| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.6 LAccepted-AOC 10TH MILE RISHI ROAD KALIMPONG DISTRICT DARJEELING PIN 734301 | KALIMPONG | DARJEELING | WEST BENGAL | 734301 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹61.1 L+₹53,006.19 (0.87%)Rejected-Finance | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹62.2 L+₹1.6 L (2.65%)Rejected-Finance | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹62.2 L+₹1.6 L (2.69%)Rejected-Finance | L4 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 5 | L5₹62.7 L+₹2.1 L (3.40%)Rejected-Finance | L5 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹55.9 L
EMD Value
₹1.1 L
Closing Date
3 Mar 2023, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
SPECIAL REPAIR TO BLDG NO P-215 (OR MD ACCN) AND PROVN OF RETAINING WALL AT MT AREA OF EME BN AND NEAR BLDG NO K-7, K-8 AND K-260 OF MH AT KALIMPONG MIL STN UNDER GE 867 EWS
2023_MES_578693_1
CWE/136-WE/57 OF 2022-23
Open Tender
Civil Works
Item Rate
270 days
Kalimpong
Class C, Category a(I)
8 documents required · 8 mandatory
₹1,000
GE 867 EWS
₹1.1 L
23 Mar 2023
2 Feb 2023
4 Mar 2023
2 Feb 2023
3 Mar 2023
24 Feb 2023
2 Feb 2023 - 9 Feb 2023
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed.
Dismantling timber scantlings 40 Sqcm and over in section, in any position (framed work) all as specified and directed.
S&F of Gl frame work (Size of grid 605 x 605mm) for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified and directed.
S&F of PVC false ceiling with light weight PVC hollow section panel made of 1mm thick and over all thickness of panel 7 mm thick and 200mm wide strip of coloured/ wood grain / melamine finish, fixed in new false ceiling grid made of Aluminum / GI / MS / Wooden, complete all as specified and as directed. Note: New false ceiling grid made of Aluminium/ GI/ MS/ Wooden, if provided shall be measured and paid separately.
S&F of joist, channel, angle, flat iron or tee sections, fixed independently with connecting plates, etc confirming to Fe 410-W (Gde 250 quality A), complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra lime or cement), complete all as specified and directed.
M&L for rendering 20mm thick (two layer, 10mm and 10mm thick) in cement mortar (1:4) with water proofing compound on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing, finished even and smooth (without using extra lime or cement), complete all as specified and directed. Note: Water proofing compound will be measured and paid separately
Supply only integral water proofing compond, all as specified and as directed.
M&L for rendering 5mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:3) as in ceiling/chajja, finished even and smooth (without using extra lime or cement), complete all as specified and directed.
M&L for two coats of distemper oil emulsion (OBD), over a coat of priming coat (Chalk whiting, on plastered surfaces, prepara-tory to distempering) on newly prepared wall surfaces, including 3mm thick wall care putty on wall, complete all as specified and directed.
M&L for preparation of new plastered or previously untreated surfaces of walls and applying two coats of cement paint on walls, complete all as specified and directed.
M&L preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash on ceiling, complete all as specified and directed.
M&L for scrapping of existing treatment and applying one coat 3mm thick of wall care putty and then applying two coats of distemper oil emulsion(OBD), white or tinted over a coat of priming paint (Chalk whiting, on plastered surfaces, preparatory to distempering) after preparation of wall surfaces, complete all as specified and directed.
M&L for scrapping of existing treatment on walls, washing, rubbing down and stooping of distempered and applying two coats of cement paint, white or tinted after preparation of wall surfaces, complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash on walls, complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of wall and applying one coat of white wash on walls, complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks , using old size bricks, straight or curved on plan exc 6 m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in bed blocks for grouting hold fasts, coping, filling in pressed steel chowkat or similar work including necessary form work as required, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Water proofing treatment to SUNKEN PORTION and adjoining walls of kitchen, WC, Bath & toilet etc: 15 mm thick plaster in cement mortar (1:3) after roughening and cleaning the surface mixed with WP compound as per manufacturer's instruction shall be provided on sunken portion (a) Apply cement slurry to the surface @ 0.488 kg /Sqm of cement mixed with Acrylic based polymer modified cementious complete compound @ 0.253kg/Sqm and the surface will be allowed to air cure for 4 hours. Make: Brushbond powder of SIKA INDIA PVT LTD / FOSROC CHEMICALS / STP LIMITED / HINDCON CHEMICALS LTDC (b) Apply another layer of cement slurry @ 0.242 kg/sqm of cement mixed with Acrylic based polymer modified cementious composite compound @ 0.126 kg/sqm and the surface will be allowed to the air cure for 4 hours. Make: Brushbond powder of SIKA INDIA PVT LTD / FOSROC CHEMICALS / STP LIMITED / HINDCON CHEMICALS LTD (c) Curing the sunken portion with water minimum for 48 Hrs by ponding. (d) Paste one layer of 3mm thick APP membrane with bitumen by torch application to the treated sunken surface. (e) Joints/ Traps/WC/soil pipes shall be properly sealed with approved sealing compound. (f) Testing of all traps & joints shall be done after sealing and before filling of sunken slabs.
Demolition of stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc., complete all as specified and as directed.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete over and including 20 mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
Demolition and breaking up old broken, PVC (SWR), Cast Iron, AC, SWG soil waste and vent pipe of 75/100/110 mm bore including accessories set in cement mortar and removing rubbish from site, complete all as specified and directed.
S&F of 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
S&F of 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
S&F of 110mm bore PVC (SWR) bend any radius with access door, complete all as specified and directed.
S&F of 75mm bore PVC (SWR) bend any radius with access door, complete all as specified and directed.
S&F of 110mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement, complete all as specified and directed.
S&F of 75mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement, complete all as specified and directed.
S&F of 110x75mm bore PVC (SWR) reducer including jointing with solvent cement, complete all as specified and directed.
S&F of 75mm bore PVC (SWR) vent cowl including jointing with solvent cement, complete all as specified and directed.
M&L for 75mm diameter of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed.
S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed.
S&F of PVC low level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type, complete all as specified and directed.
S&F in repairs of water closet (squatt pattern) of vitreous china squatting pan of pattern "ORRISA" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonic pipe etc complete including P or S trap set in and including necessary lean cement concrete complete all as specified and directed.
S&F in repairs of vitreous china wash basin (flat back or angle back type), angle back, size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe, complete all as specified and directed.
S&F in repair 15mm bore PVC connection 450 mm long with two brass chromium plated brass nuts and PVC washers, complete all as specified and directed.
S&F in repair 15mm bore dia stop valves, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
S&F in repair of 15mm bore dia pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, all as specified and directed.
M&L for roughening the surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, complete all as specified and directed.
M&L for coloured non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 20mm thick for laying floor finishes in cement mortar (1:6), complete all as specified and directed.
M&L for coloured non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqmas in vertical surface such as risers of steps, skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick rendering in cement mortar (1:4), complete all as specified and directed.
M&L for coloured non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 20mm thick for laying floor finishes in cement mortar (1:6), complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 15 mm thick rendering in cement mortar (1:4), complete all as specified and directed.
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each and refixing in same opening after resecuring or easing & adjusting, complete all as specified.
Taking down chowkhats or frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhats or frame exc 1.50 and not exc 4 sqm each with shutter (without taking off shutters from the frame), complete all as specified and directed.
S&F of pressed steel frame of size 125 x 60mm for door with one or more rebates including necessary fixing, lugs, hinges, lock, strike plate, etc complete all as specified.
S&F of steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
S&F steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and directed.
S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
S&F pressed steel frame of size 105 x 60mm for door with one or more rebates including necessary fixing, lugs, hinges, lock, strike plate, etc complete all as specified.
M&L for second class hard wood, 35mm thick plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and directed.
M&L for 2nd class hard wood, 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of both side Prelam PVC sheet. Stile and rails feathered at edges to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing and as directed.
S&F of solid PVC door frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing and as directed.
S&F of 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed, all as specified and directed.
S&F of 150mm long aluminium anodised, barrel tower bolts of extruded section and fixed, all as specified and directed.
S&F of 125 mm size aluminium handles, cast type, anodised and fixed, all as specified and directed.
S&F of 150 mm size aluminium handles, cast type, anodised and fixed, all as specified and directed.
S&F of 300 mm long aluminium alloy, anodised sliding door bolts with haps staple (bolt type), and fixing clips of sheet, cast or extruted sections and fixing bolt and sliding bolts of extruted sections or cast aluminium alloy and fixed, complete all as specified and directed.
S&F in repair of stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples fixed, complete all as specified and directed.
S&F of stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples fixed, complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones, all as specified and directed.
S&F of 3.0mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed.
S&F 4.0mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.50 sqm in each pane, complete all as specified and directed.
S&F in repair of kitchen sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to waste pipe; upto 0.5 sqm each, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed.
S&F in repair of kitchen plate rack made out of stainless steel 0.50 mm thick sheet with partitions and size of rack 800 x 250 x 900 mm with shape and pattern as per sample kept in Sample room of GE 867 EWS, complete all as specified and directed.
S&F in repairs stainless steel curtain rod (curtain rails) of 25 mm dia with fixing including decorattive knobs and fixiing in pairs of brackets, stops etc., complete all as specified and directed.
S&F in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed.
M&L for preparation of new wooden surfaces or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L for preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Taking down, chipping and removing the loose spailt, damaged cement concrete , cement mortar surfaces of RCC columns, beams, walls, chajjas etc and exposing the reinforced cement concrete, wire brushing and cleaning the exposed steel reinforced bar, applying rust remover over the cleaned re-bar surface, wash with clean water for removing all rusts from the old reinforcement bar surfaces, fixing new reinforcement, cut to lenghts , bend to shape required and tying with and including mild steel wire ( annealed ) not less than 0.9mm in dia for stregthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of water, Nitbond SBR ( Latex ) and cement in ratio (1:1:3) slurry as bond coat after that applying ready mix epoxy repair mortar, 40 mm average thick in any number of coats, to provide at least 30mm thick cover to reinforcement, finished the surfaces even and fair includ ing erecting and dismantling scafolding for carrying out the work complete all as specified and as directed.Make of Epoxy Ready made Mortar and Epoxy chemicals - SIKA INDIA PVT LTD / FOSROC CHEMICALS / HINDCON CHEMICALS LTD.
Note:- (i) New reinforcement will be measured and paid seperately.(ii) Cost of fixing of new reinforcement by welding / binding with old reinforcement and providing, errecting and dismantling scaffolding shall deemed to be included in quoted rates.
M&L for expanded metal of weigtht not exc 4 kg per square metre, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, complete all as specified and directed.
Rough excavation not exceeding 1.5 m deep and getting out in soft / loose soil for excavation of slope hill etc., all as specified and as directed.
Excavating over areas, exc 1.5 m deep and n exc 3.0 m deep and getting out in soft / loose soil, all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil, all as specified and as directed.
M&L for plain cement concrete (1:4:8), type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry (1:2:4), type B-1 (using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6), uncoursed, well bonded, bedded and solidly hearted, complete all as specified and as directed.
M&L for reinforced cement concrete M-25 (design mix) using 20 mm graded stone aggregates in beams, cantilevers, bressummers, lintels over 1.5m span, RCC band etc., complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and as directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and as directed.
Use and waste of timber formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, RCC/PCC bands in wall etc.; vertical or to batter for rough finished flat surfaces of concrete, complete all as specified and as directed.
M&L for plain cement concrete (1:3:6), type C1 (using 20mm graded crushed stone aggregate) as in bond stone, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
Supply and fixing of 75mm bore PVC pipe (SWR) single socketed, in any length with rubber ring joints as in weep holes, complete all as specified and directed.
M&L for raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar (1:4), complete all as specified and directed.
M&L for hand packing (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level using broken stone or boulders, all as specified and as directed.
Returning filling in soft / loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and as directed.
Removal of surplus excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point, complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed.
Dismantling and taking down unserviceable main switches, DB's including sub main wiring etc. any type / size and making good disturbed surfaces to match with the existing finishes, complete all as specified and as directed.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring, for one light point or one fan point or one bell point controlled by one switch, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one bell/ buzzer point controlled by one push button on the same board with other switches or independent, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one 3 pin socket outlet, 5 Amps on the same board with other switches, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one 3 pin socket outlet, 5 Amps on independent board, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Material and labour for point wiring with 2.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one 3 pin socket outlet, 15 Amps on independent board, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Supplied & fixed for 20 amp single pole, 240 Volt, enclosure with a two pin and earth plug and socket complete with one single pole MCB, all as specified and directed.
M&L for ceiling rose, 3 phase/PVC/ polycarbonate, isolated body, three terminal, 240 Volts, all as specified and directed.
M&L for switch piano, flush type single pole, one way 5 Amp, 240 Volts, all as specified and directed.
M&L for switch socket combination 2 in 1, 3 pin, 5 Amps flush type universal, all as specified and directed.
M&L for switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal, all as specified and directed.
M&L for bell push, flush type, 5/6 amp, 240 Volts, all as specified and directed.
M&L for buzzer, ding dong AC. 230 volts, single pole, all as specified and directed.
S&F in replacement of lamp angle/batten holder Bakelite Pin/Retrofit type, in and including with 10 watt LED Lamp (B22), all as specified and directed.
S&F of LED light fitting 1x9 Watt / 1X10 Watt bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, all as specified and directed.
Supply and fixing of LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing of LED street light fitting 35 Watt 230 Volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing of DB's with MCB incomer suitable for triple pole and neutral(TPN), double door (IP-54), 4 Ways, built-in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz complete all as specified and as directed.
Supply and fixing of 415V 10KA 'B' curve miniature circuit breaker (MCB) of triple pole and neutral(TPN) and current carrying capacity of 40 to 100 AMP in the DB complete with connection testing and commissioning, all all as specified and directed.
Supply and fixing of sheet metal enclosure, double door for MCB single pole & neutral DB's, 8 way with 200 amps rated bus bar suitable for 240 Volt, AC, 50Hz, complete all as specified and directed.
Supply and fixing of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB complete with connection testing and commissioning, all as specified and directed.
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole & neutral (SPN) and current carrying capacity of 40 to 63 AMP in the MCB DB complete with connection testing and commissioning, all as specified and directed.
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole (SP) and current carrying capacity of 5 To 32 AMP in the MCB DB complete with connection testing and commissioning, all as specified and directed.
S&F of sub main wiring with two single core 6.0 Sqmm PVC (FRLS) copper conductor, insulated multistranded unsheathed cable medium grade including PVC casing and capping of required size (not less than 32mm) conforming to IS 2079-1973 with accessories for sub main connection including 6.0 Sqmm PVC (FRLS) insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly, all as specified and directed. (Note :- Three runs of 6.0 sqmm PVC FRLS copper conductor shall be measured as one unit length)
Supply and fixing / install of new exhaust fans Metal body AC single phase 230V, size of 230MM Sweep with provn of louvers accessories and eletric connection and taling down old exhaust fan, depositing E/M store yard complete all as specified and as directed.
Supply and fixing of electric water heater (Geyser), storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc., all as specified and directed.
Taking down electric KWH meter and keep in safe custody and refixing the same as including necessary electric connection from main to KWH meter and KWH meter to out going distribution board, all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm × 60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron or steel earth lead wire 4.0mm dia size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR Part-I, connected to earthing test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil, GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of earth wire etc. upto test point, PCC chamber with PCC cover in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to DB as indicated, complete all as specified and as directed. Notes: Contractor should conduct necessary test such as earth continuity, earth resistance test in presence of Engineer-in-Charge.
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
HEM RAJ GURUNG
DEEP CHANDRA JOSHI
G K SUTHAR
MS BRAHMA CONSTRUCTION
RAMESH GURUNG
MANOJ JINDAL
ANTHONY PRADHAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .