| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.5 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder | |
| 2 | L-2₹25.8 L+₹6,725.40 (0.26%)Rejected-AOC | L-2 | Rejected-AOC other than lowest bidder | |
| 3 | L-3₹25.9 L+₹20,270.40 (0.79%)Rejected-AOC | L-3 | Rejected-AOC other than lowest bidder | |
| 4 | L-4₹27.2 L+₹1.5 L (5.83%)Rejected-AOC QTR NO 7 REHARI COLONY JAMMU TAWI J K PIN 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L-4 | Rejected-AOC other than lowest bidder | |
| 5 | L-5₹27.5 L+₹1.8 L (7.04%)Rejected-AOC | L-5 | Rejected-AOC other than lowest bidder |
Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
27 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Ram G
GE Kaluchak Pin-900673 C/O 56 APO
SPECIAL REPAIRS TO BLDG NO. P-277 AND PROVN OF STEEL SINK, PLATE RACK, PATHWAY WITH EXIT GATE AND ATT TOILET AT BD BARI MIL STN UNDER GE KALUCHAK
2022_MES_556113_1
GE/KC/NIT-39/2022-23
Open Tender
Civil Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹65,000
Yes
25 Mar 2023
6 Oct 2022
3 Nov 2022
6 Oct 2022
27 Oct 2022
20 Oct 2022
6 Oct 2022 - 13 Oct 2022
Amount
Complete removal of the existing roof treatment of any description viz tarfelt or membrance surface of roof tiles/concrete padding etc including grubbing up of tree roots, removing existing water tank of any capacity, refixing at same place after making necessary arrangements, removing all the debris to a distance n exc 100m for roof treatment work, preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in roof padding and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
Supply only liquid water proofing admixture, complete all as specifed & directed.
Taking down cement plaster on brick or stone surfaces of wall/ceiling, chajjas, roof projections etc upto triple storey etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces using liquid water proofing admixture, surface finished even and smooth without using extra cement, complete all as specified & directed. Note : Liquid water proofing admixture shall be measured & paid for seperately under respective item.
15mm thick rendering in cement mortar 1:6 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
10mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling and similar items, surface finished even and smooth without using extra cement, complete all as specified & directed.
Dismantling water tanks of capacity exc 250 litres but n exc 500 litres, complete all as specified & directed.
Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top), triple layer, connecting up pipes, securing access covers etc, hoisted & fixed in position of capacity 500 ltrs, complete all as specified & directed.
20mm bore, ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210gms), complete all as specified & directed.
Taking up or down steel tubing and connections 15mm bore, complete all as specifed & directed.
Refixing old steel tubing and connections of 15mm bore in new or old position (Walls, ceiling, floors etc.) including cleaning for refixing, complete all as specified and as directed.
Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 20mm, complete all as specified & directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified & directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, complete all as specified & directed.
Brushing neat cement slurry with 3.0Kg of cement per square metre, complete all as specifed & directed.
Vitrified light shade ceremic tiles 10mm thick (Square/rectangular) polished area of each tile not exceeding 0.36Sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in cement mortar 1:4 taking down door shutter and refixing the shutter at same place after laying of tile, complete all as specified & directed.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, complete all as specified and directed.
Glazed ceramic coloured tiles of size 450mmx300mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each, complete all as specified & directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each, complete all as specified & directed.
Pressed steel frames of size 125mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate., complete all as specified & directed. Note : PCC for filling of hollow portion shall be measured and paid for separately.
Pressed steel frames of size 105mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate., complete all as specified & directed. Note : PCC for filling of hollow portion shall be measured and paid for separately.
PCC 1:3:6 nominal mix, type C-0 using 12.5mm graded crushed stone aggregate as in filling of pressed steel door frames/chowkats, complete all as specified & directed.
35mm thick factory made 2nd class hard wood (Sal/ Hollock) plain, framed, panelled shutters (two panels) with lock rail and panels of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial face veneers on both sides.The size of rail and style as per IS–1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified & directed.
35mm thick 2nd class hard wood (Sal/Hollock), glazed and skeleton shutters (factory made), open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., size of members of shutters as specified in clause 8.24 (a) of SSR Part-I, complete all as specified & directed.
Solid PVC door/cup board frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted in openings as per specification and drawing shown in SSR Part-II, complete all as specified & directed.
Factory made solid panel PVC door/cup board shutter 30mm thick (style) consisting of frame made of MS tube for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet 5mm thick to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplied & fitted in the frame at site as per specification & drawings shown in SSR Part-II, complete as specified & directed.
Factory made box type steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS sheet tube with double side shutters (Wire Gauged shutter and Glazed Shutter), side hung shutters with MS handles and MS stays dovetailed or welded including 02 nos MS Tower Bolt 150mm long for each leaf, 8 mm square guard bars at spacing as shown in drawings, MS flat iron frame work, MS hinges, tarred hold fast, PCC 1:2:4 type B1 as in bed of hold fast, 01 No. per leaf of stopper of 100mm size, one coat of red oxide zinc chrome primer etc, complete all as specified and shown as drawing No. CEPZ/CTD-31/2013 sheet 1/2, 2/2 and CEPZ/CTD-32/2013 sheet 1/2, 2/2. Note : a). Wire cloth & sheet glass shall be measured and paid seprately under respective items. b). Rate of both type of shutters and grills/guard bars is inclusive in the quoted rate.
Aluminium anodised frame (for door) of size 124.60mm x 44.45mm made out of 1.60mm thick aluminium section, powder coated (minimum thickness 50 micron), fixed to floor/wall with plugs and screws, complete all as specified & directed.
Aluminium anodised powder coated (minimum thickness 50 micron) door shutter, rails (top, middle and style ) of size 82.53 x 44.45mm and bottom rail of size 114.30 x 44.45mm made out of 1.6mm thick aluminium sheet/section including necessary jointing cleats, glazing clips, rubber packing, mortice lock having six levers, aluminium body hydraulic door closer of suitable size, handles 2 Nos in each shutter, tower bolt, hinges etc., anodised aluminium snap beading screws, complete all as specified & directed. Note : Sheet glass will be measured and paid separately under respective item.
3mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads or glazing pins in metal frame in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
5.5mm thick tinted glass as in aluminium door/ window/ ventilator with aluminium hollow beading/ glazing clip size 19mm x 17mm made out of 0.70mm thick hollow section weighing not less than 0.97 Kgs/RM including rubber gasket, complete all as specified & directed.
Box type steel ventilator with bottom hung or top hung shutters with glazing bars, including hinges, steel side arms or peg stays and locking arrangements, one shop coat of red oxide zinc crome primer complete all as specified & directed.
Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.80mm fixed with stainless steel wire staples etc, complete all as specified & directed.
4mm thick figured glass, pin headed type and glazing with oil putty or wooden beads or glazing pins in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
Aluminum (die cast) body door closer hydraulically designation No 3 Universal type suitable for door shutter of 851 to 1000mm in width and weight 61 to 80 Kg, fixed in repairs, complete all as specified & directed.
Butt hinges, medium weight, cold rolled, mild steel 100mm long, complete all as specified & directed.
Extruded aluminium alloy handle, fabricated type, anodised, 125mm long, complete all as specified & directed.
Aluminium anodised, barrel tower bolt of extruded section and fixed, 150mm long, complete all as specified & directed.
300mm ordinary rat tail rod pattern door spring including roller and roller plate of mild steel and fixed to pressed steel frame / MS frame/ wooden chowkhats including necessary welding work etc where-ever required, fixed in repairs, complete all as specified & directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) with and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed, 300mm long, complete all as specified & directed.
Angle valves, fancy type, chromium plated, cast copper alloy, 15mm bore screwed down, high pressure with capstan head, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
Bib tap, 15mm bore, fancy type, chromium plated , cast copper alloy with capstan head, screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs, complete all as specified.
PVC connections 15mm size with PTMT nuts of length 600mm, complete all as specified & directed.
Vitreous chinaware squatting pan, 'Orissa Pattern' size 580mm x 440mm with integral foot rests, white, with ‘P’ or ‘S’ trap, front or back inlet, including provision of lime concrete, making connections to trap and to flush pipe etc. and making good to floors, fixed in repairs, complete all as specified & directed.
Vitreous china, wash hand basin, flat back, white of size 580mmx450mm including brackets, brass CP waste coupling 32mm dia with long screwed shank and fly nuts, chain and plug, porcelain stopper, PVC 32mm dia waste pipe including cutting for and pinning in ends of brackets or erecting stand, fixed in repairs, complete all as specified & directed.
Viterous china urinal, half stall type, flat back large of size 635x395x420mm, white with CP flushing nozzle on top, grating and union for discharge pipe, complete including providing and fixing plugs, beding urinal against wall in cement mortar 1:2 securing urinal plugs with and including 60mm long brass screws, pointing around urinal back in cement, complete all as specified & directed.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered `Hot’ or `Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe of 15mm bore, fixed in repairs, complete all as specified & directed.
PVC valveless, syphonic action type flushing cistern, 10 litres capacity, plunger type, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long, fixed in repairs, complete all as specified & directed.
Grating doom with or without waste hole, 100mm dia of PTMT (Minimum weight 25gms), complete all as specified & directed.
Dismantling wall & ceiling board (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified & directed.
Suspended false ceiling system using 4mm thick high pressure steam cured fibre cement pre-primed textured varient board (classic), ISI marked, conforming to IS:14982-2000 over and including GI snap grid frame work for false ceiling, grid size 605 x 605 mm with GI angle of size 24x24mm, main runner ‘T’ of size 24x38mm, secondary runner ‘T’ of size 24x28mm with 6mm GI wire with butterfly clips for leveling, fastners, supports, plugs to walls/joists etc all as per manufacturer’s Instructions, including making holes, cutting chasis and making good existing walls in cement mortar 1:3 or PCC 1:2:4 type B1, complete all as specified and directed. Note : All steel members shall be hot dipped galvanised with zinc coating not less than 120 gm/sqm.
Preparation of old decorated plastered of ceiling by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of exterior weather proof paint, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying one coat of cement base paint, complete all as specified & directed.
Preparation of new plastered or concrete surfaces of walls and applying two coats of cement base paint over a coat of cement primer, complete all as specified & directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash, complete all as specified & directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying one coat of white wash, complete all as specified & directed.
Preparation of old decorated steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified & directed.
Preparation of old painted wooden or wood based surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified & directed.
Preparation of new or previously untreated wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified & directed.
Preparation of new plastered or concrete surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer over 2mm thick wall care putty, complete all as specified & directed.
Complete removal of existing treatment from old decorated plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer over 2mm thick wall care putty, complete all as specified & directed.
Demolition of cement concrete (un-reinforced) of any description in any position not otherwise specifically provided for, complete all as specified & directed.
75mm thick PCC 1:3:6, nominal mix, type C1, using 20mm graded crushed stone aggregate as in plinth protection, surface finished even and smooth without using extra cement including filling of 6mm thick joints with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 grade and three part of sand by weight, laid in a stretch not exc 3m and joint at every turning/corners complete all as specified & directed.
Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition), complete all as specified & directed.
RCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified & directed.
75mm thick PCC 1:3:6, nominal mix, type C2, using 40mm graded crushed stone aggregate as in sub base of floor, hard standing, path, pavings etc, complete all as specified & directed.
Precast designer coloured paver tiles (factory made rectified) of size 300mmx300mm x 20mm, top layer glazed made in any type of cement and pigment, in required patterns (compressive strength not less than 250 Kg per Sqcm) as approved by GE in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, complete all as specified & directed.
Stainless steel grating of 100mm size (square/round), male/female pattern with or without hole, fixed in nahani/floor traps with white/coloured cement, complete all as specified & directed.
Bib tap, 15mm bore, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, complete all as specified & directed.
Brass CP waste coupling 32mm dia with long screwed shank and fly nuts for kitchen sink (half or full threaded) with chain and plug, porcelain stopper and 32mm dia waste pipe of polyethylene, complete all as specified & directed.
Kitchen sink made of stainless steel 1mm thick for kitchen with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever cast iron bracket, connecting union to pipe etc. and overall size 495x420mm with bowl size 410x330x160mm, complete all as specified & directed.
Granite (black), 18-20mm thick as in floor, machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting, polishing & half rounding of exposed edge of stone over & including 15mm thick screed bed in cement mortar 1:4, complete all as specified & directed.
TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
Use & waste of form work to edges of concrete flats, treads, break in floors, window cills, concrete railings openings in concrete walls, floor and roof and n exc. 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10cm but n. exc. 20cm wide for rough finished surfaces of concrete, complete all as specified & directed.
Stainless steel plate rack of size 600x750x250mm made out of AISI 304 stainless steel 0.63 mm thick having partitions including brass/stainless steel screws for fixing of partitions, nuts, bolts, washers and fittings, complete all as specified & directed.
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified & directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, pipe, cable etc. n exc 10 sqm on plan in any type of soil and getting out, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
PCC 1:4:8, nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
Hard core of gauge n exc 63mm using broken stone or boulders, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified & directed.
100mm thick PCC 1:3:6, nominal mix, type C2, using 40mm graded crushed stone aggregate as in sub base of floor etc, complete all as specified & directed.
Precast designer coloured heavy duty full body paving tiles (factory made) of size 300mmx300mm x 10mm, top layer glazed made in any type of cement and pigment, in required patterns as approved by GE in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-290 grade-E-165, complete all as specified & directed.
Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed.
Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings, convering window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc., to store and rubbish not exc. 50m, complete all as specified & directed.
Forming jambs, etc. and making good to openings in cement mortar 1:4 (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified & directed.
Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc alo splays between floors and beams for rough finished surfaces of concrete, complete all as specified & directed.
TMT bars 5mm dia & over upto & including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
75mm thick PCC 1:4:8, nominal mix, type D2, using 40mm graded crushed stone aggregate as in sub base of floor etc, complete all as specified & directed.
18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting, polishing & half rounding of exposed edge of stone over & including 15mm thick screed bed in cement mortar 1:4, complete all as specified & directed.
Aluminium anodised, barrel tower bolt of extruded section and fixed, 125mm long, complete all as specified & directed.
Galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Stop valves, cast copper alloy, 20mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specifed & directed.
PVC (SWR) pipes, 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified & directed.
PVC (SWR) pipes, 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified & directed.
110mm bore PVC (SWR) bends any radius with oval access door, complete all as specified & directed.
75mm bore PVC (SWR) bends any radius with oval access door, complete all as specified & directed.
PVC (SWR) junction single (Single T) equal or unequal, 110mm bore with oval access door, complete all as specified & directed.
PVC (SWR) floor trap, plain with grating including jointing to waste pipe with solvent cement, dia of outlet 75mm, complete all as specified & directed.
PVC (SWR) vent cowl of size 110mm bore, complete all as specified & directed.
Vitreous china wash down water closet (Pedestal pattern), white with ‘P’ or ‘S’ trap, fixed with screws of suitable size including making connections to trap and to flush pipe, fixing flushing cistern etc. and making good to floors, complete all as specified & directed.
Plastic water closet seat, white, closed pattern with flat bottom including mild steel chromium plated or aluminium hinging device & chromium plated jet nozzle with 1500mm long PVC pipe, complete all as specified & directed.
Vitreous china coloured oval type wash hand basin of size 520x400mm with 32mm dia waste pipe, brass CP waste coupling 32mm dia with long screwed shank and fly nuts, chain and plug, porcelain stopper, fixed in black granite stone including cutting of size in granite, moulding of edges, complete all as specified & directed.
Stop valves, 15mm bore, fancy type, chromium plated with long shank and cup (concealed type), cast copper alloy with capstan head, screwed down, high pressure, both ends screwed for iron pipe or for union etc., complete all as specifed & directed.
PVC connections 15mm size with PTMT nuts of length 450mm, complete all as specified & directed.
Towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and and wooden/plastic cleats (minimum weight 170 gms) fixed on walls, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surfaces of ceiling by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of white wash, complete all as specified & directed.
Concrete bed to 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:3:6 (Nominal mix) type C-2 using 40mm graded stone aggregate and tested, complete all as specified & directed.
Salt-glazed stoneware drain pipe, grade ‘A’ internal dia of pipe 150mm, laid in trenches and jointed, complete all as specified & directed.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
Precast reinforced cement concrete 1:2:4 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), and similar articals with plain faces, set in cement mortar 1:4 complete all as specified & directed.
TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
Construction of Septic Tank for 10 users including excavation in any type of soil, foundation in PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) brick work in cement mortar 1:4, RCC (M-25 design Mix) slab including cast iron manhole cover having 6mm plate embedded all around with angle iron frame vent shaft etc, complete all as specified and shown on CE Pathankot Zone TD Drawing No CEPZ/C-TD/013/13 Sheet 1 to 5.
Construction of soakage well 1.20m internal dia and 2.40m depth including excavation in any type of soil, PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in footing brick honey comb/ solid brick masonry in cement 1:4, RCC (M-25 design mix) cover slab filled with brick bats including intercepting chamber screen chamber and disposal of soil, complete all as specified and shown on CE Pathankot Zone TD Drawing No CEPZ/C-TD/013/13 Sheet 1 to 5. Note : 1. During excavation if unexpected water is encountered, the same shall be bailed out / de-watered by the contractor mechanically or manually without any extra cost. 2. The excavated surplus soil shall be removed to a distance exceeding 500mtr and not exceeding 1500mtr and deposited where directed by the Engineer-in-Charge.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan/bell point controlled by one way switch using proper colour coding, complete all as specified & directed.
All as per Srl item No. 125 above but for one 3/5 pin 5 Amps socket outlet on independent board.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 2.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 2.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 15 Amps independent using proper colour coding, complete all as specified & directed.
Switch piano flush type 5 Amps 240 volt, single pole one way, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5 Amp, flush type universal, 240 volt, complete all as specified & directed.
Switch socket combination, two in one, 6 pin type, 5 & 15 Amp, 240 Volt, flush type universal, complete all as specified & directed.
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, 240 Volt, complete all as specified & directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified & directed.
LED lamp 6500K, 900lm in white colour of 12 watt, base cap B-22 with poly carbonate diffuser and aluminium heat sink, complete all as specified & directed.
Tube light fitting integrated type suitable for LED 20W (4 feet) indoor, decorative aluminium extruded T5 LED batten complete with housing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified & directed.
Metallic exhaust fan, 300mm (12") sweep, single phase, 230 volts, 50 Hz AC, 1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings, complete with louvers and shutters, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable including cutting holes in existing brick walls for making opening for fixing of exhaust fan of 300mm sweep including grounting bolts/nuts and making good disturbed surface of walls using cement sand mortar 1:4, complete all as specified & directed.
Factory made epoxy powder coated distribution board, SPN, 4 ways with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
MCB, single pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
MCB, single pole & neutral, 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Supply, installation and testing of water heater storage type (Geyser), single phase 230V, 50Hz, 5 star energy saving high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 25 Litre capacity, 2000Watt rated power, incoloy 800 glass coated heating element, inner tank coating of ferro glass powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up and fixing arrangement on wall including providing hole fastners - 04 Nos, hot & cold water metallic flexible pipes 15 mm bore of adequate length as provided by OEM or required at site - 2 Nos, non return valve 01 No and including necessary plumbing work, complete with integrated shock safe plug with all protection features as per OEM design and standard, complete all as spcified & directed.
Cutting & screwing of existing water supply line of 15mm bore for alterations or additions (or lengthening screw on pipe to form connector) including testing after completion, complete all as specified & directed. (each cut measured)
Stop valves, cast copper alloy, 15mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specifed & directed.
Bib tap, 15mm bore, fancy type, chromium plated , cast copper alloy with capstan head, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Galvanised iron tube 40mm bore light grade (ISI marked) for cable protection to poles/ under floor/ under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified & directed.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
Repair to road cutting by providing hard core & PCC 1:2:4 type B2 using 40mm graded crushed stone aggregate including necessary compaction by rolling etc. to match with existing, complete all as specified and directed.
Galvanized iron water tubing, medium grade, 25mm bore, screwed & socket joints with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., laid in trenches including clamps connection, cutting, screwing, drilling etc, complete all as specified and directed. Note : (a) Excavation & earth work shall be mesaured & paid for seperately under respective items. (b) Unions of suitable size will be provided at all branches, tee joints at a maximum distance of 30M of straight pipe and its cost are deemed to be included in the quoted rates for this item.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 25mm, complete all as specified & directed.
M/s K.S. Constructions
KAMAL CONSTRUCTION
Hare krishna engineering const.
M/s Anand Prakash
M/s Des Raj and Sons
GENESIS INDIA
M/s Sunny Builders
JK BUILDERS AND DEVELOPERS
M/S Sudagar Mal
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .