| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹30.0 L+₹56,378.50 (1.92%)Rejected-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹35.1 L+₹5.7 L (19.4%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
1 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer(N) Mamun
Garrison Engineer(N) Mamun
REPAIR/ MAINTENANCE/ REPLACEMENT OF LT U/G CABLES, OVERHEAD LINES, POLES, JOINTS AND CONNECTED ITEMS AND E/M WORK IN INSTALLATIONS AT D-IA ZONE, D-III ZONE, D-IV ZONE AND MAP BHASKER AREA UNDER AGE E/M -I OF GE (N) MAMUN
2022_MES_549878_1
GE(N)/M-14/2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹88,000
24 Nov 2022
5 Sept 2022
3 Oct 2022
5 Sept 2022
1 Oct 2022
19 Sept 2022
60 days
Amount
Dismantling aluminium conductor of LT OH line after unbinding from insulators for replacement /re-stringing of damaged conductors including seggregating serviceable/unserviceable conductors for re-use or for shifting to MES store for taking credit to contractor complete all as specified and directed.
Restringing of dismantled aluminium conductor on LT OH line with new aluminium binding wire including stretching with 3% sag, re-connecting of all cables disconnected jumpers with proper jointing with binding wire complete all as specified and directed.
M&L ACSR of LT OH line including securing with insulators using aluminium binding wire, jointing jumpers etc including all disconnected cables, jumpers with proper binding complete all as specified and directed.
Dismantling earth wire from LT OH line after unbinding from pole for re-use or for shifting to MES store for taking credit to contractor complete all as specified and directed.
Restringing and restretching dismantled earth wire from LT OH line including securing with insulators using GI binding wire complete all as specified and directed.
M&L for Galvanised steel earth wire of service feeder or distributor span of street light polesincluding binding with insulators using GI binding wire, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc from LT poles complete and setting aside for re-use or shifting to MES store for taking credit to contractor complete all as specified and directed.
Fixing only the cross arms items with supports/ angle iron frame etc incl nut, bolt, washer, welding, bending, hot or cold drilling holes for insulators bolts in any size or shape complete all as specified and directed.
Material and labour for replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed ,welding and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Demolition of concrete of stay assembly, Dismantling and taking old/UNSV stay assembly including Stay wire and insulator complete all as specified and directed.
M&L for replacement stay assembly complete with MS stay plate of size 300x300x6mm thick, stay rod 20 mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I, 2009 ( Excavation, PCC, saty wire and loop type insulators will be measured separately) complete all as specified and directed.
M&L in replacmement galvanized stay strand of 7/4mm size complete all as specified and directed.
M&L loop type insulator large size with overall dimensions (90 x140) mm with clearance of hole 25.5 mm vitreous white brown or green complete all as specified and directed.
Dismantling insulators of any type, any size complete all as specified and directed.
Fixing only shackle type insulators complete all as specified and directed.
Fixing only pin type insulators complete all as specified and directed.
M&L shackle type insulator,100 mm height,115 mm dia, 31x5 mm strap,14 mm dia bolts Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, as under: complete all as specified and directed.
M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and directed.
Dismantling old unserviceable concrete pole/Strut any size and shifting n.exceeding 50 meters for setting aside for disposal action all as specified and directed.
Material and labour for prestressed cement concrete pole 9 mtr long, 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class-10 complete, erected truly in vertical position and painting the poles with alternate layer of 30 cm, black and yellow paint with synthetic enamel paint upto 1.5 mtr above from the coping complete all as specified and directed.
Taking out LT cable,1100 volts grade heavy duty aluminium conductor of size upto 25 Sqmm from trench/cable duct/through wall/pole carefully, removing defective length, stacking aside for re use or for taking credit to contractor all as specified and directed. Note: Excavation and other earth work shall be measured and paid seperately under relevant item.
All as per Srl Item 21 here in above but of size 35 Sqmm
All as per Srl Item 21 here in above but of size 50 Sqmm to 95 Sqmm
All as per Srl Item 21 here in above but of size 120 Sqmm to 185 Sqmm
All as per Srl Item 21 here in above but of size 240 Sqmm to 300 Sqmm
Laying only cable of size up to 25 sqmm all as specified and directed.
Laying only cable of size 35 sqmm all as specified and directed.
Laying only cable of size 50 to 95 sqmm all as specified and directed.
Laying only cable of size 120 to 185 sqmm all as specified and directed.
Laying only cable of size 240 to 300 sqmm all as specified and directed.
Supply, laying, connecting and testing in replacement XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 300 Sqmm 3.5 core with aluminium termination lugs, laid in trench/cable duct/through wall/pole and making good disturbed surface complete all as specified and directed.
All as above mentioned in item No 31 but Size 240 sqmm 3.5 core
All as above mentioned in item No 31 but Size 185 sqmm 3.5 core
All as above mentioned in item No 31 but Size 150 sqmm 3.5 core
All as above mentioned in item No 31 but Size 120 sqmm 3.5 core
All as above mentioned in item No 31 but Size 95 sqmm 3.5 core
All as above mentioned in item No 31 but Size 70 sqmm 3.5 core
All as above mentioned in item No 31 but Size 50 sqmm 3.5 core
All as above mentioned in item No 31 but Size 35 sqmm 3.5 core
All as above mentioned in item No 31 but Size 25 sqmm 4.0 core
All as above mentioned in item No 31 but Size 16 sqmm 4 core
All as above mentioned in item No 31 but Size 10 sqmm 4 core
Supply and fixing in replacement of GI tubing, light grade 40 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed. (clamps for fixing pipe, nuts, bolts washers shall be measured separately )
All as mentioned in item No 43 but 50 mm bore
All as mentioned in item No 43 but 80 mm bore
All as mentioned in item No 43 but 100 mm bore
Excavating in trenches in soft / loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, trenches for laying of cable, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
All as mentioned in item No 47 here in above but n exc 1.5 m wide and exc 1.5 m and n exceeding 3.0 m in depth
Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required and directed.
Supply of fly ash bricks, laid dry in trenches over the cable adjoining each other widthwise for cable protection complete all as specified and as directed.
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick (total 23cm punned thicness) after laying of cable to trenches complete all as specified and directed.
Material and Labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregrate for foundation filling as mass concrete complete all as specified and directed.
Material and Labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregrate for coping of poles and foundation of stay including necessary form work complete all as specified and directed.
Supply and fixing in replacement street light mounting bracket ,fabricated to shape, made out of GI pipe, light grade as per LED street light fitting bore dia ,120 cm long for mounting on PCC/Steel poles incl 02 X MS flat iron clamps of 30x5mm size with nut, bolt, washers etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supply and fix junction box water proof outdoor type made out of SMC of exterenal dimensions 250 x 250 x 105 mm single door type hinged with locking arrangement front operated with one number MCB 06 Amps capacity for housing 3 phase and neutral busbar including connecting the incoming/outgoing cables including cable glands SMC coated clamps bolts and fixed to the existing poles with mild steel flat of size 25 mm x 4 mm duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F PVC multistranded copper cable three core of size 1.5sqmm for connection from junction box to security light with 20mm PVC condit pipe for protection of PVC copper cable complete all as specified and as directed.
M&L for Painting to steel tubular pole after sanded or scratched, priming the surface with redoxide primer and applying two coats of aluminium paint including writing pole No complete all as specified and directed.
Trimming up of tree branches upto 5 mtr all around LT overhead lines, removing cut branches from site as directed, Note :- (i) The overhead lines shall be kept clear from all trees by trimming of tree branches with 3 mtr all around the line. Necessary permission shall be obtained from department by contractor one day prior to trimming in particular area and shut down of that area shall be arranged by department. (ii) Distance between two LT poles shall be measured as one span for the purpose of payment, irrespective of the No of trees required to be trimed. (iii) Fortnightly inspection of lines shall be made jointly by contractor / his authorised rep and rep of Engr-in-Charge. Out come whether lines are free from tree branches or otherwise shall be kept on records for payment payment purposes. (iv) The OH line shall be maintained for whole period of contract. Payment of this item shall be made under final bill only. (v) The payment for the period for which line is not maintained shall be deducted proportionately based on fortnightly inspection carried out as detailed above.
Restretching ACSR, GI wire of LT OH line running on poles by means of pulling jack maintaining sag not more than 3% in each span including replacment all binding wires in between all span and on terminations including rejointing of all cable, jumper connection provided with new binding wire or jumpers complete all as specified and as directed.
M&L for Cable end jointing kit, heat shrinkable, 1100 volts grade complete with jointing material and accessories suitable for 2/3.5 core XLPE armoured aluminium conductor cable of size 10-16 sqmm size. Note: Cost of excavation and earth work, if required is deemed to be included in quoted rate.
All as mentioned in item No 62 but size of 25-50 sq mm, 3.5 core
All as mentioned in item No 62 but size of 70-150 sq mm, 3.5 core
All as mentioned in item No 62 but size of 185-300 sq mm, 3.5 core
Supplying and fixing in replacement 1100 volts grade heavy duty cable ,6 sq mm, 2 core,flat,PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed for service connections all as specified and directed.
All as per Srl item No 65 above but cable size10 sqmm 2.0 core .
Disconnecting all the electrical connections from transformer in any situation of any capacity i.e. Jumpers/cable from the cable end box or bushings & earthing terminal of the transformers and excavation work for shifting of cables including taking down transformer from platform and reinstallation after plasterering, pcc work, commissioning and testing complete all as specified and directed . Note: Plaster work,cement concrete,excavation in post,post and struts, welded steel wire febric fence, bolts,nuts and painting of fence will be measured and paid separately under respective items.
Taking down cement plaster from transformer plateform on brick walls or stone walls any descrition etc including raking out joingts, hacking for key, scrubbing down with water etc all as specified and directed.
M&L 15mm thick cement plasters in CM 1:4 on concrete or brick wall surfacesfinished even & smooth with out using extra cement all as specified and directed
Demolition of cement concrete from transformer plateform n.exc 15cm thick below or above ground level all as specified and directed
M&L for cement concrete type B-2 (1:2:4) using 40 mm graded stone aggregate as in flooring all as specified and directed.
M&L of two coats of cement base paint on newly plastered surface incl preparation of surface of new wall complete all as specified and directed.
M&L preparation of old painted surface of walls and applying one coat of cement base complete all as specified and directed.
M&L for excavation in post holes each n.exc 0.50 cum for transformer plateform perimeter fence and getting out any type of soil, returning filling and ramming and removing excavated soil to a distance n.exc 50m all as specified and directed
Material and Labour for PCC 1:2:4 type B2 using 40 mm graded stone aggregrate for foudation , filling and mass concrete complete all as specified and directed.
Dismantling of strutural steel work complete all as specified and directed.
S&F posts and struts in fencing from transformer plateform including cutting tops to shape as directed drilling holes, notching for wire etc iron fillets including all necessary drilling bolting etc and similar work and confirming to Fe-410-0, Fe-310-0 all as specified and directed
Dismantling of fencing wire mesh any type complete all as specified and directed.
M & L for welded steel wire febric of size 25mm x 25mm (weight of mesh n exc 4kg/sqm) for transformer plateform fence incl cutting in shape and size and welding in transformer plateform iron frames all as specified and directed
S&F mild steel bolts machine made with hexagonal or square head one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square n.exc 30cm long dia n.exc 10mm all as specified and directed.
Labour for cutting,bushing,levelling the area around E/M installation ,substations,pole struture etc including surface excavation not exceeding 30cm deep and average 15cm deep and getting out roots etc and removing from site not less than 50 mtr and surface dressing all as specified and directed.
M&L hardcore of guage n exc.63mm ,deposited,spread and levelled in layers nexc.15cm thick around electrical substation or electrical structures including levelling ground after removing debris , rubbish prior to laying gravels complete all as specified and directed.
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of earth plate not less than 1.5 meters below ground level connected by 32 X6 mm GI strip as earth lead by means of GI nuts and bolt,check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20 mm graded stone aggregate,with fair finish,internal dimension of concrete chamber shall be 300x300x300 mm size duly plastered with 15 mm thick CM 1:4,funnel with wire guage mesh, 10 mm thick CI pit cover hinged with CI frame.earth plate surrounded by charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part -1 (2009) and specified including provision of GI strip upto 7.5 metre long protected by 40 mm dia medium grade pipe and watering pipe shall be 20 mm bore medium grade ,including all excavation , earth work and connecting the strip to test point/panel as specified and testing on completion complete all as specified and directed. Note:Cost of strip exceeding 7.5 meter shall be measured and paid seperately
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of earth plate not less than 1.5 meters below ground level connected by 25X4 mm GI strip as earth lead by means of nuts and bolt,thimbles, check nuts, washers of GI or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20 mm graded stone aggregate,with fair finish,internal surface of concrete chamber shall be given internal dia 300mm x 300 mm dia,15 mm thick plaster in CM 1:4 funnel with wire guage mesh ,80 mm thick RCC pit cover 320mm x 320 mm of RCC 1:2:4 Type B1 using 20 mm graded stone aggregate reinforced with XPM jelly and charcoal ,dust and common salt all as shown in electrical plate No 5 of MES SSR Part -1 (1991) and specified including provision of GI strip upto 7.5 metre long protected by 40 mm dia medium grade pipe and watering pipe shall be 20 mm bore medium grade ,including all excavation and earth work and connecting the earthing to an earthing test point and to main switch board as specified and testing on completion complete all as specified and directed. Note: RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 kg/Sqm in lieu of CI cover.
Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connecting to Galvanized earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth lead protected by provision of GI medium grade pipe 15mm bore dia including 40mm thick cover of RCC (1:2:4) Type B-1 (using 20mm graded crushed stone Aggregate) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made of shape, GI medium grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangements, funnel, wire mesh and earth work in any type of soil including returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I (specificetion) and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and as directed.
Deduct Total amount of SCHEDUL 'A' SECTION-II (SCH OF CREDIT) Rs 2,02,818.50 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .