| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹29.3 L+₹48,661.21 (1.69%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹29.7 L+₹90,756.65 (3.15%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹30.0 L+₹1.2 L (4.00%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹30.2 L+₹1.4 L (4.90%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
7 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SEVOKE ROAD
GE SEVOKE ROAD POST SALUGARA DIST JALPAIGURI
SPL REPAIR TO BLDG NO T 152 AND T 172 OF 52 AFVH AT SEVOKE UNDER GE SEVOKE ROAD
2022_MES_507857_1
GE/SEV/66 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE SEVOKE ROAD
₹56,000
Yes
28 Mar 2022
14 Feb 2022
9 Mar 2022
14 Feb 2022
7 Mar 2022
2 Mar 2022
15 Feb 2022 - 24 Feb 2022
60 days
Amount
Dismantling plain or corrugated steel sheeting any gauge or thickness as in roof covering complete all as specified and as directed.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550mpa as in roof covering/clading to wall, fixed with self taping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self drilling and self tapping screws, neoprene and limpet washers complete all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section in any position as in framed works complete all as specified and as directed.
S&F rolled mild steel section as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and duides for sliding doors; fixed with angle cleats or other connecting plates FE-290 Gde E-165.
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed
M&L for 20 mm thick screed bed or bedding layers for laying floor tiles etc in cement mortar 1:6 complete all as specified and directed.
M&L for 10 mm thick rendering in cement mortar 1:3 on other than fair face of brick work for laying tiles in vertical surfaces complete all as specified and directed.
M&L for Machine cut kota stone slab 18-20 mm thick laid and and jointed with grey cement slurry mixed with pigment to match the shape of the slab including cutting, washing,rubbing and polishing as in Floor complete all as specified and as directed.
All as per item No 09 above but as in skirting
Dismantling of wall and & ceiling boards (fiber,pilp, insulation,etc) or insulation boards/slabs/blankets any thickness, including cover fillets, complete as specified and directed.
S&F 605X605mm anodised aluminium snap grid frame work for false ceiling including 2.5mm dia mild steel wire galvanized class 3, @ 60cm centre to entre and fixed to steel or wooden member including 4mm thick non asbestos fibre cement boards fixed or laid/ inserted to aluminium frame work as in ceiling complete all as specified and directed. Note:- The size of aluminium main and croos tee shall be 40mm x25mm x2mm and size of angle shall be 25mm x 25mm x 2mm)
Taking down chowkats or frames with shutters(without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters(without taking off shutters from the frames) area not exceeding 1.50 Sqm each complete all as specified and directed.
S&F pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock, strick plate, etc Size of frame 125 x 60 mm including providing one shop coat of zinc chrome primer complete all as specified and directed.
S & F flush sutters, 30mm thick solid core contruction, with block board core and plywood face panels,commercial type on both sides complete all as specified and directed.
Supply and fixing IInd class hard wood factory made 35 mm thick glazed skelton shutters (three panel) open rebated and prepared to receive glass, gauge etc edges of framing, plain, chamfered or rounded, fitted with cut and mitred bends for securing glass/gauge etc, with sizes of members of shutters as specfied in para 8.24 (a) ;SSR 2009 (part-I) s complete all as specfied and directed.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) complete with clamps bolt not less than 16mm dia and fixing clip of sheet,cast or extruded section and fixing bolt of extruded section or cast aluminium alloy complete all as specified and directed.
S&F 300 mm dia ordinary rat tail rod pattern springs of mild steel including roller and roller plate for skeletton door shutter(having wire mesh) complete all as specified and as directed.
S&F aluminum anodized barrel tower bolts of extruded section, 200mm long, ISI marked, complete all as specified.
S&F aluminum anodized handle cast type , 150mm long, ISI marked, complete all as specified.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tined tacks, or galvanised wire stapless complete all as specified and as directed.
M&L for preparation new wooden surfaces of any description over 10cm width of grith and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, with glazing bars, dovetailed or welded including one shop coat of zinc chrome primer complete all as specified and directed.
All as per item No 24 hereinbefore but without glazing bars for gauzed shutter including providing one shop coat of zinc chrome primer complete all as specified and directed.
S&F mild steel square bar 12mm, in grill or guard bars welded to steel window all as specified and directed.
S&F 3mm thick sheet glass ordinary quality & glazing with oil putty in square not exc 0.50 Sqm in each pane complete all as specified and directed.
S&F Mild Steel flat iron fillets fixed to fly proof steel window shutters with screws or riveted for securing wiring gauze etc and as in wind ties for roof complete as specified and directed.
M&L for preparation old wooden surfaces of any description over 10cm width of grith and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces exceeding 10cm in width or girth complete all as specified and directed.
Demolition of cement concrete in ground floors and paving not exc. 15cm thick (below or above ground level) unreinforced complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D-2 (using 40mm graded mechanically crushed stone aggregate) as sub base of flooring complete all as specified and directed.
M&L for PCC (1:2:4) type B1 (using 20mm graded mechanically crushed stone aggregate) as in coping, bed plate, fillets and similar works includinng rounded or chamferred on edges with necessary form work complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified.
M&L for brick work with Fly Ash bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified.
M&L for brick work with sub class 'B' bricks straight or curved on plan any radius in half brick thick walls built in CM 1:4 complete all as specified.
Taking down cement plaster on brick wall/ceiling or concrete surfaces etc including racking out joints hacking for key scrubing down with water etc of any thickness including Dado of any description complete all as specified and directed.
M&L for 15mm thick rendering on other than fair faces of brick or concrete surfaces in CM 1:6 finshed even and smooth without using extra cement complete all as specified.
M&L for 20 mm thick rendering on fair face of brick work in CM 1:4 in two layers of 10mm each using water proofing compound in top layer only including finishing the surface even and fair(WPC shall be measured and paid seperately) complete all as specified and directed.
Supply only water proofing compound complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of weather resistance acrylic emulsion paint over a coat of primer complete all as specified and directed.
M&L for preparing of new plastered surface of walls and applying 1-2 mm thick wallcare putty complete all as specified and as directed.
S&F for curtain rod 25mm dia stainless steel with 02 Nos bracket and 02 Nos nobs complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire annealed, not less than 0.9mm dia or securing with clips complete all as specified.
S&F mild steel bars TMT 6 mm to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming to complete all as specified and as directed.
M&L for RCC 1:2:4 type BI (using 20 mm graded crushed stone aggregate) as in lintal, slab etc complete all as specified and as directed.
Demolition of reed, lathering, single of double, including battens and plaster or chicken wire lathering complete all as specified and as directed.
M&L for 75mm thick PCC (1:3:6) type D-2 (using 40mm graded mechanically crushed stone aggregate) as sub base of flooring complete all as specified and directed.
Taking down carefully old unserviceable copper/aluminium point wiring (light,Exchaust fan, socket or power) complete incl fittings such as switches,ceiling roses, pendents, regulators,bells,sockets,tube light fittings etc, and making good disturbed surface of walls & floors etc complete all as specified and as directed.
Taking down old unserviceable Main Switch, DB's consisting of MCBs wooden/GI/MS sheet board etc for kept in store and for later use all as directed.
Taking down carefully unserviceable sub main wiring of any size/core/type including making good the disturbed surfaces all as directed.
M&L for concealed point wiring with two single core PVC insulated, FRLSH unsheathed, multistranded copper conductor of size 1.5 sqmm and one single core PVC insulated FRLSH unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead in and including PVC rigid conduit (medium grade) with all fittings & accessories including MS sunk terminal box with 3mm thick hylum sheet top cover with screw & cup washers for one light / fan point / call bell complete. . Note: Cost of making good the disturbed surfaces (if any) & matching with the existing surface is deemed to be included in the quoted rate.
All as per Item Sl No -53 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor FRLSH of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor FRLSH of size 1.5 sqmm green in colour as earth lead for 5/6 A switch -socket point on independent board.
All as per Item Sl No -53 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor FRLSH of size 2.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor FRLSH of size 2.5 sqmm green in colour as earth lead for 15/16 A switch -socket point on independent board.
All as per Item Sl No -53 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor FRLSH of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor FRLSH of size 1.5 sqmm green in colour as earth lead for 5/6 A switch -socket point on same board.
M & L for Switch Socket combination 3 Pin, 5 Amp flush type universal, 240 volts, complete as directed.
M & L for Socket outlet 3 Pin, 5 Amp flush type universal, 240 volts, complete all as specified all as directed.
M & L for Switch Socket Combination 5 in 1, 3 pin, 5 and 15 Amp flush type universal, 240 volts, complete all as specified and as directed.
S&F piano switch single pole 5 Amp 230 Volt all as specified and as directed.
S&F ceiling rose ,surface bakelite 65mm x 50mm size with three terminals all specified and as directed.
Taking down existing u/s FTL light fitting and S&F in repair decorative box type 4 feet fitting with LED retrifit tue 20 watt with Aluminium extruded batten luminaire for 230 volt AC including LED tube 20 watt complete all as directed by EIC.
M&L LED street light of capacity 30 watt in Aluminium PDC housing, with IP66 protection including all accessories with frame and connection with PVC copper wire not exc 5 mtr complete all as specified and directed.
Taking down existing u/s FTL light fitting and S&F in repair decorative box type 2 feet fitting with LED retrifit tue 10 watt with Aluminium extruded batten luminaire for 230 volt AC including LED tube 10 watt complete all as directed by EIC.
Taking down ceiling fans/exhaust fan of any size,dismantling blades and removing fan and blades to MES store or as directed.
S&F energy efficient 5 star BLDC ceiling fan 230V, 1200 mm sweep without remote with all accessories and connecting up with the ceiling rose with required flexible wire of suitable size with ceiling fan complete all as specified and as directed.
S&F electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 sweep/1400 mm, 120 Watt complete.
S&F in repair exhaust fan AC, single phase, 230/240 V, of size 300 mm sweep steel/aluminium metal body with louvers including making holes on wall & making good the distrubed surfaces with all connecting arrangements complete all as specified and directed.
Supply & Fixing DB with sheet metal enclouser 240 volts, 12 way, with rated bus bar single pole &netural double door for MCB, including cutting chases for DB of reqd size and making good distrubed surface area complete all as specified and as directed.
Supply & Fixing MCB double pole (DP) 240 volts of capacity 32 Amp ,C curve, complete all as specified and as directed.
S&F MCB, SP, 10KA, 415V, "C" curve, 06-32 A, ISI Marked complete all as directed.
Supply & fixing TP&N DB 4 way with sheet metal enclosure 415 volts, double door rated bus bar for MCB including cutting chases exc 10cm but not exc 20 cm grith for DB and making good disturbed surface area complete all as specified and as directed.
S&F MCB TPN 63 AMP four pole 415 volt breaking capacity 16 KA adjustable thermal and adjustable magnatic complet all as specified and as directed.
Material and labour for concealed sub main wiring with two nos single core PVC insulated unsheathed multi strand copper conductor FRLS cable of size 6 sqmm and one no single core PVC insulated unsheathed multi strand copper conductor FRLS cable of size 6 sqmm as in continuous earth wire drawn into and including rigid non-metallic ISI marked PVC conduit medium grade with all fittings and fixings accessories complete all as specified and as directed.
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (in vertical position ) earth pit not less than 2.25 mtrs below normal ground level with the top edgeof the earth plate not less than 1.5 mtr (B.G.L.) & connected to galvanised iron wire 4 mm dia by means of bolts,nuts,checknuts & washer of galvanised iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation & earth work in any type of soil , 20 mm dia med grade galavinised steel tube for watering with one end fixed with cast iron funnel & wire mesh, 15 mm bore light grade galvanised steel tubing up to 7.5 mtr length for drawing earth lead including common salt , charcoal in alternate layers etc. complete all as shown in EP no 3 of SSR Part 1 & testing on complection incl taking down old unsv earthing complete.
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense type soil getting out and levelling of bottom surface to required level for cable/stay complete all as specified and directed
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Supply laying and trenches/wall LT UG XLPE insulated,armoured heavy duty electric cable with aluminoum conductor 1100 volts grade cross sectional area 16 sqmm 4 core including making necessary connections all as specified and directed.
Supply & laying in trenches clear sand for cushioning under cable 8 cm below and 15 cm above complete in level all as specified and directed by Engr-in-Charge. Note:- Punned thickness shall be measured.
Supply and laying burnt clay sub class B brick as cable protection all as specified and directed.
Supply and fix GI pipe 40mm medium grade for cable protection complete all as specified and as directed.
SRI SURAJIT SENGUPTA
M S ALOK SAHA
SHRI JIBANDHAN PAUL
SHRI JAYANTA GHOSH
LIBERAL ENGINEER CONSTRUCTION
M/S SUBRATA JOARDAR
PARTHA BISWAS AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .