| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.9 L+₹1.0 L (3.60%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹30.0 L+₹1.1 L (3.72%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹30.0 L+₹1.1 L (3.83%)Rejected-Finance H NO 2049 HANUMAN COLONY NEAR TCP 3 HISAR CANTT PIN 125006 HARYANA | HISAR | HARYANA | 125006 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹32.8 L+₹3.9 L (13.6%)Rejected-Finance H NO 39 3 CHANNI HIMMAT JAMMU 180015 J K | JAMMU | JAMMU AND KASHMIR | 180015 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹30.8 L
EMD Value
₹61,500
Closing Date
19 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Satwari
GE Satwari Jammu
PROVN OF NIGHT PICKET WITH TOILET AND BATHROOM AND ALL CONNECTED SERVICES NEAR MAIN GATE AND PROVN OF TOILET AND BATHROOM AND ALL CONNECTED SERVICES NEAR POST NO 4 AT MIL STN JAMMU UNDER GE SATWARI
2023_MES_618923_1
GEJM-56/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Satwari
D Class cat a i
9 documents required · 9 mandatory
₹500
GE Satwari
₹61,500
Yes
21 Dec 2023
21 Sept 2023
21 Oct 2023
21 Sept 2023
19 Oct 2023
6 Oct 2023
Amount
Surface dressing n exc 15cm deep and getting out in any type of soil complete all as specified.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables, pipe line, pole etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out, in any type of soil, complete all as specified and as directed by Engineer-In-Charge.
M&L Plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregate), as in subbase, mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
Material and labour for RCC Type B1 1:2:4 (20 mm aggregate)as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns complete all as directed.
Material and labour RCC Type B1 1:2:4 (20 mm aggregate) as in columns, pillars, piers, posts and struts etc complete all as specified and directed
Material and labour RCC Type B1 1:2:4 (20 mm aggregate) as in beams, cantilevers, bressummers, lintel over 1.5 m span completed all as specified ad directed.
Material and labour RCC Type B1 1:2:4 (20 mm aggregate) as in chajja completed all as specified ad directed.
Material and labour RCC (Design Mix) M-25 as in in slabs supported on walls beams and clumns in floors, roofs, landings, balcony, canopies, deck slabs and in slaves and like..
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces complete all as specified and as directed by Engineer-In-Charge.
Use and waste of formwork to sides of pillars, posts, struts, pier, column square, rectangular or polygonal rough finished surface of concrete complete all as specified and as directed by Engineer-In-Charge.
Formwork to chullah hoods, chajjas, troughs and similar items including edges etc complete all as specified and as directed
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves etc with fair finished surface of concrete complete all as specified and as directed by Engineer-In-Charge.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces complete all as specified and as directed by Engineer-In-Charge.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surfaces complete all as specified and as directed by Engineer-In-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge.
Spreading and levelling in layers n exc. 25 cm thick,watering and well ramming in layers as in floors with earth obtained from excavation complete all as specified and directed by Engineer-In-Charge.
Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
Material and labour for brick work in cement mortar 1:6 using sub-class B bricks straight or curved on plan exc 6m mean radius all as specified.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 all as specified.
M&L TMT bars 10 mm and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-In-Charge.
M&L TMT bars 5 mm and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers and builders.
M&L TMT bars 8mm dia cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality etc complete all as specified and as directed
M&L for 75mm thick PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate), as in subbase, of floor complete all as specified and as directed by Engineer-In-Charge.
M&L Plain cement concrete M-15 (1:2:4), type B-0 (using 12.5mm graded crushed stone aggregate), nominal mix, 25 mm thick, as in floors, finished even and fair complete all as specified and as directed by Engineer-In-Charge.
M&L Non - skid anti scratch, anti fungus, digital Ceramic coloured joint less tiles 8 to 10 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15 mm thick screed bed CM 1:4 complete all as specified and as directed by Engineer-In-Charge.
Material and labour for glazed ceramic tile 450mm x 300mm x 8mm thick on vertical surface as in skirting/dado etc set and jointed with neat cement slurry and pointed with white cement mixed with colour to match the tile including 10 mm thick rendering CM 1:4 complete all as specified and directed.
Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified.
Material and labour for rendering 10mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified.
Material and labour for rendering 5 mm thick on fair faces of brick work or concrete surfaces in ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified.
M&L Machine cut kota stone slab flooring 20-25 mm thick over cement screed bed laid and jointed cement screed bed laidand jointed with grey camant slurry mixed with pigment to match the shade of slab including rubbing and polishing complete for tread of staircase over and including 15mm thick screed bed in CM 1:4 all as specifid and directed
M&L Machine cut kota stone slab 15-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete for risers of staircase over and including 10mm thick fair and even plaster in CM 1:4 after roughing surfaces of old concrete/any type of plaster by picking sweeping down with water to remove dust etc.
S&F pressed steel frame of size 125x60mm for doors with double rebated including mild steel hinges medium weight 100 mm long and 25x3mm flat iron in holdfast, tie bar including necessary fixing lugs, lock, strike plate and fixing arrangement with and including back filling of chowkats in PCC 1:3:6 complete all as specified and directed.
Supply and fixing Box type Steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter ( wire and glass panes shall be measured and paid separately ) with side hung shutters with steel handle and steel peg stay dovetailed ot welded incl 2 Nos tower bolts 150mm long for each leaf and 8mm square bar grills at spacing as shown on drg welded to F I frame work , incl other fittings ,hinges ,handles tarred hold fasts PCC blocks etc. all as shown on drg No CEPZ /TD-354/09 sheet 1/3 to 3/3 complete (Grill measured separately)
Ditto all as per item No 33 but as in ventilators (n.exc 0.70 Sqm)
Supply only water proofing compound liquid.
S&F Mild steel works of flat iron, square bar, round bars etc. as in framed work such as grills, guard bars, gratings etc incl bending, cutting and welding as necessary of confirming to Gde Fe 310-0 all as specified.
M&L Vitreous China wash basin, white, flat back, size 580x450 mm excluding taps, waste, chain and plug and porcelain stopper including brackets of any size, including cutting for and pinning in ends of brackets or erecting stand including fixing and supply of waste pipe of 32mm dia, waste coupling of PTMT (half or full threaded), and PVC connection 15 mm dia 450 mm long complete all as specified and as directed by Engineer-In-Charge.
S&F Tubular towel rail, 20mm dia, D type, 60cm long between flanges, chromium plated fixed to walls with chromium plated brass screws, complete all as specified and as directed by Engineer-In-Charge.
Material and labour for Vitreous China squatting pan 'Orissa' pattern size 580x440mm white with integral foot rest with 'P' or 'S' trap (excluding flushing cistern and flush pipe) and provision of PCC bedding in 1:2:4 concrete and making good floor, all as specified.
Supply and fixing 10 litres capacity PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets including PVC flushing pipe 32mm bore as required and a pair of bracket etc complete all as specified
S&F Urinal with complete accessories Set, CP waste cuppling, waste pipe, sprader etc. Size: 375 x 390 x 590mm complete all as specified.
Supply and fixing Vitreous china urinal partition white of size 310x700mm complete, all as specified and as directed.
S&F PVC (SWR) pipes, 110 mm bore, single socketed, in any length with rubber ring joints, laid in trenches/fixed on walls complete all as specified and as directed by Engineer-In-Charge.
S&F PVC (SWR) pipes, 75 mm bore, single socketed, in any length with rubber ring joints, laid in trenches/fixed on walls complete all as specified and as directed by Engineer-In-Charge.
S&F PVC (SWR) bends of 110 mm bore, any radius, complete all as specified and as directed by Engineer-In-Charge.
S&F PVC (SWR) bends of 75 mm bore, any radius, complete all as specified and as directed by Engineer-In-Charge.
S&F PVC (SWR) reducers 110 mm bore complete all as specified.
PVC (SWR) vent cowl 75 mm bore all as specified.
S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement for bore of pipe 75 mm dia complete all as specified and as directed by Engineer-In-Charge.
S&F Rotational moulded polyethylene water storage tanks of 1000 liters capacity, triple layered white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-in-Charge.
S&F Rotational moulded polyethylene water storage tanks of 500 liters capacity,triple layered white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-in-Charge.
S&F Gun-metal, 20 mm bore, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified.
Supplying, laying, jointing & testing galvanised iron pipe 15 mm bore medium grade with screwed joint together with all fitting such as bends, elbows, tees, short pieces and union etc fixed to walls or laid in floors including all fittings complete all as specified and directed.
Supplying, laying, jointing & testing galvanised iron pipe 20 mm bore medium grade with screwed joint together with all fitting such as bends, elbows, tees, short pieces and union etc fixed to walls or laid in floors including all fittings complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth
S&F fancy type CP stop valves, concealed type,cast copper alloy,chromium plated with long shank and cup screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
S&F PVC connections 15mm size with PTMT nuts of length 600 mm, complete all as specified and as directed by Engineer-In-Charge.
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed for 15mm bore pipe,complete all as specified and as directed by Engineer-In-Charge.
M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate), 75mm thick, as in plinth protection and providing the joints throughout the thickness, filled with mastic filling comprising bitumen 85/25 grade and sand mixture 1:3 by weight, complete all as specified and as directed by Engineer-In-Charge.
M&L Mild steel flat & angle iron as in doors or gates frame including, drilling holes, welding , etc and similar work conforming to Fe-290 Gde E-165 etc complete all as specified and directed by Engineer-In-Charge.
S&F Mild steel small articles such as flat iron for hold fasts etc conforming to Fe 290 Gde-E-165, all as specified and as directed.
M& L for PCC 1:2:4 type B 1 using (20 mm graded aggregate) as in blocks for hold fasts, benching, coping apex stones, bed plates and the like including weathering slightly rounded or chamfered angles and throating all as specified and direct. Note: Form work required for these items included in the unit rate of this item.
S&F Soild PVC door frame of size 50mm x 47mm made out of 5 mm plain coloured PVC sheet, reinforced with MS square tube supplying and fixing in opening as per specification and drawing.
S & F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing, complete all as specified and as directed by Engineer-In-Charge.
M&L 35 mm thick 2nd class soft wood, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply. The size of rail and stile as per IS : 1003 (Part I), complete all as speciied.
M&L Flush shutters, 30 mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified. Note:- Sampel approved by Engr-in-Charge or GE.
S&F 35mm thick 2nd class soft wood glazed and skelton shutters open rebated and prepared to receive gauge etc without sash bar but with lock rail fitted with cut and mitered beads complete all as speciied.
S&F Butt hinges, size 100mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed by Engineer-In-Charge.
S&F Aluminium anodised, barrel tower bolts of extruded Section, size 150 mm long and fixed, complete all as specified and as directed by Engineer-In-Charge.
S&F Aluminium handles, cast type, anodised, size 150 mm, complete all as specified and as directed by Engineer-In-Charge.
S&F Aluminium alloy, anodised, sliding door bolt Size- 250 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified.
Supply and fixing mild steel helical ordinary rat tail rod pattern springs 300mm including roller and roller plate complete including fixing to pressed steel frames necessary welding work all as specified and as directed.
M&L for applying two coat of synthetic enamel paint on new wooden surfaces of any description over a coat of pink primer having width/girth exceeding 10 cm complete all as specified including preparation and necessary filling by chalk putty as and where requered to make surface even and smooth.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces including preparation of new surface over 10cm width or girth complete all as directed by Engr-in-Charge
S&F galvanized mild steel wire cloth of 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tack or galvanized wire staples complete all as directed.
M&L 4mm thick sheet glass ordinary quality and glazing with oil putty in area n.exc 0.5 sqm each pane complete all as specified.
S&F 4mm thick figured glass, pin head/frosted type and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of wall care putty 1mm thick, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of wall and applying three coats of white washing, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white washing, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of cement based paint over and including one coat of primer, complete all as specified and as directed by Engineer-In-Charge.
Preparation of concrete /plastered surface by scrubbing down with steel brushes and cleaning with water all loose dirt / dust and applying roof treatment as below:-- (i) Rendering 15mm thck in CM 1:4 mixed with integral Water proofing compound on concrete surface in roofs incl applying cement slurry @ 3 Kg per Sqm finishing even and fair without using extra cement ( WPA shall be measured separately) (ii) Applying 1st coat of bitumen primer membrane 0.4ltr/sqm by the same membrane manufacturer of density at 25 degree C’ 0.87-0.89Kg/Litre and viscosity 70-160 CPS till the surface properly impregnates and insolvent oil primer evaporates completely (iii) Applying 2nd course of a coat of blown type bitumen of grade 85/25 heated to a temperature of 180 degree centigrade and applying @ 1.2 kg/sqm completely (iv) Applying 3rd course of Polymeric Polypropylene polymer membrane “APP” (Atactic poly propylene polymer ) modified prefabricated five layer 3mm thick not less than 3.6 Kg/Sqm with 160 grams/sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 overlap in length using butane torch with 10cm over laps which shall be thermo fused by flame. (v) Applying course of two coats of aluminium paint over the APP membrane all as specified. All joints and change in direction shall be covered with cement mortar 1:3 mixed with SBR latex @ 200 ml/bag of cement and curved before laying membrane Note : Ponding shall be done over RCC slab by filling water which shall be kept for 48 hours.In case a slightest indication of seepage / leakage is noticed the same shall be rectified by grouting the affected portion at no extra cost.Thereafter ponding test shall be repeated till there is no indication of seepage /leakage before application of roof treatment. A proper record of ponding test of RCC slabs shall be maintained by Engr in Charge.The arrangement of ponding test shall be made by the contractor and shall be included in the quoted rates..
Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in any type of soil and etc complete all as specified and as directed
M&L for PCC 1:3:6 type C-2 ( 40 mm graded aggregate) as in sub base, 75 mm thickness, all as specified and directed by Engr-in-Charge
Material and labour Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade over and including 15mm thick screed bed with CM 1:6 complete all as specified and directed by Engr-in-Charge.
Material and labour for Cement concrete tiles 30cm x 30cm and 25mm thick, machine pressed set jointed and pointed in neat cement slurry with grey cement and in floors, and cut and polished, over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes, complete all as specified and as directed by Engr-in-Charge.
M&L HDPE Double wall corrugated pipe with 150mm (S4 ) with integral socket and necessary fittings, laid in trenches jointed complete all as specified and directed.
M & L for precast cement concrete 1:2:4 type B-1 (Using 20mm graded stone aggregates) as in manholes cover slabs for septic tank and including necessary form work and set in cement mortar 1:6 , complete, all as specified and shown on drawings.
M&L Septic tanks, exc in ordinary soil, foundation in PCC 1:2:4 brick work in CM 1:4 slab covers including RCC precast manhole cover having 6mm plate embadded all around / fibre reinforced cover with angle iron frame vent shaft and sludge chamber etc, complete for 10 users.
M&L soakage well exc, in any type of soil, foundation in PCC 1:3:6 wells of honey combed and solidin M-25 concrete, including intercepting chamber brick work in CM, RCC cover slab in M-25, filling with brick bats, complete of size 1.20 mtr dia x 3.0 mtr deep.
M&L soakage well exc, in any type of soil, foundation in PCC 1:3:6 wells of honey combed and solidin M-25 concrete, including intercepting chamber brick work in CM, RCC cover slab in M-25, filling with brick bats, complete of size 2.40 mtr dia x 3.0 mtr deep.
M&L PCC 1:2:4 type B2,( using 20 mm graded stone aggregate) as in surface channel and drain complete all as specified.
Extra for forming fair finished drain or channel upto 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.
M&L Rendering 05 mm thick on fair faces of brick/concrete surfaces in cement plaster 1:4, finished even and smooth without using extra cement, complete, all as specified and as directed.
M&L Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, for 150mm bore of pipe plain cement concrete 1:3:6 type C-2 (Using 40mm graded stone aggregates)including necessary form work, complete all as specified and directed.
S&F CP Bib taps, long body, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified complete all as specified.
S&F fancy type CP stop angle valves, concealed type,cast copper alloy,chromium plated with long shank and cup screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
S&F stainless steel lock grating plain/hole size 100 mm dia including embeding in tiles with white cement complete all as specified.
M & L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through heavy duty PVC concealed conduit fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly, including concealed MS box with 3 mm thick laminated sheet cover fixed with brass screws and cup washers for mounting of plate mounting for housing the switches, socket outlets, fan regulators etc, all as specified and as directed. (a) One Light / Exhaust Fan point controlled by one, one way switch 6 Amp complete
(b) One 3 pin socket outlet 6 amp independent
(c) One 3 pin socket outlet 6 amp same board
All as per srl item No 101 above but for one 3 pin socket outlet 16 Amp independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire.
Supply and fix switch piano, flush type single pole, one way 5 Amps capacity
Supply and fix socket out let 2 in 1, 5 Pin, 6A combined 2 module
Supply and fix switch piano, flush type single pole, one way 16 Amps capacity
Supply and fix socket out let 2 in 1, 5 Pin, 16A combined 2 module
Supply and fix ceiling rose surface, backelite, three terminal, 240 volts complete all as specified and directed.
Supply and fix LED light fitting 1 x 18Watt, T-8, 220V, AC decorative box type with 18 Watts tube lights , driver, holder including LED Tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all fixing arrengenment all as directed by Engr in chage. Note:- The LED batten and LED tube rod shall be of same make.
Supply and fix of lamp holder, PVC /Polycarbonate type with back plate for batten fitting .
Supply and fix LED lamp suitable for B22 holder of capacity 10 Watt.
Supply and fix energy saving new generation 10W LED IP65 bulk head luminaire with opal diffuser complete all as specified and directed.
Supply and fix Distribution Board (SPN) double door 12 Way and should be IP 43 protected with Copper Bus bar 100 Amp rated, Earth Bar ,neutral Bar Door Earthing.
Supply and fix Distribution Board (SPN) double door 4 Way and should be IP 43 protected with Copper Bus bar 100 Amp rate, Earth Bar, neutral Bar Door Earthing.
Supply and fix MCB TPN complete 63 Amp with 240 Volts, rupturing capacity 10 KA 'C' series, complete all as specified and directed.
Supply and fix MCB SPN complete 32 Amp with 240 Volts, rupturing capacity 10 KA 'C' series, complete all as specified and directed.
Supply and fix MCB Single pole 6 to 32 Amp with 240 Volts, rupturing capacity 10 KA 'C' series, complete all as specified and directed
Supply and fixing ceiling fan complete with blade, down rods, and accessories, 230 V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and connected from ceiling rose/ connector with & including suitable size flexible copper conductor PVC insulated sheathed cord, complete.
Supply and fix of exhaust fan, steel body AC single phase. 230 V of size 300 mm sweep with, blades, and frame and louvers and including making of holes in wall, floor etc all as directed by Engr in charge.
M & L for complete earthing with galvanised mild steel earth plate electrode of size 600x 600x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion.
M & L for Cutting existing cast iron /GI pipe in position for insertion of CI specials or GI fittings viz Tee,collar,bend or tail piece etc for 80 to 200 mm bore pipe including removing of blockage, cleaning of pipe line complete all as specified and directed by Engr-in-Charge
Supply and fixing of steel tubing galvanized medium grade with all fittings laid in trenches/ walls / Ceiling/ floor of size 25 mm dia all as directed by Engr-in-Charge.
Supply and fixing of gun metal,globe or gate valves of size 25 mm, with iron wheel head, screwed both ends for iron pipe and fixed.
M&L for construction of valve pit chamber having internal dimension 0.6m x 0.6m and depth 0.75m made of brick wall (full brick wall) with subclass 'B' bricks, straight or curved on plan exc 6m mean radius and built in CM 1:6. incl plastering exposed surfaces with CM 1:4 and provn of pre cast valve pit cover of RCC, 50mm thick with opening handle complete.
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured cable 16 sq mm 4 core cable confirming to IS-7098 Part-I (1988) with latest ammendments of sizes.
Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured cable 16 sq mm 2 core cable confirming to IS-7098 Part-I (1988) with latest ammendments of sizes.
Material and labour for cutting of bituminous road / floor / culvert / PCC hard standing for laying of pipe / cables not exceeding 1.5 meter wide and not exceeding 1.5 meter deep including refilling / with material and , watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified and directed.
Supply & laying dry river sand as cable cushioning 15cm thick layer before laying and 8cm thick over cable after laying the cable in trench complete all as specifieds and directed.
Supply & laying dry bricks over cable as mechanical protection layed flat with width equal to length of brick with sub class 'B' bricks complete all as specifieds and directed.
Material and labour for GI pipe ''light grade'' for road crossing / on wall / on pole with fixed clamps, nuts, bolts for cable protection of size 40 mm dia complete all as specifieds and directed.
CELMAC REGD
M/S PARAMJEET SINGH
STAR CONSTRUCTIONS
M/S ANIL MAHAJAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .