Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹17.1 L+₹2.3 L (15.7%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | GLOBAL AQUATECH L2 | M/s VISHWAMITRA WATER TECHNOLOGIES PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing and Commissioning of Bar Screen (SS-304 corrugated Perorated screen) inside the Bar Screen Chamber required for screening of floatable matter of sewage and effluent having max. Flow 0.2m3/hr with mesh size of 10mm. with suitable handling arrangement. | 1 | job | 8,000 ₹8,000 | 4,500 ₹4,500 Lowest |
| 2.00 | Construction of RCC Bar Screen Chamber at starting of ETP to hold bar screen for handling max flow is 0.5 m3/hr and having Concrete grade : M- 25. | 1 | job | 12,000 ₹12,000 Lowest | 20,000 ₹20,000 |
| 3.00 | Construction of RCC oil & Grease chamber located after Bar Screen Chamber to separate oil and grease from sewage and effluent handling max. flow 0.5 m3/hr. Concrete grade : M- 25 | 1 | job | 16,000 ₹16,000 Lowest | 20,000 ₹20,000 |
| 4.00 | Construction/Providing & fitting of Collection cum Equalization Tank (with grit chamber and top slab + Platform) required to store effluent for uniform quality and continuous feeding for collecting effluent water 5 m3. , Concrete Grade : M-25 | 1 | job | 75,000 ₹75,000 Lowest | 95,000 ₹95,000 |
| 5.00 | Supply, installation, testing and commissioning of RCC Sludge Drying Bed 2 nos. located after Tube Settler Tank for drying the sludge of capacity 1 m3, Concrete grade : M- 20 | 1 | job | 20,000 ₹20,000 Lowest | 40,000 ₹40,000 |
| 6.00 | Providing & fitting of Primary Settling Tank having MSFRP with 5 mm sheet thickness + 2 mm FRP coating of side walls and 6 mm thickens of bottom + 2mm FRP coarting on bottom. Located after the equalization tank for sedimentation of coagulants and flocculants. Primary settling tank having capacity is 0.8 m3/hr. | 1 | job | 1,20,000 ₹1,20,000 | 1,00,000 ₹1,00,000 Lowest |
| 7.00 | Providing & fitting of Aeration Tank (MBBR Tank) having MSFRP with 5 mm sheet thickness + 2 mm FRP coating of side walls and 6 mm thickens of bottom + 2 mm FRP coating on bottom and located after Primary settling tank to mix air for aerobic Biological treatment. Capacity of MBBR Tanks is 1.2 m3 /hr . | 1 | job | 1,75,000 ₹1,75,000 | 1,25,000 ₹1,25,000 Lowest |
| 8.00 | Providing & fitting of secondary tube settler tanks having MSFRP with 5 mm sheet thickness of side walls and 6 mm thickens of bottom and located after MBBR tanks and it is used for settlement of the MLSS. Capacity of Secondary tube settler Tanks is 0.8 m3. | 1 | job | 1,25,000 ₹1,25,000 | 1,00,000 ₹1,00,000 Lowest |
| 9.00 | Supply of MBBR media. MOC –PP , Flower type with UV stabilize , Size : 150 mm. | 1 | job | 18,000 ₹18,000 | 15,000 ₹15,000 Lowest |
| 10.00 | Supply and fittings of Primary and Secondary tube settler media, MOC – PP, UV stabilized , Quantity : 3.0 m3 . Size : Height – 700 mm , UV stabilized. | 1 | job | 35,000 ₹35,000 | 25,000 ₹25,000 Lowest |
Tender Value
₹19.9 L
EMD Value
₹40,000
Closing Date
9 Feb 2026, 4:00 pmClosed
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
Design, Supply, Installation, Testing and Commissioning of 5 KLD Effluent Treatment Plant ETP with other allied works at SDH Jagti, Jammu
2026_PWDJK_301068_1
MHDJ/e-NIT 331 of 2025-26
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
60 days
SDH Jagti
as per e nit
2 documents required · 2 mandatory
₹1,000
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
₹40,000
18 Mar 2026
21 Jan 2026
10 Feb 2026
21 Jan 2026
9 Feb 2026
27 Jan 2026
21 Jan 2026 - 2 Feb 2026
Supply, Installation, Testing and Commissioning of Bar Screen (SS-304 corrugated Perorated screen) inside the Bar Screen Chamber required for screening of floatable matter of sewage and effluent having max. Flow 0.2m3/hr with mesh size of 10mm. with suitable handling arrangement.
Construction of RCC Bar Screen Chamber at starting of ETP to hold bar screen for handling max flow is 0.5 m3/hr and having Concrete grade : M- 25.
Construction of RCC oil & Grease chamber located after Bar Screen Chamber to separate oil and grease from sewage and effluent handling max. flow 0.5 m3/hr. Concrete grade : M- 25
Construction/Providing & fitting of Collection cum Equalization Tank (with grit chamber and top slab + Platform) required to store effluent for uniform quality and continuous feeding for collecting effluent water 5 m3. , Concrete Grade : M-25
Supply, installation, testing and commissioning of RCC Sludge Drying Bed 2 nos. located after Tube Settler Tank for drying the sludge of capacity 1 m3, Concrete grade : M- 20
Providing & fitting of Primary Settling Tank having MSFRP with 5 mm sheet thickness + 2 mm FRP coating of side walls and 6 mm thickens of bottom + 2mm FRP coarting on bottom. Located after the equalization tank for sedimentation of coagulants and flocculants. Primary settling tank having capacity is 0.8 m3/hr.
Providing & fitting of Aeration Tank (MBBR Tank) having MSFRP with 5 mm sheet thickness + 2 mm FRP coating of side walls and 6 mm thickens of bottom + 2 mm FRP coating on bottom and located after Primary settling tank to mix air for aerobic Biological treatment. Capacity of MBBR Tanks is 1.2 m3 /hr .
Providing & fitting of secondary tube settler tanks having MSFRP with 5 mm sheet thickness of side walls and 6 mm thickens of bottom and located after MBBR tanks and it is used for settlement of the MLSS. Capacity of Secondary tube settler Tanks is 0.8 m3.
Supply of MBBR media. MOC –PP , Flower type with UV stabilize , Size : 150 mm.
Supply and fittings of Primary and Secondary tube settler media, MOC – PP, UV stabilized , Quantity : 3.0 m3 . Size : Height – 700 mm , UV stabilized.
Supply of Microbial culture for commission and bacterial growth aeration tank, Concentrated with Microbial stains in powder form. Quantity: 60 kg. EM Solution: 50 kg, Hypo chlorite: 50 kg Preparation of jiggery – 2 kg and DAP in warm water.
Supply, Installation, Testing and Commissioning Semi-Automatic Pressure sand filter of size: Diameter: 10 inches and Height: 54 inches. MOC - FRP fitted with MS supporting Frame structure.
Supply, Installation, Testing and Commissioning Semi-Automatic Activated carbon filter of size: Diameter: 10 inches and Height: 54 inches. MOC - FRP fitted with MS supporting Frame structure. ID – 900 vales carbon used only.
Supply, Installation, Testing and Commissioning of clear water tank. MOC - PVC, Three layer located after Activated carbon filter.Capacity: 0.5 m3.
Supply, Installation, Testing and Commissioning of Effluent Transfer Pump (1 Working + 1 Standby) having discharge 0.5 m3/hr and head 8m non clog self primping type located after at the top slab of equalization tank to transfer raw effluent to coagulation tank.
Supply, Installation, Testing and Commissioning of Air Blowers 2 Nos. 1 HP (1W+1S) located near the aeration tank to supply air at the rate of 20m3/hr at a pressure of 0.4 Kg/cm3 for mixing purpose
Supply, Installation, Testing and Commissioning of Air Blowers Motor 1 HP - 2 Nos. (1W+1S)for the Air blowers.
Supply, Installation, Testing and Commissioning of Aeration Grid ( MS B-class air grid of air blower and MS B class air grid located inside MBBR Tank for transfer diffused air through Fine diffusers.
Supply, Installation, Testing and Commissioning of Silicon Coarse and Fine Membrane Air Diffusers tubular silicon type located inside collection and aeration Tank for transfer of air to Equalization, Chemical mixing and aeration tank.
Supply, Installation, Testing and Commissioning of Dosing Tanks (HDPE) 3Nos. located near Flocculation and Chemical reaction tank for storage of chemical solution of capacity 25 liters each.
Supply, Installation, Testing and Commissioning of Dosing Pumps- 3 Nos. located near Chemical reaction tank for dosing chemical of capacity 0-5 LPH each.
Supply, Installation, Testing and Commissioning of Electromagnetic Flow meter located at inlet and outlet of plant. Flow meter should be digital type with totalizer system.
Supply, Installation, Testing and Commissioning of Filter Feed Pump (1 Working + 1 Standby) having discharge 0.5m3/hr and head 10m centrifugal, self-primping type located near to filtration system.
Supply, Installation, Testing and Commissioning of Centralize Electrical Control Panel. Control panel will be industrial cubical type, with non-compartment, dust and vermin proof, wall mounted. One incoming feeder will be provided which will have amp meter, voltmeter, indicating lamps and energy meter. Outgoing feeders will be as per drives of mechanical equipment. Outgoing feeder shall have contactor, overload relay, on/off push button, indicating lamp, neutral link and one set of terminal block. Panel will be made of CRCA Sheet 2 mm thickness, powder coated. Job includes copper plate earthing of the panel and other electrical items.
Providing and fitting of Wires, Cables and GI Cable Trays, earthling etc
Supply, Installation and fitting MS supporting system i: e Ladder, Hand rail MS Platform supporting system with Platform railing and Pumps and motors covers.
Providing and safe storing of chemical (Alum, Polyelectrolyte, Lime and Hypo chlorite).
Providing and fitting of Complete Pipes and Fittings such as tees, crosses, plugs, sockets, elbows, reducers, supports & clamps and other allied accessories.
Supply, Installation, Testing and Commissioning of Sludge Disposal Pump 2 No’s Centrifugal type of discharge 0.5m3/hr and head 5m
Providing and fitting of allied Accessories such as Pressure gauges, Level switches etc.
Providing/ Laying of heavy duty fire resistant electric wire armored aluminium cable size 35 sq mm 3.5 core from hospital main supply to control panel as per site condition and further to Effluent Treatment plant of required size along with multi stranded Aluminium/ copper conductor free from any joints including jointing material such as crimping type lugs, brass cable glands etc for making connection with machinery. Complete work shall be on turnkey basis. Any other relevant equipment/Accessories which has not been covered earlier but is required for proper installation testing and commissioning of Effluent Treatment Plant shall also be covered within the scope of work.
Providing and fitting of UPVC of 75 mm dia, 80mtr in length for connecting the source of infectious waste water from Laboratories to collection tank then the collection to the municipal drains along with bends sockets and all fittings and manhole of size (600x450)mm 5nos along the pipeline by way of earth work in excavation by manual means in trenches for foundation drains for laying of PVC pipes and then filling the earth in trenches, plinth, sides of foundation etc in layers, consolidating each deposited layer by ramming and watering. Complete job includes cost of material excavation of trenches, restoration of excavated earth and labour charges.
Providing and fixing precoatedgalvanised iron profile sheet shed for ETP plant at site, (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
CAMC of 5KLD ETP Plant including Chemicals, Alum, Poly, Caustic and Hypo chlorine (three Years) (AFTER WARRANTY PERIOD)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
BOQ_976801.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .