Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
10 Feb 2025, 3:00 pmClosed
Executive Engineer, ED-III
Office of the Executive Engineer, ED-III
Creation of 2 x 100 KVA Sub-stations along with HT/LT network at Battalion HQ Molu and Hamirpur Kona under deposit contribution works falling under the jurisdiction of Sub Division Janipur on turnkey basis
2025_PDD_270614_1
ED-III/Jammu/52 of 2024-25
Open Tender
Electrical Works
Item Rate
30 days
Jurisdiction Of Janipur
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Executive Engineer, ED-III
₹70,000
19 Feb 2025
18 Jan 2025
11 Feb 2025
18 Jan 2025
10 Feb 2025
18 Jan 2025
Amount
Creation of 2x100 KVA Sub Station (1x100 KVA Sub Station at Battalion HQ Molu) + 1x100 KVA Sub Station at Hamirpur Kona ) Providing/Supplying, Erection/Installation, Testing & commissioning comp Job)
11/0.433 KV, 3 Phase 100 KVA Distribution Transformer with Bi-Mettalic Terminal Connectors (Energy Level-2) Aluminium wound with externally fitted MCCB with cable box and 4x4 mtrs. Suitable cable of ratings
Gapless Surge Arrester, 9 KV, 10 KA, LA with Polymer housing Station Type
11 KV GO, AB Switch 3 Phase, 3 Pole, 200 amp, vertical type
11 KV Horn Gap Fuse Set 3 Phase, 200 amp
185 mm² Single core cable, 1.1KV Grade, PVC insulated stranded conductor FRLS type
ST Poles 9 Mtr Long (ST -410 SP 33)
11 KV Polymeric Composite Disc Insulators 12KV, min following load 45 KN, Lightening impulse 75KV positive and 80KV negative, creepage distance 320mm with Fittings
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts & Bolts
Earthing of Sub-Station -Excavation of earth pitof diameter 650mm and deapth 3000mm, installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5m long as per IS 1239 GI Strip for neutral earthing of size 25mm into 3 mmfor connection of transformer body, GO Set and lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement material
11 KV Polymeric composite Pin Insulators 12KV, 5KN,lighting inpulse 75KV positive and 80KV negative, creepage distance 320mm
Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete
Wedge Connectors/ PG Calmps
Danger Plates with Clamps
GI Barbed wire for Anti Climbing
Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum/pole
Painting of Poles Red-Oxide
Painting of Poles Aluminium Paint
Prodigy Meter
Sundry items like Aluminium Lugs, Jumpers, Binding Tape Aluminium Thimbles etc.
Laying of 0.30Km 11 KV line on PCC Poles 9.0 Mtr long using ACSR Weasel for Creation of 1x100 KVA Sub Stn. At Battalion HQ Molu ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job)
PCC Poles 9 Mtr Long (WL: 300 Kg)
GI Channel X-arm including clamp and braces
ACSR Weasel Conductor(30 mm²)
PG clamps for 30 mm2 ACSR conductor
11 KV Polymer composite Pin Insulators 12KV,5KN, Lighting impulse 75KV positive and 80KV negative, creepage distance 320mm
11 KV Polymer composite Disc Insulator 12KV,min falling load 45KN, Lighting impulse 75KV positive and 80KV negative, creepage distance 320mm
Galvanized nuts & Bolts
Danger Plates with Clamps
Anti Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip
Stone Pad
Aluminium Jointing sleeves
Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete
Laying of 0.30Km 11 KV line on PCC Poles 9.0 Mtr long using ACSR Weasel for Creation of 1x100 KVA Sub Stn. At Hamirpur Kona ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job)
PCC Poles 9 Mtr Long (WL: 300 Kg)
GI Channel X-arm including clamp and braces
ACSR Weasel Conductor(30 mm²)
PG clamps for 30 mm2 ACSR conductor
11 KV Polymer composite Pin Insulators 12KV,5KN, Lighting impulse 75KV positive and 80KV negative, creepage distance 320mm
11 KV Polymer composite Disc Insulator 12KV,min falling load 45KN, Lighting impulse 75KV positive and 80KV negative, creepage distance 320mm
Galvanized nuts & Bolts
Danger Plates with Clamps
Anti Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip
Stone Pad
Aluminium Jointing sleeves
Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete
Laying of 0.25 KM LT line on 4 Pole structure 11 Mtr. ST Poles using 120 mm2 XLPE Cable with provision of spare cable at Hamirpur Kona (Supplying, Installation, Testing & commissioning comp Job)
ST Poles 11 Mtr Long (ST-410 SP 56)
120 mm2 3.5 core (LT) Cable 1.1 KV Grade, Armoured, XLPE insulated Stranded conductor FRLS type (2x250 Mtr.)
SWR 16 mm as support wire for river crossing
GI channel cross-arm, braces, belts, clamps, hooks etc.
Cable Pulley wheel
D- clamps complete
Cable Termination Kit outdoor type
Galvanized nuts & Bolts
Danger Plates
Anti Climbing Devices with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip
Cement Bottoming 1:2:4 mix as per REC standards .45 cum/pole
Red oxide
Aluminium Paint
PG clamps
Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete
Laying of 0.20 KM LT line on PCC Poles 8.0 Mtr long using 120mm2 AB Cable for dispersal of power from newly created 1x100 KVA Sub station at Battalion HQ Molu ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job)
PCC Poles 8 Mtr Long (WL: 200 Kg)
120 mm2 AB (LT) Cable (3x120+1x16+70 mm2) XLPE (1.1kv, 3+1 C, Al)
Suspension/Tension Clamp with eye hook
Galvanized nuts & Bolts
Danger Plates
Anti Climbing Devices with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip
Stone pad
Insulating Piercing Connectors
PG clamps
Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete
Laying of 1.7 KM LT line on ST Poles 8.0 Mtr long using 50mm2 AB Cable for dispersal of power from newly created 1x100 KVA Sub station at Hamirpur Kona ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job)
ST Poles 8 Mtr Long (ST-410 SP 15)
120 mm2 AB (LT) Cable (3x120+1x16+70 mm2) XLPE (1.1kv, 3+1 C, Al)
Suspension/Tension Clamp with eye hook
Straight Through Cable jointing kit
Galvanized nuts & Bolts
Danger Plates
Anti Climbing Devices with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip
Cement Bottoming 1:2:4 mix as per REC standards .45 cum/pole
Red oxide
Aluminium Paint
Insulating Piercing Connectors
PG clamps
Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete
The Trikuta Engineer (BID ID -2322815)
Madina Electrical Works (BID ID -2328542)
Raina Builders and Suppliers (BID ID -2328418)
M/S APR CONSTRUCTIONS (BID ID -2328280)
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .