| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹18.3 L+₹2.3 L (14.5%)Rejected-Finance VILL GAIDUA PO HARIATARA P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPORE ST WEST BENGAL PIN 721 304 | MEDINIPUR WEST | WEST BENGAL | 721304 | L2 | Rejected-Finance Highest bid value | |
| 3 | L3₹18.4 L+₹2.4 L (15.1%)Rejected-Finance 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L3 | Rejected-Finance Highest bid value |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
29 Jul 2020, 6:00 pmClosed
Sh R Durga Shyam, EE GE (AF) Kalaikunda
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIRS/MAINT OF BORE WELL, PUMP SETS, PUMP HOUSE, PANEL BOARDS, FILTER PLANT AND CONNECTED WORKS AT AF STN SALUA
2020_MES_355881_1
8567/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
AF STN SALUA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) KALAIKUNDA
₹30,000
Yes
20 Aug 2020
25 Jun 2020
30 Jul 2020
25 Jun 2020
29 Jul 2020
9 Jul 2020
Amount
Disconnecting submersible motor of any capacity from electric system and lifting the pump and motor along with column pipe supporting wire, rope etc completely and lowering the whole system and connecting the electrical cable to starter after rectification of defects incl testing all as directed by Engr-in-Charge.
M& L for dismantling submersible pump of capacities 20/25 HP part by part and segregating serviceable/unserviceable parts, replace the U/S parts painting the entire pump and refixing the plant complete as working condition at site complete all as specified and as directed by Engr - in charge. Note: (spare parts to be measured and paid separately)
All as per item No. 02 here-in-before but capacity 7.5 HP open hole submersible pump, complete all as specified and as directed by Engr - in charge.
M& L for disconnecting the 25/20 HP submersible motor 3 phase 415 volts completely and shifting to the civil workshop for removing of U/S windings, bearing etc, incl cleaning the slots, rewinding with new insulated copper wire as per existing size and submersible 6 sqmm cable 04 RM and installation, testing complete as per manufacturer's instruction with entire satisfaction of Engr-in-charge. Note: (spare parts excluding copper coil will be measured and paid separately)
All as per item No. 04 here-in-before but capacity 7.5 HP open hole submersible pump/ Non clogging sewage pump, omplete all as specified and as directed
S&F in replacement of Bowl CI for submersible pump of 5 HP to 25 HP, omplete all as specified and as directed
S&F in replacement of sleeves (S/S) for submersible pump of 5 HP to 25 HP, omplete all as specified and as directed
S&F in replacement of rubber bush for submersible pump, omplete all as specified and as directed
S&F in replacement of hexagonal nut & bolts for submersible pump, omplete all as specified and as directed
S&F in replacement of neck ring for submersible pump of 5 HP to 25 HP capacities, omplete all as specified and as directed
S&F in replacement of thrust bearing with carbon suitable for submersible pump of 5 HP to 25 HP, omplete all as specified and as directed
Disconnecting the centrifugal pump/pump motor of capacities 15 HP and segregating serviceable/unserviceable parts, replace the U/S parts painting the entire pump and rewinding with super enamelled copper wire as per existing size, varnishing, heating and painting with 2 coats of synthetic enamelled paint and reconnecting to existing panel/MCB etc complete all as specified and as directed by Engr in charge.
All as per item No. 12 here-in-before but capacity 5 to 15 HP pump, complete all as specified and as directed.
S&F in replacement of Mechanical seal, complete all as specified and as directed.
S&F in replacement of marking tape, complete all as specified and as directed.
S&F in replacement of ' O ' Ring and gasket, complete all as specified and as directed.
S&F in replacement of Radial bearing upper, complete all as specified and as directed.
S&F in replacement of radial bearing lower, complete all as specified and as directed.
S&F in replacement of pump bearing, complete all as specified and as directed.
S&F in replacement of Shaft key, complete all as specified and as directed.
M & L flushing of existing bore well of depth up to 150mtr, and with compressor air/back washing using GI pipe 20/25 mm size for a minimum period of 6 hrs or upto the time all sludge are flushed out till clear water is obtained. Conducting Yield test with ‘V’ notch of submersible pump set in the bore well complete all as per the directions of Engr-in-charge.
S & F in replacement of MS coloumn pipe with flanged ended of size 100mm dia with 01No socket and thickness 6mm and 8TPI in both ends, length of pipe 10' including dismantling the old one from borewell, complete all as specified and as directed.
All as per item No 22 above but length of pipe 5', complete all as specified and as directed.
S&F in repairs for 3 core flat 6.0 Sqmm PVC insulated and sheathed copper conductor cable, multi-stranded, 1100V grade complete for submersible pump, complete all as specified and as directed.
M&L for cleaning of OH reservoirs/Water tank of the following capacities on RCC staging by draining out water, removing all dirt, dust and mud etc by scraping down with wire brush inside wall and bottom surfaces to remove impurities and cleaning internal surfaces with bleaching powder and fresh water, including writing the capacity, date of cleaning, next due date, etc. of Capacity 100000 gallons (including 02 chambers) all as directed by the Engineer-in-charge.
All as per item No. 25 here-in-before but capacity of 50000 gallons, complete all as specified and as directed
M&L for cleaning of the following tanks after draining out water, removing all dirt, dust and mud etc by scraping down with wire brush inside wall and bottom surfaces to remove impurities and cleaning internal surfaces with bleaching powder and fresh water , including writing the capacity and date of cleaning, etc at Aerator deck to flux mixer (22000 Gallon /h) complete all as specified and as directed
All as per item No. 27 here-in-before but at Sedimentation tank (28000 Gallon /h), complete all as specified and as directed
All as per item No. 27 here-in-before but at Filter bed (28000 Gallon /H), complete all as specified and as directed
M & L for cutting of WBM/PCC path/road and passing the pipe line below road by drilling method and making the road good in position as per existing pattern complete all as specified and as directed
S&F in replacement of PVC flexible pipe of size 100mm including clamps and its nuts to be fitted in sewage pumps complete all as specified and as directed.
Supply only white Crystal Alum of good quality, complete all as specified and as directed. Aquafit or best quality
Supply only Chlorotech-Hypochlorite Calcium based galvanised disinfectant for water treatment, more stable than Chlorine Gas and Sodium Hypochlorite) in 45Kg plastic drums or any suitable containers, complete all as specified and as directed
Supply only Chlorine test kit against old u/s kit with coloured ample complete with all testing fitments and OT solution in rexine finish box, complete all as specified and as directed
Testing of drinking water sample for servicable borewell No 3,5,6,7 and after treated water of filter plant of this stn with under mention test by authorised lab ie, IIT Kharagpur or District water testing laborotory kharagpur, Inda :- CHEMICAL TEST :- (a) PH Valve,Temperature,Turbidity,Total hardess (as caco3) mg/l, Alkalinity, TDs ppt. Max,Iron mg/l ,Nitrate mg/l,Chloride mg/l,Residual chlorire mg/l, Fluoride mg/l. BACTERIALOGICAL:- (b) Coliform orgnisms, Faecal coliforms.
M & L for 5 layers of gravel (50mm to 40mm size-75mm), 40mm to 20mm size-75mm, 20mm to 15mm size 75mm, 15mm to 5mm size 75mm and 5mm to3mm size-150mm followed by two layer of quartz sand dumbed and leveled near filter plant area of effective size 0.55mm to 0.7mm of uniformity coefficient not exceeding 1.5, old removed gravels/sand to be complete all as specified and directed.
M&L for reparing/servicing of existing Rate of flow & loss of head combine set cap 50cub/ hr by replacing unserviciable parts, complete all as directed by Engr-in charge.
M&L for reparing/servicing of existing of C I control valve double beat type consists of G I control & filter float, rate setter, orifice gear assembly, weir, arm lever, operating rod,head stock, hand wheel, extension rod etc as all complete size: 100 mm, including painting by black paint, complete all as specified and as directed.
M&L for reparing/servicing of existing of engine oil of Air compressor ( air blower ) fitted with 5 HP 440 V AC 1440 rpm TEFC motor cap: 200 cfm, complete all as specified and as directed.
M&L for Glow sign board made out of Vanyle acrylic sheet cover in front side size(121x60x13cm) and GI sheet of 20 SWG back side with angle iron frame incl two nos LED tube light of 18 watt with pre wired all connection etc complete all as specified and as directed.
M&L for repairing/servicing of existing steel shutter by replacing u/s parts incl welding etc complete and replacing worn out dry grease by using new grease etc for Pump House complete all as specified and as directed.
S&F in replacement of MCCB TPN 415Volts 160A of rupturing capacity 35KA, complete all as specified and as directed.
S&F in replacement of Auto matic star delta starter 3 phase 415 volts suitable for 25 HP submersible pump, complete all as specified and as directed.
S&F in replacement of Auto matic star delta starter 3 phase 415 volts suitable for 5 HP/7.5 HP submersible pump, complete all as specified and as directed.
S& F in replacement of brass vertical check valve of size 50mm for 5 HP/7.5 HP pump, complete all as specified and as directed.
M&L for rewinding of agitator motor 1/3HP, 6 pole, 900 RPM, 230V, 1Ph, incl dismentling taking out from FRP tank and refixing to original position complete after painting complete all as specified and as directed by Engr-in-Charge
S&F CI sluice valve of size 200 mm bore, class PN -1.6, confirming to IS : 14846-2000, long body type, with brass/SS spindle, both ends flanged with holes, provision of nut, bolts, washers, rubber gasket etc. with CI wheel, fixed to CI water mains and including taking down existing unserviceable CI sluice valve complete all as specified and as directed.
All as per item No. 47 here-in-before but 150 mm bore, complete all as specified and as directed.
All as per item No. 47 here-in-before but 100 mm bore, complete all as specified and as directed.
Taking out sluice valves of size 200 mm refacing, regrinding and refixing all as required and complete all as specified and as directed.
All as per item No. 50 here-in-before but 150 mm bore, complete all as specified and as directed.
All as per item No. 50 here-in-before but Bore of pipe 100mm , complete all as specified and as directed.
Supply only rubber gasket of size not less than 5 mm thick as per sample for repacking valves/leakage gasket packings, complete all as specified and as directed.
Repair of existing valve chamber by using brick masonry with fly ash brick valve chamber of internal size 1.5 M x1.5M x1.0 M with 23 cm thick wall in CM 1:6 including excavation if required, earth work in any strata & PCC 1:4:8 foundation type D-2, 75 mm thick including 20 mm thick PCC 1:2:4 type B1 in & plastering the internal surface with 10 mm thick cement mortar 1:4 if required & replacing old 3.15 mm MS sheet chamber cover double opening arrangement center lock system with40x40x6mm angle iron frame duly painted with two coat of black bituminous paint over one coat of red oxide primer complete all as directed by Engr in Chargre.
Cleaning the vegetation incl grass, bushes, small trees & all vegetation growth complete incl digging out roots of bushes around installation /sump/OH tanks/ valve chamber incl leveling the surface by removing debris to a distance n.exc 50 mtr complete all as specified and as directed.
M&L for run lead joints in cast iron water mains, spigot and socket, pipes and fittings 200mm bore complete all as specified and as directed.
All as per item No. 56 here-in-before but 150 mm dia, complete all as specified and as directed.
All as per item No. 56 here-in-before but 100 mm dia, complete all as specified and as directed.
M & L for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. of existing tanks of size exc 250 ltr but n exc 500 ltr complete all as specified and direted. (Note : Rate for Disinfection of tanks using bleeching powder after cleaning will be included in unit rate quoted), complete all as specified and as directed.
All as per item No. 59 here-in-before but size of tank exc 500 ltr but n exc 1000 ltr, complete all as specified and as directed.
S&F in repair 15 mm size ball valve high pressure of PTMT epoxy coated aluminium rod and plastic ball screwed for iron pipe complete all as specified and directed.
S&F in repair 20 mm size ball valve high pressure of PTMT epoxy coated aluminium rod and plastic ball screwed for iron pipe complete all as specified and directed.
Excavation in trenches n.exc 1.5M wide & n.exc 1.5m in depth for laying & removing of pipe any sizes and getting out in hard/dense soil complete all as specified and as directed.
Taking out CI pipe (sewage line) 100 mm dia with spigot and socketed ends from trenches incl opening/ burning the lead joint & cleaning for relaying, complete all as specified and as directed.
Laying only CI pipe (sewage line) as obtain from above 100 mm dia spigot and socketed ends certrifugally cast, class LA tighten joint type complete all as specified and directed.
Returning filling in excavated earthwork including spreading, leveling, watering and well ramming in layers n.exc 25cm thick, complete all as specified and as directed.
Removing excavated soil to a distance n.exc 50m, and depositing where directed at a level n.exc 1.5M above the starting point, complete all as specified and as directed.
Supply and fix in repair to water level indicator made of aluminium base, marked with white Radium paint connected with steel wire rope 4mm dia to counter weight showing level of water containing in tank including 8" dia PVC float valve and greasing of revolving pully of as per site requirement and fixed to pillar of OH water tank capacity 5000Gln and 1 lakh Gln including safety arrangement for working person complete all as specified and directed by Engr-in-Charge.
S&F in replacement of 4mm dia steel wire rope for water level indicator of various overhead tanks installed in AF station salua complete all as specified and directed by Engr-in charge.
S & F in replacement of Non Return Valve 150 mm size complete all as specified and as directed.
M/s Tekcon International
SENCO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .