Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC 2 MIRZA MAHEDI LANE 25 RAFI AHMED KIDWAI ROAD KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹13.0 L+₹2,240 (0.17%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹13.0 L+₹4,500 (0.35%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest | |
| 4 | Rejected-Technical 161 SWAMIJI SARANI SOUTH DUMDUM SREEBHUMI KOLKATA 700048 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700048 | - | Rejected-Technical Non submission of valid License for safety engineering from competent authority | |
| 5 | Rejected-Technical | - | Rejected-Technical Non submission of valid License for safety engineering from competent authority |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
26 Dec 2024, 2:00 pmClosed
Executive Engineer, KSHD, PWD
KIT Building, 2nd Floor, P-16, India Exchange Place Extension, Kolkata-700073
Conducting of Fire Mock Drill and Supplying and Installation of Portable type Fire Extinguisher including refilling of existing fire extinguishers and Compressed Air Foam System Watermist FE 50 Liter Trolley Mounted for newly constructed bldg_KPH
2024_WBPWD_779686_1
WBPWD/KSHD/EE/NIQ-19 OF 2024-2025
Open Tender
CIVIL WORKS
Item Rate
365 days
Kolkata Police Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹26,000
Yes
13 Mar 2025
6 Dec 2024
28 Dec 2024
11 Dec 2024
26 Dec 2024
11 Dec 2024
Amount
Conducting Mock Drill for Fire Fighting by Skilled Personnel by using existing Portable Fire Extinguishers and a trianing should be given for Evacuation process during Fire hazard in every 15 days and report of the same has to be submitted to PWD for record.
Supplying, fixing and Testing of ABC dry powder MAP 50% (Stored Pressure type) Fire Extinguishers, capacity 6 kg ISI Mark consisting of welded MS cylinder (cylinder made out of 1.5 mm thick MS Sheet (Bursting Pressure 55 Bar Hydro Pressure Testing pressure 35 Bar and Working Pressure 15 bar) squeeze grip discharge value having mounting thread M-30 fitted with indicating gauge, internal discharge tube, discharge nozzle and hose duly discharging ISI marked mono ammonium phosphate based ABC Powder (Dry Powder as per IS:4308:2019) and pressurized with nitrogen gas, suitable for operating between -30°C to +60°C, fire rating - 4A 89B. The Colour of extinguisher should be PO Red confirming to shade 538 of IS 5. The Complete Extinguisher should Confirm to IS: 15683 :2018. A label should be pasted on the body of the extinguisher showing: 1. Supplied by: PWD 2. Date of manufacture: 3. Date of expiry / date of next filling: 4. Brand Name: (Minimax/Ceasefire/Safex/Fire Shield.)
Providing & fixing 4.5 kg CO2 type Fire Extinguisher made out of Seamless Pipe Confirming to IS: 7285 and Wheel Type Valve Confirming to IS: 3224, including Wire Braided Hose of 1 Mtr. having working pressure of 180 Bar and Horn made of Polythene Fibre Glass along with powder coated wall bracket suitable for operating between -30°C to +60°C, fire rating -34 B. The Colour of extinguisher should be PO Red confirming to shade 538 of IS 5. The Complete Extinguisher should Confirm to IS: 15683 :2018. A label should be pasted on the body of the extinguisher showing: 1. Supplied by: PWD 2. Date of manufacture: 3. Date of expiry / date of next filling: 4. Brand Name: (Minimax/Ceasefire/Safex/Fire Shield.)
Refilling of Fire Extinguisher ABC Type (6 Kg.) in corformity with the IS-2190:2010 (including Amendment no.1-2014 & Amendment no.2-2017) and IS-15683-2018 code of practice i.e. It is mandatory to recharge the extinguisher by manufacturer or authorized agent of manufacture of the existing fire extinguishers brand. Note that the certificates for satisfactory refilling have to be furnished from the manufacturer or its authorized agent at the time of supplying of the refilled fire extinguishers. All others statuary markings/levelling have to be done as per the IS-2190:2010 code of practice. Brand of Fire Extinguisher to be refilled : Fire Shield = 80 Nos.
Refilling of Fire Extinguisher CO2 Type (4.5 Kg.) in corformity with the IS-2190:2010 (including Amendment no.1-2014 & Amendment no.2-2017) and IS-15683-2018 code of practice i.e. It is mandatory to recharge the extinguisher by manufacturer or authorized agent of manufacture of the existing fire extinguishers brand. Note that the certificates for satisfactory refilling have to be furnished from the manufacturer or its authorized agent at the time of supplying of the refilled fire extinguishers. All others statuary markings/levelling have to be done as per the IS-2190:2010 code of practice. Brand of Fire Extinguisher to be refilled : Fire Shield = 10 Nos.
Supplying, Fitting & fixing of CAFS (Compressed Air Foam System) watemistfrextlngulsher 50 litre trolley mounted low pressure design 55a, lvb. 1000v- Trolley mounted water mist & compressed Air Foam (CAF System - 50Lirs-Technology. (As per DIN EN 1888 1:2007-10standards) Water Container Capacity 50 liters. Water Cylinder working pressure - 05 to 12 bars, Water cylinder construction - Non Corosive stainless steel SS 316. Water Cylinder extemal paint The cylinder should be of red colour with powder coating. The paint should confim to 1S 5:2007 shade 538, Operating working pressure - not more than 11 bers. Air bottle - certification |PESO (Petroleum and xplosive safely organization) Total Weight- Empty filled not more than 54 kg (empty). Not more than 105kh (water bottle filled& Air bottle flled capacity - 6lter/300 bar air.Alr bottle - construction- simless mild steel cylnder.Operating temparature - Minimum 5, degree to maxlmum + 60 degree celcius. Gun constructlon 1.r Device operatlon -shall be suitable for both left and right hand operations. Fire extinction |sultableClass-A, Class-B. Live electrical fires 1000 V as per EN3-7//-13083 (Tested for 36Kva). System test Electricel test Certiflcate with details of test methods Certlification from ERDA as per IS 15683. Fire Rating CertilcteCertiication from NABL accreditated Indian Lab as per EN3-7:2004+A 1:2007 fire rating certificates for Class-A. Minimum A55.Fire rating Certificate for Class B Minimum II B. Waranty- 36 months (Air Cylinder). Spare Parts Support 10 Years.
GLOBAL ELECTRIC (BID ID -5847516)
ADDYA MA SERVICES (BID ID -5847566)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .