| 1 | L1₹31.1 LAccepted-AOC B 1203 VRINDA RESIDENCY BARIATU ROAD RANCHI JHARKHAND 834009 | RANCHI | RANCHI | JHARKHAND | 834009 | L1 | Accepted-AOC MS Arics Infrastructure is lowest and accepted | |
| 2 | L2₹31.9 L+₹86,942.13 (2.80%)Rejected-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹33.0 L+₹1.9 L (6.23%)Rejected-Finance 3B CHANDRALOK APARTMENT 3RD FLOOR KUTCHERY ROAD RANCHI JHARKHAND PIN 834001 | RANCHI | JHARKHAND | 834001 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹35.7 L+₹4.7 L (15.0%)Rejected-Finance WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹35.9 L+₹4.9 L (15.7%)Rejected-Finance 337 B ROAD NO 04 ASHOK NAGAR RANCHI 834002 JHARKHAND | RANCHI | JHARKHAND | 834002 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹35.9 L
EMD Value
₹71,840
Closing Date
21 Mar 2024, 6:00 pmClosed
Sh Y K Gour
HQ CWE Ranchi, MES, Dipatoli Cantt
Provision of 02 X Transformer and allied works at Dipatoli under GE Dipatoli
2024_MES_643487_1
80599/1515/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE Dipatoli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Dipatoli
₹71,840
Yes
HQ CWE Ranchi
15 Apr 2024
22 Feb 2024
28 Mar 2024
22 Feb 2024
21 Mar 2024
7 Mar 2024
22 Feb 2024 - 29 Feb 2024
29 Feb 2024
Amount
Supplying, installing on 04 pole structuer connecting, testing & commissioning mineral oil immersed, natural air-cooled, outdoor type, double wound (copper) distribution transformer, three phase, 250 kVA rating, non sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, 11000 V/ 415-240 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +5% to -10% in steps of 2.5% for variation of HV, minimum energy efficiency level-2, 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 amendment upto and including amendment No. 4 with all fittings, accessories and item completeas specified and directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available.
Supplying, installing on 2 pole structure, connecting, testing & commissioning mineral oil immersed, natural air-cooled, outdoor type, double wound (copper) distribution transformer, three phase, 100 kVA rating, non sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, 11000 V/ 415-240 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +5% to -10% in steps of 2.5% for variation of HV, minimum energy efficiency level-2, 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 amendment upto and including amendment No. 4 with all fittings, accessories and item complete as specified and directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available.
M &L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of earth pit not less than 0.90x 0.90 x 2.25 mtr below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth strip of size 32 x 6 mm, 7.5 mtr long (Min) by means of brazing nuts, bolts, check nuts, & washers ,testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I filling with charcoal dust , and common salt , including necessary excavation and earth work in any type of soil ,perforated watering pipeof size 15 mm dia,funnel with wire mesh,earth strip protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EIC Note : (i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately. (ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm (Min) top of GI Plate.
S&F for GI earth strip (32x6) mm strip with and including necessary clamps, nut bolts laid in ground complete all as specified and directed.
Supply fixing and fabricating tray holding cross arms FI clamps support U clamps strips and back plates fabrication from structural steel section incl nut bolts washer bars etc of required size and thickness for supporting of cable tray by welding incl bending or welding cold or hot,drilling holes for bolt in any shape or size indicated and including of one finishing coat of black paint over a coat of primer complete to support the cables complete all as specified and directed.
S&F for connect lightening arrestor non linear, pole type MCOV 11 KV discharge capacity 65 KA, with all fittings suitable for 11 KV electric working pressure including strap, bolts, nuts and washers etc complete all as specified and directed.
Supply and laying of HT UG cable XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 11000 volts grade cross section area 95 Sqmm 3 core laid in trenches or fixing on panels/ walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts testing complete all as specified and directed. Note:- Excavation and earth work will be measured and paid separately.
Material & Labour for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed .
Material & Labour for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed .
M& L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 ( 11.00 Meters long) complete all as specified and directed . Note:- Excavation earth work & PCC will be measured and paid separately.
S&F for air break switch (GOD) vertical double break type triple pole mechanically operated mounted on double insulartors and steel frame with operating mechanism linked with ground level operating GI rod 25mm dia medium grade. GOD suitable for current rating upto 400 amps and suitable for HT 11 KV including connecting complete with locking arrangement complete all as specified and directed.
laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core laid in trenches or fixing on panels/ walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts testing complete all as specified and directed.
Supply, installation, testing and commissioning of new out door type LT feeder pillar box complete with 4 Nos heat shrinkable insulated copper bus bars of 600 Amp rating including all connections with busbar strip. Incoming :- (i) MCCB four pole 415 volts, 50 Hz, 350 Amps, breaking capacity 36 KA with adjustable thermal & adjustable magnatic protection release = 01No (ii) Phase indicator lamp RBY complete with copper control wiring = 01 set of three, (iii) Panel mounted multifunctional digital meter 3 lines LCD display in 96x96 Sqmm flush mounted case accuracy class-I. complete with all accessories including 3 Nos 400/5A CT for each phase . Outgoing :- (i) MCCB FP 415 volts, 250 Amps, breaking capacity 25 KA with adjustable thermal adjustable magnetic protection release = 01 Nos. (ii) MCCB FP 415 volts, 160 Amps, breaking capacity 16 KA with adjustable thermal adjustable magnetic protection release = 03 Nos.
Supply, installation, testing and commissioning of new out door type LT feeder pillar box complete with 4 Nos heat shrinkable insulated copper bus bars of 300 Amp rating including all connections with busbar strip. Incoming :- (i) MCCB four pole 415 volts, 50 Hz, 160 Amps, breaking capacity 25 KA with adjustable thermal & adjustable magnatic protection release = 01No (ii) Phase indicator lamp RBY complete with copper control wiring = 01 set of three, (iii) Panel mounted multifunctional digital meter 3 lines LCD display in 96x96 Sqmm flush mounted case accuracy class-I. complete with all accessories including 3 Nos 200/5A CT for each phase . Outgoing :- (i) MCCB FP 415 volts, 63 Amps, breaking capacity 16 KA with adjustable thermal adjustable magnetic protection release = 04 Nos.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed.
Excavation of hard/dense soil in trenches not exc. 1.5 m wide and not exec 1.5 mtr in deep for foundation etc.or for shafts,wells,cesspits,mainholes,pierholes etc.in any type of soil for foundation and getting out and levelling of bottom surface to required level all as specified and directed .
Excavation hard/dense soil in trenches not exceeding 1.5 mtr wide and depth beyond the first 1.5 mtr for foundation ect. Or for shafts, well, cesspits, mainholes ect. In any type of soil for foundation and getting out and levelling of bottom surface to required level all as specified and directed by engineer-in-charge
Material and labour for river washed and screened ,dry sand for filling in trenches/sub stations below and around underground cables for cushioning of cables etc complete all as specified.
Returning filling including leveling,watering and well ramming soil in layers not exceeding 25cm complete all as specified and as directed by the Engineer - in - Charge.
Removing the excavated materials not exceeding 50 m and depositing where directed at level exceeding 1.5 m above the starting level complete all as specified and directed .
Supplying and laying unreinforced precast cement concrete cable covers, Class HV, Type- 1, Flat, size 300 mm x 180 mm x 40 mm in trenches for cable protection, embossed with "HT ELECTRIC" on the top surface complete all as specified and directed .
Supplying and laying unreinforced precast cement concrete cable covers, Class LV, Type- 1, Flat, size 250 mm x 150 mm x 40 mm in trenches for cable protection, embossed with "LT ELECTRIC" on the top surface complete all as specified and directed .
S & F for Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregrate) of size 900 x 300x 100 mm thick with "DANGER / 11 KV CABLE /MES or DANGER/ 11 KV HT JOINT/ MES" embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work as required complete all as specified and directed.
S & F for Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregrate) of size 900 x 300x 100 mm thick with "DANGER LT CABLE " embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work as required complete all as specified and directed.
M&L for trenchless boring under road crossing/foot paths etc complete all as specified and directed .
Supply and laying in replacement of GI pipe 80 mm bore,Light grade for cable protection ISI marked complete all as specified and directed.
M & L for Cement Concrete PCC 1:4:8 (40 mm graded aggregate), type D2 as concrete in foundation of Poles and filling and mass concrete etc, including formwork (as if required), complete all as specified and directed.
M & L for Cement Concrete PCC 1:3:6 (20 mm graded aggregate) type C1 as in coping of pole etc including form work and finishing the surfaces even and smooth with out using extra cement complete all as specified and directed.
M&Lfor Danger notice plate of 1.6 mm thick mild steel sheet ,vitreous enamelled white,with letters, figures and conventional skulll and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT, 25 x 20 cm complete all as specified and directed .
Raj Construction
ASSOCIATED BUILDCON LLP
B.K. ROY & SONS
Excel Enterprises
M/S SHRI SHYAM BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .