| 1 | L1₹36.4 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹37.8 L+₹84,415.30 (2.28%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹40.2 L+₹3.2 L (8.75%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹40.2 L+₹3.3 L (8.80%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹40.3 L+₹3.3 L (8.87%)Rejected-Finance RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L5 | Rejected-Finance BEING NOT LOWEST |
| Sl No | Description | Qty | Unit | Kunal Construction Co. L4 | HANUMAN BUILDERS L5 | M/s M M BAHL L9 | SABHARWAL CONSTRUCTION CO. L2 | M/S Davinder Kumar L3 | M/S CHANDER MUNI L7 | BRK ASSOCIATES L8 | UNIQUE BUILDERS L1 | PG CONSTRUCTION AND COMPANY L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as spd & directed. | 340 | Sqm | 10 ₹3,400 | 35 ₹11,900 | 6 ₹2,040 | 15 ₹5,100 | 20 ₹6,800 | 10 ₹3,400 | 15 ₹5,100 | 5 ₹1,700 Lowest | 5 ₹1,700 Lowest |
| 2.00 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, incl wooden / metal fillets & grid, complete all as spd & directed. | 200 | Sqm | 5 ₹1,000 | 20 ₹4,000 | 12 ₹2,400 | 15 ₹3,000 | 10 ₹2,000 | 10 ₹2,000 | 15 ₹3,000 | 5 ₹1,000 | 3 ₹600 Lowest |
| 3.00 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as spd & directed. | 5 | Cum | 200 ₹1,000 | 150 ₹750 | 180 ₹900 | 200 ₹1,000 | 150 ₹750 | 50 ₹250 Lowest | 255 ₹1,275 | 50 ₹250 Lowest | 99 ₹495 |
| 4.00 | Demolition of cement concrete (unreinforced) n. exc. 15cm thickness (below or above ground level) complete all as spd & directed. | 5.25 | Cum | 200 ₹1,050 | 150 ₹787.5 | 220 ₹1,155 | 200 ₹1,050 | 150 ₹787.5 | 50 ₹262.5 Lowest | 250 ₹1,312.5 | 50 ₹262.5 Lowest | 105 ₹551.25 |
| 5.00 | Dismantling floor tiles stone, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as spd & directed. | 300 | Sqm | 10 ₹3,000 | 30 ₹9,000 | 5 ₹1,500 Lowest | 11 ₹3,300 | 15 ₹4,500 | 5 ₹1,500 Lowest | 12 ₹3,600 | 5 ₹1,500 Lowest | 7 ₹2,100 |
| 6.00 | Taking down cement or cement lime plaster, any description, on brick or stone walls incl racking out joints, hacking for key, scrubbing down with water, etc. complete all as spd & directed. | 50 | Sqm | 60 ₹3,000 | 10 ₹500 | 22 ₹1,100 | 11 ₹550 | 13 ₹650 | 10 ₹500 | 11 ₹550 | 5 ₹250 Lowest | 5 ₹250 Lowest |
| 7.00 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sq. m but n exc 4 sq. m each complete all as spd & directed. | 3 | Each | 50 ₹150 | 220 ₹660 | 99 ₹297 | 90 ₹270 | 200 ₹600 | 10 ₹30 Lowest | 100 ₹300 | 50 ₹150 | 98 ₹294 |
| 8.00 | All as per item No. 7 above but n. exc 1.5 sq. m each. | 7 | Each | 50 ₹350 | 180 ₹1,260 | 99 ₹693 | 90 ₹630 | 150 ₹1,050 | 10 ₹70 Lowest | 120 ₹840 | 50 ₹350 | 100 ₹700 |
| 9.00 | S&F pre-painted galvalume aluminium zinc coated (150GSM) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering, ridge, fixed with self tapping screws complete all as spd & directed. | 320 | Sqm | 700 ₹2,24,000 | 680 ₹2,17,600 | 600 ₹1,92,000 | 655 ₹2,09,600 | 670 ₹2,14,400 | 725 ₹2,32,000 | 685 ₹2,19,200 | 565 ₹1,80,800 Lowest | 691 ₹2,21,120 |
| 10.00 | S&F Pre-painted galvalume aluminium zinc coated (150GSM) GI based machine moulded profile ridge/corrugated steel sheet ridge 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering, fixed with self tapping screws complete all as spd and directed. | 20 | Sqm | 700 ₹14,000 | 800 ₹16,000 | 700 ₹14,000 | 700 ₹14,000 | 700 ₹14,000 | 725 ₹14,500 | 685 ₹13,700 | 565 ₹11,300 Lowest | 700 ₹14,000 |
Tender Value
₹48.9 L
EMD Value
₹97,740
Closing Date
15 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Delhi Cantt-10.
GE (West) Delhi Cantt-10
Spl Repair to Bldg No T-194 at 262 Transit Camp and Provn of certain sanctioned Revenue and Minor works in the area of AGE B/R-1 and AGE E/M under GE (West) Delhi Cantt-10
2025_MES_746249_1
GE/DW/TOKEN/115 OF 25-26
Open Tender
Civil Works
Item Rate
180 days
delhi
Class D Category a(i)
9 documents required · 9 mandatory
₹500
GE (West) Delhi Cantt
₹97,740
Yes
21 Feb 2026
26 Dec 2025
17 Jan 2026
26 Dec 2025
15 Jan 2026
9 Jan 2026
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as spd & directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, incl wooden / metal fillets & grid, complete all as spd & directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as spd & directed.
Demolition of cement concrete (unreinforced) n. exc. 15cm thickness (below or above ground level) complete all as spd & directed.
Dismantling floor tiles stone, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as spd & directed.
Taking down cement or cement lime plaster, any description, on brick or stone walls incl racking out joints, hacking for key, scrubbing down with water, etc. complete all as spd & directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sq. m but n exc 4 sq. m each complete all as spd & directed.
All as per item No. 7 above but n. exc 1.5 sq. m each.
S&F pre-painted galvalume aluminium zinc coated (150GSM) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering, ridge, fixed with self tapping screws complete all as spd & directed.
S&F Pre-painted galvalume aluminium zinc coated (150GSM) GI based machine moulded profile ridge/corrugated steel sheet ridge 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering, fixed with self tapping screws complete all as spd and directed.
S&F false ceiling with powder coated GI grid of size 600x600 mm using main Tee of size 24x28x0.40mm prepunched to accept cross tee of size 24x28x0.40mm and wall angles of size 25x25x0.40mm fixed with wall around of size with and including 4mm thick fiber cement board white colour designer tiles as approved by GE of size 595x595 mm placed in the grid and held in position duly suspended by 4mm dia GI wire hanger from the roof with holding down clips, butter fly clips and necessary provision for light fixture etc complete as per manufacturers instructions complete all as spd & directed.
M&L for brick work with sub class 'B' old size bricks in CM 1:6, straight or curved on plan exc 6 m mean radius complete all as spd & directed.
M & L for brick work with sub class ‘B’ old size bricks, straight or curved on plan and any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
M & L for providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates in roof parapet coping, roof kerb or mud slops and the like including weathering, slightly rounded or chamfered angles and throating as directed) complete including necessary form work complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-2 (40mm graded aggregate) for plinth protection over rammed earth finished even & fair complete all as spd and directed.
M&L for 25mm thick PCC 1:2:4 type B0 using 12.50mm graded stone aggregate as in levelling couse of sub base all as specified and directed.
M&L for 15mm thick screed bedding layer in CM 1:6 for laying floor finishes complete all as spd and directed.
M&L for 10mm thick double charged glazed Virified tiles (square/ rectangular) polished, light shade, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for 10mm thick rendering on wall in CM 1:4 as backing coat of skirting all as specified and directed
M&L for Glazed ceramic coloured tiles in vertical surface 300x450x7 thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed.
M&L for rendering 12-15mm thick ready mixed plaster on any type brick work or concrete surfaces complete all as spd & directed.
M&L for rendering 15mm thick cement plaster in CM 1:6 on brick work or concrete surfaces other than fair face finished even and fair complete all as spd & directed.
M & L for machine cut kota stone slab flooring 20-25mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for providing 1mm thick wall care putty on wall surface complete all as specified and directed.
M&L for Priming plastered and other surfaces with alkali resistant priming paint complete all as specified and directed.
M&L for preparing surface of wall and applying two coat of oil bound distemper all as specified and directed.
Preparing surface by complete removal of existing treatment of wall any layer incl brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots all as specified and directed
S & F in repairs for sink with draining board made out of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm complete all as specified and directed.
S & F in repair for 15 mm bore brass CP sink mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F Factory made 35mm thick second class hard wood plain framed panelled door shutters (Minimum two panels) with lock rail and panels of 9mm thick BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces. The sizes of rail and stiles as per IS:1003 ( Part I), kiln seasoned and chemically pressure treated and fixed in position complete all as spd & directed .
S&F factory made 35mm thick 2nd class hard wood glazed / gauged shutters, open, rebated prepared to receive glass , guage etc W/O sash bars for doors as specified in SSR Part I complete all as spd & directed .
S&F mild steel butt hinges 100mm size complete all as spd & directed.
S&F aluminum anodized barrel tower bolts of extruded section of size 150 mm complete all as spd & directed.
S&F aluminium handles cast type anodised of size 150 mm complete all as spd & directed.
S&F aluminium alloy, anodised, sliding door bolt (length of bolt 300 mm) with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as spd & directed.
M&L for preparting new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as spd & directed .
M&L for powder coated (50micron) Anodised aluminium frame for doors, windows, ventilators, grill, partitions, sliding tracks, aluminium section for shutters suitable for two/three track window and aluminium section sliding members min weight section 0.50kg/RM incl all necessary fittings and fixtures, jointing cleats, rubber packing, silicon packing etc complete all as specified and directed.
S&F powder coated (50 micron) aluminium window and ventilator shutters, side hung type with/ without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21, 100mm long (2 Nos) suitable handle (1 No) complete all as specified and directed.
S&F Anodised aluminium powder coated door shutters,aluminium section weighing 0.55 kg/ m including necessary joining cleats,glazing clips, ruber neoprene packing, aluminium handles 2 Nos 150mm long in each shutter, hinges 03 Nos 100mm long in each shutter, Tower bolt 02 Nos 150mm long in each shutter, anodised aluminum snap beading screws etc. complete all as specified Note:-(Glass for doors and windows under this item shall be measured and paid seperately under respective item).
M&L for stainless steel wire cloth 0.36 mm nominal dia of wire and average width of apperture 1.40 mm fixed to door / window (steel/wooden) complete all as specified & directed.
S&F for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors/door frames; ladders; framed balusters; walk ways; railings; framework of water tanks stageing and similar work conforming to Fe.290.Gde-E-165 complete all as spd and directed.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of syntethic enamel paint over one coat of red oxide Zink chrome complete all as spd & directed.
Dismantling framed timber scantlings any size in section, in any position (as in purlins etc) complete all as spd & directed.
M&L for Steel work in tubular trusses, purline, rafter etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S-1161-1979 grade st 240 complete all as specified and directed.
Dismantling Water tanks exc 500 but not exceeding 1000 Ltr capacity and removing to store complete all as specified and directed.
M&L for 1000Ltr capacity Rotational moulded polyethylene water storage tanks tripple layers white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified including all necessary tank connection and cover,reducer, 25mm bore ball valve high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 25mm-455gms) complete all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified & directed.
S&F 100mm bore cast iron soil waste and vent pipe (Cast type) in any length with or without ears with cement joints fixed to walls or laid in floor etc complete all as specified and as directed.
M&L cast iron floor trap 100mm outlet diameter with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as spd & directed.
S&F for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms, uinal Partition and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and 15 mm screed bed in CM 1:4 complete all as specified and as directed.
S&F in repair flexible PVC waste pipe with coupler complete 900mm length complete all as specified and directed.
S&F in repair vitreous chinaware wash hand basin (WHB), white, size 580x450mm complete including provision of pair of mild steel angle iron brackets of suitable size duly painted, 32 mm dia chromium plated waste coupling, PVC waste pipe and cutting for pinning in ends of brackets in wall etc including PVC connection pipe 15mm size 600mm long with PTMT nuts complete all as spd & directed by Engr-in-Charge.
S & F in repairs for 15 mm bore brass centre hole CP wash hand basin mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified.
S&F in repair 15mm dia chromium plated fancy type Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
S&F in repair 15mm bore dia pipe angle/stop valve chromium plated fancy type,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed with long shank and cup (concealed type) complete all as specified.
Taking up or down 15mm dia steel tubing and connection incl cleaning or removal from the site of work complete all as spd and directed by Engr-in-Charge.
All as per item No. 57 above but 20mm dia.
M&L 20mm CPVC pipes SDR 11 with all plain CPVC SDR 11fittings and fixed complete to walls, ceiling or laid in floor including taking up or down old steel tubing and connections all as spd and directed.
M&L 25mm CPVC pipes SDR 11 with all plain CPVC SDR 11fittings and fixed complete to walls, ceiling or laid in floor including taking up or down old steel tubing and connections all as spd and directed.
S&F in repair chromium plated stainless steel curtain rod 25mm bore fixed with fixing brackets, stops, rollers etc complete all as specified and directed.
S&F for drapery rod's side bulb stainless steel chromium plated suitable for 25mm bore curtain rod complete all as specified and directed.
S&F in repair coated MS drapery rod's brackets as required complete all as specified and directed complete all as specified and directed.
Material & Labour for applying and finishing walls surface with two or more coats of Acrylic Smooth exterior paint of required shade over and including priming coat of exterior primer complete all as spd & directed.
Demolition and breaking of 150 mm dia drain pipe (salt glazed where AC or reinforced concrete) set in cement mortar complete all as specified & directed.
M&L for cement concrete 1:4:8 type C-2 using 40mm graded agg incl packing under and haunching against sides of 150mm dia (Internal dia) pipe after they are laid and tested complete all as specified (Thickness of concrete bed 150mm) complete all as specified & directed.
M&L for Reinforced concrete pipe class NP2, 150mm dia laid in trenches & jointed in cement mortar (1:2) with collars complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr depth for fdn etc for soft manhole not exc 10 sqm on plan and getting out any type of soil complete all as specified & directed.
S&F factory made SFRC drain cover 75mm thick size not exc .75sqm each complete all as specified and directed.
M&L for cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) in surface channels and drains finishing the exposed surfaces of concrete to fair and even including demolitions complete all as specified and directed.
Surface excavation n exc 30cm deep and averaging 15cm deep including getting out in hard/dense soil complete all as specificed and as directed by Engr-in-Charge.
M&L for 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base flooring complete all as specified and as directed.
M&L for Pre-polished machine pressed Chequered cement concrete tiles glossy finish 30cm x30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over and including 15mm thick screed bed in CM 1:6 and including dismetling old unsv tiles complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for brick work with sub class 'B' straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 20mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for RCC M-25 Design Mix as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC M-25 Design Mix as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild steel TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Use and Waste for Formwork to sides of pillars, posts, struts, piers, columns and stanchions as in Square, Circular rectangular on plan or polygonal shape complete all as specified and directed.
Use and Waste for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surface complete all as specified and directed.
M&L for rendering in 15mm thick ready mix mortar on brick or concrete surface and finishing the surface even and smooth complete all as specified and directed.
M&L for preparation of new plaster surfaces of walls and applying two coat of weather proof exterior acrylic emulsion paint over a coat of primer complete all as specified and directed.
S&F angle iron posts or struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. Note :- Size of angle shall be as per standard drgs.
S&F galvanised, 2 strand, steel barbed wire 2.24mm dia with 2mm barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (each line wire to be measured) complete all as specified and directed.
Concertina coil 1050mm dia, 56 loop, 2.5mm core wire heavy galvanished (wire-275 GSM & strip-200 GSM), tensile strengthof wire 1400-1500 N/Sqmm, wight 14.63 Kg/coil, stretchable length 12M including securing or tying at crossings with and provision of galvanised mild steel wire, staples ot steel pins etc complete all as specified and directed.
S & F of rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting and also fastening conforming to Fe-290 Gde E-165complete all as specified and directed.
Filling under floor, spreading and levelling in layers n exc 25cm thick well raming including watering as requred complete all as specified and directed
M&L for RCC M25 design mix using 20mm graded stone aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specifed and directed
M&L for RCC M25 design mix using 20mm graded stone aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for RCC M25 design mix using 20mm graded stone aggregate in Chajjas complete all as specifeid and directed.
Use and waste for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.for rough finish surface complete all as specifed and directed.
Use and waste for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finish surface complete all as specified and directed.
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening, complete all as specifed and directed.
Use and waste for Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specifed and directed.
M & L Cement concrete type B1 1:2:4 (20mm graded aggregate) and finished the surface even and smooth without using extra cement as in Floors and pavings, etc all as specified and as directed.
S & F of box type steel window with side hung shutters including box type hinges with steel handle, hold fast and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
Ditto as per item mentioned above but without glazing bars complete all as specified and directed.
S & F,rolling shutter with thickness of laths 1.25 mm including top cover, anchoring rod, hasp and staple and one shop coat of primer and erect with gear operated type with bevel gear box and crank handle, with 1.25 mm thick laths complete all as specified and directed.
M&L for sand bedding/cushioning in floor complete all as specified and as directed.
M&L for Ready Mix plaster 5mm thick on concrete surface of ceiling finished even and fair surface without using extra cement complete all as specified and as directed.
M&L for brick work in cement morta 1:6 using sub class B bricks, straight or curved on plan exc 6mtr mean radius complete all as specified and directed.
M&L for 40mm thick DPC on horizontal or vertical surface in PCC 1:2:4 type B0 using 12.5mm graded stone aggregate including necessary formwork and using WPC as per Manufacturer insruction complete all as specified and directed.
Preparation of newly plastered surface on wall and applying two coats of cement based paint over one coat of primer white or tinted complete all as specified and directed.
M&L for preparing surface of wall and applying two coat of white wash on ceiling complete all as specified and directed.
M&L for water proofing treatment to roof surface with APP water proofing membrane 3mm thick & weighing not less than 3.0 kg/sqm of approved make black finish & reinforced with non woven polyester matt of min 150 gm/sqm laid over a coat of bitumen primer conforming to IS-3384 @ 0.4 Ltr/sqm over prepared roof surfaces, forcing overlap with a propane or a butane gas torch with a overlap of 75mm at sides & 100mm at ends & sealing as per manufacturer's instructions complete all as spd and directed. Note :- 1. Water proofing treatment shall be got carried out by the manufacturer or their authorised applicator only. 2. Bitumen primer, bitumen and membrane shall be of same make/manufacturer. 3. The APP Membrane to be inserted in the parapet wall/wall by cutting chases of atleast 65X50mm size & making good in CM 1:3. complete all as specified and directed.
M&L for rendering 10mm thick cement mortar 1:4 on fair face of brick work or concrete surface on wall/roof surface including using WPC as per manufacturer instruction complete all as specified and directed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specifed and directed.
S&F 4mm thick pin headed, figured glass with oil putty in square n exc 0.50 sq m in each pane complete all as specified and directed.
M&L for minimum 80mm thick precast PCC interlocking blocks of grade M-35 single layer monolithic high density manufactured by electro vibro hydraulically operated block making machine confirming to IS-15658 : 2006 in equal proportion of grey and coloured tile to make a pattern as directed, laid over and including 20-25mm thick sand cusion complete all as specified and directed by Engineer-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down old MCCB , TPN DBs , SPN DBs, sp mcb & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed.
Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed.
Disconnecting elect connection and taking down of ceiling fan/ Exhaust fan of any make and any height, dismantling blade and removing fan alongwith blade for depositing in MES store yard complete all as specified and directed by Engr- in- Charge.
M&L point wiring complete with 1.5 Sqm single core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multi stranded copper conductor drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI) marked concealed in wall/fixed to roof, ceiling etc and incl provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, fabricated sunken terminal box made out of 1.60 mm thick sheet steel duly painted concealed in walls, with 3mm thick bakelite/PVC sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc, all as specified and as directed.
(a) One light /Ceiling fan/exhaust fan point controlled by one switch.
(b) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 2.5 sqmm FRLS 1100 Volts in New PVC concealed conduit medium grade ISI Marked not less than 20 mm dia in new M S steel terminal boxes modular including one run of using 1.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point, all as specified
Supply and fix in repair Sub main wiring complete with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 4 Sqmm in and including new PVC conduit medium grade not less than 20 mm dia, for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 2.5 Sqmm size stranded conductor as earthwire complete all as specified and directed.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories(Concealed)/ Surface in walls all as specified and as directed.
M&L switch Modular type 6 Amp SP one way ISI marked ccomplete all as specified and directed.
M&L switch Modular type type 16 Amp SP one way, ISI marked complete all as specified and directed.
M&LModular type socket outlet 5 pin 6 Amp flush type, ISI marked complete all as specified and directed.
M&L Modular type socket outlet 2 in 1,5 pin 6/16 Amps, ISI marked complete all as specified and directed.
M&L ceiling rose 3 phase PVC polycorbonate,isolated body, complete all as specified and directed.
S & F Modular electronic fan regulator step type,2 module ,360 degree rotation complete all as specified and directed by engr-in charge.
M&L for earthing of machinery/equipment/panel/installed at power house/subatation, complete with galvanised steel earth palte electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.5 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to galvanised iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth protected by 40 mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No.3 of SSR Part-I )2009) and testing on completion all as specified and directed.
Supply and fix in replacement MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and directed by engr-in charge.
Supply and fix in replacement MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and directed by engr-in charge.
M&L MCB SPN 40 Amp "B" curve, 10 kA complete all as specified and directed by engr-in charge.
M&L MCB SP 6 to 32 Amp "B" curve ,10 kA. complete all as specified and directed by engr-in charge.
Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.90, THD< 20%, colour temperature - 6500K, surge protection 3KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 105 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixedcomplete all as specified and directed by engr-in charge. ..
Supply and fix in replacement LED batten luminaire surface mounted 2 feet system wattage of 9-10 watts and not less than 900 lm system lumen output with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.90, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix in replacement 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary - is >100lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%,THD<20%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&f in replacemnt exhaust fans metal body AC single phase 230/240 V of size 300 mm sweep, Air flow rate > 900cum/min, Bird screen for protection against birds, double ball bearing, metal body with louvre with louvre for fixing of exhaust fan complete all as directed by Engr-in-Charge.
M&L for breaking the old existing wall and making provn of a round hole for fixing of 300 mm sweep exhaust fan including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed.
Supply and fixing new BLDC fan against old ceiling fans three blade, Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5 star rating for energy saving, rated Air delivery >220 cum/min, AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible, copper cable pvc insulated of suitable length, complete all as directed. Note BLDC Fan should work on existing electronic fan regulator.
Provn of modular box type metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall with sutable sand and cement, complete all as specified and directed.
Provn of water heater storage type Geyser vertical type with suitable size of fastner and including provision and connecting up of SS braidedpipe with adopter for inlet and outlet water connection having edjustable knob for temperature control and inner tank should be glass line coated, capacity 25 Ltrs, having heating element 1.5 KW and not less than 5 star rating, suitable for ,230 volt, 50 Hz electric supply complete all as specified and directed .
S & F in replacement pressure die cast aluminium housing LED street light luminaires with IP66 deg. of protection suitable for 35 watt LED fitting duly fixed on 40 mm dia GI mast including 50X 6 mm thick MS flat with suitable size of fastner including making connection flexible copper conductor cable from ceiling rose to fitting complete all as specified and directed. Note : The Contractor quoated the rates incl all accessories like suitable GI pipe mast, 50x6 mm thick MS flat, fashner, nut & bolts, suitable length of flexiable wire complete all as specified and directed by engr-in charge.
Provn of Wall mounted fans AC single phase 230/240 V, of size 400 mm sweep, speed RPM 1400,Sturdy and shock proof body for fixing of wall fan complete all as specified and directed by engr-in charge.
Provn of LED 2 X 2 ft backlite surface mounted fitting 36/40 Watts including connecting up with necessary PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed complete all as specified and directed by engr-in charge.
Supply & fix in repair factory made epoxy powder coated Distribution Board VTPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one VTPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623. complete all as specified and directed by engr-in charge.
M&L in replacement MCCB 125 Amps, 16 KA , 4P, 415 Volts, 50Hz , with thermal magnetic setting complete all as specified and directed by engr-in charge.
S&F modular type AC box single pole and Neutral with a two pin earth plug and socket complete with a mini MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall with sutable sand and cement, complete all as specified and directed.
S & F water heater storage type Geyser vertical type with suitable size of fastner and, inner tank material of superior glass line tank and outer body material of ABS with high pressure with standing enabling (up to 8 bar pressure) capacity including provision and connecting up of SS braidedpipe with adopter for inlet and outlet wwater connection having edjustable knob for temperature control and inner tank should be glass line coated, capacity 25 Ltrs, having heating element 1.5 KW and not less than 5 star rating, suitable for ,230 volt, 50 Hz electric supply complete all as specified and directed .
M&L glazed ceramic coloured tiles of size 350x250mm/450 x 350 x 7 mm thick on vertical surfaces laid over plaster 10mm thick in CM 1:4 as in skirting/dados on vertical surfaces complete all as specified and directed .(Note Tiles dimension & Pattern shall match with existing tiles)
S&F 15mm bore galvanised iron pipe medium grade with all fittings fixed to wall / ceiling or laid in floor including connections complete all as specified and directed.
S&F bib tap 15mm bore of cast copper alloy (heavy duty) CP fancy type scrwed to iron pipe and fixed complete all as specified and directed.
S&F stop cock of 15 mm dia cast copper alloy (heavy duty) CP fancy type screwed for iron pipe and fixed complete all as specified and directed.
Cutting chases for concealed water tubing or concealed conduct wiring etc and making good cutting n exc 10cm girth in brick wall complete all as specified and directed.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
PS115.pdf
Tender Documents • 1.11 MB
BOQ_835615.xls
BOQ • 1.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .