Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC HYDERPORA NEAR ELLAQUAI DEHATI BANK SRINAGAR KASHMIR J K 190014 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190014 | L1 | Accepted-AOC Contract awarded to M/S Zahoor Ahmad Khan by the committee due to L1 | |
| 2 | L2₹38.2 L+₹16,634.60 (0.44%)Rejected-Finance BETONG SHOP KHANGSAR COMPLEX NOWSHARA LEH LADAKH 194101 J K | LEH | LEH | JAMMU AND KASHMIR | 194101 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹39.6 L+₹1.5 L (4.02%)Rejected-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹39.6 L+₹1.5 L (4.04%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹39.7 L+₹1.6 L (4.32%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
12 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Khumbathang
HQ CWE Khumbathang PIN-900270 C/o 56 APO
SPECIAL REPAIR TO 01X250 KVA DG SET AGAINST BER AT KHUMBATHANG UNDER GE KHUMBATHANG
2025_MES_709270_1
80051/10/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
Khumbathang
CLASS D Cat b (i)
8 documents required · 8 mandatory
₹500
GE Khumbathang
₹72,000
5 Aug 2025
20 May 2025
13 Jun 2025
20 May 2025
12 Jun 2025
4 Jun 2025
Amount
Supply and installation, testing and commissioning of diesel engine driven generating set of capacity 250 KVA (200 KW), 4 cylinder in line 4 stroke,415 Volts, 0.8 power factor at NTP, mounted on common base frame with flexible coupling, 1500 RPM, with silencer pipe protected with asbestos rope independently supported from engine to outside of power house up to 0.50 metre, AVM pads, PCC 1:2:4 type B-I (using 20mm graded crushed stone aggregate) foundation as per manufacturer's design, cold starting kit, battery start with suitable cables for connecting from DG set to panel board and with first fill of lubricant oil and coolant (DG set shall be capable of operating in temp range of (-35°C to + 35°C) complete with and including the following:-
(A) PRIME MOVER. Vertical engine of suitable capacity water cooled (Radiator mounted) EG complete 50:50, bore 95x115mm, CR 19:1, Displacement 3.3 ltr, ISO 8528-5 G2, CI4+ 15W40, exhaust pipe size 3 inch, mean piton speed 5.75 m/sec, air intake @ 100 % load 160 CFM, exhaust temp 490 degree celcius, closed circuit as per BS-649 or IS-10002 direct injection type turbo charged electric starting system having rated speed 1500 RPM. DG Set conforming IS/IEC 60034-1, IS 1460, ISO 8528/3046/9001 AND IS 13018. Engine protection low lubricant oil pressure, high/low coolant temp, battery over/under/weak volts, fail to crank/start, sensor failure, cranking lockout, low fuel level and alternator protection over/under voltage, over/under frequency, loss of ac sensing etc.The DG set shall be capable of running 24 hours continously with 10% overloading for one hour in every 12 hours run as per BS-5514/BS-649. Engine shall be equipped with all standard fitting as per manufacturer's recommendations and mounted on common base frame with following fittings:-
(a) RPM cum hour meter (b) Battery charging ammeter (c) Ignition key and starting with push button switch (d) Lubricating oil pressure guage. (e) A-1 Governor controlling. (f) Oil tempature gauge. (g) Water tempature gauge. (h) Lub oil coolant heater to avoid freezing. (j) Oil drain pump (k) 24 Volts cold starting kit comprising with the following:- (i) 2 Nos, 12 volts 180 AH batteries. Make: Exide/Standard /Amaron. housing in wooden box with glass wool insulation all around as directed. (ii) Battery Charging alternator with inbuilt regulator (iii) Starter motor of suitable capacity. (iv) Battery leads(copper cable) of suitable size with brass thimbles and terminals. (l) Cold starting kit with engine block heater and sump heaters. (m) Any other fitting/accessories as recommended by the manufacturer.
(B) ALTERNATOR. Alternator rating 250 KVA (200 KW), 3 phase, 50 cycles 415 Volt, 4 wire supply at NTP 0.8 power factor running @ 1500 RPM self excited, self regulated , mounted on a strong fabricated steel frame suitable for mounting on a permanent foundation to be coupled with above engine. Voltage regulation plus minus 1 %, insulation class H, winding pitch 2/3, stator winding double layer lap, dynamically balanced rotor, waveform distotion no load < 1.5 %, total harmonic distortion non distorting balanced linear load <5 % , max unbalanced load across phases <= 25%.Dedicated winding specially designed for 1 phase operation.The alternator shall be conforming to IS/IEC 60034-1, BS-2613 of IS-4722. (C) Alternator control panel CRCA sheet, floor mounted, cubical type with internal copper wiring with copper coductor cable of suitable size for 250 KVA alternator, 415 volts, 3 phase 4 wire, 50 cycles fabricated out of 1.6 mm thick MS sheet, painted internally and externally with two coats of epoxy powder coating paint over a coat of red oxide primer, including following accessories:-
(b) Fuel tank with provision of cleaning of suitable capacity as per manufacturer's instructions capable to store 12 hours running of DG set with supprting fabricated steel stand with all pipes connecting upto fuel pump including oil level indicating gauge, drain & air vent plug etc. (c) silencer to meet MoEF/ CPCB noise emmission standards. (d) Rubber matting. Chequred of size 2m x 1m x 12mm thick (Make Jyoti or equivelent (ISI Marked) (e) Tool kit for maintenance of DG set NOTES FOR ITEM NO-1 (i) The DG Set shall be provided with an intergral acoustic enclosure to meet MoEF/CPCB norms of 75dBA @ 1 metre at 75 % load under free field conditions, CRCA sheet in munsel green shade, structural base frame in black paint, insulation material PU foam complying IS 8183, fuel filling arrangement inside the enclosure, 11 tank pretreatment process and UV resistent powder coating of all parts to withstand extreme environment, air inlet louvers and shall comply the revised noise limit for DG set vide GSR 371 (E) dated 17 May 2002 and its amendments under Environment (Protection) act 1996 issued by the Min of Envronment and Forests. (ii) The contractor shall produce a copy of approved certificate to authanticate the above from the OEM/OEA Notes:- (i) Load test will be carried out after installation in the presence of testing officer. (ii) The DG set shall be tested by the contractor in presence of the accepting officer's representative/ IEM & Engineer-in-charge without any extra cost and the quoted rates are deemed to be included for all these aspects. (iv) Payment of DG Set's will be made after satisfactory testing.
Excavation in trenches not exceeding 1.5m in deep for laying of pipe, cable, foundation of electric pole etc and getting out in hard soil, complete all as specified and as directed by Engineer-in-charge.
Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.(Surplus soil if any shall not be removed but left over the trench), complete all as specified and as directed by Engineer-in-charge.
Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point, complete all as specified and as directed by Engineer-in-charge.
Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable, complete all as specified and as directed by Engineer-in-charge. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I.
Providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other, complete all as specified and as directed by Engineer-in-charge.
Supply and laying XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cable heavy duty 1100 Volt grade with stranded aluminium conductor of size 240 Sq mm 3.5 core , complete all as specified and as directed by Engineer-in-charge.
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32X6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009.00 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, I watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32X6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc, complete all as specified and as directed by Engineer-in-charge.
M/s Siachen Construction Co. (BID ID -3320761)
Vijaypower Generators Limited (BID ID -3321405)
M/S MOHD HUSSAIN (BID ID -3320569)
HEENA CONSTRUCTION CO (BID ID -3321358)
Feroz Engineering Works (BID ID -3320696)
SUMEET TRADING CORPORATION (BID ID -3321189)
KASHMIR FAIR DEAL SERVICES (BID ID -3320503)
M/S ALI MOHD AND SONS (BID ID -3320554)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .