| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.55Accepted-AOC 209 210 AGGARWAL TOWER PLOT NO 2 SECTOR 5 ROHINI NORTH WEST DELHI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | Hytek Turnkey Projects Pvt. Ltd. L1 |
|---|---|---|---|---|
| 1.00 | Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. | 2,300 | P.Mtr | 40 ₹92,000 Lowest |
| 2.00 | SITC of 3 loop panel expendable upto 6 loops Micro processor based 2 wire fault tolerant loop, with inbuilt network port (each loop accessing 99 detectors and 99 modules) fire alarm / detection control panel. The panel shall have 1000 event log history. Panel shall be capable of having configurable zones. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/ OFF respective control module when ever any alarm is triggered. The panel shall have 7 inch Touch Screen unit to indicate fire / fault signal with address and analog output, external to log all fire or fault events complete in all respect. The panel shall be sheet steel painted, sealed to IP30. The Panel shall have provision for 40 Zones with individual LED indicators expandable upto 200 zones. The panel shall have a built in power supply and battery charger alongwith maintenance free 24 AH, 2x12 volt SMF lead acid batteries cablable of running for a minimum of 48 hours with battery charger complete as required and as per specifications. conforming to BS5839 Standards and duly approved by EN54/UL/VDS/ LPCB. the panel shall support detection logics like coincidence and verification detections for the false alarm management. The panel shall adjust the sensitivity between day and night to maintain the better detection / repones time. other specififcation as per DNIT in PDF.entire satisfaction of Engineer-in- charge of the work. Make Siemens/ Honeywell Morley/ GST. | 1 | Each | 3,90,000 ₹3,90,000 Lowest |
| 3.00 | SITC of Analog Addressable type Active Repeater fire alarm panel with Backlit LCD Display, having controls for reset, mute, Accept, Silence alarms and self test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make Siemens/ Honeywell Morley/ GST. | 2 | Each | 89,500 ₹1,79,000 Lowest |
| 4.00 | SITC of addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required. Detetctor should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) Make Siemens/ Honeywell Morley/ GST. | 415 | Each | 3,070 ₹12,74,050 Lowest |
| 5.00 | Supply, Installation, Testing & commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED etc. complete as required. Each Detector should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make Siemens Cerberus/ Honeywell Morley/ GST. | 4 | Each | 3,200 ₹12,800 Lowest |
| 6.00 | SITC of Addressable Control Relay Module with flexible network structures with a maximun switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Make Siemens/ Honeywell Morley/ GST. | 1 | Each | 5,400 ₹5,400 Lowest |
| 7.00 | SITC of UL/EN54/LPCB listed and FM Approved Line Isolator for Isolating the section of circuit in case of short in the addressable Loop wiring Make Siemens Cerberus/ Honeywell Morley/ GST. | 22 | Each | 3,800 ₹83,600 Lowest |
| 8.00 | SITC of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/ voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Make Siemens/ Honeywell Morley/ GST. | 1 | Each | 5,400 ₹5,400 Lowest |
| 9.00 | SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make Siemens/ Honeywell Morley/ GST | 15 | Each | 3,800 ₹57,000 Lowest |
| 10.00 | SITC of Addressable Loop powered sounder with strobe / flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make Siemens/ Honeywell Morley/ GST. | 15 | Each | 6,890 ₹1,03,350 Lowest |
Tender Value
₹25.5 L
EMD Value
₹51,000
Closing Date
4 Aug 2025, 5:00 pmClosed
NAVIN KUMAR
ED - Gurgaon
REPLACEMENT OF FIRE ALARM SYSTEM INSTALLED IN 100 BEDDED CIVIL HOSPITAL AT PALWAL
2025_HRY_460317_1
20252C5BB219 FA34 4C1E BFA2 0456333E5F27664BAR
Open Tender
Electrical Works
Works
120 days
Palwal
2 documents required · 2 mandatory
₹5,000
₹51,000
Yes
27 Oct 2025
23 Jul 2025
5 Aug 2025
23 Jul 2025
4 Aug 2025
23 Jul 2025
23 Jul 2025 - 24 Jul 2025
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .