| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 CrAccepted-AOC FLAT NO 32 SHRADHA APARTMENT HB TOWN PARDI NAGPUR 440035 | NAGPUR | NAGPUR | MAHARASHTRA | 440035 | L1 | Accepted-AOC Award Of Contract, Bidder is L1. | |
| 2 | Rejected-Technical | - | Rejected-Technical Technically Not Qualified. |
Tender Value
₹27.9 Cr
EMD Value
₹14.0 L
Closing Date
20 Mar 2024, 2:00 pmClosed
S. E. (NMRDA)
S. E. (NMRDA), Station Road, NMRDA, Head Office, Sadar, Nagpur.
CONSTRUCTION OF INTERIOR WORK, PROVIDING, FIXING AND COMMISSIONING OF 7D AND DOME THEATRE IN THE TOURIST RECREATION CENTER BUILDING (TRC) AT SHREE MAHALAXMI JAGDAMBA SANSTHAN PREMISES AT KORADI, TALUKA KAMPTEE, DISTRICT NAGPUR
2024_NMRDA_1021002_2
E-TENDER NOTICE No. 29/ 2023-24
Open Tender
Civil Works
Percentage
730 days
Nagpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹25,000
₹14.0 L
NMRDA Nagpur
8 Oct 2024
4 Mar 2024
21 Mar 2024
4 Mar 2024
20 Mar 2024
4 Mar 2024
7 Mar 2024
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and Fabricating Structural Steel Work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed, including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. SSR 2022-23 Item No. 23.01 Sr. No. 816, Page No. 173, BdC 2 Page No.275. | 18.71 | One Metric Tonne | - | - |
| 2 | Providing Structural steel work in Hollow Sections of various thickness and sizes in Square, Rectangular and Round shape from 25mm to 450mm section as per IS-4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed design and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, Making rivetted / bolted / welded connections and painting coomplete. SSR 2022-23 Item No. 23.12 Sr. No. 826, Page No. 174 As directed by Engineer-In-Charge. | 2 | One Metric Tonne | - | - |
| 3 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -12 mm dia 240mm depth. SSR2022-23, Item No. 53.03, Sr.No.2128, Page No. 460, Bd.C2 Page No. 275. | 60 | One Number | - | - |
| 4 | Supplying, drilling/cleaning hole and fixing of Torque Controlled Expansion Anchor HST3, of sizes ranging from M8 to M24. The Anchor should be third party tested, possess ETA approval and should be pre-assembled with a galvanized bolt as per EN ISO 4042: 1999, ingenious expansion sleeve M10 and M16 (galvanized) and M8, M12, M20, M24 - Stainless Steel (EN ISO 4042: 1999), a nut of Strength Class 8 (EN ISO 20898-2:2012) and a galvanized washer (EN ISO 4042:1999). The anchor should be approved for use in Cracked Concrete. Anchor must be tested and approved as per Seismic C1 and C2 Category of TR045. ETA to have Fire Resistance values for up to 120 mins as per EOTA TR 020 and FM Approval (use in Pipe Hangers). Anchor shall be fixed at right embedment depth as per embedment mark and activated using AT Tool Module to ensure adequate torque as per manufacture’s torque tolerance published in ETA and same shall be documented and submitted to Project Manager at the time of inspection. Design of Anchor should be done as per ETAG 001 Annex C and TR045 using PROFIS Software as per actual load data and site conditions as provided by structural consultant and the report to be submitted to the project manager and design engineer for approval. Scanning before drilling to be done with PS Scanning tool to avoid rebar hits. stud anchor HST3 SS M20x170 - SSR 2022-23 Item No. 53.23, Sr.No. 2128, Page No. 460, Bd C2 Page No. 275. | 10 | One Number | - | - |
| 5 | Supplying, drilling/cleaning hole and fixing of Torque Controlled Expansion Anchor HST3, of sizes ranging from M8 to M24. The Anchor should be third party tested, possess ETA approval and should be pre-assembled with a galvanized bolt as per EN ISO 4042: 1999, ingenious expansion sleeve M10 and M16 (galvanized) and M8, M12, M20, M24 - Stainless Steel (EN ISO 4042: 1999), a nut of Strength Class 8 (EN ISO 20898-2:2012) and a galvanized washer (EN ISO 4042:1999). The anchor should be approved for use in Cracked Concrete. Anchor must be tested and approved as per Seismic C1 and C2 Category of TR045. ETA to have Fire Resistance values for up to 120 mins as per EOTA TR 020 and FM Approval (use in Pipe Hangers). Anchor shall be fixed at right embedment depth as per embedment mark and activated using AT Tool Module to ensure adequate torque as per manufacture’s torque tolerance published in ETA and same shall be documented and submitted to Project Manager at the time of inspection. Design of Anchor should be done as per ETAG 001 Annex C and TR045 using PROFIS Software as per actual load data and site conditions as provided by structural consultant and the report to be submitted to the project manager and design engineer for approval. Scanning before drilling to be done with PS Scanning tool to avoid rebar hits. stud anchor HST3 M24x200 30, SSR 2022-23 Item No. 53.24, Sr.No. 2129, Page No. 460, Bd C2 Page No. 275. | 10 | One Number | - | - |
| 6 | Suppling, Drilling/Cleaning hole and fixing make heavy duty ETA Approved Chemical Anchor of appropriate size and fixing plates subsequently. Anchor comprises of HVU-2 flexible foil capsule that contains styrene free Urethane Methacrylate resin, hardener, quartz, sand/corundum and HAS-U threaded rod of minimum 5.8 steel grade, galvanized to minimum 5 microns. Anchor should be approved for cracked concrete, seismic & diamond drill holes. Manufacture should submit Anchor Design report based on design loads & other parameters as provided by consultants. Chemical anchors should be designed in accordance with EOTA-TR-029 “guidelines for anchorage of chemical anchors for use in concrete” for approval. Application at site should be done as per manufacturer guidelines. Any report submittal with Installation pictures should be done using CFS-DM Software, which shall be charged extra. AnchorHVU2+ HAS U M12x110-90, SSR 2022-23 Item No. 53.27, Sr.No. 2132, Page No. 462, Bd C2 Page No. 275. | 78 | One Number | - | - |
| 7 | Suppling, Drilling/Cleaning hole and fixing make heavy duty ETA Approved Chemical Anchor of appropriate size and fixing plates subsequently. Anchor comprises of HVU-2 flexible foil capsule that contains styrene free Urethane Methacrylate resin, hardener, quartz, sand/corundum and HAS-U threaded rod of minimum 5.8 steel grade, galvanized to minimum 5 microns. Anchor should be approved for cracked concrete, seismic & diamond drill holes. Manufacture should submit Anchor Design report based on design loads & other parameters as provided by consultants. Chemical anchors should be designed in accordance with EOTA-TR-029 “guidelines for anchorage of chemical anchors for use in concrete” for approval. Application at site should be done as per manufacturer guidelines. Any report submittal with Installation pictures should be done using CFS-DM Software, which shall be charged extra. Anchor HVU2+ HAS U M16x125. SSR 2022-23 Item No. 53.28, Sr.No. 2133, Page No. 462, Bd C2 Page No. 275. | 78 | One Number | - | - |
| 8 | Suppling, Drilling/Cleaning hole and fixing make heavy duty ETA Approved Chemical Anchor of appropriate size and fixing plates subsequently. Anchor comprises of HVU-2 flexible foil capsule that contains styrene free Urethane Methacrylate resin, hardener, quartz, sand/corundum and HAS-U threaded rod of minimum 5.8 steel grade, galvanized to minimum 5 microns. Anchor should be approved for cracked concrete, seismic & diamond drill holes. Manufacture should submit Anchor Design report based on design loads & other parameters as provided by consultants. Chemical anchors should be designed in accordance with EOTA-TR-029 “guidelines for anchorage of chemical anchors for use in concrete” for approval. Application at site should be done as per manufacturer guidelines. Any report submittal with Installation pictures should be done using CFS-DM Software, which shall be charged extra. Anchor HVU2+ HAS U M20x170. SSR 2022-23 Item No. 53.29, Sr.No. 2134, Page No. 462, Bd C2 Page No. 275. | 10 | One Number | - | - |
| 9 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. Columns as per detailed designs and drawings or as directed including centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) , SSR 2022-23 Item No. 25.33, Sr.No. 842, Page No. 180 Bd.F.5 Page No. 300 and B- 7,Page No 38. SECOND FLOOR | 0.97 | Cubic Metre | - | - |
| 10 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade), SSR 2022-23 Item No. 25.52, Sr.No.847, Page No. 181, Bd.F.6 Page No. 300 and B.7, Page No.38. SECOND FLOOR | 6.08 | Cubic Metre | - | - |
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BOQ_1793153.xls
BOQ • 0.61 MB
141105209.pdf
Tender Documents • 0.39 MB
141105211.html
Tender Documents • 0.03 MB
DrawingDetails_I.pdf
Tender Documents • 3.36 MB
DrawingDetails_II.pdf
Tender Documents • 0.66 MB
ScheduleC.pdf
Tender Documents • 0.35 MB
TenderDocuments.pdf
Tender Documents • 2.73 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .