Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC | ₹8.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹9.1 LRejected-AOC | ₹9.1 L | L2 | Rejected-AOC L2 |
| 3 | L3₹10.1 LRejected-AOC VILL KULCHOURA BUDAUN UTTAR PRADESH | SOUTH | DELHI | 110025 | ₹10.1 L | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | M/S M.G ENTERPRISES L3 | M/s Vedanta Enterprises L1 | DURGESH CHANDEL L2 |
|---|---|---|---|---|---|---|
| 1.00The work of safe carriage of the following material from Navada Badaun store center to work site under the jurisdiction of LT/11 KV Vertical under EDD Bisauli. Approx. distance upto 70 Km. Including safe loading and unloading. | ||||||
| 1.01 | PCC Pole 8.5 meter long. | 10 | Nos | 810 ₹8,100 | 700 ₹7,000 | 800 ₹8,000 |
| 1.02 | PCC Pole 11 meter long. | 17 | Nos | 910 ₹15,470 | 800 ₹13,600 | 900 ₹15,300 |
| 1.03 | STP 11 Mtr Long | 5 | Nos | 960 ₹4,800 | 850 ₹4,250 | 950 ₹4,750 |
| 1.04 | STP 13 Mtr Long | 5 | Nos | 1,100 ₹5,500 | 900 ₹4,500 | 1,000 ₹5,000 |
| 1.05 | Line material i.e., cross arm/ pin insulator/stay/earthing rod/Ms Channel/MS Angle/Disc Fitting/Disc Insulators etc | 25 | Qtl | 600 ₹15,000 | 400 ₹10,000 | 500 ₹12,500 |
| 1.06 | 11 KV XLPE Cable Size 3x70sqmm | 50 | Mtr | 40 ₹2,000 | 20 ₹1,000 | 30 ₹1,500 |
| 1.07 | 11 KV XLPE Cable Size 3x120sqmm | 50 | Mtr | 50 ₹2,500 | 30 ₹1,500 | 40 ₹2,000 |
| 1.08 | 11 KV XLPE Cable Size 3x185sqmm | 50 | Mtr | 50 ₹2,500 | 30 ₹1,500 | 40 ₹2,000 |
| 1.09 | 11 KV XLPE Cable Size 3x300sqmm | 50 | Mtr | 50 ₹2,500 | 30 ₹1,500 | 40 ₹2,000 |
Tender Value
₹10 L
EMD Value
₹10,000
Closing Date
23 Feb 2026, 3:00 pmClosed
SE, EDC, BDN
BUDAUN
32/EDCB/2025-26
2026_MVVNL_1117264_1
32/EDCB/2025-26
Open Tender
Electrical Works
365 days
BUDAUN
AS PER TENDER DOCUMENT
3 documents required · 3 mandatory
₹1,180
A/c No. 1243002100806171, IFSC Code - PUNB0124300
₹10,000
15 May 2026
18 Feb 2026
24 Feb 2026
18 Feb 2026
23 Feb 2026
18 Feb 2026
18 Feb 2026 - 23 Feb 2026
The work of safe carriage of the following material from Navada Badaun store center to work site under the jurisdiction of LT/11 KV Vertical under EDD Bisauli. Approx. distance upto 70 Km. Including safe loading and unloading.
PCC Pole 8.5 meter long.
PCC Pole 11 meter long.
STP 11 Mtr Long
STP 13 Mtr Long
Line material i.e., cross arm/ pin insulator/stay/earthing rod/Ms Channel/MS Angle/Disc Fitting/Disc Insulators etc
11 KV XLPE Cable Size 3x70sqmm
11 KV XLPE Cable Size 3x120sqmm
11 KV XLPE Cable Size 3x185sqmm
11 KV XLPE Cable Size 3x300sqmm
ACSR Weasel Conductor
ACSR Rabbit Conductor
ACSR Raccon Conductor
ACSR Dog Conductor
3 Phase Arial Bunched Conductor
1 Phase Arial Bunched Conductor
Distribution Box 1 Phase
Distribution Box 3 Phase
11 KV Cable Box Size 3x70sqmm
11 KV Cable Box Size 3x120sqmm
11 KV Cable Box Size 3x185sqmm
11 KV Cable Box Size 3x300sqmm
Straight Through
11/0.4 KV 3 Phase 25 KVA T/F
11/0.4 KV 3 Phase 63 KVA T/F
11/0.4 KV 3 Phase 100 KVA T/F
11/0.4 KV 3 Phase 250 KVA T/F
11/0.4 KV 3 Phase 400 KVA T/F
11 KV Pilfer proof Metering cubical and CT PT Unit
The Work of safe Carriage 11 KV O/G VCB store Center Nawada Budaun to work of site distance up to 0 to 30 km including safe loading & unloading.
Erection of new PCC Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms
PCC Pole 8.5 Mtr Long Single Pole
PCC Pole 8.5 Mtr Long Double Pole
PCC Pole 11 Mtr Long Single Pole
PCC Pole 11 Mtr Long Double Pole
PCC Pole 11 Mtr Long Tri Pole
PCC Pole 11 Mtr Long Four Pole
ST Pole 13 Mtr Long Single Pole.
ST Pole 13 Mtr Long Double Pole.
ST Pole 11 Mtr Long Single Pole.
ST Pole 11 Mtr Long Double Pole.
ST Pole 11 Mtr Long Tri Pole.
ST Pole 11 Mtr Long Four Pole.
Grouting with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/Concreate & sand Required as per RESSPO Norms
PCC Pole 8.5 Mtr Long Single Pole
PCC Pole 8.5 Mtr Long Double Pole
PCC Pole 11 Mtr Long Single Pole
PCC Pole 11 Mtr Long Double Pole
PCC Pole 11 Mtr Long Tri Pole
PCC Pole 11 Mtr Long Four Pole
ST Pole 13 Mtr Long Single Pole.
ST Pole 13 Mtr Long Double Pole.
ST Pole 11 Mtr Long Single Pole.
ST Pole 11 Mtr Long Double Pole.
ST Pole 11 Mtr Long Tri Pole.
ST Pole 11 Mtr Long Four Pole.
Dismantling of PCC/ST Pole due to line shifting/damaged complete in all respect
ST Pole 9 Mtr Long Single Pole.
ST Pole 9 Mtr Long Double Pole.
ST Pole 11 Mtr Long Single Pole.
ST Pole 11 Mtr Long Double Pole.
ST Pole 11 Mtr Long Tri Pole.
ST Pole 11 Mtr Long Four Pole.
LT ABC (3x95+1x70+1x16) SQ. MM
LT ABC (3x120+1x95+1x16) SQ. MM
Dismantling of Old and damaged conductor complete in all respect
The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms
Dismantling of Existing Distribution Transformer for increasing capacity/Shifting complete in all respect
11/0.4 KV 3 Phase 25 KVA T/F
11/0.4 KV 3 Phase 63 KVA T/F
11/0.4 KV 3 Phase 100 KVA T/F
11/0.4 KV 3 Phase 250 KVA T/F
11/0.4 KV 3 Phase 400 KVA T/F
Laying, Stringing & Sagging of Following Conductor complete in all respect
ACSR Weasel Conductor
ACSR Rabbit Conductor
ACSR Raccon Conductor
ACSR Dog Conductor
3 Phase Arial Bunched Conductor
1 Phase Arial Bunched Conductor
Erection and fixing of Overhead Line By XLPE Cable Complete in all respect.
11 KV XLPE Cable Size 3x70 sqmm
11 KV XLPE Cable Size 3x120 sqmm
11 KV XLPE Cable Size 3x185 sqmm
After Mounting of CT PT unit on double pole, laying of 50 Mtr 11 KV 3cx70 sq mm cable in single circuit on river sand form Double Pole to metering room complete in all respect. Alongwith filling of 04 nos cable jointing kits
Installation of 11 KV Pilfer Proof Metering Cubicle in metering room complete in all respect
Erection/Installation of following of VCB O/G in Consumers Site and Cable Joint of the panel to including earthing, grouting, Anchor bolt of panel of making/repairing of pocket for cable to insert in panel form trench and fixing taping of busbar with wiring for AC,DC Connection including providing AC and DC Supply.
Under ground laying of Following cable in Single circuit on river sand to Double pole situated at both sides of road complete in all respect. Minimum depth should be 0.75 Mtr and cable should be covered by bricks from three sides. Along with filling of 04 nos cable jointing kits
11 KV XLPE Cable Size 3x70 sqmm
11 KV XLPE Cable Size 3x120 sqmm
11 KV XLPE Cable Size 3x185 sqmm
11 KV XLPE Cable Size 3x300 sqmm
Under ground laying of Following cable in Single circuit by drill method to Double pole situated at both sides of NH/SH/Railway Crossing (with HDPE Pipe if required) complete in all respect. Alongwith filling of 04 nos cable jointing kits
11 KV XLPE Cable Size 3x70 sqmm
11 KV XLPE Cable Size 3x120 sqmm
11 KV XLPE Cable Size 3x185 sqmm
11 KV XLPE Cable Size 3x300 sqmm
Hoisting of Following size 11 KV & 33 KV XLPE Cable on double pole with GI pipe of size 6 " dia 4 Mtr long including the jumpering complete with clamps , nut and bolts
11 KV XLPE Cable Size 3x70 sqmm
11 KV XLPE Cable Size 3x120 sqmm
11 KV XLPE Cable Size 3x185 sqmm
11 KV XLPE Cable Size 3x300 sqmm
Supply & Laying of G.I. Pipe at various places i.e road crossing & Hoisting etc. complete in all respect (GI pipe would be Provided by contractor at his own cost)
Supply & Laying of HDPE Pipe at various places i.e road crossing & Hoisting etc. complete in all respect (HDPE pipe would be Provided by contractor at his own cost).
Chemical earthing of T/F & Fencing including all materials (chemical, gi pipe, gi strip, nut bolt, etc)
Earthing of distribution T/F for body & neutral upto water level with GI Pipe of 1.5" Dia. Including GI strip size 35x6 mm. (all material will be supplied by Contractor).
Construction of 250/400 KVA T/F plinth 2x2x1.5 Mtr. for mounting T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect as per UPPCL Norms.
Cage fencing of 250/400 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wire mesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8'(H) by strengthening of wire mesh 20x3 mm M.S. flat horizontally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All manpower, material and T&P provided by the contractor to complete the fabrication, transportation and installation.
The work of digging of pits, erection of Stay Clamp, Insulator etc.
Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms.
Installation of 11 KV Pilfer Proof Metering Cubicle in metering room complete in all respect
Mounting of Following Capacity Transformers as per norms complete in all respect
25 KVA T/F
63 KVA T/F
100 KVA T/F
250 KVA T/F
400 KVA T/F
Fixing of Distribution Box complete in all respect
Guarding at road crossing complete in all respect
Errection & Fixing of Cable box
11 KV Cable Box Size 3x70sqmm
11 KV Cable Box Size 3x120sqmm
11 KV Cable Box Size 3x185sqmm
11 KV Cable Box Size 3x300sqmm
Straight Through 11 KV Cable Box Size 3x70sqmm,3X120sqmm,3x185sqmm)
Cutting of Tree Branch Comming Near Line
Supply & Fixing of Following Items to complete the work (If Not available in stores)
LT Clamps
Nut & Bolt off size
F Clamp as per RESSPO Norms
Shackle Insulator as per RESSPO Norms
X-Arm Holding Clamp as per RESSPO Norms
clamps for top, t-off & other channel etc.
Stay Clamps as per RESSPO Norms
Three Phase Distribution Box Clamp (LS)
Dead End Clamp
Eye Hook
J Hook
LT Shackle Insulator
Barbed Wire
Aluminum Paint
Number Plate
Al. Lugs 70 Sqmm mm
Al. Lugs 150 Sqmm mm
Al. Lugs 240 Sqmm mm
Al. Lugs 400 Sqmm mm
11 KV DO Fuse Set
Garding Angle
Garding Angle Clamp with Nut & Bolt
Suspension Clamp for XLPE Overhead
Danger Board
Stone Pad
Dropper Channel
SMC Fuse Box
Heneley Type Tail less Unit
Safe back carriage of Distribution Transformer from work site to Navada Store approx. distance upto 70 Km including safe loading & unloading.
A.B. Cable Scrap
Iron Scrap
STP Pole Scrap
ACSR Weasel Conductor Scrap
11/0.4 KV 3 Phase 25 KVA T/F
11/0.4 KV 3 Phase 63 KVA T/F
11/0.4 KV 3 Phase 100 KVA T/F
11/0.4 KV 3 Phase 250 KVA T/F
11/0.4 KV 3 Phase 400 KVA T/F
11 KV VCB
Note:-All Item Rate filling with GST by the firm
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.05 MB
Tender_form32.pdf
Tender Documents • 0.86 MB
BOQ_2075811.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid