Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC 344 1 SB GORAI ROAD HILL VIEW PARK NORTH ASANSOL | ASANSOL | WEST BENGAL | L1 | Accepted-AOC Accepted | |
| 2 | L2₹10.0 L+₹5,010.32 (0.50%)Rejected-Finance 00 DEY ENTERPRISE SODEPUR 9 10 PITS COLLIERY ASANSOL BARDHAMAN WEST BENGAL 713372 | PASCHIM BARDHAMAN | WEST BENGAL | 713372 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹10.1 L+₹8,774.03 (0.88%)Rejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | L3 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | WEST BENGAL ENGINEERING CO. L3 | EASTERN INDIA SALES AND SERVICE L1 | DEY ENTERPRISE L2 |
|---|---|---|---|---|---|---|
| 1.00Supply , delivery at Intake (Raw water) pumping station near Durgapur Barrage | ||||||
| 1.10 | Supply of Power Contactor, Contactors conform to IS/IEC 60947-4-1, Contactors and bi-relays have been tested for type-2 coordination
at Iq = 50kA, upto 415V AC, 50Hz with Double break parallel bridge contact mechanism (for aux contact) with 2NO + 2NC aux contact Make-SIEMENS, Model-3TF56,400A,Aux.
Voltage-110V AC | 4 | each | 1,26,441 ₹5,05,764 | 1,25,500 ₹5,02,000 Lowest | 1,26,128 ₹5,04,512 |
| 1.20 | Supply of Power Contactor,Contactors conform to IS/IEC 60947-4-1, Contactors and bi-relays have been tested for type-2 coordination
at Iq = 50kA, upto 415V AC, 50Hz , Double break parallel bridge contact mechanism (for aux contact) with with 2NO + 2NC aux contact Make-SIEMENS, Model-3TF55,300A,Aux.
Voltage-110V AC | 2 | each | 1,08,544 ₹2,17,088 | 1,07,200 ₹2,14,400 Lowest | 1,07,736 ₹2,15,472 |
| 1.30 | Finishing the end of following XLPE/PVC armoured cables by
crimping method incl. supplying and fixing solderless socket
(Dowels make), tapes, anticorrosive paste & jointing materials :
v)3½ core 300 sqmm cable | 36 | /set | 929 ₹33,444 | 922 ₹33,192 Lowest | 927 ₹33,372 |
| 4.00 | Fitting fixing on Emergency basis attending on fault, fault identification, Control circuit checking, Power Circuit checking,Fault rectification by Dismantle of 3 nos Power Contactor , after that new 3 nos contactor re-install/ refitting , testing and power charging
(HSN/SAC CODE-998717) | 2 | each | 26,699 ₹53,398 | 26,500 ₹53,000 Lowest | 26,633 ₹53,266 |
| 5.00 | Attending the fault at Intake, Bankura District with carrying different Testing, Servicing kit/machine like Insulating Resistance Checking machine (1 KV), Blower, Multimeter, Clamp meter, Different type of tools tackles, Various Testing Wires, MCBS, Wires & Cables, HT insulation Tapes, Gas can with nozzle, CRC, WD-40, Lecta Cleaner, Adhesive non Adhesive PVC Tape and items for complete servicing and testing the Starter Panels,
(HSN/SAC CODE-998717) | 2 | each | 17,480 ₹34,960 | 17,350 ₹34,700 Lowest | 17,437 ₹34,874 |
| 6.00 | Add: 18% GST | 1 | L.S | 1,52,037.72 ₹1,52,037.72 | 1,50,712.56 ₹1,50,712.56 Lowest | 1,51,469.28 ₹1,51,469.28 |
| 7.00 | Add: 1% Cess | 1 | L.S | 9,966.92 ₹9,966.92 | 9,880.05 ₹9,880.05 Lowest | 9,929.65 ₹9,929.65 |
Tender Value
Refer Docs
EMD Value
₹22,000
Closing Date
5 Jun 2026, 6:00 pmClosed
Executive Engineer, BMD, PHED
Office of the Executive Engineer. Bankura Mechanical Division. P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102.
Supply , delivery and fiting fixing of 400 amp and 300amp Power Contactor with other works at Intake (Raw water) pumping station near Durgapur Barrage under Barjora , Bankura I and II Block water supply scheme under Bankura Mechanical Division
2026_PHED_1024011_13
WBPHED/EE/BMD/NIeT-1 OF 2026-2027
Open Tender
MECHANICAL
Item Rate
30 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹22,000
Yes
20 Jul 2026
20 May 2026
8 Jun 2026
20 May 2026
5 Jun 2026
20 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply , delivery at Intake (Raw water) pumping station near Durgapur Barrage | |||||
| 1.1 | Supply of Power Contactor, Contactors conform to IS/IEC 60947-4-1, Contactors and bi-relays have been tested for type-2 coordination
at Iq = 50kA, upto 415V AC, 50Hz with Double break parallel bridge contact mechanism (for aux contact) with 2NO + 2NC aux contact Make-SIEMENS, Model-3TF56,400A,Aux.
Voltage-110V AC | 4 | each | 1 | ₹4 |
| 1.2 | Supply of Power Contactor,Contactors conform to IS/IEC 60947-4-1, Contactors and bi-relays have been tested for type-2 coordination
at Iq = 50kA, upto 415V AC, 50Hz , Double break parallel bridge contact mechanism (for aux contact) with with 2NO + 2NC aux contact Make-SIEMENS, Model-3TF55,300A,Aux.
Voltage-110V AC | 2 | each | 2 | ₹4 |
| 1.3 | Finishing the end of following XLPE/PVC armoured cables by
crimping method incl. supplying and fixing solderless socket
(Dowels make), tapes, anticorrosive paste & jointing materials :
v)3½ core 300 sqmm cable | 36 | /set | 3 | ₹108 |
| 4 | Fitting fixing on Emergency basis attending on fault, fault identification, Control circuit checking, Power Circuit checking,Fault rectification by Dismantle of 3 nos Power Contactor , after that new 3 nos contactor re-install/ refitting , testing and power charging
(HSN/SAC CODE-998717) | 2 | each | 4 | ₹8 |
| 5 | Attending the fault at Intake, Bankura District with carrying different Testing, Servicing kit/machine like Insulating Resistance Checking machine (1 KV), Blower, Multimeter, Clamp meter, Different type of tools tackles, Various Testing Wires, MCBS, Wires & Cables, HT insulation Tapes, Gas can with nozzle, CRC, WD-40, Lecta Cleaner, Adhesive non Adhesive PVC Tape and items for complete servicing and testing the Starter Panels,
(HSN/SAC CODE-998717) | 2 | each | 5 | ₹10 |
| 6 | Add: 18% GST | 1 | L.S | - | - |
| 7 | Add: 1% Cess | 1 | L.S | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.35 MB
Tendernotice_2.pdf
PDF • 1.11 MB
BOQ_2517685.xls
BOQ • 0.34 MB
datecorrigendum.pdf
PDF • 0.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .