Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC 121004 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹49.9 L+₹80,930 (1.65%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹50.1 L+₹1.0 L (2.06%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN PARTICULAR CAT D (IV) AND ALSO FAILED TO UPLOAD RELEVANT DOCUMENTS AS PER NIT | |
| 5 | Rejected-Technical 31 CHAIRMAN KARUPPANA THEVAR STEET SULUR COIMBATORE 641 402 | COIMBATORE | TAMIL NADU | 641402 | - | Rejected-Technical NOT ENLISTED IN PARTICULAR CAT D (IV) AND ALSO FAILED TO UPLOAD RELEVANT DOCUMENTS AS PER NIT |
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
9 Sept 2021, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
COMPREHENSIVE REPAIR/ MAINT OF MODERNISED INFRASTRUCTURE INCLUDING CERTAIN MISC WATER SUPPLY WORKS AT AFS SULUR
2021_MES_469614_1
8442/E8
Open Tender
Miscellaneous Works
Item Rate
334 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹1 L
Yes
22 Sept 2021
20 Aug 2021
10 Sept 2021
20 Aug 2021
9 Sept 2021
3 Sept 2021
20 Aug 2021 - 2 Sept 2021
Amount
SCHEDULE A BOQ
Rectification of existing defective flanged joints by replacing new flanged sockets with rubber or fibre gasket complete with necessary nuts, bolts and washers for 150 mm dia GI/DI/MS pipes complete all as directed. Note:- a) The unit quoted rate is inclusive of cutting of GI/DI/MS Pipes, jointing materials and preparation of new flanged sockets and refixing the same at existing place. (b) Necessary excavation shall be measured and paid separately under respective items of BOQ
Excavation for taking out broken CI/DI pipe line upto 200/150mm dia, cutting of CI/DI pipe line upto 200mm dia at two portion with the help of electrical driven pipe cutter and levelling the cutting face of pipe with the electric driven grinder and then CI/DI welding by electric welding machine, fixing detachable joint, tail piece etc then laid on concreteting base with PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete, returning filling of excavated materials including removal of surplus soil complete all as specified.
Opening of existing sluice valve of 200mm bore by dismantling from existing water line and opening of gland cover taking out with spindle with check nut of stainless steel & refixing the same after servicing, greasing including replacement of rubber packing, nuts & bolts, glands etc complete all as specified and directed. Note: Any new parts like stainless steel Spindle with check nuts,Gland plate of required size shall be measured and paid separately as supply only under respective items
Opening of existing sluice valve of 150mm bore by dismantling from existing water line and opening of gland cover taking out with spindle with check nut of stainless steel & refixing the same after servicing, greasing including replacement of rubber packing, nuts & bolts, glands etc complete all as specified and directed Note: Any new parts like stainless steel Spindle with check nuts,Gland plate of required size shall be measured and paid separately as supply only under respective items
Supply only 200 mm bore stainless steel spindle with check nut, gland plate complete all as specified and directed.
Supply only 150 mm bore stainless steel spindle with check nut, gland plate complete all as specified and directed.
Taking down defective centrifugal pump set 40 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after). Make of Pump : BATLIBOI Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000.00 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only split casing gaskets suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed..
Supply only Air cock grease nipple suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.
Cleaning of valve pit chamber for sluice/gate valve of 50/80/100/150/200/ size by removing mud/ grass/ sludge/ other waste materials from the chamber and from surroundings upto 1mtr distance, carryout petty cement repairs with cement mortar 1:4, apply one coat of white wash on cemented surfaces and one coat of synthetic paint on steel surfaces complete to make an operator friendly valve chamber complete as specified and directed. Note :- Periodicity and locations of valve chambers will be given as per requirement by the Engineer-in-Charge.
Rectification of existing defective flanged joints by replacing new flanged sockets with rubber or fibre gasket complete with necessary nuts, bolts and washers for 100 mm dia GI/DI/MS pipes complete all as directed. Note:- a) The unit quoted rate is inclusive of cutting of GI/DI/MS Pipes, jointing materials and preparation of new flanged sockets and refixing the same at existing place. (b) Necessary excavation shall be measured and paid separately under respective items of BOQ
Cleaning/ overhauling of squirrel cage induction motor by dismantling stator and rotor assembly, carryout necessary testing of windings to findout any core loss in windings, test of insulation resistance, etc. Applying of proper insulation material for strengthening of insulation, cleaning the casing and slots with wire brush, washing out dust and carbon particles with proper chemical solution, replacement unserviceable bearing, bush, carryout re-alignment of crank shaft re-assembling stator and rotor assemblies, testing complete all as specified and directed for capacity upto 60 HP. Note:- (i) Rewinding of stator and rotor if required will be measured and paid seperately. (ii) Cost of Transportation to and from the local workshop is deemed to be incl in the quoted rate.
Rewinding of stator core with proper gauge and amount of highly insulated copper wire as existing, testing complete.
Rewinding of rotor core with proper gauge and amount of highly insulated copper wire as existing, testing complete.
M&L for excavation, earth work up to 1 Cum, cutting existing PCC plinth protection of 0.6 Cum for laying/ removing pipes and making good to the disturbed PCC as specified, dismantling existing water supply pipes of any type, re-routing the pipe as directed at site of work by using 3-Layer 32mm outer dia PPR pipe SDR 7.4 ( PN-16 @ 20°C) type connecting both ends to close the pipe line net work, testing during next supply hours of water distribution , complete all as specified and directed by Engr-in-charge. Note:- (i)3-Layer SDR 7.4 ( PN-16) type PP-R pipe 32mm outer dia and additional fittings required for the work will be measured seperately mentioned here-in-below as supply only. (ii) cost of Refixing of disturbed existing pipes on the wall including provision of new clamps are deemed to be incl in the unit quoted rate. (iii) It will be the responsibility of the contractor to arrange all T&P required to execute the job and cost for same will be deemed to be included in the unit quoted rate.
Supply only 32mm outer dia 3 Layer PP-R Polyproplyne random copolymer pipe concealed SDR 7.4 (PN 16 @ 20°C) UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply fixing complete to walls, floors, ceilings, under trenches complete all as specified and directed. Make : SFMC, Prince, KPT
Supply only female threaded elbow suitable for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C) of size 32 mm. Make : SFMC, Prince, KPT
Supply only Male Threaded Adaptor for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C) of size 32 mm. Make : SFMC, Prince, KPT
Supply only female threaded adaptor suitable for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C) of size 32 mm. Make : SFMC, Prince, KPT
Supply only Reducer 63mmx32mm for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C). Make : SFMC, Prince, KPT
Supply only plain union for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C) of size 32 mm. Make : SFMC, Prince, KPT
Supply only female threaded union suitable for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C) of size 32 mm. Make : SFMC, Prince, KPT
Supply only reducing Tee 63mmx32mm for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C). Make : SFMC, Prince, KPT
Supply only Elbow 90 degree for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C) of size 32 mm. Make : SFMC, Prince, KPT
Disconnecting the delivery pipe line of submersible pump sets of any capacity from water mains to take out by lifting column pipe of 50mm dia alongwith submersible cable and pump set from shallow well of any depth for servicing of submersible pump sets of any capacity at site, re-assembling the column pipe and re-connection of submersible cable with pump set and lowering in the shallow/open well, testing and commissioning all as specified and directed. Note:- (a) The cost of tools and equipments reqd for lifting/ lowering of pipes and pumps are deemed to be incl in the quoted rate.
Dismantling pump and motor of submersible pump set for capacity upto 7.5 HP to carry out repairs and replacements at local workshop, duly replacing worn out parts, applying one coat of spray painting with synthetic enamel paint of existing colour and testing complete all as specified and directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only GM Bush.
Supply only SS coupling bearing.
Supply only oil seal thrust bearing.
Supply only Sand Guard.
Supply only sleeve MS key for impeller
Comprehensive repair/ maintenance of modernised infrastructure comprising of the following :- (a) Servicing and repair/ maint/ replacement of defective components /spare parts of PLC based control panels including all accessories modem, antenna etc. installed at various pump houses, OHTs and Master control station for monitoring of water supply.
(b) Repair/maintenance by disconnecting connection for cleaning, lubricating, greasing for wear and tear complete servicing, refixing, lathing installing and commissioning of all motorised, solenoid valves, Pressure Switches, Ultrasonic and magnetic Level sensors etc complete as directed by Engineer-iniCharge.
(c) Servicing and maintenance /repair of defective components of PLC based control panels including all accessories, modem, antenna etc. installed at various locations for the monitoring of street light circuits.
The scope of work also covers the following : (i) Any changes to the Programmable Logic Controller(PLC), e.g. Changes in ladder logic of programme, changes in operational timing, etc. (limited to the scope of items covered under this AMC)
(ii) Any changes to the SCADA software, e.g. Changes in report format, changes in operational screens, creation of soft keys etc. (limited to the scope of items covered under this AMC)
Note for item No 40 :- (a) The comprehenive maint/ repair shall be carried out through the authorised representative of the OEM only.
(b) Cost of labour element towards removing of unserviceable/ defective spare part and re-fixing the serviceable spare part shall be deemed to be included in unit quoted rate. Supply only spare part shall be measured and paid seperately under the relevent item.
(c) Any other spare parts which have not covered in the relevent item given here in below but are required to make system in functional condition deemed to be included in the unit quoted rate.
(d) The unit quoted rate shall be inclusive of One Engineer/ Supervisor per day, Two Technician per day having minimum 05 years experience in SCADA system. Documentary proof of experience of engineer/ technician shall be produced to Enginner-in-Charge before commencement of work. If extra manpower is required for smooth functioning of above mentioned system, rate for same deemed to be inclusive in unit quoted rate.
(e) Service Engineer of OEM or authorised service centre shall visit at least once in every month and during major break down or as and when required for the inspection, servicing, repair, rectification of problem and submission of report.
(f) All the charges for the communications, i.e. 01 Nos broad band connection with static IP at Kalpa Pump House and GPRS enabled data cards used in all PLC based panel related to this scope of work deemed to be inclusive in the quoted unit rate.
(g) SCADA reports related to above mentioned system shall be mailed to Engineer-in-Charge/ concerned JE on weekly basis.
(h) All complaints related to unservicability/ break down of the system shall be attended with in 8 hours, if failed to rectify the system within the stipulated time, a penalty @ Rs. 500 per day will be deducted from the dues of the contractor.
(j) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract.
(k) The decision of the Accepting Officer in this regard shall be final and binding.
Comprehensive repair/ maintenance of modernised infrastructure comprising of the following :- (a) Servicing and repair/ maint/ replacement of defective components /spare parts of PLC based control panels with all accessories modem, antenna complete with electrical connection panel installed at various locations for DG set control and monitoring.
(b) Servicing and repair/ maint/ replacement of defective components /spare parts of PLC based control panels with all accessories modem, antenna complete with electrical connection panel installed at various locations for the monitoring of LT feeders.
(c) Servicing and repair/ maint/ replacement of defective components /spare parts of AMR panel installed at various locations for the monitoring of Energy meters.
(d) Servicing and repair/ maint/ replacement of defective components /spare parts of street lights installed at various locations for the monitoring of Energy meters.
The scope of work also covers the following : (i) Any changes to the Programmable Logic Controller(PLC), e.g. Changes in ladder logic of programme, changes in operational timing, etc. (limited to the scope of work covered under this AMC).
(ii) Any changes to the SCADA software, e.g. Changes in report format, changes in operational screens, creation of soft keys etc. (limited to the scope of work covered under this AMC)
Note for item No 55 :- (a) The comprehenive maint/ repair shall be carried out through the authorised representative of the OEM only.
(b) Cost of labour element towards removing of unserviceable/ defective spare part and re-fixing the serviceable spare part shall be deemed to be included in unit quoted rate. Supply only spare part shall be measured and paid seperately under the relevent item.
(c) Any other spare parts which have not covered in the relevent item given here in below but are required to make in functional condition deemed to be included in the unit quoted rate.
(d) The unit quoted rate shall be inclusive of One Engineer/ Supervisor per day having minimum 05 years experience in SCADA system. Documentary proof of experience of engineer/ technician shall be produced to Enginner-in-Charge before commencement of work. If extra manpower is required for smooth functioning of above mentioned system, rate for same deemed to be inclusive in unit quoted rate.
(e) Service Enginner of OEM or authorised service centre shall visit at least once in every month and during major break down or as and when required for the inspection, servicing, repair, rectification of problem and submission of report.
(f) All the charges for the communications, i.e. 01 Nos broad band connection with static IP at Kalpa Pump House and GPRS enabled data cards used in all PLC based panel related to this scope of work deemed to be inclusive in the quoted unit rate.
(g) SCADA reports related to all above mentioned system shall be mailed to Engineer-in-Charge/ concerned JE on weekly basis.
(h) All complaints related to unservicability/ break down of the system shall be attended with in 8 hours, if failed to rectify the system within the stipulated time, a penalty @ Rs. 500 per day will be deducted from the dues of the contractor.
(j) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract.
(k) The decision of the Accepting Officer in this regard shall be final and binding.
Note for item Srl No 40 & 55 :- (a) The servicing of Motorised valve, PLC base control Panels, communication Panels, shall be done by authorized representative of the Manufacturer only. The technician shall submit a letter from the manufacturer as proof of his being a authorized representative of the manufacturer. The technician shall also submit a signed report on original letter head of the manufacturer that servicing has been carried out by him .
(b) Any changes to the Programmable Logic Controller(PLC), e.g. Changes in ladder logic of programme, changes in operational timing, etc. (limited to the scope of work covered under this AMC) shall be carried out by authorized representative of the Manufacturer (OEM) of PLC based Panels only. The programmer shall submit a letter from the manufacturer as proof of his being an authorized representative of the manufacturer. The programmer shall also submit a signed report on original letter head of the manufacturer (OEM) that servicing has been carried out by him.
(c) Any changes to the SCADA software, e.g. Changes in report format, changes in operational screens, creation of soft keys etc. (limited to the scope of work covered under this AMC) shall be carried out by authorized representative of the Manufacturer of PLC based Panels only. The technician shall submit a letter from the manufacturer as proof of his being a authorized representative of the manufacturer. The technician shall also submit a signed report on original letter head of the manufacturer that servicing has been carried out by him.
Supply only HMI for Programmable Logic Controller having port type 1 x ethernet, 1 x RS 232, 1 x RS422/ 485, 1 x USB port and compatible for supply voltage 24 V DC all as specified and directed. Make :Mitsubishi, Siemens or existing make/brand of defective components/ spare parts or any reputed suitable make as approved by GE.
Supply only I/O module for Programmable Logic Controller having operation voltage range 10.2 to 28.8 V DC, related output voltage 12/ 24 V DC, all modules shall possess a status LED per output complete all as specified and directed. Make :Mitsubishi, Siemens or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply only Pressure switch 0-10 Kg/sqcm having maximum test pressure : 22 bar, maximum working pressure : 17 bar, pressure connection type: G-1/4 male and electric connection size 6-14mm complete all as specified and directed. Make : Danfoss/Indfoss/Rapid Controls or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply only Coil for Solenoid Valve 10 mm suitable for standard 24-110-220-230V/ 50-60 Hz AC, Voltage tolerance : +10% - 5% for DC, +10% - 15% for AC all as specified and asdirected. Make: JOHNSON CONTROLS/ AVCON/ DANFOSS or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by GE.
Supply only SMPS suitable for input 230 V/AC, Output 24V DC, 5A out put current output power 120W, line regulation : 0.5% (full load), load regulation : 1% (230 V AC I/P), operating temparature (°C) : -20 to +70 complete all as specified and directed. Make: NHP/ TELEMEACHNIQUE or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply only Relay 24V DC with base and having Contact configuration 4 PDT, coil voltage 24 V DC, current 6A product range RV serious, relay mounting socket coil type - Latching single coil approval standards LE, LSA, TUV, UL complete all as specified and directed. Make : IDEC/Leone or existing make/brand of defective components/ spare parts or any reputed suitable make as approved GE.
Supply only Magnetic Level switch having contact rating : 10W, switching voltage 24 VDC, switching current : 0.5A, temparature rating - 10/ +85°C complete all as specified and directed. Make: MAHALAXMI/ CRYSTAL or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply only Butterfly valve for 50 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make L&T, AUDCO or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply only single phase Preventor suitable for supply voltage : 100 - 120/ 220 -240/ 380 - 440 V AC + 20% complete all as specified and directed. Make - Minilec or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply only Motorized actuator suitable for 50/ 80/ 100 mm bore of Butterfly valve complete all as specified and directed. Make: Hassel Hoffner/Rotork/ SD Tork/ Emerson or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by GE.
Supply only Hand Wheel for Actuator suitable for 50/80/100 mm dia of Butterfly Valve complete all as specified and directed
Supply only Cast Aluminium Top cover for Actuator suitable for 50/80/100mm dia of Butterfly Valve complete all as specified and directed
Supply only PLC (Programmable Logic Controller) having CPU speed 0.3 micro second for Bool inspection, 0.6 micro second for word instruction with Input power 9.6W complete all as specified and directed. Make :Mitsubishi/SIEMENS/ or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply only Coil for Solenoid Valve 25mm suitable for standard 24-110-220-230V/ 50-60 Hz AC, Voltage tolerance : +10% - 5% for DC, +10% - 15% for AC complete all as specified and as directed. Make: JOHNSON CONTROLS/ AVCON/ DANFOSS or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply only LED Indicator Colour/Red complete all as speicifed and directected. Make TELEMEACHNIQUE/ESBEE/TEKNIC or existing make/brand of defective components/ spare parts or any reputed suitable make as approved by GE.
Supply only Relay 230 V AC with base and having contact configuration 4 PDT, coil voltage 24 VDC, current 6A product range RV serious, relay mounting socket coil type - Latching single coil approval standards LE, LSA, TUV, UL complete all as specified and directed. Make : IDEC/Leone or existing make/brand of defective components/ spare parts or any reputed suitable make as approved by GE.
Supply only Pressure gauge 0-100 Pascal having measuring range : 0-10 Kg/cm², dial size : 100mm connection : 3/8" BSP (M), mounting : Bottom, Dial size : 4 inch, material : casing :MS, internal : brass complete all as specified and directed. Make Fiebag/Manometer or existing make/brand of defective components/spare parts.
Supply only Resistor for Actuator suitable for 50 / 80 / 100 / 150 / 200 mm bore motorized Butterfly Valve complete all as specified and directed
Supply only key pad base HMI having 128 x 64 pixel display, RS 232 or RS 485 USB port TR1 PLC host link protocols for Programmable Logic Controller complete all as specified and directed. Make :Mitsubishi, Siemens or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply only water Level Controller PCB-10 Level suitable for power supply (12-14 V DC) or 16-18 V DC/ 100 MA relay out put : 240V/ 3 A Max complete all as specified and directed. Make: Splash/ICS or existing make/brand of defective components/ spare parts or any reputed suitable make as approved by GE.
Supply only Limit switch with degree of protection IP 67, operating speed 1mm/s to 5m/s for Actuator suitable for 50 / 80 / 100 / 150 / 200 mm dia of motorized Butterfly Valve complete all as specified and directed.
Supply only Butterfly valve for 80 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make L&T or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Electric motor having Output power at running torque : 754W, speed range 15 to 180 rpm, cogging torque 0.9NM, running torque 40NM, peak torque 150NM suitable for actuator of 50/80/100mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make: Ritetork or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply only solenoid Valve 10mm 230V AC suitable for maximum operating pressure (MOP) upto 25 bar with 12W coil Complete all as specified and directed. Make: JOHNSON CONTROLS/ AVCON/ DANFOSS or existing make/ brand of defective components/spare parts or any reputed suitable make as approved by GE
Supply only Capacitor having dielectrical material, polypropylene film, tolerance 5% and rated voltage 240 V AC for Actuator suitable for 50 / 80 / 100 / 150 / 200 mm bore of Motorized Butterfly Valve complete all as specified and directed.
Supply only diesel Level Sensor with 200mm float body length and suitable for 1.5 Amps switching current, 30 Amps carry current complete all as specified and directed.
Supply only water Level Controller PCB-5 Level suitable for Power supply (12-14 VDC) or 16-18 VDC/ 100 MA relay out put : 240V/ 3 A Max complete all as specified and directed. Make: Splash/ICS or existing make/brand of defective components/ spare parts or any reputed suitable make as approved by GE.
Supply only single phase modbus compatible energymeter Module complete all as specified and directed : Make Adept or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply only solenoid Valve 25mm, 230 V AC complete all as specified and directed. Make: JOHNSON CONTROLS/AVCON/ DANFOSS or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply only Butterfly valve for 100 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make L&T, AUDCO or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply, Installation, Testing and Commissioning of GPRS communication Modem along with suitable external antenna, patch chord and mounting accessories as given below including removal of existing unserviceable one:- (i) GSM - Quadband (ii) GPRS - Class 10. (iii) Voice/Data/FAX/SMS facility (iv) TCP/IP - Full ( FTP & E Mail add) Functional Features (i) Input/output Digital -01 (ii) Down load over the air iii) At command set ( GSM 07.05, GSM 07.07 and Wave com)>300 (iv) Auto restore -time reset.
Voice ,Data and SMS Features (i) Data circuit synchronous , transparent and non transparent up to 14,400 bits (ii) Automatic tax group 3 ( class 1 & class 2) (iii) MNP @ V, 42 BIS (iv) Text & PDU SMS (v) Point to point SMS ( MT/MO) (vi) UC S2 character set management
(vii) Din rail mounting (viii) casing- Metal/plastic (ix) Operating status LED INTERFACES (i) SIM Plug in card reader - 1.813 V (ii) PS 232 on 15 Pin Sub.D connector (iii) Pin power supply connector -04 pin DC (iv) SMA Antenna connector Temp Range (i) Operating range - 20+55 degreec/ -25 to 70 degree C (ii) Power supply -5 to 32 V DC (iii) Protection Class-IP 55 (iv) Certification -CE Certification, GCG Certification, ROHS Compliance. (v) Programming /Parameterization 01 modem - Direct. Make: MOTOROLA / VISIONTEK /MAESTRO/ SOLPRO/ MARSH AUTOMATION/ INTEGRATED CONTROL SYSTEM
Supply only 9DB Antenna GPRS Modem complete all as specified and directed
Supply only Temprature Sensor complete all as specified and directed : Make: Existing make/brand of defective components/spare parts or any reputed suitable make and as approved by GE.
Supply and fixing MCCB 4P 63 Amps, 415V, 25 KA with nuts, bolts, washers and suitable size of lugs including taking down existing one complete all as specified and directed. Make : L&T, ABB, Schneider
Supply only LT CTs complete all as specified and directed
Supply only Butterfly valve for 150 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make L&T, AUDCO or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by GE.
Supply only Electric motor suitable for actuator of 150mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make: Ritetork or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by GE.
Supply only Motorized actuator suitable for 150 mm bore of Butterfly valve complete all as specified and directed. Make: Hassel Hoffner/Rotork/ SD Tork/ Emerson or existing make/ brand of defective components/spare parts
Supply only controller for AMF panel compatible for RS 485/ RS 232/ modem/ modubus communication complete all as specified and directed. Make: L&T/Siemens/ EPCOS/ GE
Supply only Butterfly valve for 200 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make L&T, AAUDCO or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply only Electric motor suitable for actuator of 200mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make: Ritetork or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply only motorized actuator suitable for 200mm bore of butterfly valve complete all as specified and directed. Make : Hassel Hoffner/ Rotork/ SD Tork/ Emerson or existing make/ brand of defective components.
Supply only Hand Wheel for Actuator suitable for 150/ 200mm dia of Butterfly Valve complete all as specified and directed
Supply only Cast Aluminium Top cover for Actuator suitable for 150/200mm dia of Butterfly Valve complete all as specified and directed
Comprehensive maintenance of CMDS including operation of CMDS equipments, data collection, assigning of task through concerned JE, updation of feed backs of services carried out, compiling of entries related to MES services from different sources, preparation of daily, weekly, monthly summary of services of different categories, submission of reports to concerned AGEs/GE as per laid down format complete all as directed.
Note for item No 121 :- (a) The contractor shall employ round the clock one operator at CMDS centre having sound knowledge in complaint monitoring disposal system (CMDS) related software/ system.
(b) The operator shall be smart enough to deal with customers of MES regarding registration, lodging, assigning of complaint of user to concerned JEs, updation of jobs/ complaints after carried out by the contractor etc.
(c) Operator is responsible for compilation of user complaints in category wise like E&M, B&R & BS from different sources like manual registers, What'sApp groups, CMDS lodged entries, etc and forwarding of same to the concerned JE's on daily basis.
(d) Operator shall also be responsible to collect the completion/ update of work from concerned contractor/ JE and updation of job status in CMDS system.
(e) The operator shall submit lodged and compliance summary of complaints to the concerned AGE's/ BSO on regular weekly basis or as directed by GE.
(f) The cost of stationary, printer and cartridge required till the completion of the contract shall be deemed to be included in the quoted unit rate .
(g) In case of any failure in functioning of CMDS or task mentioned in above Para (b), (c), (d) & (e), a penalty @ Rs 500/- per day will be deducted from the dues of the Contractor.
(h) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract.
(j) The decision of the Accepting Officer in this regard shall be final and binding.
Supply and fix in repairs power contactor 250 A 4P complete all as specified and directed. Make: Schnider/Siemens/L&T
Excavation in trenches not exceeding 1.5 mtr depth and n exc 1.5 mtr wide and getting out in soft/ loose all as specified and directed
Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25 Cms thick after laying and testing of cable complete all as specified.
Removing of excavated material to a distance not exceeding 50 meter and depositing where directed at level not exceeding 1.5 meter above the starting point complete all as specified and as directed.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge. The rate is deemed to be included.
M&L in replacement cable protection with sub class ‘B’ bricks old size, laid dry, flat over cable perpendicular across the cable in trenches complete all as specified.
Supply and fix 2 core 1.5 sqmm PVC insulated and armoured cable with copper conductor including taking down old unserviceable complete all as specified and directed. Make : POLYCAB/ FINOLEX/ PLAZA
Supply and fixing 4 core 1.5 sqmm PVC insulated and armoured cable with copper conductor including taking down old unserviceable complete all as specified and directed. Make : POLYCAB/ FINOLEX/ PLAZA
Supply and fixing 5 pair 0.5sqmm PVC insulated and armoured communication cable with copper conductor including taking down old unserviceable complete all as specified and directed. Make : POLYCAB/ FINOLEX/ PLAZA
M&L in repairs G.I. tubing light grade 50mm bore for protection of cable under roads, crossings/culverts incl jointing at ends complete all as specified and directed. Make: Prakash Surya/ Jindal/ Tata
Supply and fixing in repairs joint kit complete all as specified and directed. Make : Clip - Seal or existing make/brand of defective components/spare parts or any reputed suitable make as approved by GE.
Supply and fixing 6 core 1.5 sqmm PVC insulated and armoured cable with copper conductor including taking down old unserviceable complete all as specified and directed. Make : POLYCAB/ FINOLEX/ PLAZA
Comprehensive maintenance for SCADA server comprising of the following assets :- (a) HP make CPU, LG make 40” monitor, Key board & mouse- HP make, HP Laser jet printer, DLink broad band modem, DLink Ethernet switch.
Note for item No 143 :- The quoted unit rate deemed to be inclusive of the following :- (i) Repair/ maint of any other hardware installed for monitoring of SCADA system through authorise dealer also covered under this item.
(ii) Necessary software updation, antivirus, upkeep the service etc complete as directed by Engineer-in-Charge for entire contract period will be covered under this item.
Supply and fix in replacement 1 KVA UPS with Maximum configurable (watts) : 800 watts, output frequeny (sync to main) 50 Hz normal input 230V AC, LED status display with indicators complete all as specified and directed. Make : APC/TATA liebert/ Lumnious/ Numeric
Supply only in replacement UPS Battery complete all as specified and directed
Supply and fix in repairs MCB 2P 16Amps complete all as specified and directed
Supply, Installing, Testing and Commissioning of Ultrasonic Level Transmitter Range : 0-5 meters, Accuracy : 0.5 % minimum Supply Voltage : 24V, DC Output : 4-20 MA, Sensor Beam : Ultrasonic, connetion : Flying leads, IP rating : IP67, protected against reverse polarity and transient over voltages including taking down existing unserviceable one complete all as specified and directed. Make: BANNER/NIVELCO/VISIONTEK/MAESTRO/E+H/SIEMENS or existing make/brand of defective components/spare parts.
Supply and fix in repairs MCB 4P 60Amps complete all as specied and directed.
Supply, Installation, Testing and Commissioning of outdoor type power coated PLC (Programmable Logic Controller) based Slave Monitoring / Annunciating Control Panel made out of 1.6mm thick CRCA sheet for control and monitoring of 01 Nos Ultra Sonic Level Sensor, 02 Nos of motorised valves along with provision of arrangement for controlling of one more motorised valve as future expansion including taking out existing unserviceable one:- The panel shall consist of the following equipments; (i) PLC with suitable Digital and analog Inputs / outputs, expansion modules, RTC . (ii) 4" LCD HMI (iii) Transformer with regulated output voltage of 230V +/-5%, (iv) SMPS of Suitable rating (v) Set of Control Relays and suitable MCB (vi) Audio visual generator (vii) Suitable No. of LED Indicators for easy visualisation (viii) Selecetor Swtiches (ix) Push Buttons / Illuminated Push Buttons (x) 0.5 sqmm multistrand internal wiring with ferruling and suitable lugs. (xi) Ethernet Card 6020 (xii) Media Converter (xiii) Ethernet Switch (xiv) LIU(Light Interface Unit)box patch chord and mounting accessories with following specification. Communication: Primary- OFC, Stand by: GPRS Make of Control Panel: RUBIX AUTOMATION / INTEGRATED CONTROL SYSTEMS /MARSH AUTOMATION
Note for item No 151 : The unit quoted rate shall be inclusive of the following :-
(a) The cost of communication for a period of 12 months from the date of completion of work.
(b) Creating additional screens in the existing SCADA system for monitoring and controlling of the motorised valves.
(c) Excavation , earth work , Provision of PCC plinth etc required for instllation of panel
Supply and fixing in repairs 6F HDPE sheathed armoured uni-tube SM optical Fibre cable with central loose tube with jelly compound and high quality electro chromium coated corrugated steel type laid over head on existing available supports all as specified and directed Make : Polycab / Plaza / Havells.
Supply, install, testing and commissioning of outdoor type Factory fabricated GSM controlled motor starter panel suitable for 3 phase 415V, 50Hz system made out of CRCA sheet with suitable neoprene rubber gasket to make it completely, dust and vermin proof, front openable type alongwith locking arrangement having angle iron base frame and legs of suitable size, PCC (1:3:6) bedding for grouting of base including dismantling and taking out old unserviceable panel, complete all as specified and directed. The panel shall comprise the following accessories and specifications :- (a) MCCB 4 pole, 20 Amps, 16 KA - 01 No (Incoming) (b) 3 phase, 415 volt DOL starter suitable for 5 HP motor pump set- 01 Set (c) Motor protection relay - 01 Set (d) Single phase preventor - 01 Set (e) Phase indicating LED lamps RYB - 01 Set (f) Panel mounted multifunction meter including CTs of suitable ratio - 01 Set (g) ON/ OFF push button alongwith indication light - 01 Set (h) Complete control wiring of the panel (j) Earthing terminals - 02 Nos (k) Inbuilt GSM controller cum pump protection device for motor protection and operation of the pump with mobile phone and monitoring the status from anywhere with mobile phone.
GSM controller cum protection device should have the following Specification (A) GENERAL : GSM Controller should have inbuilt Microcontroller and GSM based technology with seven segment display, inbuilt electronic safety for input and output fault.it should have calibrated display for volt meter & amp meter, voice interface with local language along with short message services ( SMS) ,should have push type of sim card tray, with external antenna for high gain of network signal ,it’s control unit should have moulded ABS enclosure. GSM Controller shall be operated in following modes :-. (a) Use switches given on the unit (b) Dial the GSM SIM card inserted in the unit and use voice interactive service (c) By sending SMS to unit to do /set all the parameters.
(C) Monitoring on Display on data logger (a) Calibrated Digital Voltmeter with (b) Calibrated Digital Ammeter (c) On site AUTO FAULT DETECT (AFT) for AC voltage, LEDS, Display, Relay, etc.
(E) Additional Features :- (a) Moulded sticker waterproof high gain antenna for GSM signal reception (b) 4 Digit Password protected operation (c) Facility to check network communication between GSM SIM and dialer phone (d) No call charges when power is absent. (e) Auto call disconnect facility to save call charges (f) Motor ON and OFF switch on unit (g) Switch for Easy bypass and network checking (h) Clock based timers (j) Indication for incoming / Outgoing SMS (k) Indication for Incoming Ring (l) Universal mobile no GSM Compatibility (m) Calibration For Current Measuring Transformers facility (n) Display shows GSM network strength % and also send by SMS to user. (o) SIM Tracking facility (p) Call back facility (q) Auto start unable / disable facility Make : M/s Universal Switchgear & Control, Kewintech, Marsh Automation
Rectification of leakage of GI pipe diameter 80 to 100mm in trench after carry out excavation upto volume of 2 cum, replacement of unserviceable pipe fittings like collar, bend, Tee, Reducer, etc, including threading of existing pipe, applying all necessary engineer effort to check the water leakage, carryout necessary earth works to close the trench and remove surplus soil upto 50 mtr distance all as directed
Rectification of existing defective flanged joints with rubber or fibre gasket complete with necessary nuts, bolts and washers for 80 mm dia GI/DI/MS pipes complete all as directed. Note:- a) quoted rates are inclusive of cutting of GI/DI/MS Pipes, jointing materials and preparation of new flanged sockets and refixing the same at existing place. (b) Necessary excavation shall be measured and paid separately under respective items of BOQ
Making arrangement to flush out the existing pipe line of any type upto 50mm bore and upto 100m length, applying 4.5 N/sqmm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Making arrangement to flush out the existing pipe line of any type 63 to 100 mm bore and upto 100m length, applying 4.5 N/sqmm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Making arrangement to flush out the existing pipe line of any type 110 to 150mm bore and upto 100m length, applying 4.5 N/sqmm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Making arrangement to flush out the existing pipe line of any type 160 to 200 mm bore and upto 100m length, applying 4.5 N/sqmm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Note for item 165 to 168 :- (i) The Contractor is deemed to arrange necessary tools and equipments, removing or alteration of fittings from existing pipe lines, arragement of plugging devices, etc to build up specified pressure required to wash out the pipes. This will be inclusive in quoted rate. (ii) Excavation and earth work required will be measured and paid seperately. (iii) The flushing out will be carried out with fresh filled water of well only duly chlorinated with specified sodium hypochlorite solution to disinfect the pipe lines from all pathogens and Coliform organisms.This will be inclusive in quoted rate.
Recktronic Devices and Systems
pk janardhanan
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .