Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹21.4 L+₹87,369.70 (4.26%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹21.8 L+₹1.3 L (6.35%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹22.7 L+₹2.2 L (10.8%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tender | |
| 5 | L5₹22.8 L+₹2.3 L (11.2%)Rejected-Finance NAKA CHANDRA WADANI NAHARWALI MATA ROAD LASHKAR GWALIOR MP | GWALIOR | GWALIOR | MP | L5 | Rejected-Finance Not being lowest tender |
Tender Value
₹20.8 L
EMD Value
₹41,560
Closing Date
13 Dec 2021, 6:00 pmClosed
GE AF TA
GE AF TA GWALIOR-474020
SPECIAL REPAIR OF POWER HOUSE UNDER 40WING IN TECH AREA AT AF STN GWALIOR
2021_MES_489727_1
8900/1346/GWL/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) TA Gwalior
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF TA GWALIOR
₹41,560
Yes
6 Jan 2022
23 Nov 2021
21 Dec 2021
23 Nov 2021
13 Dec 2021
6 Dec 2021
Amount
Demolition of cement concrete ( unreinforced) ground floors and pavings n. exc 15 cm thick below or above ground level complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
M&L for non skid ceramic joint less coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. , laid over 15mm thick screed bed in cement mortar 1:6 incl joining in neet cement slurry and pointed in coloured cement to match with shade of tiles complete all as specified and directed.
M&L for glazed ceramic tiles coloured ,Glazed ceramic tiles in vertical surface 450X 300X 7mm thick mm thick as on walls over and incl 10mm thick rendering in cement mortar (1:4) and jointing in neet slurry and pointing in coloured cement to match the inside of tiles all complete as specified and directed.
M&L for 3 mm thick PVC tiles/ sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors all including removal of existing flooring as specified and directed. Make: WONDERFLOOR/MARVELVINYL
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. & Brushing neat cement slurry with 3.0kg of cement per sq. Metre all as specified and directed.
M&L for Machine cut kota stone slab flooring 18-22mm thick over 15mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 12mm thick Endura designer tiles of size n. exc 0.16 Sqm any colour and shape with grey cement and pigment set, jointed and pointed on neat cement slurry as in floors including 15 mm thick screed bed with bedding layer in CM (1:4) complete all as specified and directed. Make DUROTA/JOHNSON.
M&L for 75 mm thick PCC (1:3:6) type C2 (40 mm graded stone agg) as in plinth protection , finished even and smooth without using extra cement,complete all as specified and directed.
Demolition of brick work or stone boulders masonry built in cement mortor or cement lime mortor including all quoins arches pillars etc., but excluding ashlar facing dressed stone work and precast concrete articles, complete all as specified and directed.
M&L for Brick work with sub class “B” Bricks built in cement mortar 1:6 straight on plan using old size bricks all as specified and directed.
Taking down of cement plaster on brick walls etc incl hacking out joints hocking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering on brick work or concrete surfaces of wall in CM 1:6 finished even and fair complete all as specified and directed.
M&L for preparation of new plastered surfaces on walls of any height and apply two coats of oil bound distemper overone coat of wall care putty on plastered surfaces of wall complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces of wall in CM(1:4) surface finished even and fair with @ 200 ml WPC (liquid type) per bag of cement complete all as specified and directed. Note:-WPC (liquid type) shall be measured and paid separately as supply only.
M&L for preparing new plastered or unplastered surfaces of wall, pillasters, cornices etc complete etc and applying two coats of exterior emulsion paint (ACE from Asian Paint or equivalent make as specified) over a coat of primer complete all as specified and as directed.
M&L for 5 mm thick rendering on fair faces of concrete surfaces as in ceiling, in CM(1:3) and surface finished even and fair complete all as specified and directed.
M&L three coats of white wash on new plaster surfaces of ceiling including preparation of surfaces all as specified and directed.
Taking down Chowkats or frames not exc 1.5 Sqm each with shutters /without taking off shutters from the frames all as specified and directed.
Taking down Chowkats or frames exc 1.5 sqm but n.exc 4 sqm each with shutters (without taking off shutters from the frames) all as specified and directed.
Providing and fixing Powder coated aluminium (minimumthickness of powder coating 50 micron) frame work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief
All as per item No 21 above but for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and taking provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket/Sealent etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all as specified and directed.
M&L for PCC (1:2:4) B-1, using 20 mm graded stone aggregates, as in kerb/benching/coping, bed plates, for fixing hold fast, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
S&F 5mm thick tinted Glass fixed to aluminium frame /shutters exc 0.5 Sqm each comlplete all as specified and as directed.
S&F 4mm thick tinted Glass fixed to aluminium window/ ventilator shutters comlplete all as specified and as directed n.exc 0.5 Sqm each comlplete all as specified and as directed.
S&F 3mm thick Figured glass, pin head type and glazing to aluminium frame/ shutters all as specified and directed.
S&F powder coated aluminium grills size 8mm thick and aperture n.exc. 80 mm width and including fixing with aluminium channel, 1 mm thick with steel screw and tint match with existing complete all as specified and as directed.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel all as specified and directed.
S & F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS Square tube complete all as specified and directed.
S&F factory made solid PVC moulded door shutter 28-30mm thick (stiles) with 2, 4, or 6 raised panel design with 2mm thick moulded PVC prelam sheet any on the front face and 2mm plain color PVC sheet on back face and supplying & fixing in frame at site as per specification and drawing complete all as specified and directed.
S&F MS butt hinges medium weight cold rolled and fixed 100 mm long all as specified and directed.
S&F Aluminium anodised powder coated barrel tower bolts of extruded section and fixed 150 mm long all as specified and directed.
S&F 150mm long Extruded aluminium powder coated alloy handles, fabricated type, anodised complete all as specified and directed .
S&F 100mm long aluminium powder coated barrel tower bolts, of extruded section complete all as specified and directed .
S&F 100mm Butt hinges, extruded aluminium alloy powder coted with galvanised mild steel hinge pin, anodised and fixed, type B-21 all as specified and directed.
S&F Aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding both of extruded sections of cast aluminium alloy 300 mm long all as specified and directed.
Demolition of cement concrete ( unreinforced) in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including existing roof treatment (screed plaster, & tarfelt of any description) and removing to a distance exc. 500 m and n.exc. 5 Km from site complete all as specified and directed. complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in benching, kerbs and levelling course etc over roof surface complete all as specified and as directed
M & L for 10 mm thick screed bed in cement mortar 1:4 mixed with using liquid water proofing compound as per manufacturers instructions (Note:Water proofing compound shall be measured and paid seprerately under respective item of "BoQ") over roof top surface finished even and smooth using extra cement all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
M & L for application of water proofing treatment using APP modified roof membrane over existing inaccessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying bitumen primer @ 0.40 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap by authorized applicators. Physical property of membrane shall be as under:- (i) Membrane weight not less than 3.60Kg/Sqm. (ii) Non woven polyster weight not less than 160gsm/Sqm. (iii) Softening point of membrane not less than 150 degree celcius. (iv) Joint tensile strength- longitudinal not less than 650Sqcm and transverse not less than 450/Sqcm at 230degree celcius. (v) Tear Strength - Longitudinal not less than 300N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (WPC shall be measured & paid separately) Make: IWL India Ltd / STP / Pidilite Industics Ltd etc
M&L for Applying a coat of bituminous aluminium paint over bituminous surface complete all as specified and directed..
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 all as specified and directed.
S&F in repair Vitreous China wash down water closet pan pedestal pattern), with P or S Trap white including Plastic water closet seat, closed pattern with flat bottom, and cover and suitable hinges all as specified and directed. Make:- Hinware /CERA/Parryware
S & F in repair vitreous china wash basin, any colour, counter top oval size 550 X 450mm including 32mm Brass CP waste Coupling and PVC Waste pipe, CP Grating complete all as specified and directed. Make:- Hinware /CERA/Parryware.
S&F in repairs Vitreous China Urinal, Half stall type, white including CP Brass waste coupling, PVC waste pipe & CP Grating all as specified and directed. Make:- Hinware /CERA/Parryware
S&F in rep[airs 15mm bore pillar taps, fancy type, chromium plated screwed down high pressure with or without lettered with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs 10 litre capacity PVC valve less symphonic action type flushing cistern low level , white, with inlet, ball valve, float and handle including brackets and Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed. Make:- Hinware /CERA/Parryware
S&F in repairs Health Faucet Cromium Plated with one meter pipe all as specified and directed. Make: Jaquar/Parryware/ Prayag
S&F in repairs 15mm bore chromium plated long body bib taps with crutch or butterflly handle fancy type screwed down screwed for iron pipes or for brass ferrule complete all as speified and directed.
S&F 15mm bore Angle Cock / stop Cock, Brass CP, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specified and directed.
S&F in repair for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repair 110 mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches ,floor or in wall complete all as specfied and directed.
S&F in repairs 75 mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches ,floor or in wall complete all as specfied and directed.
S&F 110mm PVC(SWR) bends complete all as specfied and directed.
S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal all as specified and directed.
S&F 75mm PVC (SWR) floor trap, plain with CP grating including jointing with solvent cement all as specified and directed.
S&F 75 mm PVC (SWR) vent cowl all as specified and directed.
S&F 110 mm PVC (SWR) vent cowl all as specified and directed.
S&F in repairs 20mm bore Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe all as specified and directed.
S&F 500 lit capacity rotational moulded ploythylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position with 20mm dia Float/Ball valves high pressure of PTMT(Make: Prayag) with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) including dismantling old PVC tank complete all as specified and directed.
Supply and fixing 15mm bore medium grade galvanized iron tubing with all fittings e.g. socket, union, nipple etc. including taking down existing pipe complete all as specified and directed
Supply and fixing 20mm bore medium grade galvanized iron tubing with all fittings e.g. socket, union, nipple etc. including taking down exixting complete all as specified and directed
M&L for Cutting chases for concealed water tubing or concealed conduit wiring, etc. making good to facings where required and pointing in cement mortar 1:3 not exc 10 cm girth complete all as specified and directed.
M&L one coat of synthetic enamel paint to old steel surfaces incl preparation of surfaces complete all as directed by Engineer-in-Charge.
M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, and filling the cracks and depressions with putty/ chalk whitening to make the surface even and smooth matching to the adjacent wall surfaces and applying two coats weather coat exterior emulsion (Make : ACE of Asian Paints or equivalent in Berger Paints etc), over a coat of primer white or tinted as approved complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of wall, pillasters, cornices etc complete etc and applying one coat of exterior emulsion paint incl filling the cracks/depressions with wall putty complete all as specified and as directed. Make: (ACE from Asian Paints or Narolac Suraksha Plus)
M&L for prepration of old surface and applying one coat of distemper oil emulsion, white or tinted, incl filling the cracks/depressions with wall putty complete all as specified and as directed all as specified & directed.
M&L one coats of oil bound Distemper on old decorated ceiling surfaces including preparation of surfaces incl filling the cracks/depressions with wall putty complete all as specified and as directed all as sfd and directed.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately), removing from site and making good disturbed surfaces of walls, floors, etc. to match the existing all as specified and directed.
Disconnecting & taking up or down existing unserviceable sub main wiring of aluminium conductor of any description, any size & in any position including taking out existing unserviceable conduits or battens of any description and making good the disturbed surfaces to the existing surfaces all as specified and directed. (NOTE : Two run of single core PVC cable and one run of earth conductor with conduit / batten shall be measured as one unit.)
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6.0 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit of dia not less than 20mm with standard accessories, insulated , unsheathed, stranded copper conductor also of size 6.0 Sqmm as earth continuity conductor all as specified and directed. Note: Two runs of single core PVC insulated copper conductor, one run of earth continuity conductor and one run of conduit shall be measured as one unit.
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4.00 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit of dia not less than 20mm with standard accessories, insulated , unsheathed, stranded copper conductor also of size 4 Sqmm as earth continuity conductor all as specified and directed. Note: Two runs of single core PVC insulated copper conductor, one run of earth continuity conductor and one run of conduit shall be measured as one unit.
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit of dia not less than 25mm with standard accessories, insulated , unsheathed, stranded copper conductor also of size 10 Sqmm as earth continuity conductor all as specified and directed. Note: Two runs of single core PVC insulated copper conductor, one run of earth continuity conductor and one run of conduit shall be measured as one unit.
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduits (Medium grade) of size not less than 20 mm dia all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
Ditto as per Srl item No 76 above but point wiring for one 5 pin S/S combination 5 Amp independent with cable 1.5 sq mm size stranded copper conductor PVC insulated & unsheathed cable.
Ditto as per Srl item No 76 above but point wiring for one six pin switch socket outlet combination, 15 Amps & 5 Amp (independent) with using 2.5 Sqmm (nominal area) stranded copper conductor and 2.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete -ditto-
Material and labour for Flame proof point wiring complete with 1.5 Sqmm single core FRLSH PVC insulated and unsheathed cable voltage upto and including 1100 Volts grade multi-stranded copper conductor drawn through and including Flame proof stove enamelled steel conduit medium grade 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes,Metallic hose and cable glands etc, Concealed/ surface type on stone/brick masonry walls, roofs, floors etc by means of steel saddles and clips etc as required at site etc.including provision of 1.5 Sqmm FRLSH PVC insulated and unsheathed stranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for the following:- (a) One Flame proof light/Fan point controlled by one Flame switch complete .
Material and labour for Flame proof point wiringfor S/S combination 16 A complete with 2.5 Sqmm single core FRLSH PVC insulated and unsheathed cable voltage upto and including 1100 Volts grade multi-stranded copper conductor drawn through and including Flame proof stove enamelled steel conduit medium grade 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes,Metallic hose and cable glands etc, Concealed/ surface type on stone/brick masonry walls, roofs, floors etc by means of steel saddles and clips etc as required at site etc.including provision of 2.5 Sqmm FRLSH PVC insulated and unsheathed stranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for the following:- (a) One Flame proof light/Fan point controlled by one Flame switch complete .
Supply, fixing, connecting & testing VTPN DB DD 12 way IP-43 suitable for upto 125 Amps MCCB as incommer and SP/ TP as out going complete all as specified & directed by Engineer-in-Charge, Note: Fittings like MCB’s/Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. ) Make C&S Cat CSDB MCCB 125 DD 12 P
Supply, fixing, connecting & testing sheet metal enclosures double door TPN MCB DB 4 way. complete all as specified & directed by Engineer-in-Charge
Supply and fixing sheet metal enclosure for double door MCB DBs, phosphatised, powder coated, Single Pole & Neutral (SPN), suitable for 8 way, 240 volts, IP 43 & IK 09 fixed on wall with din rail, neutral and earth bar, in proper position all as directed by the Engineer-in-Charge. (Make: Legrand Cat No : 6077 11 or equivalent siemens/ ABB).
supply/Fixing switch piano, flush type of any description, single pole, one way 5 Amps, 230 volts AC circuit complete all as specified & directed by Engineer-in-Charge.
supply/Fixing switch piano, flush type of any description, single pole, one way 15 Amps, 230 volts AC circuit complete all as specified & directed by Engineer-in-Charge.
S&F MCCB, 4 pole, 125 Amps current rating and ultimate breaking capacity Icu = 25 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed. Make :- Legrand/Havels/L&T
Supplying & fixing MCB TPN 63 Amp C series complete all as specified and directed. Make:Control & switch gearcat part No.CSMBS3C 63 N
Supplying & fixing MCB SP, 6 to 32 Amp (`C’ series ) complete all as specified and directed. Make:-C&S Cat patr No.CSMBSI C6 to C32
Supply & fixing MCB Single Pole and Neutral (SPN) of capacity 63 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position all as directed by the Engineer-in-Charge. (Make: Legrand or equivalent siemens/ABB).
Supply & fixing MCB Single Pole and Neutral (SPN) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position all as directed by the Engineer-in-Charge. (Make: Legrand or equivalent ).
Supply and fixing ceiling rose, surface bakelite 65 mm x 50 mm size with three terminals all as specified and as directed by the Engineer-in charge. (Make :- ANCHOR or equivalent)
Supplying & fixing flame proof weather proof switch socket & plug combind 16 A,250V (2P+Earth) Complete all as specified and directed.
Supplying and Fixing Switch socket combitation 5 in 1 flush type 5A/16A independent complete all as specified and directed.
Supplying and Fixing Switch socket combitation 2 in 1 flush type 5A indpendent complete all as specified and directed.
Supply and Fixing ceiling fan regulator, 2 M 100 W rotary step type all as specified and as directed by the Engineer-in-Charge.
Supplying and Fixing Exhaust fan AC single phase 230/240 V of size 450 mm sweep heavy duty with louvers complete with making holes . all as specified and directed. Make Havells model Turbojet or equivelent make
Supplying and Fixing Exhaust fan AC single phase 230/240 V of size 300 mm sweep with louvers Make Havells model Turboforce 3 blade .or equivelent make . complete all as specified and directed.
Supplying and Fixing Air circulator fans AC single phase 230 Volts oscillating 600 mm sweep heavy duty suitable for wall mounting Complete all as specified and directed.Make Havells model Turboforce or equivalent make
Supplying and Fixing ceiling fans compleate with accessories 230 Volts 1200 mm sweep Complete all as specified and directed.
Supplying & fixing flame proof weather proof tube light 1X40 WX 4' Complete all as specified and directed.
Supplying & fixing Flextron VIVA LED batten fitting 20 watt and including all accessories pr- wired and connecting the same two ceiling rose to three core PVC insulated and sheathed copper conductor 1.5 sqmm cable including all accessories and fixing arrangement for fixing the light fitting to walls / roof surface complete all as specified and directed. Make :Bajaj cat part No BLTRU 20W WH VIVA or equvlaint
S & F Street/ security light luminaire, energy efficient, Pressure die cast aluminium housing LED street light luminaires with IP66, 70W LED including LED lamp and connecting up with 2.5 Sqmm multistranded copper conductor cables not less than 3 metre of length with Ariel fuse, fixed to pole/wall, etc and testing complete all as specified and directed. (Make : Bajaj product code No. 169681, luminaire type BRTFG 70W LED or equivlant model of Havell's/Philips/CG as approved).
Supply & fixing energy saving environment friendly, long life exclusive innovative die cast aluminium IP66 flood light 100 Watt LED 6000Kwith high power LEDS as light source complete including suitable fixing arrangement on pole ,pillar , wall with suitable fastenerrs ,nut, bolt clamps and making connection with three core copper conductor cable not less than 1.5 sq mm complete all as specified and directed .
Supply and Fixing connecting only flame proof push button/rotary type switch of any description , any capacity or make complete all as specified & directed .
Supply and Fixing flame proof ,switch socket & plug combined made of aluminum alloy LM -6 having 2 pole + earth suitable for 250 volts supply and current rating of 16 Amp complete all as specified & directed. make / model Sudhir cat part No.SS/OA/1010-1 or equivalent model of other make as specified.
M&L for Earthing complete for poles/ DBs with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m deep below normal ground level with top edge of earth plate, not less than 1.5 m below normal ground level, connected to galvanised iron earth lead of size 4.0 mm dia by means of bolts, nuts/check nuts and washers etc of galvanised iron, protected by galvanised iron pipe light grade 15 mm dia upto a length of 7.5 m away from earth electrode and connected to main switch/control board including necessary excavation & earth work in any type of soil and PCC 1:3:6 type C1 for earth chamber, 40 mm thick RCC cover slab 1:2:4 type B1 with 6 mm dia TMT Bars at 140 mm c/c both ways, watering pipe 20 mm dia light grade GI, funnel, wire mesh, lugs, charcoal and comman salt etc complete all as shown in Electrical plate No. 3 of SSR Part I and testing complete all as specified and directed.
Supply & fixing Single phase and neutral enclouser 6-32 Amp, with two pin and earth plug and socket encluding one single pole MCB .all as specified and directed.
Supply and fixing Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amps .
Supplying ,laying and testing LT cable XLPE insulated ,screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium stranded conductor 1100 volt grade of 50 Sqmm 3.5 core size in trenches / fixed to walls/drawn in conduit/laid in floor complete all as specified and directed.
Supplying ,laying and testing LT cable XLPE insulated ,screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium stranded conductor 1100 volt grade of 25 Sqmm 3.5 core size in trenches / fixed to walls/drawn in conduit/laid in floor complete all as specified and directed.
MOHAN SINGH BHADORIA
YASH DEVELOPERS AND CONSTRUCTION COMPANY
SHRI RAM CONSTRUCTION
M/s JAY AMBEY CONSTRACTION .CO
JNK BOND
M/S STEAD FAST
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .