Superintending Engineer
RSAMB Circle Ajmer
Repair and Construction of Various Buildings works under animal husbandry department pkg-01 / 2023-2024 Dist. Nagaur
2023_RSAMB_329563_7
RSAMB/Circle Ajmer/NIT-01/2023-24
Open Tender
Civil Works
Percentage
180 days
Nagaur
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
EE RSAMB Ajmer
₹1.3 L
Yes
27 Apr 2023
14 Apr 2023
26 Apr 2023
14 Apr 2023
24 Apr 2023
14 Apr 2023
Amount
(A) Construction of veterinary Medicine Storage ware House at Kuchamancity District Nagaur
NON BSR Item Electric work
Supply ,Installation,Testing & Commissioning of cold storage facility with refregeration units along with 60mm thick Poly Urethene Foam (PUF) panels inside the pre constructed stone masonary with RCC roof finished room , to operate in temperature range +4 degree celcius to +8 degree celcius suitable for storing vaccines ,with design at ambient temperature of 45 degree celcius, with dimensions of cold room as 20'* 12'*10' and as per the following specifications.The bidder has to provide desired certifications from cold room manufacturer .
PUF PANEL STRUCTURE
The panel should be fabricated from 0.50 mm thick sheet with internal finish of stain less steel SS304 and outer finish of Pre Painted GI sheet having PUF thickness of 60mm and density of PUF as 40+2 kg/cu mtr
The floor PUF panels should be designed to with stand heavy loads of Vaccines trolleys ,having 60mm PUF and 1.2mm thick Aluminium Chequred Sheet along with 12mm marine ply as required (over cement concrete floor).Adequate safety measure to incorporate for prevention of cooling loss from floor.
Supply & installation of 1 No. flush door with clear opening of 34"*78" ,view port of 300x300 mm,made of 60 mm PUF panel,internal of SS304 & outer with Pre Painted GI.There should be kick plates on both side of door along with one strip curtain. There should be high quality cam lock , hinges & handle on the door for automatic closure of the door with out any manual push.
The K value of panel be 0.14 and U Factor of 0.019 - 0.023. The panel be self extinguished fire resistance type as per ASTMD 1692.The compressive strength of sandwich type PUF panel satisfies 2.0 - 2.6 KG /Sq cm along with Dimensional stability less than 2%.The panel should be fabricated with eco friendly blow agent cyclopentane at 40+2 KG/Cub mtr
The cold room be provided with 2 number of Vapour proof LED tube lights of 4' length and 18 Watts rating with suitable switching and wiring.
REFRIGERATION UNITS
Two numbers of split type refrigeration units with hermatic Compressors are to be installed with each of 22000 BTU/Hr. heat load,out of which one act as main and other as standby unit ,to be operated on 430V, 50 HZ power supply.
The refrigeration units works automatically without any operator and should be capable of automatic change over for alternate working of both units, to maintain the temperature of +4 degree celcius to +8 degree celcius.
The refrigerant used should be CFC free gas R 134a.
There should be Evaporator unit matching with Condensor unit compete with coil section with expansion valves,distributors 300mm axial fans 3 nos,.The evaporating unit casing should be of SS 304 .The refrigerant copper piping is to be used along with suitable length drain pipes & suction line insulations.The work includes refrigerating pipings upto 20 feet.
Adequate safety measures like suitale rating MCB,overload relay,hand shut off valve,alarm, HP /LP cut out ,thermostat controlled units along with "Panic Button" for opening the cold room door from inside, in case some person is locked inside the cold room is to be provided.
One electrical control display with all control cables etc having digital temperature indicator cum controller,with USB data logger interface is to be fixed near cold room.
one electrical control unit with all control cables etc having digital temperature indicator cum controller is to be fixed near cold room.
The product should be as per CE/US-FDA CERTIFIED/IEC 60601-1-2005 & IEC 60601-1+A1:2012+A2:2020/IEC61010:2010
APPROVED MAKES or as per make approved by Engineer-in charge.
PUF PANEL : BLUE STAR / RINAC / MOTHERSON ZANNOTI / CLIMATROL CORPORATION / VOLTAS / LLYODS
EVAPORATING UNIT: BLUE STAR/ RINAC/MOTHERSON ZANNOTI/CLIMATROL CORPORATION / BOHN / STAR COOLER / LLYODS/VOLTAS
Bidder Name
Amount
RAJLAXMI CONSTRUCTION COMPANY(GSTN-08ALSPR1760M1ZB)
M/S LALCHAND JAT CONTRACTOR(GSTN-08AGXPC1997K1ZL)
M/S LALCHAND JAT CONTRACTOR
M/S LALCHAND JAT CONTRACTOR
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .