Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.9 LAccepted-AOC 2ND FLOOR SC ROAD SANTA PLAZA TEZPUR DISTT SONITPUR ASSAM PIN 784001 | SONITPUR | ASSAM | 784001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹79.5 L+₹10.6 L (15.4%)Rejected-Finance HARIGAON PO NIKAMUL SATRA DIST SONITPUR ASSAM PIN 784001 | SONITPUR | ASSAM | 784001 | L2 | Rejected-Finance HIGH BID VALUE |
Tender Value
₹74.5 L
EMD Value
₹1.4 L
Closing Date
5 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL GANESH ZAPE
HQ CWE TENGA PIN 900194 C/O 99 APO
REPAIR/MAINT OF AIRFIELD/HANGER ETC AT ARMY AVN UNITS UNDER GE MISSAMARI.
2021_MES_498455_2
8279/E8
Open Tender
Civil Works
Item Rate
180 days
MISSAMARI
C a(i)
8 documents required · 8 mandatory
₹1,000
GE MISSAMARI
₹1.4 L
Yes
25 Mar 2022
12 Feb 2022
12 Mar 2022
12 Feb 2022
5 Mar 2022
19 Feb 2022
60 days
Amount
Demolition of cement concrete in ground floor and paving not exc 15 cm thickness (below or above ground level), complete all as specified and directed.
M&L for 75mm thick Cement Concrete, type B-2, 1:2:4 (40mm graded aggregate) as in Plinth Protection/Hardstanding/path etc, finishing Concrete surfaces even and smooth with out using extra cement complete all as specified and as directed.
M&L for 100mm thick cement concrete,type B-2, 1:2:4 (40mm graded aggregate) as in Hardstanding/path finishing concrete surfaces even and smooth with out using extra cement, complete all as specified and directed.
Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), removing from the Sites and rubbish off the Premises, complete all as specified and as directed.
M&L for Non-Skid Coloured Ceramic Tiles 7mm to 8mm thick (Square /Rectangular), area of each Tile exc. 0.11 Sqm but not exc. 0.18 Sqm in Floors, etc. set and jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Tiles, including screed bed or bedding layer of 15 mm thick in CM (1:6) complete all as specified and directed.
M&L for Non-Skid Coloured Ceramic Tiles 7mm to 8mm thick (Square /Rectangular), area of each Tile exc. 0.18 Sqm but not exc. 0.38 Sqm in Floors, etc. set and jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Tiles, including screed bed or bedding layer 15 mm thick in CM (1:6) complete all as specified and directed.
M&L for glazed ceramic coloured tiles (350x250x7mm) /(350x450x7mm) thick in vertical surfaces including 10 mm thick rendering in CM 1:4 and set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles complete all as specified and directed.
S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Corrugated Steel Sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified, complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, Pre-painted Galvalume aluminium and fibre glass sheeting of any gauge and thickness or similar Roof Coverings and wall etc, complete all as specified and as directed.
S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Plain Steel Sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed.
S&F Plain, galvanised, mild steel sheeting of 0.80mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, complete all as specified and directed.
M&L for 2 mm thick Fibre glass reinforced translucent corrugated polycarbonate sheeting fixed with coach screw and washer in roof including taking down old, complete all as specified and as directed
Dismantling wrought iron or mild steel work of any description, not otherwise provided for structural steel work including doors, gates, etc., complete all as specified and as directed.
M&L for M.S work in angle iron/flats/Pipes/plates in posts, rafters, purlins, wind tie, etc connected to common rafters of any size confirming to Fe 410-W(grade-E-250) quality A including necessary drilling holes, cutting tops to shape welding etc and fixed with nuts & bolts etc complete all as specifed and directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for welding in repairs exc 2.5 but not exc 5cm in length of metal exc 6mm and n.exc 9mm thick complete all as spd and directed
M&L for prepration of new steel surfaces and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and directed.
S&F Sandwich PUF corrugated/ plain Panels of 50mm overall thickness having PPGI sheeting of not less than 0.5mm fixed with self tapping screws on roofs/cladding for a height up to 15.00 mtrs including taking down existing panels of any description complete all as specified and directed.
Dismantling of wall & ceiling boards of any description/thickness fixed with nails/screws in any position complete all as specified & directed.
S&F GI frame with powder coated work for seamless ceiling compresing premeter channel 0.55 mm thick with two unequal flange of 20 and 30 mm and web of 27 mm fixed to surroundings walls with GI wire 4.0mm dia complete with suspenders complete all as specified and directed.
S&F 4mm thick designer Non asbestos fibre cement building boards prepainted fixed to GI snap grid in ceiling flat complete all as specified and directed.
Taking down unserviceable aluminium doors, window ventilator shutters and partition etc of any description, complete all as specified and directed.
S&F aluminium door shutters,with frame of aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws, double action floor door spring hydraulically regulated including 5.5mm thick plain/tinted glass etc. complete all as specified and directed.
S&F aluminium window and ventilator shutter, sliding/fixed/side hung type with or without sash bars includind necessary joining cleats,glazing clips, rubber packing ,anodised aluminium snap beading,screws, 5.5mm thick plain/tinted glass, 0.36mm stainless steel wire mesh of 1.4mm avg apreture etc.complete all as specified and directed.
M&L Pre-cast Reinforced Cement Concrete 1:2:4 (20mm graded aggregate) in Cover Slab of Manholes, Septic Tanks, etc., set in Cement Mortar 1:4 including necessary forms, moulds, etc., complete all as specified and directed.
M&L for TMT Bars 10mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for Columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and as directed.
S&F nylon HDPE bird proofing/anti bird net of 2cm pitch as per the sample available at site and as directed by Engr-in-Charge. The work shall be executed at height upto and including 15.00 mtrs. Rates quoted by the contractor shall deemed to inclusive of necessary scaffolding and all other fittings and finding materials as required for fixing of the net completed all as directed.
M&L for 2.50 mm thick thermo plastic retro reflective painting white/Golden/Yellow colour using hot thermoplastic material by automatic applicator machine filled with glass beads dispensers tank complete all as specified and directed.
M&L for applying one coat for painting lines/dash line/arrow lines on Roads, Pavements of the like exc. 10 Cm wide with Road Marking Paint white and yellow in colour including preparing old treated surfaces complete all as specified and as directed.
M&L for preparation of old painted surfaces of wall and 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) and as directed with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
M&L for preparation of old painted CGI/PGI steel roof sheets, over 10cm in with or girth and applying one coat of synthetic enamel roof paint complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old decorated plastered wall surface applying One coat of oil bound distemper on wall all as specified and directed.
Taking down cement or cement lime plaster of any description incl dado/skirting of any description on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15 mm thick plaster in CM 1:6 on stone masonry surfaces (internal) to be finished fair & even complete all as specified and as directed.
M&L for rendering 15 mm thick plaster in CM 1:4 on stone masonry surfaces (external) to be finished fair & even complete all as specified and as directed.
Repairs to Aluminium door exc 1.50 sqm but n exc 5.00 sqm by necessary joining cleat/glazing clips/rubber neoprene/ packing handles 2 Nos in each door/hinges/anodised aluminium snap beading screw etc and refix in same opeing after compete repair except glass complete all as specified.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top incl taking down existing treatment:- (i) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying as in roof Slab including preparation of surface to receive screed bed. (ii) Applying one coat of cold bituminous primer in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces. (iii) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction and sealing the joints with application of cold bitumen. (iv) Applying Two coat of aluminum paint over the APP membrance .
Taking out Runway light carefully from CI Transformer housing boxes by unscrewing nuts bolts and detaching isolating transformer and electrical connection repairing the same by opening Cover, re-wir-ing the Light Fitting with 2.5 Sqmm Copper Conductor Cable, multi-stranded, replacing unserviceable Parts as required/ordered, re-fix ing Light Fitting in Original Position after repaired and connecting up, complete all as specified and as directed. NOTE:– (a) Spare Parts such as Lamp, Holder, Isolating transformer, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE.
Taking out unsv/burnt UG Control Cable/ Runway lighting cable any cross sectional area and connection of any description of any description laying in trenches all as specified and directed.
Taking out ATC Beacon from ATC Tower for repair and replacement of unsv component repair/rewinding of Synchronous motor and electrical connection repairing the same by opening Cover, re-wir-ing the Light Fitting with 2.5 Sqmm Copper Conductor Cable, multi-stranded, replacing unserviceable Parts as required/ordered, re-fix ing Beacon in Original Position after repaired and connecting up, complete all as specified and as directed. NOTE:– (a) Spare Parts such as Lamp, Holder, Control cable, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE.
Segregation all parts of single phase 240 volts Synchronous Motor of any type, make and capacity obtained from item no 3 above, cutting & removing existing burnt/short circuited winding wire complete, cleaning of core grooves and surfaces, rewinding the motor with superior quality enamelled copper winding wire of as original gauge, numbers of turns and coils including insulating material such as sleeves, cotton/PVC tape varnishing etc, reassembling the motor complete all as specified and directed by Engr-In-Charge.
Repair of unsv Constant current regulator panel at ATC CCR room by carefully opening of panel and removing unsv component and repair of unserviceable remote control desk ,including replacement of unserviceable IC,IGBT , Chip , IC Card,15 KW Transformer with panel control wiring complete all as specified and directed by Engr-in- charge. NOTE:– (a) Spare Parts such as IC,Chip , PCB electronic Card etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE.
Supply only in replacement of unsv IGBT as per sample for Constant current regulator complete all as specified and directed.
Supply only in replacement of unsv chip as per sample for Constant current regulator complete all as specified and directed.
Supply only in replacement of unsv PCB Electronic card as per sample for Constant current regulator complete all as specified and directed.
Supply only in replacement of unsv 15 KW output current transformer as per sample complete all as specified and directed.
Supply & laying LT UG XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured Electric Power Cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, cross-sectional area 16 Sqmm 4 Core, laid in trenches/surface of Wall/in GI Pipe along with Pole for connection to OH Lines including Brass Cable Glands Mild Steel Flat Iron Clamps, etc. and Testing, complete all as specified and as directed. NOTE : Earthwork, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
Supply,installation,testing and replacement of bidirectional approach light suitable for 200W,6.6 Amp AC constant current series system with bi pin halogen Lamp complete with all accessories such as base plate ,breakable coupling,mounting assembly ,gasket, Lamp Holder,Lenses,bi pin,Secondary lead of adequate length etc confirming to ICAO Annex 14 complete bidirectional type with following fitments all as specified and as directed by Engr-in-Charge. Make:-AMA/THORN (i) Clear /Clear
(ii) 180 degree clear /yellow Make:-AMA/THORN
(iii) 180 degree Green /Red Make:-AMA/THORN
(iv) 180 degree Amber/yellow Make:-AMA/THORN
S&F Omni directional taxi way edge light suitable for use with 45 W 6.6 A AC constant current series system complete with accessories such as base plate breakable coupling mounting assembly gasket lamp holder lenses bi pin secondary lead of adequate length confirming to ICAO Annex 14 complete all as specified and directed by Engr in charge
Supply and replacement of Halogen lamp bipin holder 200W ,6.6 Amp for taxiway / Runway light fittings.Make:-Thorn/AMA/Osram
Supply and replacement of Halogen lamp bipin holder 45W ,6.6 Amp for taxiway / Runway light fittings.Make:-Thorn/AMA/Osram
Supply and replacement of 180 deg Colour filters for runway lighting Red/Green/Yellow/Clear AMA for taxiway / Runway light fittings.Make:-Thorn/AMA
Supply and replacement of Clear spreader lens for APN approach light
Supply and replacement of Green spreader lens for APN threshold light.
Supply and replacement of Red spreader lens for APN end light
Supply and replacement of Base plate with gasket and bolts for taxiway / Runway light fittings.Make:-Thorn/AMA
Supply and replacement of 360 deg outer clear lens for AVN Runway light fittimg.
Supply and replacement of AMA connector kits for 6 sqmm copper conductor cable,5 KV Grade
Supply and replacement of Breakable coupling for R/W/Taxi fittings
Supply installation testing in replacement of isolating transformer 5KV, 50 H Series type encapsulated in polyster resin for all moulded with neoprene rubber as specified and suitable for Air field lighting System conforming to FAA/ICAO and IS 12290 1987 of capacity 200W ,6.6Amp,for runway lighting complete all as specified and directed by engr-in -charge. (Note:-Excavation,Sand cushioning,protective ,covering and refilling the trenches etc shall be measured and paid Separately) Make:AMA/Thorn.
Supply installation testing in replacement of isolating transformer 5KV, 50 H Series type encapsulated in polyster resin for all moulded with neoprene rubber as specified and suitable for Air field lighting System conforming to FAA/ICAO and IS 12290 1987 of capacity 45W ,6.6Amp,for runway lighting complete all as specified and directed.Make:AMA/Thorn.
Supply ,laying ,jointing , testing and commisioning 6 Sqmm Airfield lighting cable single core 5KV Grade stranded copper conductor PVC insulated PVC sheathed unshielded antitermite and anti rodent treated unarmoured cable generally conforming to IS 1554 part I as amended upto date as specified in particular specification and all as required
Supply and replacement of cast iron transformer housing boxes water tight cylindrical metal container of size 330 mm dia and 450 mm high all round cast iron moulding except top which will be 15 mm thick having two earth bolts nuts and washers 10 mm dia and one hole with GI nut to suit entry of 50 mm dia pipe .Opening on top with a cover plate to be fixed with 6 volts neoprene rubber gasket etc ,including painting with one coat of synthetic paint as required including cement concrete/foundation PCC 1:2:4 using 20 mm graded crushed stone aggregate thickness of concrete 150mm in all the sides and 100 mm in bottom including dressing of earth soil and finishing with 12mm thick cement plaster 1:3 on exposed surface incl necessary excavation and earth work in any type of soil all as directed.
M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh refilling with vegetable soil without bolders and stones, gravels and aggregate etc,and CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion. NOTES : The unit rate includes for protection pipe and GI strip dia from top of earth plate up to 5.00 meter above ground level.
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified.
Removing excavated material not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above starting point complete all as specified.
M&L sand cushioning in trenches for cable protection with coarse sand laid dry in trenches with uniform thickness including consolidation complete all as directed.
M&L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable all as directed.
S&F GI Tubing light grade of size 50mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc all as specified and directed.
S&F GI Tubing light grade of size 80mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc all as specified and directed.
Repair and Maintenance of 'H' & 'T' indicator lamps including replacement of control wiring , painting of H/T indicator with existing yellow paint complete all as specified and all as directed. NOTE:– (a) Spare Parts such as Lamp, Holder, Control cable, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE.
Supply and fixing of Lamp of Higher suitable intensity as per aviation standard and as per sample obtained from item No. 76 here in before suitable for H/T indicator complete all as specified and directed.Make:Osram or equivalent reputed Make.
Supply and fixing of Lamp holder as per sample obtained from item No. 76 here in before suitable for H/T indicator complete all as specified and directed.
Supply of Beacon halogen 500W light as per sample obtained from item No.41 here in before suitable for ATC Beacon complete all as specified and directed.Make:Osram or equivalent reputed Make.
Servicing/Overhauling of 3 Phase, 3HP capacity Induction Motor alongwith movable housing with following others repairs :- (a) Taking out Motor and movable housing from its Position and disconnecting all Cable Connections. (b) Dismantaling of induction Motor complete Part by Part carefully, testing all Coils, degreasing bearing and display all the Parts without damaging any portion for inspection of Engineer-in-Charge to ascertain the Serviceability of existing Parts. (c) Heating & Varnishing to Stator with super quality varnish and dried out properely with external heat as ordered and as directed. (d) Reassembeling the Motor complete with all existing Serviceable Parts obtained against Item 1(b), greasing the Bearing with bearing grease and new Parts as ordered by Engineer-in-Charge (New Parts shall be measured and paid separately under relevant Item here-in after) (e) Reinstall the Motor at its existing Position, connecting all Cable connections and testing on completion complete all as specified and as directed. NOTE: i) Any unforeseen Minor Repairs and Minor Parts which are required to complete the repair work for smooth functioning of Motor are deemed to be included with the Unit Rate and labour element involved in replacement is included in unit rate quoated against this Item. (ii) Transportation of motor parts for machining, rewinding from work site to lathe shop (Work shop) are deemed to be included with the Unit Rate. (iii) Rewinding of Motor, any machine work where involved shall be measured and paid separetely against relevant Item of this Schedule.
Rewinding burnt coils of Induction Motor of any make and type of capacity, 3Phase, 3HP, 415Volts with super enamelled copper winding wire as per existing size and guage to achieve the required /specified RPM including taking out old unserviceable winding, cleaning/ repairing damaged slots, complete all as specified and as directed.
S & F 3 phase ,32A/415 V plastic handle Reverse Forward Switch for 3 HP induction motor complete all as specified and directed. Make:- Fybross/WACO/CROMPTON or equivalent in reputed make.
S & F 3 phase,DOL Reversing Starters,complete with combination of 2 AC Electro Mechanical Contactor,with protection relay, Overload protection, Phase Loss, Phase Unbalance ,Suitable for 3 HP induction motor complete all as specified and directed.Make- Concord Electricals/WACO/HAVELLS
Greasing and overhauling of Hanger door guiding rail wheel , incl replacement of unsv shaft bearings , replacement of unsv GI wire rope, replacement of broken shaft of door mechanism for smooth movement of the hanger door leaves complete all as specified and directed by Engr-in- Charge . NOTE:– (a) Spare Parts such as Bearing, Wheel shaft, Wheel etc. wherever required to be included in the QUOTED UNIT RATE. (b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE.
S & F 'V"/ Metal Chain belt drive for Transfer of power to hanger gate lower wheel, complete all as specified and as directed.
S & F MCCB 4 Pole 250 Amps, thermal magnetic type DN2-250D with breaking capacity 36 KA with thermal magnetic release at 415 volts, including spreader terminal, make: L&T Cat part No. CM92109OOP1OG and equivalent in Legrand/ Indo Asian complete all as specified.
Supply & laying LT UG XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured Electric Power Cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, cross-sectional area 120 Sqmm 3.5 Core, laid in trenches/surface of Wall/in GI Pipe along with Pole for connec-tion to OH Lines including Brass Cable Glands Mild Steel Flat Iron Clamps, etc. and Testing, complete all as specified and as directed.Make - Polycab/ KEI/Havells NOTE : Earthwork, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
Taking down existing unserviceable Highbay light /Flood Light of any description/type/ size ,carefully from hanger Ceiling height of 18 mtr, batten/conduit including removal of batten/ conduit/ gutties/ wooden boards complete all as specified and directed by Engr-in-charge.
Taking down the existing unserviceable main switch/ cut out/ DBs/ MCCB of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
M&L for Submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheated (FRLSH) multistranded 1100 volts grade with copper conductor drawn through and including non-metalic Rigid PVC Conduit ISI marked and its accessories including one run of single core 4.0 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor for Highway / Flood Lights etc complete all as specified and directed.
M&L for Submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheated (FRLSH) multistranded 1100 volts grade with copper conductor drawn through and including non-metalic Rigid PVC Conduit ISI marked and its accessories including one run of single core 6.0 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor complete all as specified and directed.
M&L for Submain wiring with 4 runs of single core 10 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC concealled conduit ISI marked and its accessories including single run of single core 10 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor complete all as specified and directed.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 Flood light fitting luminaire, with system efficiency ≥110 lumen/W,AC120-300 V with high power LEDs as light source and Secondary lenses 10KV SPD included with high efficiciency electronic driver of capacity 120 watts, with pre wired and necessary mounting arrangement and provision of 4.00 sq mm three core flexable copper conductor cable multi stranded ,connected to existing points in Hanger beam angle of any description complete all as directed by Engineer- in-charge.Make: Make:Crompton, Cat No LFLN-120-CDL/60-M, Model- PLUTO NEO, Make-Crompton or eqv in Havells/Surya/Philips
S & F Energy saving new generation environmental friendly long life with high luminious efficacy upto ≥ 150 LPW versatile presure die cast aluminium IP 66 protected Highbay light fitting luminaire with descrete high lumen LEDs as light source and electronic driver of capacity 150 watts with pre wired and necessary mounting arrangement and provision of 4.00 sq mm three core flexable copper conductor cable multi stranded ,connected to existing points in Hanger beam angle of any description complete all as directed by Engineer- in-charge.Cat No CIP-320-150-57-60D-HL4-GL-NSR, Model- SURROUND HYPERION, Make- CROMPTON or eqv in Havells/SURYA
S&F LEDs aviation light energy saving new generation environmental friendly long life versatile presure die cast aluminium housing with polycarbonate enclosure with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 and for fixing taking GI pipe pipe medium grade 40 mm dia 1.5 mtr long, complete all as specified and as directed. (Make :- BAJAJ, Cat Part No-110731 or equivalent in Havells/Phillips/Crompton).
S&F 63 A ,5 Pin (3 P+N+E) Metal Plug & Socket Enclosure for Three Phase connection all as specified and directed. Model:- DBMPS463SD, Make :-L&T or equivalent in Schinider and Legrand.
S&F MCB TPN 415 volts suitable for fixing in MCB VTPN of capacity 63 amps complete all as specified and directed.Model:-BB40630D Make :-L&T or equivalent in Schinider and Legrand/Indo Asian
Supply and fixing for single pole and neutral enclosure with a two pin and earth plug and socket complete with on one single pole MCB 20 Amp, 240 volts.
S&F MCB SPN 230 volts suitable for fixing on MCB DB of capacity 32 TO 40Amps complete all as specified.Make:L&T /Legrand/Indo Asian
S&F MCB SP 6 to 30 Amps 240 volts for fixing on MCB DB's complete all as specified.Make:L&T /Legrand/Indo Asian
S&F MCCB 4 Pole 200 Amps, thermal magnetic type DN2-250D with breaking capacity 36 KA with thermal magnetic release at 415 volts,including spreader terminal complete all as specified and directed. make: L&T Cat part No. CM92109OON1OG and equivalent in legrand and Indo Asian
S&F sheet metal enclosure MCB VTPN 12 way Double door Ready to use DBs - Provided with insulated vertical phase bus-bars |neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification labels With provision for 4 Pole MCCB 200 A as incomer and SP/SPN MCBs as outgoing complete all as specified and directed.Model:- DBVTM012DD, Make L&T and equivalent in legrand and Indo Asian.
M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised Iron strip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised steel and GI Protection pipe light grade 40 mm dia bore for watering funnel with wire mesh refilling with vegetable soil without bolders and stones, gravels and aggregate etc,and CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion. NOTES : The unit rate includes for protection pipe and GI strip dia from top of earth plate up to 5.00 meter above ground level.
Markson
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .