Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC M 134 BARAMUNDA BHUBANESWAR BHUBANESWAR 751003 | BHUBANESWAR | BHUBANESWAR | ODISHA | 751003 | L1 | Accepted-AOC technocommercially eligible L1 bidder | |
| 2 | L2₹9.9 L+₹992.59 (0.10%)Rejected-Finance ADHANGAGARH ANAKHIA AT PO JAGATSINGHPUR 754102 | JAGATSINGHAPUR | ODISHA | 754102 | L2 | Rejected-Finance REJECTED FOR NOT BEING L1 | |
| 3 | L3₹14.4 L+₹4.5 L (46.0%)Rejected-Finance 4005 4TH FLOOR SKYLINE NEAR KADRU OVERBRIDGE KADRU RANCHI PIN 834008 | RANCHI | RANCHI | JHARKHAND | 834008 | L3 | Rejected-Finance REJECTED FOR NOT BEING L1 |
Tender Value
₹17.9 L
EMD Value
₹22,400
Closing Date
25 Sept 2024, 5:00 pmClosed
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Overhauling and Periodic Maintenance of Power Transformers by filtration of insulating minerals OIL, Testing of OIL and painting of transformers currently in Operation stage at 132-33 KV Nandira Grid Sub-Station and 33-11KV Sub-stations under JA.
2024_MCL_317346_1
GM(JA)/EnM/e-Tender/24-25/ E-687/52 DTD. 12/09/2024
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
Nandira and Balanda Substation, Talcher
AS PER NIT
5 documents required · 5 mandatory
₹22,400
21 Jan 2025
12 Sept 2024
27 Sept 2024
13 Sept 2024
25 Sept 2024
13 Sept 2024
13 Sept 2024 - 18 Sept 2024
Amount
Filtration of Transformer OIL with applying Vaccum & Heat to achieve BDV Value of 60KV & maintain the properties of OIL In Compliance to IS 1866:2000 .
Painting of Transformers by Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Supply ,Fittings, Connection & commissioning of OTI/WTI Indicator with sensing bulb, 4 switches & 03 mtr capilary length.
Supply ,Fittings, Connection & commissioning of 36KV/630A Porcelin Bushing with clamps, Bolts & Nuts
Supply ,Fittings, Connection & commissioning of 12KV/630A Porcelin Bushing with clamps, Bolts & Nuts
Supply ,Fittings, Connection & commissioning of Brass Studs with Nuts for HV/ LV Bushings
Supplying & Fittings of Slica Gel Breather as per Sample provided at Site.
Comprehensive Power Transformer Testing of 40MVA,132/33 KV, MAKE: BBL Transformer with SFRA TEST.
Comprehensive Power Transformer Testing of 40MVA,132/33 KV, MAKE: BBL Transformer with Tan-Delta test of Bushing & HV/LV Winding of Transformers.
Comprehensive Power Transformer Testing of 40MVA,132/33 KV, MAKE: BBL Transformer with following Tests. * Winding Resistance Test * Turn Ratio Test. IR Test PI Test Vector Group Test Open Circuit Test Short-Circuit Test Voltage ratio Test Magnetic Balance Test Auxiliary Protection check (WTI, OTI, Buchholz, PRV)
Testing of Dissolved Gas Analysis(DGA) of Transformer oil two samples (both bottom and Top) oil by a standard Lab including supplying of sample collecting container, manpower, machine, equipments as per requirement and standard In Complinace of Testing of Transformer Oil as per specification IS 1866-2000 and IS335-1993
Testing of Dielectric Dissipation Factor(Tand Delta) at 90° Centigrade, of Transformer oil by a standard Lab including suppling of sample container, manpower, machine, equipments at site as per the standard and requirement. In Complinace of Testing of Transformer Oil as per specification IS 1866-2000 and IS335-1993
Testing of Water content(Moisture) in PPM of Transformer oil by a standard Lab including suppling of sample container, manpower, machine, equipments at site as per the standard and requirement. In Complinace of Testing of Transformer Oil as per specification IS 1866-2000 and IS335-1993
Testing of Neutralization Value(Total acidic value in mg KOH/gm) of Transformer oil by a standard Lab including suppling of sample container, manpower, machine, equipments at site as per the standard and requirement. In Complinace of Testing of Transformer Oil as per specification IS 1866-2000 and IS335-1993
Testing of Flash point (in °C) of Transformer oil by a standard Lab including suppling of sample container, manpower, machine, equipments at site as per the standard and requirement. In Complinace of Testing of Transformer Oil as per specification IS 1866-2000 and IS335-1993
Testing of Interfacial tension (in N/m) of Transformer oil by a standard Lab including suppling of sample container, manpower, machine, equipments at site as per the standard and requirement. In Complinace of Testing of Transformer Oil as per specification IS 1866-2000 and IS335-1993
Testing of Specific Resistance in Ohm-cm at 90°c, of Transformer oil by a standard Lab including suppling of sample container, manpower, machine, equipments at site as per the standard and requirement. In Complinace of Testing of Transformer Oil as per specification IS 1866-2000 and IS335-1993
Supplying of Silicagel for Breathers.
Total impact of GST for the purpose of CTC
shivashakti services (BID ID -1089105)
ForenTec Engineers Pvt. Limited (BID ID -1089592)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .