GARRISON ENGINEER
GARRISON ENGINEER JORHAT, MES, JORHAT-785005
REPAIR/MAINT OF INTERNAL ELECTRIFICATION AT LICHUBARI , MARIANI AND ROWRIAH UNDER GE JORHAT.
2022_MES_548045_1
8073/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JOR-05
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER JORHAT
₹30,000
Yes
30 Sept 2022
26 Aug 2022
27 Sept 2022
26 Aug 2022
26 Sept 2022
13 Sept 2022
27 Aug 2022 - 1 Sept 2022
Amount
NOTES :(i)The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and switch boxes etc complete and making good the disturbed surfaces complete all as specified and as directed.
Material and labour for point wiring with PVC insulated unsheated stranded copper conductor cable of size 1.5 sq mm in and including PVC cassing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan/bell controlled by one switch complete all as specified and directed .
All as per item No-03 above but for one light point control by two two way switches complete all as specified and as directed.
All as per item No-03 above but for one 5 amp socket independent complete all as specified and as directed.
All as per item No-03 above but 3 pin 5 amps socket out let point and 5 amps light point with the same board with other suitable complete all as specified and as directed.
Material and labour for point wiring with 4.0 Sq. mm (nominal area) PVC insulated and unsheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including double lock casing caping and accessories alongwith continuous earth wire 4.0 Sq mm PVC insulated and unsheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for one socket outlet6pin15/16 amps on independent board complete all as specified and directed.
Supply and fixing of switch piano flush single pole one way 5 amps complete all as specified and as directed.
Supply and fixing in repair bell push flush type 5 Amps complete all as specified and as directed.
Supply and fixing Switch piano type 5 Amp two way complete all as specified and as directed.
Supply and fixing socket outlet 3 pin 5 Amps flush type complete all as specified and as directed.
Supply and fixing switch socket outlet multipurpose 3 pin 15 Amps /5 Amps controlled by one switch.
Supply and fixing of switch socket outlet 3 pin 6 Amps 230 volts Universal type complete all as specified and as directed.
Material and labour for Electronic type fan regulator step type 120 watt, 230 volt complete all as specified and as directed. Make : Code no 14502 of Anchor or equivalent model of make list as given in PS as approved by GE.
S&F fan capacitor of 2.5 mfd. rated voltage of 440 volt, 50 Hz complete including taking down old one
Supply and fixing of ceiling rose 3 phase PVC/ polycarbonate, isolated body complete all as specified and as directed.
Supply and fixing in repair call bell, ding dong AC 230 volt single pole (ding dong type) complete all as specified and as directed.
Supply and fixing in repair of Modular bell push 6Amp, 230 volt & one modular complete all as specified.
Supply and fixing in repair of Modular switch 6 Amp single pole one way complete all as specified.
Supply and fixing in repair of Modular socket outlet combination, 6 Amp complete all as specified.
Supply and fixing in repair of Modular switch , 16 Amp,6 pin, 3 module complete all as specified.
Supply and fixing in repair of Modular socket outlet combination, 16 Amp complete all as specified.
Supply and fixing in repair of Modular Electronic type fan regulator step type 120 watt, 230 volt complete all as specified and as directed. Make : Code no 14502 of Anchor or equivalent model of make list as given in PS as approved by GE.
Supply and fixing of LED surface/ceiling mounting(suspended from ceiling) box type light fitting 20Watt with LED Lamp , drive and made of epoxy powder coated extruded aluminium channel housing with high quality polycarbonate opal diffuser cover & high power LED’s as light source with 120 Lumen per watt (Minimum) and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up three core1.00sq. mm copper conductor flexible wire/cable complete all as specified. Make : Model No CCS-100-20-65-HL2-DP-NWH of Crompton/ BCLAB 20W WH LED P of Bajaj or equivalent model of make list as given in PS as approved by GE.
Supply and fixing in repair of lamp holder insulated body with back plate for batten fittings with LED bulb, 9W with bulb base of B22 LED complete all as directed
Supply and fixing in repair of LED bulb, 9W with bulb base of B22 LED, battery charging auto cut-off after full charge with Durable Li-ion battery and colour of cool day light bulb complete all as specified.
Supply and fixing in repair of LED bulb, 9W with bulb base of B22 LED, lumens of 825lm and colour of white bulb complete all as specified.
Supply and fixing in repairs of LED Decorative wall light fixture made up of Polycarbonate and including 9 W retrofit LED lamp B22 base and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up three core1.00sq. Mm copper conductor flexible wire/cable complete all as specified. Make : Model No LHDL03160099 of Havells or equivalent model of make list as given in PS as approved by GE.
Supply and fixing in repairs of LED 15 watt recessed mounting square down lighter polycarbonate housing with superior light output and integral driver and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up three core1.00sq. Mm copper conductor flexible wire/cable complete all as specified. Make : Model No LSDEP-15-CDL.of Crompton/ BGSLO SLEEK 15 W WH SQ of Bajaj or equivalent model of make list as given in PS as approved by GE
Supply and fixing in repairs of LED 15 watt recessed mounting round down lighter polycarbonate housing with superior light output and integral driver and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up three core1.00sq. Mm copper conductor flexible wire/cable complete all as specified. Make : Model No LCDEP-15-CDL.of Crompton/ BGSLO SLEEK 15 W WH RD of Bajaj or equivalent model of make list as given in PS as approved by GE
Supply and fixing of sub main wiring with two single core 4.0sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC double lock casing caping and accessories accessories including one single core 4.0 sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed. NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length.
Supply and fixing of sub main wiring with two single core 6.0sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC conduit and accessories accessories including one single core 6.0sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed. NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length.
Supply and fixing of PVC sheathed 4 Sq mm nominal cross section 2 core, aluminium conductor served with an inner sheathing of PVC tape amoured in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular and including taking out old one complete all as specified and as directed.
Supply and fixing in repair of Sheet metal enclosure verticaly distribution board TPN 415 Volt 8 way ,double door type and provision for 4 pole MCCB complete with 200 Amps rated vertical insulated busbar and including taking out old DB complete all as specified and as directed.
Supply and fixing in repair of sheet metal enclosure for MCBs to be used singal pole & nutral double door 8 Way 200 Amps rated busbar and including fixed with 25mm x 6 mm mild steel clamp of suitable length and including taking out old DB complete all as specified and as directed.
Supply and fixing in repair of Sheet metal enclosure verticaly distribution board TPN 415 Volt 08 way ,double door type and provision for 4 pole MCCB complete with 200 Amps rated vertical insulated busbar and including taking out old DB complete all as specified and as directed.
Supply and fixing in repair of MCBs four pole 32 to 63 Amps capacity complete all as specified and as directed.
Supply and fixing in repair of MCB DP 40 to 63 amps 415 volts 10KA breaking capacity.
Supply and fixing in repair of MCB SP of rating 6 to 32 Amps 240 V complete all as specified and as directed.
Supply and fixing in repair of MCCB 100 amps, 4 pole, breaking capacity 16 KA suitable for operation of 415 volts AC 50 HZ with fixed type all as specified in SSR Part -I including making necessary electric connections complete all as specified and directed .
Supply and fixing in repair of MCCB 63 amps, 3 pole, breaking capacity 16 KA suitable for operation of 415 volts AC 50 HZ with fixed type all as specified in SSR Part -I including making necessary electric connections complete all as specified and directed .
Supply and fixing in repair of MCCB 125 amps, 4 pole, breaking capacity 16 KA suitable for operation of 415 volts AC 50 HZ with fixed type all as specified in SSR Part -I including making necessary electric connections complete all as specified and directed .
Supply and fixing in repair of MCCB 160 amps, 4 pole, breaking capacity 16 KA suitable for operation of 415 volts AC 50 HZ with Adjustable type all as specified in SSR Part -I including making necessary electric connections complete all as specified and directed .
Supply and fixing in repair of MCCB 200 amps, 4 pole, breaking capacity 16 KA suitable for operation of 415 volts AC 50 HZ with Adjustable type all as specified in SSR Part -I including making necessary electric connections complete all as specified and directed .
Earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connetced with earthing wire 4.0mm dia as earthing lead by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 15 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 5 of MES Schedule Part-I complete including testing on completion. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ₹ ___________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
M/S RK SAHA AND CO
M/S SANTOSHI TRADERS
NIHAR ENTERPRISE
THE SUPPLY AGENCY
M/S BARUA REFRIGERATION WORKS
Chief Builders &Consultants
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .