| 1 | L1₹11.7 LAccepted-AOC | ₹11.7 L Quoted ₹12.0 L | L1 | Accepted-AOC The L1 bidder has quoted has less Percentage |
| 2 | L2₹12.2 LRejected-Finance 2 1068 MALLIGAI STREET EZHIL NAGAR IYER BUNGALOW MADURAI 625014 | MADURAI | TAMIL NADU | 625014 | ₹12.2 L | L2 | Rejected-Finance The L2 bidder has quoted has Excess Percentage |
| Sl No | Description | Qty | Unit | PR & CO L2 | S.SENTHIL L1 |
|---|---|---|---|---|---|
| 1.00 | clean removal of cement plaster from walls | 106.4 | m2 | 10 ₹1,064 | 9.1 ₹968.24 |
| 2.00 | Dismantling, clearing away and carefully stacking materials useful for re-use for Pressed tiles & weathering course. | 72.7 | m2 | 55 ₹3,998.50 | 50 ₹3,635 |
| 3.00 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of plain cement concrete. | 6.5 | m3 | 530 ₹3,445 | 527 ₹3,425.50 |
| 4.00 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers. - Mixing by manual means | 6.5 | m3 | 5,570 ₹36,205 | 5,459 ₹35,483.50 |
| 5.00 | Easing the existing over hanging doors and windows including nerewing frame its position and refixing the same after attending petty repair works including for wrough and putup in position fixing necessary furniture excluding cost of aurniture etc., complete complying with standard specification as directed by the departmental officers at site of work. | 25.2 | m2 | 485 ₹12,222 | 478 ₹12,045.60 |
| 6.00 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. | 8.25 | m3 | 4,280 ₹35,310 | 4,195 ₹34,608.75 |
| 7.00 | Finishing the top of roof with one course of machine pressed tiles of following size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. | 81.2 | m2 | 1,350 ₹1.1 L | 1,342 ₹1.1 L |
| 8.00 | Paving the Floor with Matt finish Vitrified Tiles of size 600 x 600 x 8mm in all floors over a base layer of cement mortar 1:3 (One Cement and Three M-sand) 20mm thick and pointing with the same coloured cement neatly and fixed in position so as to make it perfectly smooth and shining to the alignment etc., complete complying with standard specification and as direted by the departmental officers. (The sample of colour and shade of the ceramic tiles should be got approved by Executive Engineer before use on works) | 72.9 | m2 | 1,660 ₹1.2 L | 1,655 ₹1.2 L |
| 9.00 | Chipping and removing the existing delaminated portion of the concrete surface such as beams columns, ceiling etc.,to the required depth and exposting the rods and dismantled area shall be thoroughly cleaned using sand plaster and wash the surface and steel rebars to remove ball loose particles and additional reinforcement be provided if required and bnoth the existing and new reinforcemnt rods shall be provided with two coats of TEC BEAT ZR Exit Zinc Rich reinforcement Coating system and Mixing and applying mineral based cementations bonding coat Tec bond SBR by brush to the revetted treatment surface and applying coarse repair mortar (Cement mortar mixed with chips) Mixed with the Tec proposal 300 finally guiting the cement mortar 1:3 over the required area by using 7Kg.(100psi) working pressure of air compressor and cement plastering in CM 1:4 mixed with Tec proposal 300 and Tec cure WB shall be applied as curing membrane etc.,complete complying with standard specification and as directed by the departmental officer. | 58 | m2 | 1,800 ₹1.0 L | 1,790 ₹1.0 L |
| 10.00 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. | 106.4 | m2 | 300 ₹31,920 | 288 ₹30,643.20 |
Tender Value
₹11.8 L
EMD Value
₹11,750
Closing Date
27 Nov 2025, 3:00 pmClosed
Executive Engineer,PWD
Collectorate Campus Kancheepuram
Special repairs to leaky roof, Sanitary arrangements and other repairs for Sumeet office building in Government Head Quarters Hospital at Kancheepuram.
2025_PWD_626589_1
16KPM/03/2025-2026
Open Tender
Civil Works - Buildings
30 days
kancheepuram
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹11,750
Yes
22 Apr 2026
26 Nov 2025
27 Nov 2025
26 Nov 2025
27 Nov 2025
26 Nov 2025
Amount
clean removal of cement plaster from walls
Dismantling, clearing away and carefully stacking materials useful for re-use for Pressed tiles & weathering course.
Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of plain cement concrete.
Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers. - Mixing by manual means
Easing the existing over hanging doors and windows including nerewing frame its position and refixing the same after attending petty repair works including for wrough and putup in position fixing necessary furniture excluding cost of aurniture etc., complete complying with standard specification as directed by the departmental officers at site of work.
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Finishing the top of roof with one course of machine pressed tiles of following size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.
Paving the Floor with Matt finish Vitrified Tiles of size 600 x 600 x 8mm in all floors over a base layer of cement mortar 1:3 (One Cement and Three M-sand) 20mm thick and pointing with the same coloured cement neatly and fixed in position so as to make it perfectly smooth and shining to the alignment etc., complete complying with standard specification and as direted by the departmental officers. (The sample of colour and shade of the ceramic tiles should be got approved by Executive Engineer before use on works)
Chipping and removing the existing delaminated portion of the concrete surface such as beams columns, ceiling etc.,to the required depth and exposting the rods and dismantled area shall be thoroughly cleaned using sand plaster and wash the surface and steel rebars to remove ball loose particles and additional reinforcement be provided if required and bnoth the existing and new reinforcemnt rods shall be provided with two coats of TEC BEAT ZR Exit Zinc Rich reinforcement Coating system and Mixing and applying mineral based cementations bonding coat Tec bond SBR by brush to the revetted treatment surface and applying coarse repair mortar (Cement mortar mixed with chips) Mixed with the Tec proposal 300 finally guiting the cement mortar 1:3 over the required area by using 7Kg.(100psi) working pressure of air compressor and cement plastering in CM 1:4 mixed with Tec proposal 300 and Tec cure WB shall be applied as curing membrane etc.,complete complying with standard specification and as directed by the departmental officer.
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers.
Flooring with ceramic tiles of following size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing with printed design colour glazed tiles of size 300 x 450 x 8mmbest approved quality, white / colour glazed tiles conforming to IS 15622 of in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap / Swan neck tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
Supply & fixing of WPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/- 1mm) & minimum Bulk Density of 550 KG/Cub.Mt. & shore hardness of 55. The door shall be a plain matt board as decided by the Engineer in-Charge of the department. The WPC door shall be fixed onto the Aluminium “G” type channel with Wheel and the door shall have 2 Hooks in SS, 2 Handles 4” in SS (Sliding door) etc., complete and as directed by the departmental officers.
Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers.
110mm dia
Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - Internal water supply above ground level.
32mm dia
25mm dia
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
110mm dia
75mm dia
Supplying , fixing of cylindrical vertical notational polythene water storage tank of 500 litres capacity confirming to IS 12701/96. the tank is meant for outer (or) indoor, use complete with removable hinged top locking arrangements and to make provision to fix with simply pipe lines necessary manhole with cover and including all PVC specials, plugs, screws, nails to fix the tank etc., (The water tank should be got approved by the Executive Engineer before use on work .
Supplying , fixing of Water Tank Auto Cut Off three phase or single phase. This device is suitable for making motor of when the tank is full or sump water level is full Can be used in borewell motor for capacitor start motor single phase it works as a semi automatic water level controller for which ones person has to be make it on then automatically of depending on sump or head tank full status.
Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of Clay burnt Bricks of size 9” x 43/8” x 23/4” with Class designation of 7.5 and Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification.
Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting Old wood work with Two coat of synthetic enamel ready mixed paint of approved quality and colour in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
PR & CO (BID ID -1521866)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.11 MB
Tender Documents
Tender Documents • 0.31 MB
BOQ
BOQ • 0.36 MB
Tender Documents
Tender Documents • 0.22 MB
Download all tender documents and submit your bid