FIRE DETECTOR, FIRE, ALARM PANEL AT INS SHIVAJI LONAVLA
2024_MES_636244_1
GE/LONAVLA/8212/E8
Open Tender
Civil Works
Item Rate
330 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
6 documents required · 6 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹30,000
Yes
30 Mar 2024
8 Jan 2024
7 Feb 2024
8 Jan 2024
5 Feb 2024
22 Jan 2024
8 Jan 2024 - 21 Jan 2024
Amount
Routine maintenance of fire fighting system & Fire alarm system by attending fault testing of system, Monthly checking of system etc, including replacement of unserviceable component including preventive Maintanence by replacing parts other then mentioned in Schedule ‘ A ‘Part II also for fire fighting system, fire alarm system installed at LOGISTIC Building comprising following: (a) FOUR TO TWENTY Zone main fire alarm control panel with each zone battery charger and 230 V power units. (b) DETECTOR OF ANY TYPE, head detector, response indicator, manual call point and hooters. etc (c) All cable connectors from main control panel to item 1(b) etc. (d) Lead acid battery 12 V / 9 AH Capacity.
All as per above item No 1 but MENAKA , KASTURI Building.
All as per above item No 1 but CAC Building.
All as per above item No 1 but CCEL,SECON Building.
All as per above item No 1 but CMET ADMIN BLDG Building.
All as per above item No 1 but DAG Building.
Supply and fix in replacement Zone cards
Supply and fix in repair replacement power card Make : Gurutronic / Hardik
Supply and fix in replacement of manual call point duly painted in red colour paint fitted with front glass (to be broken in case of fire) complete with test key to check the response with out breaking the glass with LED indicator all as specified Make : Gurutronic / Electronic Control
Supply and fix in repair replacement electronic hooters. Make: Gurutronic / Electronic Control
Supply and fix in replacement smoke detector ionization type Make: Apollo / System Sensor
Supply, install, testing and commissioning “FIRE ALARM CONTROL PANEL” system complete in repairs including wiring stories complete with the following: (a) Manual call point with electronic hooter(one in each floor) ( b ) Factory made vermin proof air tight zone control panel board made out of 16 SWG CRCA sheet enclosure 100mm x 100mm surface type duly powder coated (Red colour) (with arrangement comprising with annunciation system on each floor, indicating (16 zones) 12/24 VDC stand by power supply with trickle boost charger with auto charge over device, panel having test / fault / failure control and indication /annunciation PCB, sound indicator for each zone complete Note: Complete system must be approved by as per BMC latest provisions / requirement and standards
Installation, testing & commissioning for fire alarm system complete all as specified and directed by EIC
M&L converntional type 4 zone fire alarm panel upto 20 detectors per zone with 6 hours battery back up, detector circuit monitored for open circuit, short circuit and detector removal dual alarm lines on 4 zone panel. Auto rest user test facility,class change facility and programmable fire/fault relay complete of approved make including 2 No 6V,4.5AH dry rechargeble battery etc,Make : (VIGHNAHARTA).
M&L for Removable Detector chember including 2 wire plug detector base. model makes of VIGHNAHARTA
M&L for Addressable/Conventional Beam Detector with 4 pieces Reflector, Detection Range 8-50 Meters (Certified by LPCB model makes of VIGHNAHARTA
M&L for Semi Flush Mounting Re-settable (Non-Breaking Glass), Supplied with Special Reset Too Model makes of VIGHNAHARTA
M&L for Conventional Siren(Certificated by LPCB). Model makes of VIGHNAHARTA
M&L FRLS copper armoured cable of cross section 1.5 sqmm, 2 core 1100V grade,laid in duct,fixed on wall/ceilling using GI clips drawn through pipes or fixed to detectors
Supply and Install Terrace pump & Sprinkler Pump electrical driven capacity for discharge 450 LPM at 35 Mtr head
Supply and fix Pressure switch Universal type
Supply and fix Pressure gauge 100 mm dia with ball valve of pressure 25 Kg/Sqcm
Supply and install Fire Fighting motor control panel floor mounting Indoor type fabricated from 2.0 mm thick CRCA sheet, dust and vermin proof complete with aluminium bus bar 200 Amp and with following accessories:- MCCB 4 pole 100 Amps 415 Volt, 25 KA - 01 No (Incomer) Volt & Amps Meter, Indication lamps etc- 01 Set Fully Automatic Star Delta starter for Main Pump,Jacky Pump, Sprinkler Pump complete with MCCB for Main Pump, MCB for Jacky & Sprinkler Pump, Tme relays, Internal wiring etc complete.- 01 Set
Supply and fix fabricated hose cabinet mounted on wall mounted made out of 16 gauge MS Sheet of size 800X600x250mm with double door with 4 mm thick glasses and door frame made of 2.0mm MS sheet painted fire red out side and brilliant white inside yard with lock two keys
Supply and provide reinforced rubber cotton synthetic fibre circular woven jacketted fire delivery hose 63 mm dia treated against rot / mystex having 38KG/cm2 working pressure bearing IS-636 type "A" 15 Mtrs length with male and female coupling confirming to IS-903 all as directed
Supply and fix hose reel swinging wall mounted type comprising rubber hose 19/20mm dia 30m long high pressure double braided bearing IS-5132 type'A' 5 mm bore PVC shut off nozzle and 25mm gunmetal inlet valve conforming to IS-884 and connected to down comer all as directed
Supply & fix fire hydrant landing valve type A (single head outlet) of 63 mm dia conforming to IS 5290 with PVC blank cap and chain and having suitable flanges for 100 mm dia down comer all as directed
Supply and fix gun metal branch pipe 63mm dia male instantaneous inlet threaded outlet fitted with hexagonal based nozzle of 12.5 mm dia heavy duty conforming to IS-903 all as directed
Supply and fix Gun metal fire brigade in let connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet complete with all accessories.
Fabricate, supply and connect air cushion tank (air vessel) 250 mm dia 1000 mm height with dished top made out of 6 mm thick MS plate suitable for floor mounting including 1 No 20 mm dia wet riser including GI Tee of size 100x100x20 mm & Drain Valve 20 mm dia all as directed
Supply and fix Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector all as directed.
Addressable multisensor detector Photoelectric Optical-Heat -Smoke composite Detector; includes B501 base,Sleek,low-profile design,Re movable cover and insect-resistant screen for simple field cleaning,Built-in tamper-resistant feature.
Supply and fix Bulb type gun metal sprinkler head consealed type set to operate at 68 degree C all as directed.
S&F 4c x 1.5 sqmm PVC insulated , FRLS armoured and overall PVC sheathed cable , laid on wall / ceiling using GI clamps as required includung final termination on Repeator Panel. Make :- Polycab
Supply and lay pipe galvanized, “Heavy class”, including fittings, 20 mm dia.
Supply and lay pipe galvanized, “Heavy class”, including fittings, 25 mm dia.
Supply and lay pipe galvanized, “Heavy class”, including fittings, 40 mm dia.
Supply and lay pipe galvanized, “Heavy class”, including fittings, 50 mm dia.
Supply and fix Short circuit isolators.
cooltech engineering services
Shree Ayyappa Engineering
M/S SOMANATH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .