Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAccepted-AOC 60 4 MOTILAL GUPTA ROAD GROUND FLOOR KOLKATA 700 008 | KOLKATA | WEST BENGAL | 700008 | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹42.1 L+₹18,289 (0.44%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹44.7 L+₹2.8 L (6.62%)Rejected-Finance BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹49.0 L+₹7.0 L (16.7%)Rejected-Finance VILL PUILLYA PO UNSANI DISTT HOWRAH PIN 711302 | HOWRAH | WEST BENGAL | 711302 | L4 | Rejected-Finance Other than lowest |
Tender Value
₹38.7 L
EMD Value
₹77,440
Closing Date
16 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
PROVN OF RE-ROUTING OF LT CABLES AROUND RNC OF CERTAIN UNIT, SPL REPAIRS TO UNSV LIGHT PANELS AND CABLE AT JCO MAP PUMP HOUSE AND PUMP HOUSE NO 01, PROVN OF RP POST NEAR RHQ GATE AND PROVN OF GALVANISED SHED FOR COVERING AREA FROM OR MESS TO ROTI MAK
2022_MES_529665_2
GE(FW)/8852/E8
Open Tender
Civil Works
Item Rate
210 days
GE(FW) Kolkata
Ref tender documents
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹77,440
7 Oct 2022
30 Jul 2022
17 Aug 2022
30 Jul 2022
16 Aug 2022
30 Jul 2022
Amount
SCHEDULE 'A' PART-I (B/R WORKS) Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in soft/loose soil and getting complete all as specified and as directed.
Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and as directed.
Removal of excavated material to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
M&L for excavating in post holes (or similar holes) each not exceeding 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earh around in layers not exceeding 25 cm for soft/loose soil complete all as specied and directed.
M&L for Hardcore of gauge not exc 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to true surface with broken stones complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B1 using 20 mm graded aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones , bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping for rough finished surfaces complete all as specified and directed
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces complete all as specified and directed
M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces complete all as specified and directed.
M&L for RCC 1:2:4 type B1 using 20mm grade stone aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed (NOTE: MS reinforcement shall be measured and paid seperately)
M&L for RCC 1:2:4 type B1 using 20mm grade aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed (NOTE: MS reinforcement shall be measured and paid seperately)
M&L for RCC 1:2:4 type B1 using 20 mm graded aggregates in chajjas complete all as specified and directed. (NOTE: MS reinforcement shall be measured and paid seperately)
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
All as per item No 15 above but 6mm to 8mm dia complete all as specified and directed
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required as in reinforcement and binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed
M&L for brickwork with fly-ash bricks (with old size bricks), straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed
M&L for brickwork with fly-ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed
M&L for rendering 10mm thick on fair faces of brick work or concrete wall surfaces in cement mortar 1:4 finished rendering is to be finished even and smooth without using extra cement complete all as specified and directed
M&L for rendering 15 mm thick to fair faces of brick work / concrete surface in cement mortor (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick to fair faces of brick work / concrete surface in cement mortor (1:4) finished even and smooth without using extra cement complete all as specified and as directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
S&F 0.71 mm thick plain aluminium sheeting alloy 31000 H4 as in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) etc complete all as specified and directed. .
S&F Mild steel screw bolts (purpose made) with hexagonal or square heads at one end & screwed the other or screwed both ends each screwed end to be fitted with washers & one hexagonal or square nut, exc 30 cm long, diameter exc 12 mm but not exc 20mm complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces exc 10 cm width or girth including preparation of surfaces complete all as specified and directed.
M&L for preparing newly plastered surfaces of wall and applying Two Coats of weather proof exterior emulsion paint over a coat of alkali resistant primer complete all as specified and as directed
M&L for providing on new plastered surfaces of walls applying two coats of distemper oil emulsion over one coat of alkali resistant primer complete all as specified and directed.
M&L for providing on new plastered surfaces of ceilings applying three coats of white wash complete all as specified and directed.
M&L for 2nd class hardwood, plain soild, straight chowkhats and frames, wrought, framed rebated on the soild, rounded or chamfered, put together, with glue, pinned at joints complete all as specified and directed.
S&F 30mm thick Factory made 2nd class hard wood glazed & skleton shutters, open rebated and prepared to received glass, gauge etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a) complete all as specified and directed.
S&F Factory made 35mm thick with 2nd class hard wood, rail and style factory made plain framed panelled shutter(two panel) with lock, rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail & style as per IS:1003(Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as specified and directed. (Note: Stainless steel butt hinges and necessary S.S screws shall be paid separately)
S&F factory made single extruded WPC (Wood Polymer composite) solid door/window/ceosetory windows & other frames/chowkhat of size 45x70mm comprising of virgin PVC polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 grams) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N(Edge), minimum compressive strength of 58N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with mild steel hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed. (Note: MS hold fast/lugs or SS dash fasteners shall be paid for seperately. For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made)
M&L mild steel bands and straps support or stays holdfast and similar articles conforming complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, treating ends of posts, back of chowkhats etc, with tar or coal tar black paint, area tarred exc 0.1 sqm but n. exc 0.5 sqm each complete all as specified and directed.
-ditto- but treating small articles such as holdfasts, ends of posts, back of chowkhats, etc, area n exc 0.1 sqm each
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F 4mm thick ordinary quality plain sheet glass glass and glazing in square n.exc. 0.5 Sqm in each pane complete all as specified and directed.
S&F butt hinges, medium weight, stainless steel, 100mm complete all specified and directed
S&F 150mm extruded aluminium handles, fabricated type, anodised complete all specified.
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all specified.
S&F 300mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all specified.
Preparing new surface of wood or wood based material of any description and in any position not otherwise described n.exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of wood primer complete all as directed.
M&L Non Skid joint free coloured tiles 8-9 mm thick, area of each tiles exc 0.18 sqm but n.exc 0.38sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and incl 15mm thick screed bedding in cement mortar 1:6 complete all as a specified and as directed
-ditto- but in skirting over screed bed of 10 mm thick cement mortar 1:3
SCHEDULE 'A' PART-II (EXTERNAL ELECTRIFICATION WORKS) M&L for dry sand cushioning/sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed. NOTE: Punned thickness only shall be measured for payment)
Supply and laying bricks with sub class 'B' locally available laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Laying only old bricks (retrieved during taking out of cable) in trenches above sand cushioning for cable protection complete all as specified and as directed.
Laying only old PCC cable cover (retrieved during taking out of cable) in trenches above sand cushioning for cable protection complete all as specified and as directed.
Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :- (Note :- Earth work to be measured and paid separately.
25 Sqmm, 4 core
120 Sqmm to 185 Sqmm, 3.5 core
240 Sqmm to 400 Sqmm, 3.5 core
Relaying of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall / passing through pipe/ pole. (retrieved against item No 1 above) complete all as specified and directed by the Engr-in-Charge of the following sizes :- (Note : Earth work shall be measured and paid separately under respective items)
120 Sqmm to 185 Sqmm, 3.5 core
240 Sqmm to 400 Sqmm, 3.5 core
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole complete of the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
25 Sqmm, 4 core
120 Sqmm, 3.5 core
185 Sqmm, 3.5 core
240 Sqmm, 3.5 core
400 Sqmm, 3.5 core
S&F 100 mm bore galvanized iron pipe (light grade) with all fittings, fixed complete to wall / ceiling or laid in floor or fixed along pole for cable/earth strip protection with proper size clamps, nuts & bolts for fixing ightning conductors complete all as specified and directed.
S&F 40 mm bore galvanized iron pipe (light grade) with all fittings, fixed complete to wall / ceiling or laid in floor or fixed along pole for cable/earth strip protection with proper size clamps, nuts & bolts for fixing ightning conductors complete all as specified and directed.
S&F cable route indicator (blue in colour) for LT UG cable of 1100 volts, with embossed letters, min 80 mm dia, made from 5 mm thick cast iron plate 80 mm dia, bolted with 40 x 40 x 6 m angle iron of height 0.60 mtr above GL, embedded in PCC (1:3:6) type C2 (using 40 mm graded aggregate) of size 200 x 200 x 200 mm block, complete all as specified and directed. (NOTE: Cost of PCC is deemed to be included in quoted rate)
S&F heat shrinkable straight through Joints using suitable jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :-
120 Sqmm, 3.5 core
185 Sqmm, 3.5 core
240 Sqmm, 3.5 core
400 Sqmm, 3.5 core
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of indoor type LT panel board, cubical type, dust and vermin proof, made out of 2.0 mm thick CRCA sheet of size 1800 mm x 1500 mm x 500 mm, fabricated in CPRI approved factory with front and back openable door (with locking arrangement) and making compartment for each ACB/MCCB/change over switch separately, duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer inclusive of four numbers copper bus bar of 300 Amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron frame with base 40x40x6 mm with legs not more than 600mm long including grouting with PCC 1:2:4 type B1 complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories :-
INCOMING MCCB, 4 pole, 36 KA, thermal magnetic release, 250 Amps, Ics=100% of Icu, 415 Volts AC - 01 No. (Make: L&T, Cat No: CM92109OOP1OG / HAGER, Cat No: HN251DR / SCHNEIDER, Cat No: LV431640 / LEGRAND, Cat No: 4202 49)
CT's of ratio 300/5A - 01 Set (Set of 03)
LED indicating Lamp with holder for main supply & standby supply indicating RYB (Set of three) - 01 Set
OUTGOING MCCB, 3 pole, 25 KA, thermal magnetic release, 160 Amps, Ics=100% of Icu, 415 Volts AC - 01 No. (Make: L&T, Cat No: CM90638OOMO / HAGER, Cat No: HHS160DR / SCHNEIDER, Cat No: LV426209 / LEGRAND, Cat No: 4200 47)
MCCB, 3 pole, 25 KA, thermal magnetic release, 100 Amps, Ics=100% of Icu, 415 Volts AC - 01 No. (Make: L&T, Cat No: CM91612OOKOOG / HAGER, Cat No: HHS100DR / SCHNEIDER, Cat No: LV426207 / LEGRAND, Cat No: 4200 45)
MCCB, 3 pole, 25 KA, thermal magnetic release, 63 Amps, Ics=100% of Icu, 415 Volts AC - 01 No. (Make: L&T, Cat No: CM91612OOHOOG / HAGER, Cat No: HHS063DR / SCHNEIDER, Cat No: LV426205 / LEGRAND, Cat No: 4200 43)
Fully automatic Star Delta Starter 50 HP with motor protection relay suitable for motor protection against overload, single phasing, reverse running, abnormality in supply, unbalanced current - 01 No (Make: L&T, Cat No: SS94021 / BCH, Cat No: NASACT2LEDM or equivalent model in C&S / SCHNEIDER/HAVELLS)
Fully automatic Star Delta Starter 30 HP with motor protection relay suitable for motor protection against overload, single phasing, reverse running, abnormality in supply, unbalanced current - 01 No (Make: L&T, Cat No: SS94364 / BCH, Cat No: NASAPLEN or equivalent model in C&S / SCHNEIDER/HAVELLS)
Star Delta Starter 15 HP with motor protection relay suitable for motor protection against overload, single phasing, reverse running, abnormality in supply, unbalanced current - 01 No (Make: L&T, Cat No: SS96257POCO / BCH, Cat No: NASAKLEN or equivalent model in C&S / SCHNEIDER/HAVELLS)
AMF panel board for 130 KVA capacity DG Set - 01 Set
CT's ratio 200/5A - 03 Sets (Set of 03)
MCB, 10 kA, SP, 6-32 Amps - 03 Nos
Hooter 220 Volts - 01 No
LED indicating Lamp with holder for main supply & standby supply indicating RYB (Set of three) - 01 Set
Note:-(i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All ACB, MCCB & Changeover to be connected internally with suitable size of copper strip.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .