Loading…
Loading…
Tender Value
₹71.2 L
EMD Value
₹1.4 L
Closing Date
23 Oct 2026, 3:30 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
ELECTG
14 conditions · 2 needing a document upload
The tenderer must have minimum average annualcontractual turnover of V/N or "V" whichever is less;where V= Advertised value of the tender in croresof Rupees, N= Number of years prescribed forcompletion of work for which bids have beeninvited. The average annual contractual turnovershall be calculated as an average of "totalcontractual payments" in the previous threefinancial years, as per the audited balance sheet.However, in case balance sheet of the previous yearis yet to be prepared/ audited, the audited balancesheet of the fourth previous year shall beconsidered for calculating average annualcontractual turnover. The tenderers shall submitrequisite information as per Annexure-VIB, alongwith copies of Audited Balance Sheets duly certifiedby the Chartered Accountant/ Certificate fromChartered Accountant duly supported by AuditedBalance Sheet. (For details, please refer para 10.2of Financial Eligibility Criteria of Annexure - I ofTender form 2nd sheet).
The tenderer must have successfully completed orsubstantially completed any one of the followingcategories of work(s) during last 07 (seven) years,ending last day of month previous to the one inwhich tender is invited: (i) Three similar works eachcosting not less than the amount equal to 30% ofadvertised value of the tender, or (ii) Two similarworks each costing not less than the amount equalto 40% of advertised value of the tender, or (iii)One similar work costing not less than the amountequal to 60% of advertised value of the tender. (Fordetails please refer para 10.1 of Technical EligibilityCriteria of Annexure - I of Tender form 2nd sheet).(Note: Work experience certificate from privateindividuals shall not be considered. However, inaddition to work experience certificates issued byany Govt. organization, work experience certificateissued by Public listed company having averageannual turnover of Rs. 500 crore and above in last 3FY excluding the current financial year, listed onNSE or BSE, incorporated / registered at least 5years prior to the date of opening of tender, shallalso be considered provided the work experiencecertificate has been issued by a person authorizedby the Public listed company to issue suchcertificates.
Similar nature of work: Supply and / or erection / installation, testing & commissioning of Electrical assets pertaining to HT and / or LT & HT power supply systems such as substations (with / without supply of transformers / sub-station equipments), HT panels, laying of LT and HT cables, laying of HT overhead lines, light poles, high masts including luminaries, earthing of electrical equimpments, straight through jointing and end termination of LT / HT systems etc.
60 conditions · 15 needing a document upload
Whether Document verification certificate as per standard format uploaded
Whether electrical contractor's license, supervisor's license along with PAN Card of both contractor and supervisor uploaded.
Whether documents related to all mandatory requirements as mentioned in Clause no 5 & 6 of GCC part -I, Clause no 10, 11, 14, 15 & 16 of tender form 2nd sheet have been full filled and uploaded.
Whether documents relating to exemption of payment of EMD enclosed
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer should upload copy of the following documents self-attested / digitally signed by the tenderer or authorized representative of the tendering firm along with the tender. Tenderer(s) can use Standard formats available in the tender documents.
The list of personnel / organization on hand and proposed to be engaged for the tendered work. (Please refer Para-11(iii) of tender form 2nd sheet). Standard format attached as form no.5 in tender documents.
The list of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work. (Please refer Para- 11(iii) of tender form 2nd sheet).
List of works physically completed in the last 03(three) financial years under Govt./Public Sector Units giving description of work, organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and final value of contract should also be given.
List of works on hand indicating description of work, contract value, approximate value of balance work yet to be done and date of award. (Please refer Para-10.1 of tender form 2nd sheet). Standard format attached as form no.3 in tender documents.
NOTE: Supportive documents/certificates from the organizations with whom they worked/are working should be uploaded. 2.4.1 Certificates from private individuals for whom such works are executed/being executed shall not be accepted. refer clause No.10.1 of IRGCC-2022.
The tenderer should upload the supportive documents against the i)'Type of Firm' as mentioned below: *Sole Proprietorship firm: Notarized affidavit claiming the firm to be a sole proprietor firm * Company: MOA, AOA, Power of Attorney, *Partnership Firm: Deed of Partnership, POA and ii) an undertaking for not being Blacklisted / debarred as per Annexure-A. NOTE: In case of partnership firm, they should submit individual declaration of all partners not being Blacklisted / Debarred as per Annexure-A, otherwise the offer of the tenderer will be summarily rejected.
Each partner of the partnership firm should duly submit the filled in Annexure-V separately as per IRGCC-2022; Otherwise, the offer of the tenderer will be summarily rejected. Firms other than the partnership firm have to submit it as before.
Please upload certificate (Annexure - V(A)) and is to be given by attorney/authorized signatory/ each member of Partnership firm/ Joint Venture (JV)/ Hindu Undivided Family (HUF)/ Limited Liability Partnership (LLP) etc).
The tenderer should upload Declaration regarding "Employment / partnership etc. of Retired Railway Employees" (please refer to Para 16(a) of tender form 2nd sheet). (Use standard "Form no. 2", available in tender booklet).
The tenderer has to upload Declaration regarding relation with any Railway Employees. (Please refer to Para 16 (c) of tender form 2nd sheet). (Use standard "Form no. 6", available in tender booklet).
Should a tenderer or contractor being an individual, have member(s) of his family or in the case of partnership firm / Company / Joint Venture(JV) / registered Society / registered trust etc. one or more of his partner(s) / share holder(s) or member (s) of the family of patterner(s) / share holder (s) having share of more than 1 % in the tendering entity employed in gazetted capacity in the engineering or any other department of the Railway, then the tenderer at the time of submission of tender, will inform the authority inviting tenders the details of such persons.
The tenderer should upload certificate of familiarization as per Chapter -4. (Use standard "Form no. 7", available in tender booklet).
The tenderer should upload GST registration certificate and PAN card.
For all tenders having advertised cost of Rs. 10 lakh or above, the contractor shall have to submit the option to take payment from Railways through a letter or credit (LC arrangement. The tenderer shall affirm having read over and agreed to the terms and condition of the LC option. The option of taking payment through LC arrangement, once exercised by tenderer at the time of bidding, shall be final and no change shall be permitted, therafter, during execution of contract (The tenderer have to submit the option take payment fro Railway through a Letter of Credit arrangement).
The tenderer should upload the bank details i.e. Name of Bank along with Bank Branch Code, Account Number as appearing in the cheque book, IFSC Code and PAN Number, dully certified by the Authorized official of of the bank to facilitate payment through ECS/NEFT/RTGS. In lieu of the bank certificate photocopy /scanned copy of a cancelled cheque and PAN card may be attached for verification of the above particular.
ELECTRICAL GENERAL WORKS IN CONNECTION WITH AUGMENTATION OF INFRASTRUCTURE FOR SATELLITE DEPOT AT BALANGIR IN CONNECTION WITH MECHANIZATION OF TRACK MAINTENANCE.
SBP-ELECT-2026-T-299~ECOR
SBP-ELECT-2026-T-299
Open
Works - General
6 Months
Sambalpur, Odisha
₹0
₹1.4 L
1 Oct 2026
1 Oct 2026
9 Oct 2026
180 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 71,18,949.4 | ||
| — | 2.00 | — | — | ||
| Supply of Lightening Arrestor for 11kV ,5kA. (1 set=3 nos) | — | — | — | 6,732.4 | |
| — | 2.00 | — | — | ||
| Erection,testing and commissioning of Lightening Arrestor for 11KV. (1 set=3 nos) | — | — | — | 1,552.82 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of Heat shrinkable outdoor type end termination jointing kit for 11KV(E) XLPE cable 3x 50 sq. mm. | — | — | — | 48,558.64 | |
| — | 6.00 | — | — | ||
| Supply and fixing of Heat shrinkable indoor type end termination cable joint kit for 11 KV (E) XLPE 3x50 sq. mm cable. | — | — | — | 51,886.02 | |
| — | 10.00 | — | — | ||
| Supply and spreading of sand | — | — | — | 8,203.7 | |
| — | 10.00 | — | — | ||
| Supply & spreading of 25-40 mm size ballast over sub-station area and dressing the ballast to a proper profile as instructed by Rly. Site engineer. | — | — | — | 16,420.2 | |
| — | 2.00 | — | — | ||
| Supply, erection, Testing &commissioning of Sub-station Name board of size (18"x24") with stickering indicating capacity & location of Sub-station. | — | — | — | 4,765.94 | |
| — | 2.00 | — | — | ||
| Supply and fixing of portable fireextinguishers with DCP (ABC) of 06 Kg capacity as per IS:15683/2006. (reaffirmed 2012) amendment No3 or latest, with carrying handle and mounting bracket | — | — | — | 4,282.54 | |
| — | 2.00 | — | — | ||
| Supply &fixing of sand bucket with suitable stand. | — | — | — | 5,061.32 | |
| — | 60.00 | — | — | ||
| Supply & erection of fencing panels at substation | — | — | — | 2,01,439.2 | |
| — | 1.50 | — | — | ||
| Supply & erection of fencing uprights | — | — | — | 2,21,873.07 | |
| — | 2.00 | — | — | ||
| SITC of protected area Boards | — | — | — | 2,427.56 | |
| — | 4.00 | — | — | ||
| Supply of 200x100mm,11Mtr Rs joist | — | — | — | 73,309.32 | |
| — | 450.00 | — | — | ||
| Supply, fabrication &erection of G.I.channel / G.I. angle /Supply, erection of G.I.Nuts,bolts, washers etc of suitable size. | — | — | — | 46,206 | |
| — | 1.00 | — | — | ||
| Supply of 11KV, 200A gang operated AB switch (Vertical type) complete. | — | — | — | 6,726.19 | |
| — | 1.00 | — | — | ||
| Erection, testing and commissioning of AB switch | — | — | — | 1,635.1 | |
| — | 10.00 | — | — | ||
| Painting of poles | — | — | — | 2,930.3 | |
| — | 300.00 | — | — | ||
| Fabrication, Supply, Installation, testing and commissioning of APFC panel | — | — | — | 2,47,455 | |
| — | 1.00 | — | — | ||
| SITC of 400A 4 Pole Change over switch confirming to IS/IEC 60947-3, with sheet streel enclosure | — | — | — | 70,433 | |
| — | 1.00 | — | — | ||
| Supply, erection, testing and commissioning of main distribution panel including copper bus bar, incomer 2x 800A MDO type ACB as bus coupler. Outgoing 8 nos 250A MCCB and 2 nos 100A MCCB with all accessories. | — | — | — | 11,63,306.7 | |
| — | 1.00 | — | — | ||
| Supply of outdoor feeder pillar/ Panel Board having 2x250A MCCB, 4pole,25KA as incomer, (electrically interlocked 400 A copper bus bar, multifunction energy meter in incoming, 2 X 100 A MCCB 16KA, 2x63 Amp MCCB 16KA as outgoing (For MCCB's Ics= 100% Itu) | — | — | — | 2,92,424.06 | |
| — | 2.00 | — | — | ||
| Supply of outdoor feeder pillar/ Panel Board having 1x160A MCCB,16KA as incomer, 200 A copper bus bar, multifunction energy meter in incoming, 4 X 40-63 A MCCB 16KA, 2x32Amp MCB DP 10KA as outgoing (For MCCB's Ics= 100% Icu) | — | — | — | 1,68,225.86 | |
| — | 2.00 | — | — | ||
| Supply of outdoor feeder pillar/ Panel Board consisting of copper bus bar 100Amp having I/C: 1x63A MCCB 4P, 10KA in incoming, outgoing:10x40A MCB DP 10KA C series (For MCCB's Ics= 100% Icu) | — | — | — | 76,529.1 | |
| — | 5.00 | — | — | ||
| Fixing, testing and commissioning of LT Outdoor feeder pillar/panel of different size on wall or ground. | — | — | — | 20,948.95 | |
| — | 3.00 | — | — | ||
| Supply and erection of outdoor type 500mmx400mmx250mm approx. with Busbar capacity 200A. | — | — | — | 13,069.98 | |
| — | — | — | box | ||
| — | 6.00 | — | — | ||
| Supply & fixing of outdoor/indoor type junction box of size:400x300x250mm with 3 phase 100A busbar and 100A 4pole isolator. | — | — | — | 29,191.68 | |
| — | 400.00 | — | — | ||
| Laying of cable across road/track using trenchless construction method | — | — | — | 13,66,912 | |
| — | 200.00 | — | — | ||
| Laying of HT/LT single cable across the road/Track as per Railway appd drawing. | — | — | — | 91,044 | |
| — | 300.00 | — | — | ||
| Laying of cable on hard surface on platform/any cement concrete | — | — | — | 1,20,393 | |
| — | 1100.00 | — | — | ||
| Supply and laying of 160 mm dia DWC HDPE pipe (ISI marked) along with all accessories as per CPWD specification | — | — | — | 3,71,261 | |
| — | 700.00 | — | — | ||
| Supply and laying of 63 mm dia DWC HDPE pipe (ISI marked) along with all accessories as per CPWD specification. | — | — | — | 1,12,462 | |
| — | 60.00 | — | — | ||
| Supply and fixing of 100 mm inner dia (medium grade) GI pipe | — | — | — | 62,617.2 | |
| — | 30.00 | — | — | ||
| Supply and fixing of 65 mm inner dia (medium grade) GI pipe | — | — | — | 17,482.2 | |
| — | 3600.00 | — | — | ||
| Laying of cable in air/on wall/pole / through GI Pipe/culvert/cable trench/HDPE pipe etc. | — | — | — | 80,748 | |
| — | 120.00 | — | — | ||
| Supplying and making of cable route marker. | — | — | — | 49,040.4 | |
| — | 66.00 | — | — | ||
| Cutting of earth for plinth modifications/ boundary wall/concrete trench etc. | — | — | — | 14,625.6 | |
| — | 40.00 | — | — | ||
| Brick work with common burnt clay F.P.S. (non-modular) bricks ofr class designation 7.5 in superstructure above plinth level up to floor level in all shapes and size in: cement mortar1:6 (1 cement:6 coarse sand) | — | — | — | 2,66,665.2 | |
| — | 240.00 | — | — | ||
| 12 mm cement plaster of mix in ratio 1:6 (1 cement:6 fine sand) | — | — | — | 53,594.4 | |
| — | 19.60 | — | — | ||
| Providing of cement concrete 1:5:10(1 cement :5 fine sand:10 graded stone aggregate 40 mm size) | — | — | — | 90,491.44 | |
| — | 200.00 | — | — | ||
| Supply & fixing of RCC cover for concrete cable trench of size 600x1000X75(WxLxH) (suitable for 450mmx450 mm trench.) | — | — | — | 1,42,826 | |
| — | 160.00 | — | — | ||
| Concealed wiring for Light/ Fan/ Exhaust Fan/Call Bell/ Points by 1.5 sq. mm FRLS Cu. Wire with modular switches. | — | — | — | 80,260.8 | |
| — | 500.00 | — | — | ||
| Concealed wiring of sub main with 2(1x2.5 sq.mm) + 1x (1.5 sq.mm) PVC Cu. FRLS Wire | — | — | — | 54,075 | |
| — | 250.00 | — | — | ||
| Concealed wiring of sub main with 2(1x4 sq.mm) + 1x (2.5 sq.mm) PVC Cu. FRLS Wire | — | — | — | 29,492.5 | |
| — | 130.00 | — | — | ||
| Concealed wiring of sub main with 2(1x6 sq.mm) + 1x (2.5 sq.mm) PVC Cu. FRLS Wire | — | — | — | 21,334.3 | |
| — | 100.00 | — | — | ||
| Supply & drawing of 1.5 sq mm PVC Cu. FRLS Wire | — | — | — | 3,990 | |
| — | 150.00 | — | — | ||
| Surface wiring of sub main with 2(1x 6 sq.mm) + 1x (2.5 sq. mm) PVC Cu. FRLS Wire. | — | — | — | 30,694.5 | |
| — | 20.00 | — | — | ||
| Supply and fixing of ceiling rose for light/fan and signage point | — | — | — | 401 | |
| — | 20.00 | — | — | ||
| Supply and fixing of PVC circular box/RJ box/square junction box on truss | — | — | — | 1,076.2 | |
| — | 45.00 | — | — | ||
| Concealed wiring of 6Amp 5/3 pin socket point (modular type switch and socket) | — | — | — | 5,586.3 | |
| — | 20.00 | — | — | ||
| Concealed wiring of 16Amp 5/3 pin socket point (modular type switch and socket) | — | — | — | 7,345.4 | |
| — | 3.00 | — | — | ||
| Supply and erection of 4 Way MCB distribution Board | — | — | — | 2,161.8 | |
| — | 4.00 | — | — | ||
| Supply and erection of 8-way MCB distribution Board | — | — | — | 3,730.52 | |
| — | 4.00 | — | — | ||
| SITC of 6-32Amp MCB DP, 10KA. | — | — | — | 2,089.24 | |
| — | 36.00 | — | — | ||
| SITC of 6-32Amp MCB SP, 10KA. | — | — | — | 8,418.96 | |
| — | 21.00 | — | — | ||
| Supply of Inverter tube light 20 Watt | — | — | — | 10,206 | |
| — | 61.00 | — | — | ||
| Supply of Indoor LED tube light Fitting 20 watt. | — | — | — | 16,719.49 | |
| — | 6.00 | — | — | ||
| Supply of 9-Watt LEDBulkhead fitting | — | — | — | 5,296.26 | |
| — | 180.00 | — | — | ||
| Supply of LED down light fittings complete with luminaire (Watt should be considered as Per Unit). | — | — | — | 14,040 | |
| — | 2.00 | — | — | ||
| "Supply of Night lamp (4MLED Footlight warm white)" | — | — | — | 1,672.06 | |
| — | 118.00 | — | — | ||
| Fixing, testing and commissioning of LED tube Light/bulkhead fitting/Down lighter. | — | — | — | 5,413.84 | |
| — | 18.00 | — | — | ||
| Supply& erection of 120W LED flood light | — | — | — | 69,120 | |
| — | 20.00 | — | — | ||
| Supply, erection, testing and commissioning of 150-Watt LED High Bay light fitting. | — | — | — | 1,40,450.2 | |
| — | 35.00 | — | — | ||
| Supply of 1200 mm sweep 5 star rated BLDC Ceiling fan complete | — | — | — | 80,148.6 | |
| — | 35.00 | — | — | ||
| Fixing, testing and commissioning of AC ceiling fan | — | — | — | 1,457.75 | |
| — | 18.00 | — | — | ||
| Supply of wall mounted Air circulating fan 750mm sweep | — | — | — | 1,53,657.72 | |
| — | 18.00 | — | — | ||
| Fixing, testing of wall mounted Air circulating fan 750mm sweep | — | — | — | 15,365.88 | |
| — | 17.00 | — | — | ||
| Supply of 300 mm sweep Exhaust fan | — | — | — | 25,956.96 | |
| — | 17.00 | — | — | ||
| Fixing, testing and commissioning of Exhaust fan | — | — | — | 3,554.87 | |
| — | 2.00 | — | — | ||
| Supply erection, testing and commissioning of call bell. | — | — | — | 202.5 | |
| — | 1.00 | — | — | ||
| Installation, testing and Commissioning of Split AC (1.5/2 Ton capacity) | — | — | — | 1,949.1 | |
| — | 1.00 | — | — | ||
| Supply and fixing of metallic mount Suitable for High Wall Split AC complete | — | — | — | 1,037 | |
| — | 3.00 | — | — | ||
| Supply and installation Refrigerant Pipe (1/2") For Air Conditioners Suitable for 1.5 Ton including brazing and wrapping of thermal insulation. | — | — | — | 2,140.44 | |
| — | 1.00 | — | — | ||
| Supply & fixing of 16-25A Modular AC starter with 16Amp modular MCB SP C curve to be fitted modular Box and cover | — | — | — | 1,762 | |
| — | 2.00 | — | — | ||
| Supply and fixing of instant water heater | — | — | — | 13,180 | |
| — | 14.00 | — | — | ||
| Supply of outdoor type LED 3D light fitting 16W, 48V of standard size with LED light confirming with IP 67 and IK 10 water and dust proof, impact protection, protection from reverse polarity, short circuit, open circuit with Toughened glass with prismatic diffuser etc. for under pit lighting suitable for surface/recess mounting similar to model IR GOLDC2 of Goldwyn make or similar reputed make, warranty-5 years. | — | — | — | 32,178.44 | |
| — | 12.00 | — | — | ||
| Supply of outdoor type LED light fitting 22W,48V of standard size along with LED light confirming with IP 65 and IK 10 water and dust proof for catwalk light (Model IR GOLDB1 of Goldwyn make or similar reputed make, warranty-5 years. | — | — | — | 42,781.44 | |
| — | 26.00 | — | — | ||
| Fixing, testing and commissioning of LED luminaries with required GI/SS fasteners. | — | — | — | 5,975.84 | |
| — | 1.00 | — | — | ||
| SITC of rainproof outdoor type Step down transformer of capacity 2 kVA, 230V/48V, 50Hz, AC with MCB(DP) of 16A, 230V on incoming side and 40A DP MCB on outgoing side. | — | — | — | 5,382.94 | |
| — | 20.00 | — | — | ||
| Supply & erection of CEE type insulated, interlocked 63 Amp 5 pin, socket & plug system fitted with 63 Ams 4 pole, breaking capacity-10 kA, MCB including internal wiring & other accessories. | — | — | — | 2,69,086.2 | |
| — | 20.00 | — | — | ||
| Supply of 32 A,3P+N+E interlocked sockets, IP 67 with watertight plug AND 32 A TPN MCB complete | — | — | — | 99,929.6 | |
| — | 1.00 | — | — | ||
| Supply and erection of RCBO 6-32 Amp, 02 pole 240V AC,50Hz with 30 mA sensitivity, 10 KA, conforming to IS:12640-2 with enclosure. | — | — | — | 3,298.02 | |
| — | 30.00 | — | — | ||
| Provision of G.I pipe earthing as per CEE approved drawing | — | — | — | 85,014 | |
| — | 150.00 | — | — | ||
| Supply and fixing of GI Flat | — | — | — | 11,923.5 | |
| — | 8.00 | — | — | ||
| Supply of single arm GI Octagonal pole 6 mtr height complete | — | — | — | 59,943.52 | |
| — | 12.00 | — | — | ||
| SITC of Coil Earthing | — | — | — | 1,768.92 | |
| — | 12.00 | — | — | ||
| Transportation and Erection of GI/SST pole | — | — | — | 3,088.8 | |
| — | 10.40 | — | — | ||
| Excavation of pit and cement concreting in ratio 1:3:6(cement: sand: ballast) for erection of Pole | — | — | — | 35,609.5 | |
| — | 10.00 | — | — | ||
| Supply of 45-watt LED outdoor light fitting complete | — | — | — | 20,671 | |
| — | 10.00 | — | — | ||
| Fixing, testing and commissioning of LED outdoor fitting on SST/GI pole | — | — | — | 2,553.4 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
IRGCC2022WorkscompressedLatest.pdf IR GCC 2022 Works compressed Latest
ATTACHMENT
T-299-TenderBooklet.pdf
ATTACHMENT
IRGCC2022WorkscompressedLatest.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .