Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC B 5 117 KALYANI NADIA 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | L1 | Accepted-AOC WORK ORDER USSUED | |
| 2 | L2₹4.4 L+₹6,476.24 (1.50%)Rejected-Finance 71 3 VIDYASAGAR PATH MADRAL NAIHATI 743165 | NAIHATI | 24 PARAGANAS NORTH | WEST BENGAL | 743165 | L2 | Rejected-Finance Not L1 Bidder | |
| 3 | L3₹4.4 L+₹8,199.58 (1.90%)Rejected-Finance UKILPARA KRISHNAGAR DIST NADIA | KRISHNAGAR | NADIA | WEST BENGAL | L3 | Rejected-Finance Not L1 Bidder | |
| 4 | L4₹4.4 L+₹11,219.61 (2.60%)Rejected-Finance B 17 175 KALYANI NADIA | KALYANI | NADIA | WEST BENGAL | L4 | Rejected-Finance Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹9,000
Closing Date
27 Nov 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer, EMSD-I
Office of the Assistant Engineer, EMSD-I, P16 India Exchange Place (Extn.), C.I.T. Annexe Building, KOL-73
Repairing of Centrifugal pumping machinery and replacement voltage correction arrangement with allied works at P.H.No- High lift of Helencha Ground water based W/S Scheme under EMSD-I ,PHE Dte.in 24Pgs(N).
2024_PHED_769083_22
WBPHED/AE/EMSD-I/NIET-09/24-25
Open Tender
Miscellaneous Works
Item Rate
30 days
Office of the Assistant Engineer, EMSD-I
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,000
4 Feb 2025
16 Nov 2024
2 Dec 2024
16 Nov 2024
27 Nov 2024
16 Nov 2024
Amount
Making priming arrangement for 02 nos. High lift pump by supplying suitable size 500 litre pvc tank,G.I pipe,sluice valve & all other necessary materials and making gland water removal arrangement by suitable size pvc pipe , name plate to carry out the work as per direction of E.I.C
Repairing of Gland water removal `arrangement with Supply of pvc pipe & other necessary materials as per direction of E.I.c
Painting the pump -02nos and Suction line and delivery pipe line with 2 coats of anticorrosive paint after scrapping out the old paint and rust .
Dismantling the existing damaged voltage stabilizer & allied from existing position all complete & kept at site.
Supply & delivery at site of 40 KVA 3-phase oil cooled type Servo Motor operated copper would line voltage Corrector conforming to IS-9815 (Pt.1)-1994 suitable for unbalanced input and unbalanced load voltage with following specification including first filling oil as per IS-335 where applicable [Make- Eltek/Sen & Pandit/Fiji/ECS/Digitek/OPTO/Any other approve make) Input Voltage: 3 Phase Main supply may or may not be balanced with respect to phase to phase 250V- 500V and Phase to neutral 144V-289V. Output Voltage: 3 Phase balanced output phase to phase 415±1% phase to neutral 240 V±1% and as per NIT Specification.
Installation of the above Voltage Stabilizer on the floor making suitable foundation by supplying all required materials and commissioning the same as per direction of E.I.C.
Supply & delivery at site of a) 100 Amp TPN Rewire able type switch fuse. ( Make Havells/ GEC/ Standard/any other approved make)
Supply & delivery at site of 100Amps wall mounted 4-way Bus-Bar chamber having 4nos. Copper bus-bar. ( Make Havells/ L&T/ Standard/any other approved make)
Supply & delivery at site of 100 Amp. 4 pole on load change over switch. ( Make Havells/ Standard/any other approved make)
Supply & delivery at site of 50 Sq. mm. 1.1 KV grade 3 1/2 core Al. conductor armoured P.V.C. /XLPE insulated cable. NB: Cable to be supplied as per sire requirement. ( Make: GLOSTER/NICCO/Polycab / Havell’s/Mescab)
Fitting, fixing of main switch & bus-bar as in item no. 7 to 9 on flat iron frame/angle iron frame on wall by supplying all necessary fixing materials including welding all complete as per direction.
Laying of cable as in item no.10 on wall/surface including S&F of MS saddles with earthing attachment in 10 SWG GI(HOT DIP) wire making holes etc. as necessary mending good damages and paint all complete.
Finishing the end of cable by crimping method including supplying of suitable size Al. thimble, tapes, jointing materials & supplying and fixing suitable type compression gland for above cable including supply of brass gland, rubber ring etc.
Earthing with 50mm dia. G.I. pipe 3.64mm thick x 3Mtr.(10ft.) long and 1 x 4SWG G.I. wire(4Mtr. long) 13mm diametre x 80mm (3inch) long G.I. Bolts, double nuts, washer including S & F 15mm diametre G.I. pipe protection(1Mtr. Long) to be filled with bitumen partly below ground level to an average depth of 3.65Mtr.(12ft.) below the ground level and restoring the surface duly rammed.[This cost includes earth pit and its necessary lid making]
Extra for treatment of soil by salt and charcoal coke for pipe electrode.
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Brick work around the earth pits, neat cement finishing, supply & fitting fixing of MS cover plates above the earth pits all complete as per satisfaction of E.I.C.
Testing, Commissioning the whole installation upto entire satisfaction of E.I.C.
Add: GST @ 18%
Add: Cess @ 1%
M/S. G. P. ENTERPRISE (BID ID -5772927)
RAJ AND ENTERPRISE (BID ID -5782019)
STANDARD ENGINEERING (BID ID -5785910)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .