| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹38.9 L+₹16,625.65 (0.43%)Rejected-Finance 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹41.4 L+₹2.6 L (6.74%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹42.9 L+₹4.1 L (10.6%)Rejected-Finance OPP AIR FORCE STATION VPO SORANA DISTT SAHARANPUR UP PIN 247 232 | SAHARANPUR | UTTAR PRADESH | 247232 | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹46.6 L+₹7.8 L (20.2%)Rejected-Finance | L5 | Rejected-Finance Being 5th lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
3 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
REPAIR/REPLACEMENT OF PERIMETER, EXTERNAL LIGHT FITTINGS AND OTHER CONNECTED ITEMS WITH REPAIR / MAINT OF HANGER, WEATHER SHELTER LIGHTS AND OTHER CONNECTED ITEMS AT AF STN SARSAWA
2023_MES_616995_1
8123/SAR-51/2023-24
Open Tender
Civil Works
Item Rate
333 days
GE (AF) SARSAWA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE(AF) SARSAWA
₹90,000
Yes
21 Dec 2023
4 Sept 2023
10 Oct 2023
4 Sept 2023
3 Oct 2023
19 Sept 2023
4 Sept 2023 - 19 Sept 2023
Amount
Repair replacement and maintenance of street light/security lights/flood lights installed at various locations of domestic/Technical area by tightning of loose wire connection / removal of carbon and dust deposit in electric contact point, removing the lights from pole/bldg or any other place where ever is installed, throughly checking, cleaning of the glass/ covers and make them serviceable by removing/repair/replacement of unsv parts and refixing the same at original place complete all as specified and directed. Note :- (i) Replacement of the parts shall be measured and paid seperately. (ii) Contractor will provide 20 mtr height ladder/hydra to make LED light servicable.
Supply & fixing of LED aviation light at any location yellow painted die cast aluminium alloy housing with five parellel circuits max 12 watt consumption with all accessories with and including one LED lamp 12 watt after taking out light fittings as existing at site complete all as specified and directed.
Supply only LED driver suitable for LED street light fittings 45 to 60W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply only LED driver suitable for LED street light fittings 70 to 90W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply only LED driver suitable for LED Flood light fittings 150W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply only LED driver suitable for LED Flood light fittings 200W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
S&F 60 watt LED security light fitting with LM80 certified high power LED and lens suitable for secondary integrated IP for better light distribuition, front cover of polycarbonate lens with silicon gasket duly enclosed in powder coated pressure die cast aluminium housing IP66, lumen efficiency not less than 100 lumen/watt, operating temp -10 degree to 50 degree celcius , THD less than 10 % , input voltage range 140-270 volts and PF more than 0.95, sealed potted driver and having protection against open and short circuit, reverse polarity, surge protection 5KV inbuilt and 10KV SPD external complete including taking down unserviceable existing light fitting complete all as specified & directed by Engr-in-Charge
S&F 45 watt LED security light fitting with LM80 certified high power LED and lens suitable for secondary integrated IP for better light distribuition, front cover of polycarbonate lens with silicon gasket duly enclosed in powder coated pressure die cast aluminium housing IP66, lumen efficiency not less than 100 lumen/watt, operating temp -10 degree to 50 degree celcius , THD less than 10 % , input voltage range 140-270 volts and PF more than 0.95, sealed potted driver and having protection against open and short circuit, reverse polarity, surge protection 5KV inbuilt and 10KV SPD external complete including taking down unserviceable existing light fitting complete all as specified & directed by Engr-in-Charge
S&F 100 watt LED security light fitting with LM80 certified high power LED and lens suitable for secondary integrated IP for better light distribuition, front cover of polycarbonate lens with silicon gasket duly enclosed in powder coated pressure die cast aluminium housing IP66, lumen efficiency not less than 100 lumen/watt, operating temp -10 degree to 50 degree celcius , THD less than 10 % , input voltage range 140-270 volts and PF more than 0.95, sealed potted driver and having protection against open and short circuit, reverse polarity, surge protection 5KV inbuilt and 10KV SPD external complete including taking down unserviceable existing light fitting complete all as specified & directed by Engr-in-Charge
Supply and fixing 120 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection, input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, , having name of manufacturer and logo embossed on housing of each light fitting, including taking down existing light fittings all as specified and directed.
Supply and fixing 150 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy, cast aluminium alloy housing IP 66 protection, input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, having name of manufacturer and logo embossed on housing of each light fitting, including taking down existing light fittings all as specified and directed.
Supply and fixing 200 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection, input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, including taking down existing light fittings all as specified and directed.
Supply and fixing 250 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection, input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting,all as specified and directed.
S & F in replacement of timer switch for security lights duly enclosed in suitable weather proof enclosure with locking arrangement. Fixed to wall/pole by means of clamp, nut, bolt and washers etc incl for comprising the following items :- (a) MCCB 63 A 16 KA 4 pole - 01 No Make :L&T/Scheider/legrand (b) MCB SPN 5 - 30 Amp - 01 No . Make : L&T/Scheider/legrand (c) Power contactor ML-3, 3 pole- 01 No . Make : L&T/Scheider/legrand (d) Timer switch analog dial type -01 No. Make : L&T/Legrand (e) By pass arrangement for testing/repairing the lights
S&F in replacement multi stranded copper cable PVC insulated sheathed 1100 volts grade of size 1.5 sqmm 3 core, drawing through tubular pole and GI brackets etc upto LED light and making connections and testing for functioning of light fittings complete all as specified and as directed.
S&F in replacement Non metallic Junction box made out of Thermoplastic size not less than 28 cm x17cmx10cm hinged with lockable arrangement including aluminium bus bar TPN capacity 200 Amp with one No MCB 6 Amp SP with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole/grouting in PCC muff complete all as specified and directed.
S&F in replacement Non metallic Junction box made out of thermoplastic size not less than 18 cm x10cmx8cm hinged with lockable arrangement including aluminium bus bar SPN capacity 100Amp with one No MCB 6 Amp SP with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole/grouting in PCC muff complete all as specified and directed.
Supply & fix Decorative LED Post Top Lantern light fitting with max. system wattage 40 watt and system lumen output not less than 100 lumen per watt, total system lumens not less than 3600 lumens, PF not less than 0.95, THD less than 10%, CRI not less than 70, CCT 5700 TO 6500k, input voltage range 140V to 270V AC 50 Hz, 50000 burning hours,IP 65 class 1 protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect, uniform, glare free light distribution all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of 40 watt solar street light fitting complete with GI pipe med grade 50 mm bore 20 feet long grouted in PCC , with not less than 125 lumen / watt delivered lumen efficacy , total system lumens not less than 5000 lumen,solar PV module should be 12V 60W-Mono-crystalline & solar charge controller should be MPPT & its capacity not less than 12V,6A with battery (LiFeP04) with BMS 12.8V 24 Ah & its back up should be 2 days with dimming & its life span must be more than 50000 hours all as specified and directed.
Repair/rewinding of high mast motor 0.75HP by dismantling of mast assembly from pole with manually & checking of all parts & control wiring from control gear box to fitting at site. Lifting of mast assembly with help of motor after proper rewinding/repair/greasing of motor complete all as specified and directed.
S&F LED driver suitable for 10 watt led garden light including taking out old driver with LED complete with all as specified and directed. Driver should be same make as installed as before in Led light fitting.
Supply and fixing in replacement LED strip light weatherproof type for outdoor application of colour as directed by Engr-in-charge.
S&F in replacement of sub main wiring with single core PVC insulated and unsheathed 1100 volt grade (FRLS) electric cable with multi stranded copper conductor of size 2.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia concealed type including all conduct fittings and accessories such as tees junction boxes, bends and including drawing continuous earth wire PVC insulated unsheathed 1100v grade cable with stranded copper conductor of size 2.5 Sqmm and connected to earth dolly complete all as specified and directed by Engrs-in-Charge.
Supply and fixing in replacement of spare contacter coil of power contactor type ML-3 , 3 pole suitable for street light timer panel complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of spare contact kit of power contactor type ML-3 , 3 pole suitable for street light timer panel complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of power contactor type ML-3 , 3 pole suitable for street light timer panel complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement Timer clock analog dial type suitable for street light timer panel complete all as specified and directed by Engr-in-charge.
Supply and fixing thermal magnetic release 63 Amps 4 Pole 415V MCCB Breaking capacity Icu 16KA all as specified and directed.
Supply and fixing in replacement of Indicator lamp suitable for LT panel as standard colour (R,Y,B) including taking out old unsv complete all as specified and directed by Engr-in-charge.
Cutting the worn out/unserviceable lugs from the cables upto 50 Sqmm size with and including supplying and fixing lugs after cutting the worn out /faulty cable end from HT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning filling etc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all as specified and as directed.
M&L for Cleaning & preparation of surface of the LT steel tubular poles with emmery paper filling of uneven surface with suitable filler and painting with two coat of aluminium paint including cross arms, brackets, hooks, junction box, stay clamps over a coat of red oxide primer and making blue & white strip 30cm wide strip (5 Nos) upto 1.5 m from PCC coping, above 1.5 m height in and including marking and numbering of poles complete all as specified and directed by Engineer- in-charge.
M&L for PCC 1 : 4 : 8 type D2 Using 40 mm graded stone aggregate for foundation of poles complete all as specified and directed .
M&L for PCC 1 : 3 : 6 type C2 Using 40 mm graded stone aggregate for foundation of stay/panal complete all as specified and directed .
Dismantling of old vintage steel tubular poles alongwith insulators and disposing off from site complete all as specified and directed.
Supply, transporting to site, errecting and fixing in position 9 metre long, Steel tubular swaged poles complete with cast iron/mild steel base plate, finial taper plug, bolts, nuts washers & screws as specified, type 410, SP-31 IS 2713 marked, drilling of necessary hole including painting to steel tubular poles, with two coats of aluminium paint over a coat of red oxide primer on exposed surface of poles and with black bituminous paint on portion of pole embedded in concrete and painting 3 Nos bands/strips with fluorescent PO red synthetic enamel paint 30 cms wide strip at 30 cms spacing from plinth block and numbering of poles complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, exc 1.5 m deep and not exc 3 mtr and getting out in soft/loose soil complete all as specified and directed
Supplying, laying, jointing , testing and commisssioning in replacement underground XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cable (heavy duty) 1100 volt grade with size of 10 Sqmm 2 core confirming to IS: 7098 part-I ammended upto date, laid in trenches, along pole/wall/across road etc as per site condition .Note:- Exacavation/Earth work , brick & sand protection shall be measured and paid saperately.
All as per item No 38 above but size 10 sq mm 4 core
All as per item No 38 above but size 16 sq mm 4 core
All as per item No 38 above but size 25 sq mm 4 core
Supply and laying double walled corrugated HDPE duct pipe of 40 mm outer dia confirming to IS 14930 Pt II with antirodent and non flame propergating properties of approved colour complete with fitting for cable protection complete all as specified and as directed.
S&F in replacement cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending (cold or hot) drilling holes for bolts bent to any shape or size as indicated or directed inclusive of one primer coat of red oxide zinc chromate one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
S&F street light bracket made out of light grade GI pipe 40 mm normal bore of 1.2 mtr long tilted 30 degree angle on 0.4 metre length along with flat iron clamp of 40 x 4 mm size 750 mm long duly drilled made to shape the bracket with nut, bolt and washer including applying two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of LED Food light of capacity 50 Watt, IP 65, rated voltage 220V-240V AC/ 50 Hz of desired colour as directed, including taking down old unsv light complete all as specified and directed by Engr-in-charge.
S&F 10 watt led bollard light system lumen output not less than 80 lumen per watt, total system lumens not less than 3200 lumens, PF not less than 0.90, THD less than 10%, CRI not less than 70, CCT 5700 TO 6500k, ,input voltage range 140V to 270V AC 50 Hz, 50000 burning hours,IP 65 class 1 protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect, uniform, glare free light distribution including taking out old any type light complete with all as specified and directed.
Supply and fixing of Automatic street light switch using infrared sensor based nature switch for automatic switching of street light, nature switch operating should be based on nature switch lux level required luminaire level for switching on is < 30 and for switching off >10 Lux . The sensor alongwith suitable power contactors , incoming outgoing MCBs should be enclosed in a pole /wall mountable enclosure made rust proof , electric shock proof , termite proof, and FR grade SMC junction box conforming to IP 54. Timer should also have provision of auto/ manual toggle switch. The circuit should be suitable to the three phase load of 6 KW with contactors (3 Nos) & incoming- outgoing MCBs (3 Nos each) rating of 20-25 Amps & circuit wiring of minimum 10 Sqmm complete all as specified and direcetd by Engr-in-charge.
Supply and fixing in replacement flameproof LED light fitting 60W CMRI certified recommended for Gas/Vapour Group IIAand IIB and zone 1&2 IP65 protection made aluminium alloy LM6 complete with all accessories prewired and including connecting up with three core flexible copper cable of suitable size. Note:-(a) all fitting shall be ISI marked and have approval of CMRI dhanbad. (b) Original test certificate of manufacturer shall be produced by contractor (c) Lumen efficiency of fitting shall be minimum 100 lumen/watt. (d) PF shall be minimum 0.9 (e ) THD shall be below 10%. Make : Sudhir/Baliga/Crompton /Shyam
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V complete all as specified and as directed .
Supply and fixing in replacement 9 Watt LED spike light of different colour all as specified and directed. Make-Surya cat part no SLE SPL 9W MALLOW or equivalent IN HAVELLS/BAJAJ.
Supply and fixing in replacement 9 Watt mallow LED bush light all as specified and directed Make-Surya cat part no SLE BSL 9W MALLOW or equivalent IN HAVELLS/ BAJAJ to this..
Supply and fixing in replacement of flame proof/weather proof direct entry type rotary switch single pole on & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 10 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure all as specified and directed by Engr-in-charge. Sudhir/Baliga/Shyam.
Supply and fixing of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
Supply and fixing thermal magnetic release 100 Amps 4 Pole 415V MCCB Breaking capacity Icu 25KA all as specified and directed.
Supply and fixing in replacement of LED decorative fountain light waterproof colour as directed and as per sample size and shape complete all as specified and directed by Engr-in-charge.
S&F PVC insulated spacers, 12mm dia flexible type suitable for making / turning to any shape and size and suitable for 2 conductor runs including disconnecting, dismantling and taking down existing unserviceable spacers of any description and in any position from the LT electric overhead lines of any height complete all as specified and directed.
S&F PVC insulated spacers, 12mm dia flexible type suitable for making / turning to any shape and size and suitable for 3 conductor runs including disconnecting, dismantling and taking down existing unserviceable spacers of any description and in any position from the LT electric overhead lines of any height complete all as specified and directed.
Labour only for prunning of tree branches from the site touching/embracing LT overhead lines in order to maintain a clearence of 2 mtr of the conductors incl removing the tree branches from site complete all as directed
Supply and fixing in replacement of pin type insulator vitreous, porcelain, white, brown or green with overall dimensions 90 X140 mm and clearance dia of hole 25.5mm after taking down/out insulator as existing at site complete all as specified and as directed.
S&F Loop type insulator, vitreous porcelain, white, brown or green small size, with overall dimensions 65 x 90mm, clearance of hole 16m complete all as specified and as directed.
Supply and fixing FRLS PVC round sheated, copper conductor (flexible) industrial cable 1100 Volt conforming to IS 694 of size 4 Sqmm 10 CORE from panel to flood light fixed at 20 mtr height High mast system complete all as specified and directed by Engr-in charge..
Supply & fixing of LED driver suitable for LED High bay light fittings 150 W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply and fixing 150 watt LED High bay light with high luminous efficacy upto >=100 LPW , IP 66 protected , front toughened glass with discrete high lumen LED , cast alluminium alloy housingn, input voltage range 140-270 volts auto cut off at voltage exceeding 300 volts, autopower on after cutt off with time delay of less than 60 seconds, power factor more than 0.95,, driver electrical efficiency not less than 85% at constant current delivery, with secondary optic lense for every LED, with name of manufacturer / logo clearly embossed on housing of every fitting, , including taking down existing light fittings complete all as directed and specified.
Supply & fix in replacement of flame proof LED flood light luminaries 120 watt comprising of body made in cast alluminum alloy LM6 construction luminaries spun alluminium reflector fitted inside main body main body, heat resistant toughend glass cemented to cast aluninuuim, retainging ring fixed to main body , mounted on MS galvanised iron cradle and base plate for rotating in horizontal and vertical planes, voltage 140-270,IP 65 , main connector suitable up to 6 Sqmm incoming cable, terminal enclosure plain covers are fixed by means of socket head allen cap stainless steel screw, conforming to standard IS/IEC 60079-0-2004, IS/IEC 60079-1-2007 , earthing with internal 1 No., external 2 Nos on main Enclosure M6x 12 MS screw & plain washer all as specified and directed by Engr-in-charge. Sudhir/Baliga/Shyam.Note:- (i) Contractor will provide 20 mtr height ladder/hydra to make hanger LED light fixing at your own arrangement
S&F in replacement multi stranded copper cable PVC insulated sheathed 1100 volts grade of size 2.5 sqmm 3 core, drawing through tubular pole and GI brackets etc upto LED light and making connections and testing for functioning of light fittings complete all as specified and as directed.
M&L for PCC 1 : 2 : 4 type B1 Using 20 mm graded stone aggregate for copping of poles/stay/panal complete all as specified and directed .
Supply only 25 mt long 2.5 cm wide and at least 0.125mm wall thickness PVC tape of good quality all as specified and directed.
Excavation in trenches in any type of soil not exc 1.5 mtr wide and not exc 1.5 mtr deep for taking out/laying of U/G HT/LT cable and getting out the excavated soil including triming the sides
Returning, filling in, incl spreading leveling, watering and well raming in layers not exc 25 centimetre thick in layer in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed Engr-in-Charge.
Material and labour for Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed.
Material and labour for Sand cushioning with layer of fine sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and as directed.
Labour for angering upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified.
S&F in replacement of sheet metal enclosure single door concealed/surface mounted suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V complete all as specified and as directed .
S&F in replacement of sheet metal enclosure single door concealed/surface mounted suitable for TPN distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V complete all as specified and as directed .
S&F in replacement MCB SP 5 to 32 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
M&L for replacement of 4 pole isolator 63 Amps complete all as specified and directed by Engr-in-charge.
Supply and fixing lithium ferro phosphate battery of capacity 3.2V 6000 Mah Li Ion including taking down from solar panel light complete all as specified and directed.
OMVIN ENTERPRISES LLP
ISHWAR ELECTRICALS AND PROCESS SERVICES
SUBHASH CHAND CONTRACTOR
Sharma Electrical and Engineering Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .