| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | ₹35.1 L Quoted ₹35.5 L | L1 | Accepted-AOC Ok |
| 2 | L2₹35.9 L+₹45,828 (1.29%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | ₹35.9 L+₹45,828 (1.29%) | L2 | Rejected-Finance Other than lowest tenderer |
| 3 | L3₹43.0 L+₹7.5 L (21.2%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | ₹43.0 L+₹7.5 L (21.2%) | L3 | Rejected-Finance Other than lowest tenderer |
| 4 | Rejected-Technical 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | - | - | Rejected-Technical Rejected due to non submission of MOU |
| 5 | Rejected-Technical PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | - | - | Rejected-Technical Rejected due to non submission of MOU |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
18 Jan 2023, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
REPAIR/ REPLACEMENT OF VARIOUS PARTS OF VRF AC PLANTS, WATER SUPPLY, FIRE FIGHTING DG SET, TRANSFORMER AND MISC E/M WORKS AT NEW OPD COMPEX UNDER GE (E/M) BASE HOSPITAL DELHI CANTT-10
2022_MES_569978_1
GE/BH-94/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D Category b(i)
8 documents required · 8 mandatory
₹500
GE E/M BASE HOSPITAL DELHI CANTT
₹92,000
Yes
3 Mar 2023
19 Dec 2022
20 Jan 2023
19 Dec 2022
18 Jan 2023
4 Jan 2023
Amount
M&L for Repairs/ servicing/preventive and periodical maintenance to 750KVA DG set, installed at OPD Complex, with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as per recommended grade & quality and testing for smooth running at rated speed Testing and commissioning complete all as per manufacturer’s specification, all as specified and as directed. Note: (i) Major spare parts to be replaced in DG Set shall be Measured and paid for separately as "Supply only" under respective item of this Schedule. (ii) Coolant and Lub oil shall be measured and paid for separately under respective item of this Schedule.
Cleaning/ descaling of Radiator of 750KVA DG set
Supply only Kit fuel filter and ring Cat part No - KIT3238493
Supply only Element Lub oil filter Cat Part No - KIT 3238204
Supply only Kit Super BYP, Filter Element Cat No - kit No 3879488
Supply only Kit AIR Cleaner Element Cat Part No - Kit 3238665
S&F in replacement fuse base suitable for cylindrical/DIN type HRC/HBC fuse link type 630/400 A for AMF panel for 750 KVA DG Set complete all as as specified and as directed. Make : L&T Cat Part No SF94437 or Equivalent Model of Seimens/Schinder
S&F in replacement power contactor series CK- 3 pole, AC control 600 A, suitable for AMF panel of 750 KVA DG Set complete all as as specified and as directed. Make : L&T Cat Part No CK10CE311 or equivalent Model of Seimens/Schinder
S&F in repair Panel indicator 220 V for main ON/OFF indicator complete all as specified & directed. Make: L&T/Seimens/Legrand
S&F in repair single Phase Preventor as per sample complete all as specified & directed. Make : Minilec Model No VSP-2 or Equivalent Model of L&T/Seimens
S&F in repair Engine Starting Relay as per sample at site complete all as specified & directed. Make- Minilec/L&T/Seimens
S&F in repair On-Delay timer of 230 VAC, Range: 0 to 30 sec complete all as specified & directed. Make:L&T Cat No ST803280000 or equivalent Model of BCH/Seimens/Legrand
S&F in repair Under Voltage relay 240/415 Volt as per sample at site complete all as specified & directed. Make: L&T Cat No SL92720B000/SL92720D000 or Equivalent Model of BCH/Seimens/Legrand
Supply, laying & connecting in repair single core, copper conductor, PVC insulated, unsheathed, 1100 V grade (FRLS), 56/0.30, flexible, 4 Sqmm complete all as specified & directed.
Supply, laying & connecting in repair single core, copper conductor, PVC insulated, unsheathed, 1100 V grade (FRLS), 84/0.30, flexible, 6 Sqmm complete all as specified & directed.
Supply and Topping up inhibitor corrosion (Coolant), green/red, suitable for DG Sets 750 KVA capacity complete all as specified & directed. Make: Servo/IOC/HP/Castrol/BP
Supply and Topping up Lubricant oil 20W/40, multigrade, suitable for DG Sets 750 KVA capacity complete all as specified & directed. Make: Servo/IOC/HP/Castrol/BP
M&L for Maintenance & repairing of 1.1 KV, LT ACB panel including dusting, oiling, setting of over current and earth fault relay, if required, laid and servicing like all mechanical function including replacement of no volt coil tripping device complete all as specified and as directed.
M&L for repair to transformer 750 KVA, 11 KV at OPD complex to arrest oil leakage comprising of following operations complete all as specified and as directed:- (a) Disconnecting of transformer main supply input & output. (b) Opening up, top, cover, taking out transformer oil. (b) S&F in repair Porcelien LT 1.1 KV Brass rod & gasket (brass rod 40mm) - 04 Nos (c) S&F in repair Porcelien HT 11 KV Brass rod & gasket (brass rod 16mm) - 03 Nos (d) S&F in repair Silica Gel and Breather - 01 Nos (e) S&F in repair rubber cork sheet 3'x2'x6'mm - 01 No Note:- Transformer oil shall be measured and paid separately under respective item of this Schedule.
M&L in repair Insulation material for 750 KVA Transformer complete all as specified and as directed.
Labour for Removing oil leakage from terminal input/output, conservator top cover oil indicator, tab changer, bachhlotz relay (gasket Sheet) packing for 750 KVA Transformer complete all as specified and as directed.
M&L for comprehensive maintenance of 750 KVA -01, Nos Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and directed. Contract Details:- (i) Free maintenance and repair of Normal accessories (Spare Parts) .- 03 Nos Servo Voltage Stabilizer/ Servo Voltage Regulator. (ii) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (iii) Attending all complaints within 24 working hours. Note:- (a) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (b) Major Spares Part shall be measured and paid for separately under respective item of this Schedule as supply only. (c) Dismantling and removing of defective voltage stabilizer from 500 KVA to 500 KVA any size and capacity, removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's, Regulators, Condensors, Triac, Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load for testing completely all as specified and directed by the Engr-in-Charge.
Note: (i) Spare parts and winding coils as mentioned under respective items of schedule shall be measured and paid for separately as supply only. These shall be identical to those specified by original manufacturer. (ii) The job also incl. shifting through crane with necessary accessories & to and fro transportation from site to work shop and vise- versa.
Repair and rewinding of 600 amp (200x2)dimmer
Repair and rewinding buck/boost loading transformer cap. 600KVA.(each phase)
S/F cut off circuit with contractor cap 850 Amp TP.
S/F control wiring
S/F Power wiring and copper thimble
Input/output connection cap 750 Amp
S/F electronic control card. 750 KVA
S/F Amp meter (Digital) 750 KVA
S/F Synchronus motor 10kg torque. 500 KVA
S/F RC network. 750 KVA
M&L filtration and refilling of Transformer oil & alike for various equipment installed at OPD Complex through filtration machine to achieve required di-electric strength 50 kVA complete to entire satisfaction of Engr-in-Charge complete all as specified and as directed. Note:- (a) Quoted rate shall deemed to including testing of oil before filtration and after filtration of transformer, SVR & other equipment. (b) Result before filtration & after filtration of oil (Test Certificate) shall be submitted by the contractor to Engr-in- Charge.
Labour of Cleaning of fuel tank made of MS sheet of 750 KVA DG Set of 1000 Litre capacity approx, by draining out fuel in a separate container, taking out all silt/ dirt deposition inside the tank, cleaning it completely by manual labour and necessary T&P and refitting and connecting with fuel pipes with DG sets all as per site requirement complete all as specified and as directed.
S&F in repair battery, SMF, 12 Volt, 180AH capacity complete all as specified and as directed. Make Exide Express or equivalent Model of Luminous/Amara Raja/Okaya/Amron/Tata Green
S&F in repair battery charger suitable for 750 KVA DG set with charging capacity 48 Volt DC complete all as specified and as directed. Make:- TEKNIKA/Kirloskar/Exide
M&L for topping up of transformer oil for transformers/Voltage stabilizer installed at different location CGDA complete all as specified and as directed. Make:- SAVITA/IOC/ POWER/ Servo/HP/Castrol/BP
S&F in repair Fan belt suitable for 750/250/160 KVA DG Set complete all as specified and as directed.
S&F in repair fuel pipe set suitable for 750KVA, DG set complete all as specified and directed.
M&L in repair Cable jointing kit for 11 KV (Earthed) grade cable, suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm, for outdoor termination, heat shrink type joint, with jointing material and accessories complete all as specified and directed.
M&L in repair Cable jointing kit for 11 KV (Earthed) grade cable, suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm, for indoor termination, heat shrink type joint, with jointing material and accessories complete all as specified and directed.
Supply, laying and connecting in repair 6 Sqmm, 2 Core XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, LT UG electric cable with stranded aluminium conductor including lugs, glands etc, laid in trenches or fixed on wall or drawn through in GI pipe complete all as specified and as directed.
Supply, laying and connecting in repair 10 Sqmm, 2 Core XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, LT UG electric cable with stranded aluminium conductor including lugs, glands etc, laid in trenches or fixed on wall or drawn through in GI pipe complete all as specified and as directed.
Supply, laying and connecting in repair 25 Sqmm, 3.5 Core XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, LT UG electric cable with stranded aluminium conductor including lugs, glands etc, laid in trenches or fixed on wall or drawn through in GI pipe complete all as specified and as directed.
Disconnection of terminal of LT cable and locating, pin point fault in LT cable 1100V grade of any size including to & pro hire charge of special T&P complete all as specified and as directed.
Disconnection of terminal of HT cable and locating, pin point fault in HT cable 11000V grade of any size including to & pro hire charge of special T&P complete all as specified and as directed.
S&F in repair single phase under voltage relay 20-110V AC/DC CT Secondary 5A complete all as specified and as directed. Make L&T Cat Part No MV12AA00X00 or equivalent Model of Seimens/Schinder or any other Make mentioned in PS.
S&F in repair 3 Phase over current, earth fault relay 20-110V AC/DC 4 No programmable complete all as specified and as directed. Make L&T Cat Part No MC31AAXX000 or equivalent Model of Seimens/Schinder or any other Make mentioned in PS.
S&F in repair 3 Phase over current , earth fault relay 20-110V AC/DC CT Secondary 5A complete all as specified and as directed. Make L&T Cat Part No MRP11A50X00 or equivalent Model of Seimens/Schinder or any other Make mentioned in PS.
Supply in Repair Hand Gloves seamless suitable for working preasure 1100 Volts and tested up to 11000 Volts complete all as specified and as directed.
S&F in repair Fuel indicator Flexi pipe external DHPP 'N' tank for suitable DG Set length of flexiable pipe as existing complete all as specified and as directed.
M&L dewatering, cleaning of Water reservoir, 100000 Litre capacity, with high pressure jet to remove all mosses, algae and dirt and removal of dirty water alongwith sludge machines/ industrial vacuum cleaners and disposal of the same at safe distance including scrubbing of internal surface by steel wire brushing, removing the dirt completely using industrial vacumm cleaner and sterilizing the complete internal surface of the tank by using ISI mark, grade I, bleaching powder and marking the date of cleaning using synthetic enamel paint in white colour over black background in six stages cleaning process, as specified here in after complete all as specified and as directed:- (i) Dewatering the tank with portable submersible pump set with flow rate of 30,000 Litres per Hour. (ii) Removal of left over dirty water and sludge with special sludge removal pump set having capacity up to 1.7 lakh Litres per Hour. (iii) Cleaning of wall, ceiling and floor by high pressure rotary water jet with the help of German equipment which create pressure of 80-120. (iv) Removing of remaining sludge from the floor with the help of industrial vaccum cleaner. (v) Spraying of non toxic biodegraded, eco friendly, anti bacterial agent certified by a Govt approved lab to disinfect the tank from harmful pathdons. The dose utilise shall be as per OECD guide No 432. (vi) Treatment of inside tank be exposing UV radiation to kill the suspended or floating bacterial remaining in the tank.
Supply, installation, testing and commissioning in repair submersible pump set, electric driven, 415 Volt, TP, suitable for 200 mm dia bore well casing pipe complete, 5WHP, including 40 mtrs long submersible cable of size 6 Sqmm, three core and suitable starter complete all as specified and as directed.
S & F in repair 50 mm bore, galvanised iron tubing, medium grade with all fittings like sockets, elbows, bends, Tees, unions, short pieces etc. laid in trench, in any length including taking down old water tubing complete all as specified and as directed. Note: Necessary Excavation and earth work shall be measured & paid separately.
All as per item No here in before but 40mm bore pipe complete all as specified and as directed.
All as per item No 57.00 here in before but 32mm bore pipe complete all as specified and as directed.
All as per item No 57.00 here in before but 25 mm bore pipe complete all as specified and as directed.
All as per item No 57.00 here in before but 20mm bore pipe complete all as specified and as directed.
All as per item No 57.00 here in before but 15mm bore pipe complete all as specified and as directed.
S&F in repair gun metal gate/glob valve heavy duty (ISI marked) with iron wheel head screwed both ends, suitable for 15 mm bore iron pipe including testing complete all as specified & directed.
All as per item No 63.00 here in before but suitable for 20mm bore pipe complete all as specified and as directed.
All as per item No 63.00 here in before but suitable for 25mm bore pipe complete all as specified and as directed.
All as per item No 63.00 here in before but suitable for 32mm bore pipe complete all as specified and as directed.
All as per item No 63.00 here in before but suitable for 40 mm bore pipe complete all as specified and as directed.
All as per item No 63.00 here in before but suitable for 50 mm bore pipe complete all as specified and as directed.
Supply, laying & connecting in repair flat, 3 core, copper conductor PVC insulated & PVC sheathed cable 1100 Volts grade, size 10 Sqmm, laid in and including 40 mm dia PVC conduit fixed to wall/ in duct complete all as specified and as directed.
Supply, installation, testing and commissioning in repair Vertical, in line Pump, Three phase 40x40mm, RPM -3000, 2 pole, Head -240-130 Mtr, 0.75KW/15HP, 50 HZ, Capacity upto 1400 LPM, Anti -Clockwise as viewed from motor end complete all as specified and as directed. Make- CG/KSB/Kilosker or any other make mentioned in PS.
S&F in repair/replacement MCCB 630 Amp four pole, 50 KA suitable for installation inside Panel including addition alteration to existing copper /aluminium busbar system all as specified and directed by Engr-in-Charge. Make- Havells: IHLLNFC0630/ L&T/ Schinder Note:- Quoted rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 400 Amp four pole, 50 KA suitable for installation inside Panel including addition alteration to existing copper /aluminium busbar system all as specified and directed by Engr-in-Charge. Make- Havells: IHLLNFCF0400/ L&T/ Schinder Note:- Quoted rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 250 Amp four pole, 50 KA suitable for installation inside Panel including addition alteration to existing copper /aluminium busbar system all as specified and directed by Engr-in-Charge. Make- Havells: IHLLNFCF0250/ L&T/ Schinder Note:- Quoted rate include the addition/ alteration in busbar system.
S&F in Repair/ replacement MCCB 200 Amp four pole, 50 KA suitable for installation inside Panel including addition alteration to existing copper /aluminium busbar system all as specified and directed by Engr-in-Charge. Make- Havells: IHLLNFCF0200/ L&T/ Schinder Note:- Quoted rate include the addition/ alteration in busbar system.
S&F in repair/ replacement MCCB 125 Amp Four pole, 50 KA suitable for installation inside Panel including addition alteration to existing copper/ aluminium busbar system all as specified and directed by Engr-in-Charge. Make- Havells: IHLANECF0125 /L&T/Schinder Note:- Quoted rate include the addition/ alteration in busbar system.
S&F in repair/ replacement MCCB 100 Amp Four pole , 36 KA suitable for installation inside Panel including addition alteration to existing copper /aluminium busbar system all as specified and directed by Engr-in-Charge. Make- Havells:IHLANECF0100/ L&T/ Schinder Note:- Quoted rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 160Amp four pole , 27 KA suitable for installation inside Panel including addition alteration to existing copper /aluminium busbar system all as specified and directed by Engr-in-Charge Havells/ L&T/ Schinder Note:- Quoted rate include the addition/ alteration in busbar system.
M&L for taking out Fire hydrant Motor 60HP Capacity 720 rpm 3 phase 415 volt opening the motor, cutting & removing old and burnt winding wire, rewinding the motor With new super enamelled copper winding of suitable size including, bearing insulating materials, varnishing, drying, replacement of both driven end. on driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by Engr-in-Charge. Note: The quoted rates must incl. loading & unloading with to and fro transportation for workshop and vice versa.
M&L for taking out Fire hydrant jocky pump 12.5 HP Capacity 3 phase 415 volt opening the pump/ motor, cutting & removing old and burnt winding wire, rewinding the motor With new super enamelled copper winding of suitable size including, bearing insulating materials, varnishing, drying, replacement of both driven end. on driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by Engr-in-Charge. Note: The quoated rates must incl. loading & unloading with to and fro transportation for workshop and vice versa.
S&F in repairs, cast Iron butterfly valve of 50 mm bore, ISI marked, PN - 1.6 pressure grade, having Nitrile/EPDM rubber lining, SS stem, CS/SS disc. Lever operated type, with hand wheel including all jointing material i.e, nut, bolt, washer, packing material etc, duly insulated complete all as directed Make: ADVANCE/AUDCO/LEADER/CASTLE/NVR/ZOLOTO
All as per item No. 82 but bore size of 40 mm.
All as per item No. 83 but bore size of 100 mm.
Supply, fixing and connecting in repair 120W New generation energy saving and environment friendly long life LED street light made up of pressure die cast aluminium housing alloy for effective thermal management, sturdiness, excellent corrosion resistant with high power LED as lighting source and lens embedded PC/ toughened glass cover with IP66 protection and impact resistance of IK07, minimum Lumen output of fixture 13200 lumens with minimum efficacy of 110lm/W, CRI>70, THD<10%, PF>0.95, CCT- 5700K, 4KV surge protection complete all as specified and as directed.
M&L for painting on steel tubular Pole (of any height) for street light fittings including GI pipe/brackets fixed on poles, by applying two coats of synthetic enamel paint of aluminium colour including cleaning & preparing the surface properly with sand paper including making strip with yellow/black/ white colour synthetic enamel paint (road signal paint) of the required width as directed at site up to 1.5 metre height from ground level, writing numbers and letters of required size as directed at site above 1.5 metre height from ground level complete all as specified and as directed. Note: Quoted Rate shall deemed to be Inclusive of Painting numbering of Poles after Painting work.
Supply, Installation, testing and commissioning PVC, weather proof KIOSK box, size 333 x 233 x 120 mm (outside) and minimum 1.5 mm wall thickness, made out of one piece mounted SMC base and door pole mounted hinged door, comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amp including 06 Amp MCB, SP, for controlling the street light fitting including PVC sheathed copper stranded conductor cable, 1.5 Sqmm, two run, from street light fitting to KIOSK box and mild steel flat iron clamps 30x 4 mm with necessary MS nuts bolts and washers including embossing/ painting of Danger notice of size not less than 10 cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and as directed. Make- Sintex Cat part No GS JB 3020 or equivalent model of Make- FINOLEX/ UNIVERSAL Switchgear
S&F LED FLOOD Light fitting 180 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete. Make:- CG, Philips, Wipro, Havell's, halonix, Polycab
Supply and fix in repairs weather proof twin core PVC Insulated, PVC sheathed cable, 1100 V grade, copper multistrandard conductor of size 2.5 Sqmm, as in service wire conductor for looping box, O/H line to street light fittings complete including testing commission all as directed.
Comprehensive/ Routine maintenance of VRF/VRV type Acs for following size and capacity VRF/VRV. (Make: Carrier) (A) OUT DOOR UNIT 22 HP:- Air cooled VRF/VRV system - 18 Nos (I) IN DOOR UNIT CASETTE TYPE :- 1 TR - 01 No, 1.5 TR - 01 No, 2.0 TR - 25 Nos, 2.5 TR - 01 No, 3.0 TR - 01 No, 3.5 TR - 02 Nos, (ii) IN DOOR UNIT CEILING MOUNTED DUCTABLE TYPE:- 8.0 TR - 30 Nos.
Note:- (i) Four preventive Maintenance calls shall be provided during the contract period of one year. They shall be as per dates and time provided by customer during normal working hours ( Monday to Saturday between 9:00 AM to 7:00 PM) on any working day. Washing the condenser coil with water to remove the dust accumulated inside the coil. Cheking the refrigerant pipe joint with solution for any leakage in the system and ensuring that the entire piping is made fully functional. Checking & Tightening all bolts & nuts. Cheking & making fully functional all electric connections of control panel. Cheking & making fully functional all electric connections of compressor & condenser fan motors. Cheking the suction/ discharge pressure of compressor to study any abnormal running condition & rectifying the same if noticed. Checking voltage & current to study / detect any abnormal running conditions and assist in rectifying the same if noticed with in our set free unit. CARRIER, on its own, would carry out rectification steps in the equipment if needed, otherwise advice customer to take corrective action at their end. Checking voltage imbalance between phases and pointing out any problem to customer for corrections, provided any correction required in the equipment would be corrected out by CARRIER. Cheking of unloading solenoid valves and ensuring smooth functioning of the same.
(ii) The quoted rate include comprehensive maintenance, Repair and replacement including attending All major breakdown like compressor failure, replacement of electrical control panels and PCBs, Remote control etc. The quoted rate include the periodical washing of filters as per OEM recommendations. Repairing and replacement of expansion valve, safety devices and valves, replacement/ rewinding of motors and pumps, electrical contactor and relays, repair and replacement of filters etc, and other routine items such as Refrigerant gas, compressor oil and grease, Lugs, Gland, Wires and cables etc required for smooth operation of plant shall be provide by contractor at his own cost as per the manufacturer's instructions shall be deemed included in the unit rates quoted by the contractor.
(a) The cost of spares and labour for any minor or major repairs of chiller plants as and when required (as recommended by the OEM during inspection/analysis report) shall be provided by the contractor at no extra cost and rate for the same are deemed to be included in the unit rates of item as above. (b) Cost of refrigerant gas and compressor oil will be included in quoted rate. (c) The contractor is liable to maintain 21 degree centigrade temperature (plus/minus 2 degree C) and 50 % relative humidity (plus/minus 5%) in the rooms. (d) Contractor is required to enter in to "Level-3" MOU with M/S CARRIER Company. The contractor shall upload submit scanned copy of MOU with M/S CARRIER alongwith his application in Cover No 01 and also submit hard copy of MOU with his application before the last date for bid submission failing which Cover 2 shall not be opened and No claim what so ever on this account shall be entertained. The service Engineer from M/S Blue-Star (original OEM) will visit the A/C plant minimum one time in a month and will submit inspection report to the Engr-in-Charge. Necessary repair action will be taken immediately if/as required and periodical maintenance of plant will be carried out by contactor as per technical instructions OEM.
(e) In case of any minor fault in the machineries of Central AC plant due to which the plant is put off more than 12 hours the following penalties shall be recovered from the contractor:- (f) Rs. 10000/- per day will be recovered from the contractor for non rectification of defect/replacement of any unserviceable spares after 12 hours from lodging of complaint telephonically or verbally. (g) Thereafter Rs. 10000/- will be added every day till rectification of fault/ replacement of unserviceable spares as directed.
Comprehensive/ Routine maintenance of VRF/VRV type Acs for following size and capacity VRF/VRV. (Make:- Blue Star) (A) OUT DOOR UNIT 28 HP:- Air cooled VRF/VRV system - 1 No. (I) IN DOOR UNIT (HIGH WALL UNIT) :- 1.3 TR - 01 No, 2 TR - 05 No, 2.6 TR - 6 Nos.
Note:- (i) Four preventive Maintenance calls shall be provided during the contract period of one year. They shall be as per dates and time provided by customer during normal working hours ( Monday to Saturday between 9:00 AM to 7:00 PM) on any working day. Washing the condenser coil with water to remove the dust accumulated inside the coil. Cheking the refrigerant pipe joint with solution for any leakage in the system and ensuring that the entire piping is made fully functional. Checking & Tightening all bolts & nuts. Cheking & making fully functional all electric connections of control panel. Cheking & making fully functional all electric connections of compressor & condenser fan motors. Cheking the suction/ discharge pressure of compressor to study any abnormal running condition & rectifying the same if noticed. Checking voltage & current to study / detect any abnormal running conditions and assist in rectifying the same if noticed with in our set free unit. BLUE STAR, on its own, would carry out rectification steps in the equipment if needed, otherwise advice customer to take corrective action at their end. Checking voltage imbalance between phases and pointing out any problem to customer for corrections, provided any correction required in the equipment would be corrected out by BLUE STAR. Cheking of unloading solenoid valves and ensuring smooth functioning of the same.
(ii) The quoated rate include comprehensive maintenance, Repair and replacement including attending All major breakdown like compressor failure, replacement of electrical control panels and PCBs, Remote control etc. The quoated rate include the periodical washing of filters as per OEM recommendations . Repairing and replacement of expansion valve, safety devices and valves , replacement / rewinding of motors and pumps , electrical contactor and relays, repair and replacement of filters etc , and other routine items such as refrigent gas, compressor oil and grease, Lugs, Gland, Wires and cables etc required for smooth operation of plant shall be provide by contractor at his own cost as per the manufacturer's instructions shall be deemed included in the unit rates quoted by the contractor.
(a) The cost of spares and labour for any minor or major repairs of chiller plants as and when required (as recommended by the OEM during inspection/analysis report) shall be provided by the contractor at no extra cost and rate for the same are deemed to be included in the unit rates of item as above. (b) Cost of refrigerant gas and compressor oil will be included in quoted rate. (c) The contractor is liable to maintain 21 degree centigrade temperature (plus/minus 2 degree C) and 50 % relative humidity (plus/minus 5%) in the rooms. (d) Contractor is required to enter in to "Level-3" MOU with M/S Blue-Star Company. The contractor shall upload submit scanned copy of MOU with M/S Blue-Star alongwith his application in Cover No 01 and also submit hard copy of MOU with his application before the last date for bid submission failing which Cover 2 shall not be opened and No claim what so ever on this account shall be entertained. The service Engineer from M/S Blue-Star (original OEM) will visit the A/C plant minimum one time in a month and will submit inspection report to the Engineer-in-charge. Necessary repair action will be taken immediately if/as required and periodical maintenance of plant will be carried out by contactor as per technical instructions OEM.
(e) In case of any minor fault in the machineries of Central AC plant due to which the plant is put off more than 12 hours the following penalties shall be recovered from the contractor :- (f) Rs. 10000/- per day will be recovered from the contractor for non rectification of defect/replacement of any unserviceable spares after 12 hours from lodging of complaint telephonically or verbally. (g) Thereafter Rs. 10000/- will be added every day till rectification of fault/replacement of unserviceable spares as directed.
Comprehensive/ Routine maintenance of VRF/VRV type Acs for following size and capacity VRF/VRV. (Make:- DAIKIN) (A) OUT DOOR UNIT 12 HP:- Air cooled VRF/VRV system - 04 Nos (I) IN DOOR UNIT (Air Handling Unit) :- Capacity (3200 CFM - 02 No) (B) OUT DOOR UNIT 16 HP:- Air cooled VRF/VRV system - 01 Nos (I) IN DOOR UNIT (Air Handling Unit) : Capacity (4000 CFM - 01 No.)
Note:- (i) Four preventive Maintenance calls shall be provided during the contract period of one year. They shall be as per dates and time provided by customer during normal working hours ( Monday to Saturday between 9:00 AM to 7:00 PM) on any working day. Washing the condenser coil with water to remove the dust accumulated inside the coil. Cheking the refrigerant pipe joint with solution for any leakage in the system and ensuring that the entire piping is made fully functional. Checking & Tightening all bolts & nuts. Cheking & making fully functional all electric connections of control panel. Cheking & making fully functional all electric connections of compressor & condenser fan motors. Cheking the suction/ discharge pressure of compressor to study any abnormal running condition & rectifying the same if noticed. Checking voltage & current to study / detect any abnormal running conditions and assist in rectifying the same if noticed with in our set free unit. DAIKIN, on its own, would carry out rectification steps in the equipment if needed, otherwise advice customer to take corrective action at their end. Checking voltage imbalance between phases and pointing out any problem to customer for corrections, provided any correction required in the equipment would be corrected out by DAIKIN. Cheking of unloading solenoid valves and ensuring smooth functioning of the same.
(ii) The quoated rate include comprehensive maintenance, Repair and replacement including attending All major breakdown like compressor failure, replacement of electrical control panels and PCBs, Remote control etc. The quoated rate include the periodical washing of filters as per OEM recommendations . Repairing and replacement of expansion valve, safety devices and valves , replacement / rewinding of motors and pumps , electrical contactor and relays, repair and replacement of filters etc , and other routine items such as refrigent gas, compressor oil and grease, Lugs, Gland, Wires and cables etc required for smooth operation of plant shall be provide by contractor at his own cost as per the manufacturer's instructions shall be deemed included in the unit rates quoted by the contractor.
(a) The cost of spares and labour for any minor or major repairs of chiller plants as and when required (as recommended by the OEM during inspection/analysis report) shall be provided by the contractor at no extra cost and rate for the same are deemed to be included in the unit rates of item as above. (b) Cost of refrigerant gas and compressor oil will be included in quoted rate. (c) The contractor is liable to maintain 21 degree centigrade temperature (plus/minus 2 degree C) and 50 % relative humidity (plus/minus 5%) in the rooms. (d) Contractor is required to enter in to "Level-3" MOU with M/S "DAIKIN" Company. The contractor shall upload submit scanned copy of MOU with M/S "DAIKIN" along with his application in Cover No 01 and also submit hard copy of MOU with his application before the last date for bid submission failing which Cover 2 shall not be opened and No claim what so ever on this account shall be entertained. The service Engineer from M/S "DAIKIN" (original OEM) will visit the A/C plant minimum one time in a month and will submit inspection report to the Engr-in-Charge. Necessary repair action will be taken immediately if/as required and periodical maintenance of plant will be carried out by contactor as per technical instructions OEM.
(e) In case of any minor fault in the machineries of Central AC plant due to which the plant is put off more than 12 hours the following penalties shall be recovered from the contractor :- (f) Rs. 10000/- per day will be recovered from the contractor for non rectification of defect/replacement of any unserviceable spares after 12 hours from lodging of complaint telephonically or verbally. (g) Thereafter Rs. 10000/- will be added every day till rectification of fault/replacement of unserviceable spares as directed.
Comprehensive maintenance including replacement of defective/unserviceable parts/ fittings of Hot water Generators (Make: Rapid Cool)- (02 Nos) complete all specified and as directed. Contractor shall be responsible for repair and replacement of all the defective parts of complete hot water generator including pipelines and connected infrastructure and connected accessories during entire contract period. Replacements of all defective/Unserviceable parts and periodical painting, fabrication work, if any required to maintain smooth functioning of equipments, control and power wiring etc required for smooth functioning of 02 Nos equipments during entire comprehensive maintenance period shall be included in rate quoted by the contractor.
Note:- (i) Rate quoted by the contractor shall be for two Nos Hot water plants on monthly bases. (ii) Quoted rates shall be inclusive of labour element and replacement of defective/unserviceable parts/ fittings during complete comprehensive maintaince period. Old parts shall not be re-used and shall be deposited in MES store yard by the contractor. (iii) Contractor shall provide all kind of tools without any extra cost as per OEM recommendation. (iv) Tradesman shall take all preventive measures as per Code of practice of IE rules and the department shall not be responsible for ant type of untoward incident. (v) Tradesmen shall rush to spot of fault within 2 Hours of lodging complaint by the User Rep, JE in Charge or Engineer in Charge telephonically or by any other means at their own arrangement to restore the faults of equipments and to attend the complaint. If the complaint is not attended within 2 Hours, a penalty of Rs 500.00 Per complaint per Hour shall be imposed on contractor. (vi) Contractor shall provide insulation tape, cotton waste and all tools i.e hand gloves, spanner set, tool kit, tool bag etc. without any extra cost to Govt. (vii) Equipments / Machinery shall always be kept neat & clean and maintain in presentable condition. (viii) Proper Protective clothing of maintenance staff employing in breakdown duty shall be arrange by contractor without any extra cost to Govt.
Supply and fixing Rigid PVC piping 32 mm dia complete with fittings, supports and duly covered with 9 mm thick closed cell nitril rubber insulation complete all as specified and directed. Note: Providing and fixing in position the following size of PVC (UPVC quality) pipes, cut in required lengths and joined with PVC cement and also providing and fixing in position the necessary "U" trap elbows, tees, and reducer and all types of fittings. Cost to include all necessary as required. Necessary Wall cutting and making the wall good and its cost should be included. The pipe to be insulated by 9mm thick nitrile rubber thermal insulation of class 0 category.
M&L for control wiring with 2 core X 0.75 sqmm ,(Sheilded wire) from outdoor to indoor unit with all necessary accessories to make it functional as per OEM Recommendation Make : Finloex/Havells/Polycab
Supply, installation, testing and balancing of supply air Diffuser with volume control dampers powder coated extruded aluminium construction complete all as specified and directed.
Supply, installation, testing and balancing of Return air Diffuser without volume control dampers powder coated extruded aluminium construction complete all as specified and directed.
Supply and fixing of fire proof double layered canvas cloth connection for ductable outlet including inspection opening complete with flanges made out of 22 GSS sheet on both side for connection to Ductable and GSS Duct with nuts, bolts complete all as specified and directed.
Supply charging of refrigerant Gas
Vishal Traders
RUCHIKA ENGG.WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .