Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being Lowest L1 | |
| 2 | L2₹21.6 L+₹74,586.60 (3.57%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹21.9 L+₹1.1 L (5.15%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹22.9 L+₹2.0 L (9.63%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹23.7 L+₹2.8 L (13.4%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
24 Mar 2022, 6:00 pmClosed
GE (AF) Pathankot
GE (AF) Pathankot-145001
REPAIR/MAINT OF CEILING FAN, EX FAN, WALL MOUNTING FAN AND INCLUDING REWIRING OF OLD UNSERVICEABLE ALUMINIUM POINT WIRING WITH MISC ITEM AT AIR FORCE STATION PATHANKOT
2022_MES_511479_1
8420/GE/PAF-73/2021-22
Open Tender
Support/Maintenance Service
Item Rate
270 days
GE (AF) Pathankot
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Pathankot
₹70,000
Yes
1 Jun 2022
3 Mar 2022
26 Mar 2022
3 Mar 2022
24 Mar 2022
17 Mar 2022
Amount
Taking down Fan,Ex Fan,Wall Fan any size ,sealing cable end,dismantling blades and removing fan and blades to MES Store Yard For Repair Comple all as specrified and directed by Engrs-In-Charge.
Dismantling of unservicable fan/Exhaust fan at any location and checking defective parts removing capacitor carefully for overhauling checking serviceability of bearings/bush, winding etc cleaning the fan reassembling after replacing the unserviceable parts (To be paid under relevant item of the BOQ) and testing the same complete all as specified and directed by Engrs-In-Charge.
Hanging only Celing fan, Exhaust Fan,Wall mounting Fan and connecting up celing rose to fan connector complete all as specrified and directed by Engrs-In-Charge.
Cutting of old brun winding of Celing fan and Rewinding of ceiling fan with New super enemalled copper same gauge wire including varnishing, drying paper insulation material complete of 1200 mm sweep complete all as specified and directed by Engrs-In-Charge.
Cutting of old brun winding of Celing fan and Rewinding of ceiling fan with New super enemalled copper same gauge wire including varnishing, drying paper insulation material complete of 1400 mm sweep complete all as specified and directed by Engrs-In-Charge.
Cutting of old brun winding of Exhaust fan and Rewinding of Exhaust fan with same gauge as per existing gauge super enamalled copper wire including varnishing, drying paper insulation material complete of 450 mm sweep complete all as specified and directed by Engrs-In-Charge.
Cutting of old brun winding of Exhaust fan and Rewinding of exhaust fan with same gauge as per existing gauge super enamalled copper wire including varnishing, drying paper insulation material complete of 300/380 mm sweep complete all as specified and directed by Engrs-In-Charge.
Supply only fan capacitor 4 mfd complete all as specified and directed by Engrs-In-Charge.
Supply only fan capacitor 3.15 mfd complete all as specified and directed by Engrs-In-Charge.
Supply only fan capacitor 2.5 mfd complete all as specified & directed by Engineer-in-Charge.
Supply and fixing Ceiling fan shaft of standard size including taking out old shaft, complete and all as specified.
Supply and fix metal louver for exhaust fan of size from 225 mm to 450mm sweep or as per sample complete all as specified and directed by Engrs-In-Charge.
Supply and fix Wall mounted Air Circulator fans 230 volts single phase oscillating 300 mm sweep suitable for wall mounting complete all as directed by Engr In Charge.
Supply and Fixing Exhaust fans AC single phase plastic body 230/ 240 V of size 250 mm sweep with louver including cutting of existing wall/ surface and making good surface complete all as specified and directed by Engrs-In-Charge..
Supply and Fixing Exhaust fans AC single phase steel body 230/ 240 V of size 300 mm sweep with louver including cutting of existing wall/ surface and making good surface complete all as specified and directed by Engrs-In-Charge.
Replacement of ball bearing suitable for ceiling fan upto 1200/1400mm sweep complete and all as specified by Engrs-In-Charge.
Replacement of ball bearing for exhaust fan/pedestal fan/air circulator/table fan upto 450mm sweep complete and all as specified by Engrs-In-Charge.
Cleaning thoroughly Pedestal, Wall Fan, Exhaust Fan, ceiling fans 48"/56" (1200mm / 1400mm) sweep with Kerosene Oil and painting with one coat of synthetic enamelled paint including preparation of surfaces, complete all as specified & directed by Engineer-in-Charge
Replacement of wire guard/grill suitable for pedestal/Air circulator fan upto 500mm sweep complete (as per sample) and all as directed by Enge-in-Charge.
Replacement of fan blade set heavy duty suitable for pedestal/air circulator fan 400/500 mm sweep, complete (as per sample) and all as directed by Engineer-in-Charge.
All as per item No 20 above but made of plastic suitable for fans upto 300mm sweep complete al as specified and directed by Engineer-in-charge.
Supply and fixing fan blade set 1200/1400mm sweep complete (as per sample) and all as directed by Engineer-in-Charge
Supply and fixing ceiling fan hanging hook clamps (for fixing to ceiling fan rod) made with using GI of suitable size as directed and with heavy duty rubber insulator and two Nos nuts and one bolts including split pin complete all as directed by Engrs-In-Charge.
Replacement of PVC insulated flexible copper conductor cable 3 core of size 0.75 sqmm cut to length as required for connection from connector block of ceiling fan to ceiling rose/connector block of wiring complete all as specified and directed by Engineer-in-Charge.
Suply and fixing lower and upper canopy of fans of ceiling fans of suitable size required at site as directed by Engr-in-Charge.
Replacement of gun metal bush with suitable size, gun metal bush for ceiling fan any make, any size and sweep complete all as specified and directed by Engineer-in-Charge. .
Replacement of rubber reel with nut bolts of ceiling fan with rubber reel heavy duty for hanging fan complete all as specified and directed by Engineer-in-Charge. .
Replacement of connector block of ceiling fan of suitable size of approved quality complete all as specified and directed by Engineer-in-Charge. .
Replacement of down rod 90 cm long for ceiling fan 1200/1400mm sweep including clamps, reel, lock nuts, split pin etc complete and all as directed by Engineer-in-Charge
Replacement of down rod 60 cm long for ceiling fan 1200/1400mm sweep including clamps, reel, lock nuts, split pin etc complete and all as directed by Engineer-in-Charge
Disconnecting electrically dismantling and taking out electric energy meter any type and capacity and depositing to MES Store Yard complete including Supply and fix single phase temper proof Electric Energy meter with LCD display 240 volts 2 wire system, 10-60 amps, 50 HZ having accuracy class 1.00 as per IS-13779 complete with all standard anti temper features including logging & display of tamper data complete including sealing properly using lead seals and wires as required complete all as specified and directed by Engineer-in-Charge.
All as per item No.31 above but three phase temper proof Electric Energy meter with LCD display 415 volts 4 wire system, 10-80 amps, complete all as specified and directed by Engineer-in-Charge
Cheching of electronic energy meter single phase/three phase up to 60 Amps after disconeeting proper electric coneection from main board and refixing in same or other location incl sealing proper lead seals and wires as required complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Meter box suitable for fixing of two meters with locking arrengement of suitable size including fixing old meter in new box all as per directed by Engr-in-Charge
Supply and fixing in replacement Meter box suitable for fixing of one meters with locking arrengement of suitable size including fixing old meter in new box all as per directed by Engr-in-Charge
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator light fittings etc and removing from site and making good disturbed surfaces of walls floors etc. complete all as specified and directed by Engr-in-charge.
Point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS grade in and including medium duty concealed PVC conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following. (Note: Colour code shall be maintained as per IE rule). (a) One light point/ /Fan/Exhaust /bell buzzer point controlled by one, one way switch
(b) One three pin 5 Amp socket on same board with other switches.
(c) One three pin 5 Amp socket on independent board
(d) One light point controlled by one, two way switch
All as per item No.37 above before but with 2.5 Sqmm (nominal area) wire/cable for phase & neutral for one 3 Pin 15 amp socket on independent board including one 2.5 sqmm PVC insulated unsheathed multi stranded copper conductor cable FRLS,1100 volts grade as earth continuity conductor upto common earth & connected to earth dolly complete all as specified and directed by Eng.-in-charge.
Point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS grade in existing steel/PVC conduit with existing sunken box, for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following. (Note: Colour code shall be maintained as per IE rule). (a) One light point/ bell buzzer point controlled by one, one way switch
(b) One three pin 5 Amp socket on independent board
(c) One light point controlled by one, two way switch
All as per item No. 39 above but with 2.5 Sqmm (nominal area) wire/cable for phase & neutral for one 3 Pin 15 amp socket on independent board including one 1.5 sqmm PVC insulated unsheathed multi stranded copper conductor cable FRLS,1100 volts grade as earth continuity conductor upto common earth & connected to earth dolly complete all as specified and directed by Eng.-in-charge
Supply and fixing switch piano flush type single pole one way 230 Volts 5/6 Amp complete all as specified and directed by Engrs-In-Charge.
Supply and fixing switch piano flush type single pole two way 230 Volts 5/6 Amp complete all as specified and directed by Engrs-In-Charge.
Supply and fixing socket outlet 3 pin, 230 Volts 5/6 Amps flush type multipurpose 5 pin complete all as specified and directed by Engrs-In-Charge.
Supply and fixing bell push flush type 5 Amps 230 Volts single pole complete all as specified and directed by Engrs-In-Charge.
Supply and fixing Socket outlet multipurpose having provision for 3 pin, 230 Volts 15/16 Amp and 3 pin, 5/6 Amp piano flush type ISI marked complete all as specified and directed by Engrs-In-Charge.
Supply and fixing Switch piano flush type single pole, one way, 230 volts 15/16 Amps ISI marked complete all as specified and directe by Engrs-In-Charge.
Supply and fixing Call bell ding dong type AC 230 Volts single pole complete all as specified and directed by Engrs-In-Charge.
Supply and fixing step type regular socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts 6 Ampds 120 watts complete all as specified and directed by Engrs-In-Charge.
Supply and fixing ceiling rose surface bakelite 3 terminals of size 65x25mm complete all as specified and directed by Engrs-In-Charge.
Supply and fixing lamp holder polycarbonate insulated body with back plate complete all as specified and directed by Engrs-In-Charge.
Supply and fixing mirror light decorative compact luminarious with decorative ends caps 10/12 watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engrs-In-Charge.
Supply and fixing decorative wall mounting made out of polycarbonated suitable for and incl 07 watts LED bulb (For Bed room, living room or any other location) complete all as specified and directed by Engrs-In-Charge.
Supply and fixing LED box type T/L fitting pre-wired for LED tube with enegry efficient LED tube extruded aluminium heat sink & high efficiency diffuser 4 Ft version for 16/18 Watts, Base and 16/18W LED rod including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required complete all as specified and directed by Engrs-In-Charge.
Supply and fixing of LED Bulk head light fitting 1x 10w including LED driver complete all as specified and directed by Engrs-In-Charge.
Sub main wiring with 2 Single core FRLS PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sqmm (nominal area) drawing in and including 20mm dia medium duty PVC concealed conduit and conduit accessories and fittings. Including one single core green colour FRLS, PVC. Insulated unsheathed multi stranded copper conductor cable of size 4.0 Sqmm as earth continuity conductor upto common earth and connected to earth dolly complete all as specified and directed by Engrs-In-Charge. (Note: Three run 4 Sqmm cable and one run conduit shall be measured as one run.)
Sub main wiring with 2 Single core FRLS PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 6Sqmm (nominal area) drawing in and including 20 mm dia medium duty PVC concealed conduit and conduit accessories and fittings. Including one single core green colour FRLS, PVC. Insulated unsheathed multi stranded copper conductor cable of size 6.0 Sqmm as earth continuity conductor upto common earth and connected to earth dolly complete all as specified and directed by Engrs-In-Charge. (Note: Three run 6 Sqmm cable and one run conduit shall be measured as one run.)
Sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sq.mm. (nominal area)drawn in existing surface / concealed conduit and fittings. Insulated unsheathed FRLS cable copper conductor multistranded of size 6 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified and directed by Engrs-In-Charge.
Sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sq.mm. (nominal area)drawn in existing surface / concealed conduit and fittings. Insulated unsheathed FRLS cable copper conductor multistranded of size 4 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified and directed by Engrs-In-Charge.
Material and labour for Distribution board SPN 8 Way double door, for mounting MCBs isolator, ELCBs etc factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, painted in seven tank process. The DBs shall be of IP 43 protection complete all as specified and directed by Engrs-In-Charge. Note:- DB and MCCB/MCB shall be of same make
Material and labour for Distribution board SPN 4 Way double door, for mounting MCBs isolator, ELCBs etc factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, painted in seven tank process. The DBs shall be of IP 43 protection complete all as specified and directed by Engrs-In-Charge. Note:- DB and MCCB/MCB shall be of same make
Material and labour for Distribution board Vertical type TPN 4 Way (V TPN) double door, including MCCB 100 Amps MCCB, 4 pole as incoming and MCBs for outgoing factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, painted in seven tank process. The DBs shall be of IP 43 protection incl taking out old u/s complete all as specified and directed by Engrs-In-Charge.
Supply and fixing of MCB SP 6 to 32 Amp, 240 Volts, 'B' curve having breaking capacity 10 KA, complete all as specified and directed by Engrs-In-Charge.
Supply and fixing of Isolator SPN 40 Amps 'B' curve 240 Volts having braking capacity 10 KA, complete all as specified and directed by Engrs-In-Charge.
Earthing complete with galvanized steel earth plate electrode 600mmx600mmx6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with a 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4mm. dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe medium 15 mm bore and water pipe 20 mm. bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & 75 mm thick RCC (1:2:4) type B1 cover slab reinforced with 8mm TMT bars 100mm c/c both ways complete all as specified & shown in elect plate No. 3 of SSR part I of 2009 and testing on completion. (Note:- (i) If the desired earth resistance is not found within permissible limit shall be redone by the contractor at no extra cost. (ii) Cost of GI wirre 4 sqmm and 15mm dia pipe medium grade upto 7.5 mtr is included in the rate quoted for this item).
Service connection with 6 sq mm twin core Weather proof multistranded aluminium conductor cable PVC sheathed PVC insulated round suspended with earthing and clamp etc from Pole to pole complete including desmantling of old unserviceable service connection with suspended wire and insulator shall be removing from site complete all as specified and directed by Engrs-In-Charge.
All as per item No 65 above but size of cable 10 Sqmm twin core complete all as specified and directed by Engrs-In-Charge.
Dismantling and taking down u/s surface/recess mounted CFL fittings (3X36/2X36 watt) of any wattage and size incl fixing recess LED 600x600mm fitting made of CRCA powder coated finish with fully covered by PMMA acrylic difusser, LED used shall be SMD type and fixture should have minimum efficacy at system level (not chip level)capacity & 36 wattage or higher wattage >85 lumen/watt CCT upto 6500K CRI >80 PF>0.95 or higher side including driver minimum internal surge protection 2.5 Kv including dismantling existing ceiling and refixing the same all as specified and directed by Eng-in charge.
Supply and fixing Sheet metal enclosures with socket plug Top and MCB single pole and neutral enclosure with a two pin and earth plug and socket complete 20 Amp capacity complete all as specified and directed by Engrs-In-Charge.
Supply and fixing Meter Distribution Borard made out of Thermoplastic polycarbonate of size 600x600x170 mm (dust proof & weather proof ,Shock proof, rust proof ,corrosion free ,acid & Chemical resistance ,UV resistance ,Halogen free & freerecyclable material) wiyh 230v Ac 50 HZ 3 Wire , Gasket shallbe embedded with T-locking arrangement and suitable for mounting of Electronic Meter -04 Nos including taking out u/s broken/rusted box of any size and type complete all as specified and directed by Engrs-In-Charge.
pardeep singh marwaha
Surya & Gautam Builders
SATISH AND CO
M/S SINGHAL ENGINEERS
M/S BR ENTERPRISES
Vijay Kumar Contractor and Engineers
JCC ENGINEERS PRIVATE LIMITED
PAWAN KUMAR GOVT. CONTRACTORS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .