Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹67.9 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹69.0 L+₹1.0 L (1.50%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹49.5 L−₹18.5 L (27.2%)Rejected-Finance | L-3 | Rejected-Finance L-3 | |
| 4 | Rejected-Technical 6A GAU KRIPA MOHKAMPUR PHASE 1 INDUSTRIAL AREA DELHI ROAD MEERUT UTTAR PRADESH 250002 | MEERUT | UTTAR PRADESH | 250002 | - | Rejected-Technical Document not as per requirement | |
| 5 | Rejected-Technical 00 HAIDARPUR JAMALPUR ROAD SADAR JAUNPUR UTTAR PRADESH 222001 | JAUNPUR | UTTAR PRADESH | 222001 | - | Rejected-Technical Document not as per requirement |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
20 Nov 2019, 12:00 pmClosed
SE
132 KV S/S Ghazipur
WORK STRINGING OF QUADRUPLE MOOSE BUNDLE CONDUCTOR FOR 132 KV MAIN-BUS-I, II AND DOUBLE MOOSE BUNDLE CONDUCTOR FOR 132 KV AUXILIARY-BUS OF ICT-I, II and III BAY AT THE PLACE OF EXISTING BUS-BAR AT 400 KV S/S KASARA-MAU
2019_UPTCL_392993_1
E-tender No. 84 ETC(GZP)/2019-20
Open Tender
Electrical Works
Item Rate
120 days
Mau
Please refer Tender documents.
2 documents required · 2 mandatory
₹8,260
EE ETD-II Varanasi
₹70,000
8 Jan 2020
17 Oct 2019
20 Nov 2019
17 Oct 2019
20 Nov 2019
17 Oct 2019
Amount
PART-A(SUPPLY)
Bolted type double tension fittings suitable for quadruple moose bundle conductor with complete hardware fittings (Turn buckle, arching horn, D-shackle, ball hook, I-sockets, tension clamp, nut-bolt & washer) for 132 KV Main bus-bar having 2x10 Nos. 120/70 KN Disc insulator strings. As per BIS 2486 part-I
Spacer made of aluminum alloy for quadruple moose bundle conductor for 250x250 mm spacing for 132 KV system As per BIS5561 Part-I
Spacer made of aluminum alloy for double moose bundle conductor for 250 mm spacing for 132 KV system As per BIS5561 Part-I
132 KV quadruple moose trapeze made of LM-6 aluminum alloy suitable for 250 mm spacing & jumpring with moose conductor, complete with nut-bolt &washer As per BIS5561 Part-I
132 KV Isolator clamp (T-type) made of LM-6 aluminum alloy suitable for twin moose conductor complete with nut-bolt & washer (To be fix in vertical & horizontal mode ) As per BIS5561 part-I
132 KV C.B. clamp (T-type) made of LM-6 aluminum alloy suitable for twin moose conductor complete with nut-bolt & washer (suitable for one side connect moose conductor and another side breaker terminal plate) As per BIS5561 part-I
132 KV C.T. clamp (T-type) made of LM-6 aluminum alloy suitable for twin moose conductor complete with nut-bolt & washer (suitable for one side connect moose conductor and another side C.T. terminal stud) As per BIS5561 part-I
132 KV P.T. clamp (T-type) made of LM-6 aluminum alloy suitable for twin moose conductor complete with nut-bolt & washer (suitable for one side connect moose conductor and another side P.T. terminal stud) As per BIS5561 part-I
132 KV L.A. clamp (T-type) made of LM-6 aluminum alloy suitable for twin moose conductor complete with nut-bolt & washer (suitable for one side connect moose conductor and another side L.A. terminal stud) As per BIS5561 part-I
132 KV P.I. clamp (T-type) made of LM-6 aluminum alloy suitable for twin moose conductor complete with nut-bolt & washer (suitable for upper side connect moose conductor and another base side on P.I. head) As per BIS5561 part-I
P.G. clamp made of LM-6 aluminum alloy suitable for moose to moose conductor as per BIS5561 part-I
132 KV ICT bushing terminal clamp (T-type) made of LM-6 aluminum alloy suitable for twin moose conductor complete with nut-bolt &washer.(suitable for one side connect moose conductor and another side ICT terminal bushing stud of 132
Heavy duty stainless steel made nut-bolt & washer in following size
PART-B(WORK)
Dismantling of existing twin moose Main bus bar I &II having span 36 meter. The including works, opening of all jumpers from Main bus to bus side isolator, tedem isolator, tension fittings, disc insulator string set, double moose spacer and double moose Main bus-bar conductor then rolling of dismantled moose conductor. (One phase double moose conductor per section to be treated one job)
Dismantling of existing single moose jumpers from C.B. to isolator and re-jumprings at its place during stringing of Main bus-bar –II of quadruple moose bundle conductor. (One phase single moose conductor per section to be treated one job)
Stringing of quadruple moose bundle conductor of 132 KV Main bus-bar –I &II having span 36 meter. The including work cutting of moose conductor, hoisting of 2x10 Nos. disc insulator string, mounting of tension fitting at both end, stringing of bus moose conductor, fixing of quadruple moose spacer 250x250 mm spacing for 132 KV system and all other associated work.
Stringing of double moose bundle conductor of 132 KV Auxiliary bus-bar ICT-I, II bays having span 48/36/24 meter. The including work cutting of moose conductor, hoisting of 2x10 Nos. disc insulator string, mounting of tension fitting at both end, stringing of bus moose conductor, fixing of double moose spacer 250 mm spacing for 132 KV system and all other associated work.
Jumpering from Main bus-bar-I &II to isolator with double moose conductor. The including work cutting of proper size jumper, bending, fixing main bus-bar to isolator and fixing of spacer for 250 mm spacing in double moose conductor and all other associated work.
Jumpering from auxiliary bus-bar to isolator, C.T.,P.T.,L.A. and C.B. with double moose conductor. The including work cutting of proper size jumper, bending, fixing auxiliary bus-bar to equipment with making Y-shape joint and fixing of spacer for 250 mm spacing in double moose conductor and all other associated work.
Inter connection between main bus section to main bus section with quadruple moose bundle conductor and all other associated work.
Inter connection between auxiliary bus section to auxiliary bus section with double moose bundle conductor and all other associated work.
Shifting of moose conductor drums, hardware, fittings, clamps, spacer, nut and bolt from store to work site of 132 KV switchyard and also shifting old and used rolled moose conductor, dismantled hardware, fittings, clamps etc. from work site to store and all other associated work.
Meena Elect and Engg Works
NIRMAL ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .