Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 CrAccepted-AOC 143 INDUSTRIAL AREA PHASE 2 PANCHKULA HARYANA | PANCHKULA | PANCHKULA | HARYANA | ₹6.8 Cr Quoted ₹7.2 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹7.5 Cr+₹34.0 L (4.75%)Rejected-AOC 322 AGGARWAL MODERN BAZAR C 33 LAWRENCE ROADS DELHI 110035 | DELHI | NORTH WEST DELHI | DELHI | 110035 | ₹7.5 Cr+₹34.0 L (4.75%) | L2 | Rejected-AOC Reject |
Tender Value
₹6.8 Cr
EMD Value
₹13.6 L
Closing Date
16 Aug 2023, 3:00 pmClosed
XEN M/GARH W.S MECH. DIVISION, NARNAUL
Executive Engineer M/Garh W.S. Mech. Divn., Narnaul, 123001
Replacement, Supply, Erection and Commissioning of Electromechanical equipments (VT pumps/ Electric Motor/ Starters/ Panels) with accessories at various pump houses NB-6, AM-1, 2, KHM-1 and RPM-1, NLD-1 to 8 and SM-1, in W.S. Mech. Divn. Narnaul
2023_HRY_300299_4
2814-25/9-A dated 21/07/2023
Open Tender
Pumps/Motors
Works
240 days
XEN M/GARH W.S MECH. DIVISION, NARNAUL
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,000
₹13.6 L
Yes
XEN M/GARH W.S MECH. DIVISION, NARNAUL
7 Dec 2023
28 Jul 2023
17 Aug 2023
28 Jul 2023
16 Aug 2023
28 Jul 2023
10 Aug 2023
Amount
Supply Installation & commissioning of 35 Cs. existing VT axial flow pump of lift 18.50' with RPM-980, including MS Delivery pipe with all flanges,Y-body, bend, syphon breaker valve & support of bend with any other leftover item duly painted inner and outer side as per site requirement & specification approved by technical committee. Motor stool and pump coupling should be as per motors/ pump. (Annexure-A) (PH NB-6=2)
Supply Installation & commissioning of 30 Cs. existing V.T. axial flow pump having lift 27.55:’ RPM-980, including MS Delivery pipe with all flange, y-body, bend, Syphon breaker valve & support of bend with any left over items duly painted inner & outer site as per site requirement & specification approved by technical committee (Annexure-A) at pump house NLD-1. (PH NLD-1=1)
Supply Installation & commissioning of 20 Cs. existing V.T. axial flow pump having lift 19.68, RPM-975, including MS Delivery pipe with all flange, y-body, bend, Syphon breaker valve & support of bend with any left over items duly painted inner & outer as per site requirement & specification approved by technical committee (Annexure-A) at pump house NLD-3 & NLD-4. (PH NLD-3=1 & NLD-4=1)
Supply Installation & commissioning of 7.5 Cs. existing V.T. axial flow pump including MS Delivery pipe, bend as per site requirement & specification approved by technical committee. Motor stool and pump coupling should be as per motors/ pump. (Annexure-A). lift 17.80'. (PH RPM-1=2)
Supply Installation & commissioningof 03 Cs. existing V.T. axial flow pump including MS Delivery pipe, bend as per site requirement & specification approved by technical committee. Motor stool and pump coupling should be as per motors/ pump. (Annexure-A). lift 18.20'. (PH- AM-2=2)
Supply, Erection and commissioning of Solid shaft motor of capacity 350 HP, 735 RPM, 3 phase, 440/415 Volt suitable for 60 Cs. V.T. axial flow pump vertical flange mounted as per site and specification approved by technical committee at pump house NLD-1=1. (PH NLD-1=1)
Supply, Erection and commissioning of Solid shaft motor of capacity 225 HP, 735 RPM, 3 phase, 440/415 Volt suitable for 50 Cs. V.T. axial flow pump vertical flange mounted as per site and specification approved by technical committee at pump house NLD-2=1, NLD-3=1, NLD-4=1 & NLD-5=1. (PH NLD-2=1, NLD-3=1, NLD-4=1 & NLD-5=1)
Supply, Erection and commissioning of induction motors solid shaft of 170 HP suitable for 35 Cs. VT axial flow pumps, 128 KW, 980 RPM, 6 Pole, 415 Voltage, 3 Phase, 50 Hz bearing SKF/ FAG as per specification (Annexure-B) and site reuirement. Motor stool and pump coupling should be as per motors/ pump. (PH NB-6=7 No.)
Supply, Erection and commissioning of Solid shaft motor of capacity 170 HP , 980 RPM, 3 phase, 440/415 Volt suitable for 30 Cs. V.T. axial flow pump having lift 18.22:’ type vertical flange mounted as per specification approved by technical committee. (PH NLD-1=1)
Supply, Erection and commissioning of Solid shaft motor of capacity 100 HP, 975 RPM, 3 phase, 440/415 Volt suitable for 20 Cs. V.T. axial flow pump vertical flange mounted as per site and specification approved by technical committee at pump house NLD-3=1, NLD-4=1, NLD-5=1, NLD-6=2, NLD-7=2 & NLD-8=1. (PH NLD-3=1, NLD-4=1, NLD-5=1, NLD-6=2, NLD-7=2 & NLD-8=1 )
Supply, Erection and commissioning of Solid shaft motor of capacity 60 HP, 980 RPM, 3 phase, 440/415 Volt suitable for 10 Cs. V.T. axial flow pump vertical flange mounted as per site and specification approved by technical committee at pump house NLD-1. (PH NLD-1=1)
Supply, Erection and commissioning of Solid shaft motor of capacity 60 HP, 1452 RPM, 3 phase, 440/415 Volt suitable for 12.5 Cs. V.T. axial flow pump vertical flange mounted as per site and specification approved by technical committee at pump house NLD-2=1. (PH NLD-2=1)
Supply, Erection and commissioning of Solid shaft motor of capacity (in place of existing hollow shaft motor) 50 HP, 1450 RPM, 3 phase, 440/415 Volt, suitable for 10 Cs. V.T. axial flow pump vertical flange mounted as per site and specification approved by technical committee at pump house NLD-6=1, NLD-8=1. (PH NLD-6=1, NLD-8=1)
Supply, Erection and commissioning of Solid shaft motor of capacity (in place of existing hollow shaft motor) 50 HP, 37 KW, 980 RPM, 415V, 3 phase, 50 Hz, class IE-2 with earthing of motor as per site requirements & as per technical specification approved by I&WRD Haryana. Motor stool and pump coupling should be as per motors/ pump. (PH KHM-1=2)
Supply, Erection and commissioning of 40 HP Solid shaft motor (in place of existing hollow shaft motor) suitable for existing 5.0 Cs. VT axial flow pump, 1440 RPM, 53 AMP, 3 phase, 415 Volt with bearings of SKF/ FAG type as per specification. Motor stool and pump coupling should be as per motors/ pump. (PH NB-6=1, KHM-1= 01 No.)
Supply, Erection and commissioning of induction motors of 40 HP Solid shaft, 1440 RPM, 3 phase, 415 Volt, as per specifications (Annexure-B) and site requirements. Motor stool and pump coupling should be as per motors/ pump. (PH RPM-1=2)
Supply, Erection and Commissioning of Solid shaft motor of capacity 30 HP, 1440 RPM, 440V+-10%, 3 phase, with efficiency class IE-2 suitable for fitment with 03 Cs. VT axial/ mix flow pump type vertical flange mounted as per approved specification of the department. Motor stool and pump coupling should be as per motors/ pump. (PH AM-2=2)
Supply, Erection and Commissioning of fully automatic ATS starter suitable for 170 HP motor with suitable contactor for main transformer/ start, interliking bush bar of suitable size complete in all respect with dagree of protection IP 54 complete with small item like air cooled ATS, thimble, nut bolt, lugs etc. with the stand of MS angle (50x50x6 mm) of 1 feet height from floor level with allied accessories as per site and approved make and specificaion by irrigation and WR department Haryana. (PH NLD-1=1, PHNB-6=2 No.)
Supply, Erection and Commissioning of fully automatic ATS starter suitable for 100 HP motor with suitable contactor for main transformer/ start, interliking bush bar of suitable size complete in all respect with dagree of protection IP 54 complete with small item like air cooled ATS, thimble, nut bolt, lugs etc. with the stand of MS angle (50x50x6 mm) of 1 feet height from floor level with allied accessories as per site and approved make and specificaion by irrigation and WR department Haryana. (PH NLD-5=1, NLD-6=1 & NLD-7=1)
Suply, reection and commissiong of fully automatic ATS starter suitable for 60 HP motor with suitable contactor for main transformer/ start, interliking bush bar of suitable size complete in all respect with dagree of protection IP 54 complete with small item like air cooled ATS, thimble, nut bolt, lugs etc. with the stand of MS angle (50x50x6 mm) of 1 feet height from floor level with allied accessories as per site and approved make and specificaion by irrigation and WR department Haryana. (PH NLD-2=1)
Supply, Erection and Commissioning of fully automatic ATS starter suitable for 50 HP motor with suitable contactor for main transformer/ start, interliking bush bar of suitable size complete in all respect with dagree of protection IP 54 complete with small item like air cooled ATS, thimble, nut bolt, lugs etc. with the stand of MS angle (50x50x6 mm) of 1 feet height from floor level with allied accessories as per site and approved make and specificaion by irrigation and WR department Haryana. (PH NLD-6=2, NLD-7= 2 & NLD-8=3)
Supply, Erection and Commissioning of fully automatic ATS starter suitable for 40 HP motor with suitable contactor for main transformer/ start, interliking bush bar of suitable size complete in all respect with dagree of protection IP 54 complete with small item like air cooled ATS, thimble, nut bolt, lugs etc. with the stand of MS angle (50x50x6 mm) of 1 feet height from floor level with allied accessories as per site and approved make and specificaion by irrigation and WR department Haryana. (PH ND-6=1,KHM-1=2No.)
Supply, Erection and Commissioning of fully automatic ATS starter suitable for 35 HP motor with suitable contactor for main transformer/ start, interliking bush bar of suitable size complete in all respect with dagree of protection IP 54 complete with small item like air cooled ATS, thimble, nut bolt, lugs etc. with the stand of MS angle (50x50x6 mm) of 1 feet height from floor level with allied accessories as per site and approved make and specificaion by irrigation and WR department Haryana. (PH SM-1=1)
Providing and commissioning of LTDB of Capacity 1600 Amps including all accessories as MCCB 1600 Amps -01 Nos. incomer, MCCB 630 amps- 02 Nos. & MCCB 400 Amp.-02 Nos. outgoing, indicators , relays, meters, push buttons,bus bars etc complete suitable for operation of 02 Nos. Motors of capacity 230 HP & 02 Nos. 100 HP with the stand of MS angle (50x50x6 mm) of 1 feet height from floor level with allied accessories as per site at pump house NLD-5 as per specification approved by Tech committee including power capacitor bank of pump house NLD-5,6,7,8 as per site requirement (Annexure-C). (PH NLD-5=1)
Replacement with Suplly, Erection & Commissioning of Auto transformer for 350 HP in existing Starter Panel (ATS Type) air cooled/ dry type with different taps provided to start the motor at, say, 50% 65% or 80% of line voltage of 415 Volt as per site requirement (Annexure-C). (PH NLD-1=2)
Replacement with Suplly, Erection & Commissioning of Auto transformer for 225 HP in extsting Starter Panel (ATS Type) air cooled/ dry type with different taps provided to start the motor at, say, 50% 65% or 80% of line voltage of 415 Volt as per site requirement (Annexure-C). (PH NLD-3=1 & NLD-4=1)
Replacement with Suplly, Erection & Commissioning of Auto transformer for 170 HP in existing Starter Panel (ATS Type) air cooled/ dry type with different taps provided to start the motor at, say, 50% 65% or 80% of line voltage of 415 Volt as per site requirement (Annexure-C). (PH NLD-1=1)
Replacement with Suplly, Erection & Commissioning of Auto transformer for 100 HP in existing Starter Panel (ATS Type) air cooled/dry type with different taps provided to start the motor at, say, 50% 65% or 80% of line voltage of 415 Volt as per site requirement (Annexure-C). (PH NLD-3=1 & NLD-4=1)
Replacement with Suplly, Erection & Commissioning of Auto transformer for 60 HP in existing Starter Panel (ATS Type) oil cooled/ immersed with different taps provided to start the motor at, say, 50% 65% or 80% of line voltage of 415 Volt as per site requirement (Annexure-C). (PH NLD-1=1 & NLD-2=1)
Supply, laying and installation of LT 1100 Volts Cable PVC XLPE armoured Aluminium Conductor of sizes as mentioned as per relevant IS specification & approved make as per annexure-c in technical specification of Haryana Irrigation Deptt. various sizes as below: 1. Single Core 1000 Sq. MM, AL. Conductor, Armoured cable (PH NB-6)
Supply, laying and installation of LT 1100 Volts Cable PVC XLPE armoured Aluminium Conductor of sizes as mentioned as per relevant IS specification & approved make as per annexure-c in technical specification of Haryana Irrigation Deptt. various sizes as below : 1. Single Core 630 Sq. MM (PH NLD-1,NB-6 Each=250 mtr.)
Supply, Erection & Commissioning of bowl assembly (i.e. impeller, impeeler shaft, coupler, extension pieces, casing with liner, diffuser & bellmouth etc) suitable for existing 35 Cs. pump make: Sintech. Y-body type VT axial/ mixed flow pump having lift approx 18.50', 980 RPM including any left over item as per site requirement (PH NB-6) for existing 35 Cs., all bolts. Specification as approved by technical committee. (Annexure-A) (Pump House NB-6=2 No.)
Providing and fixing of set of pair M.S. Cross Girder (ISMB) & M.S flat of suitable section for foundation of size=340x140mm for 10 Cs., 12.5 Cs., & 450x150mm for 20 Cs. VT Pump with approx 3400mm length each, all works as welding, painting, pcc block, A.I. Brackets, M.S Plate etc complete as per site including dismentaling/ taking down of old M.S Cross Girder structure as per site. (Pump House NLD-2=1, NLD-5=2, NLD-6=2, NLD-7=5, NLD-8=5)
Providing 30 feet deep complete double side plate earthing with 2 earth pits on both sides of pump house by boring & lowering 1.5" GI pipe, filling boring with charcoal, copper strips, salt & fixing base plate, comecting this main earthing through copper strips/ wires up to motors & panel as per site requirement. (NLD-1-8,)
M/s KRP Engineering Pvt. Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .