Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.6 LAccepted-AOC 302 SIDDHIVINAYAK APPT A WING MUMBAI K K MARG JACOB CIRCLE MUMBAI CITY MAHARASHTRA 400 011 | MUMBAI | MAHARASHTRA | 400011 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹52.3 L+₹2.7 L (5.41%)Rejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹52.3 L+₹2.7 L (5.47%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹52.9 L+₹3.3 L (6.74%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | Rejected-Technical | - | Rejected-Technical NO AS PER WLR QE SEP 2021 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
5 Jan 2021, 6:00 pmClosed
GE(NW)BHNADUP
GE(NW)BHNADUP,MUMBAI
REPAIR/REPLACEMENT TO STREET LIGHTS, SECURITY LIGHTS, DG SETS, LT UG CABLES, FEEDER PILLAR BOX, MCCBS AND CONNECTED WORKS AT NCHC POWAI AND ULHASNAGAR UNDER GE (NW) BHANDUP
2020_MES_401451_1
8891/B
Open Tender
Civil Works
Item Rate
270 days
POWAI
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE(NW)BHNADUP
₹96,000
Yes
21 May 2021
7 Dec 2020
7 Jan 2021
7 Dec 2020
5 Jan 2021
22 Dec 2020
Amount
Taking down HPSV / MH street light fitting and Supply and fix LED Street Light Single Piece Pressure Die Cast Aluminium Housing (LM6 Alloy), Minimum 6500 lumens with maximum system wattage 60/65W, external built proper heat sinks and polycarbonate housing ensuring IP66 & IK08 protection, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) 110lumens/watt, Life of System should be 50000hrs@L70 along with inbuilt Potted Driver, CCT 5700, CRI>70, PF >0.95, 4kV surge protection(inbuilt) with optional surge protection of 10kV, Class B servicability, operating voltage of 140-270VAC. The fixture should comply with the parameters as per IS10322 and IEC60598 . Company LOGO shall be Engraved. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters all as specified. Make - Philips/Havells
Taking down HPSV / MH/LED street light fitting and Supply and fix LED Street Light Single Piece Pressure Die Cast Aluminium Housing (LM6 Alloy), Minimum 8200lumens with maximum system wattage 82 W, external built proper heat sinks and polycarbonate housing ensuring IP66 & IK08 protection, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) 110lumens/watt, Life of System should be 50000hrs@L70 along with inbuilt Potted Driver, CCT 5700, CRI>70, PF >0.95, 4kV surge protection(inbuilt) with optional surge protection of 10kV, Class B servicability, operating voltage of 140-270VAC. The fixture should comply with the parameters as per IS10322 and IEC60598 . Company LOGO shall be Engraved. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Make - Philips/Havells
Supply & fix in repairs LED post top lantern fitting 40 watts made out of cast aluminium spigot housing with decorative opal acrylic diffuser and IP65 protection complete.
Taking down unserviceable security light fitting and Supply and fixing LED Street Light Single Piece Pressure Die Cast Aluminium Housing (LM6 Alloy), Minimum 3000 Lumens with maximum system wattage 25W, external built proper heat sinks and polycarbonate housing ensuring IP66 & IK08 protection, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) 120lumens/watt, Life of System should be 50000hrs@L70 along with inbuilt Potted Driver, CCT 5700, CRI>70, PF >0.95, 4kV surge protection(inbuilt) with optional surge protection of 10kV, Class B servicability, operating voltage of 140-270VAC. The fixture should comply with the parameters as per IS10322 and IEC60598 . Company LOGO shall be Engraved. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters including provision of suitable size pipe for bracket of 1.2 mtr complete all as specified. Make - Philips/Havells
Taking down old unsv and supply and drawing through the pole for making connectiion to the light fittings single core PVC insulated and sheathed heavy duty 1100 volt grade multistranded copper conductor (FRLS) cable 2.5 sqmm complete all specified and directed
Taking out existing unserviceable FRP terminal box and S&F mounting type weather proof terminal box of size 150 x 140 x 100 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and backlite connector of 32 A for single phase and neutral (Three terminals) for cable in cable out entire complete. Terminal box to be fixed to wall all as specified and directed
Taking out existing terminal box and S&F Pole mounting type weather proof FRP terminal box of size 250 x 175 x 100 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and aluminium bus bar for single phase and neutral (Three terminals) for cable in cable out entire complete. Terminal box to be fixed to street light pole with suitable G I iron flat of size 25 x 3 mm clamps fixed with GI Bolts, nuts and washer of suitable sizes all as specified and directed
Supply and fixing LED Flood Light with minimum 21000 Lumens (at system level ).The luminaires housing shall be made of non-corrosive high pressure die cast aluminium with corrosion resistant powder coating, MCPCB; U-shaped bracket; Anti-dust exposed Lens, Impact resistance IK 08, IP66, system Power: 175W, Integrated Driver Efficacy:>90%, THD<10%, Life L70@50K Hrs, power factor>0.95; Color temp: 5700K, CRI>70; SDCM<5; The driver shall be BIS registered with outdoor type potted driver. Minimum luminaire efficacy 120 lumen/Watt at system level, operating voltage of 120-270V; Surge protection of 10 KV, lighting distribution options of Narrow/Asymmetrical wide / Symmetrical wide, Class B Serviceability, Electrical safety & Conformation standards of luminaire: The luminaire should have graduation disk for aiming, LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. There should be mandatory coating available for extra protection in harsh environment such as salt atmospheres (harbours, coastal areas etc). BVP483 LED 210 CW complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed
Supply and fixing in repairs 3 pole power contactor 32 amps, coil voltage 230 volts complete all as specified and directed
Supply and fixing in repairs 3 pole power contactor 40 amps, coil voltage 230 volts complete all as specified and directed
Supply and fixing in repairs analog timer switch 3P module, 24 Hrs programme complete all as specified and directed
Supply and fix in repairs pipe bracket made out of 40 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall including necessary clamp/saddle and fixing by screw/bolt complete all as specified and directed.
Supply and fix in repairs pipe bracket made out of 25/35 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall including necessary clamp/saddle and fixing by screw/bolt complete all as specified and directed.
Taking down unserviceable LT cable complete all as specified and directed
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm x 4 core
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm x 4 core
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm x 3.5 core
All as per item No . 17 but of size 95 sqmm x 3.5 core
All as per item No . 17 but of size 120 sqmm x 3.5 core
All as per item No . 17 but of size 70 sqmm x 3.5 core
All as per item No . 17 but of size 25 sqmm x 3.5 core
All as per item No . 17 but of size 10 sqmm x 2 core
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge.
Returning, filling including spreading , leveling , watering and well ramming in layers n.exc 25 cm complete all as specified and as directed by the Engineer-in- Charge
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge
Supplying and laying unreinforced precast concrete cable cover class LV type 1, flat, size 250 x 150 x 40 mm complete all as specified and directed by the Engineer - in - charge.
Supply and spreading sand dust in trenches as cushioning to under ground cable on top and bottom of cable all as specified.
M&L in repairs of GI pipe 80 mm dia light grade with all fittings for cable protection .
M&L in repairs of GI pipe 50 mm dia light grade with all fittings for cable protection .
Supply and fix in repairs of MCCB 100 Amps 4 Pole, with breaking capacity 25 KA complete all as specified and directed.
Supply and fixing in repairs MCCB 4 pole 415V, abjustable type, 50Hz 100 Amps 36 KA with sheet metal enclosure complete all as specified and directed .
S&F in repairs MCCB 100 Amps 3 Pole, fixed type, 415 Volts, 25 KA complete all as specified and directed.
S&F in repairs MCCB 200 Amps 4 Pole, fixed type, 415 Volts, 36 KA complete all as specified and directed.
S&F in repairs MCCB 100 Amps 4 Pole, fixed type, 415 Volts, 25 KA complete all as specified and directed.
S&F in repairs MCCB 63 Amps 4 Pole, fixed type, 415 Volts, 16 KA complete all as specified and directed.
S&F in repairs MCCB 200 Amps 3 Pole, fixed type, 415 Volts, 36 KA complete all as specified and directed.
Supply and fixing in repairs MCCB 250 Amps 4 pole, fixed type, 36 KA, 415 Volts complete all as specified and directed.
M&L for Preparation of old exposed surface of LT steel tubular poles of any type / size with bracktes clamps etc and painting with one coat of aluminium paint upto 6 mtr long and exposed surface of pole yellow and black paint in strips alternative 30 cm wide upto 1.5 mtr from ground level including marking of pole no's with paint all as specified and directed by Engr in Charge
M&L for Preparation of old exposed surface of LT PCC poles of any type / size with bracktes clamps etc and painting with one coat of snomsame paint upto 6 mtr long and exposed surface of pole yellow and black paint in strips alternative 30 cm wide upto 1.5 mtr from ground level including marking of pole no's with paint all as specified and directed by Engr in Charge
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation filling & mass concrete complete all as specified.
M&L for PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in coping of poles including use of form work and finishing all exposed faces of concrete as per clause 4.11.66 (a) & (d) of SSR Part-I complete all as specified.
M&L for Carrying out 'B' check for 82.5 KVA DG set all as per manufacturers instructions all as specified & directed. Note : cost includes the rates of diesel filters only but excluding spares and Engine oil. B Check shall be carried out only OEM.
All as per item No 31. above but 75 KVA capacity
All as per item No 31. above but 50 KVA capacity
All as per item No 31. above but 7.5 KVA capacity
All as per item No 31. above but 160 KVA capacity
Supply only Engine oil grade 20 W 40 for incorporation against item No. 01 Make : Castrol/Servo
Supply only coolant for DG set radiator complete all as specified.
Supply only oil filter suitable for 82.5 KVA DG set capacity as per existing size complete all as specified and diretced, Make- Kirloskar/Mahle/C&G/Leyland
All as per item No 34 above but 75 KVA capacity
All as per item No 34 above but 50 KVA capacity
All as per item No 34 above but 7.5 KVA capacity
All as per item No 34 above but 160 KVA capacity
Supply only of air cleaning filter inner with necessary 'O' rings for the DG sets of existing make and model of capacity of 82.5 KVA DG set
All as per item No 35 above but 75 KVA capacity
All as per item No 35 above but 50 KVA capacity
All as per item No 35 above but 7.5 KVA capacity
All as per item No 35 above but 160 KVA capacity
S&F in repairs of fan belt suitable for DG set of 50 to 160 KVA capacity complete all as specified and directed, Make- FENNER/Roflex/Vegrip
S&F in repairs of fan belt suitable for DG set 7.5 KVA capacity complete all as specified and directed , Make- FENNER/Roflex/Vegrip
Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position of DG set 82.5 KVA
All as per item No 38 above but 75 KVA capacity
All as per item No 38 above but 50 KVA capacity
All as per item No 38 above but 7.5 KVA capacity
Repairing radiator for 82.5 KVA DG set including dismantling from chasses and taking to the workshop for necessary welding / brazing, cleaning work etc including testing for leaks if any , steam washing the radiator and refixing on the chasses complete all as specified and as directed.
All as per item No 39 above but 75 KVA capacity
All as per item No 39 above but 50 KVA capacity
All as per item No 39 above but 7.5 KVA capacity
Material and labour for disconnecting / dismantling of self starter from DG set 82.5 KVA capacity by removing all electrical connections and carrying out to work shop for replacing the defective parts, main shaft, bentex, pinion bearing, DE/CE bush, field coil assembly etc, greasing and connecting , testing complete all as specified and as directed.
All as per item No 40 above but 75 KVA capacity
All as per item No 40 above but 50 KVA capacity
All as per item No 40 above but 7.5 KVA capacity
Material and labour for servicing and overhauling of dynamo including replacement of unsv parts such as carbon brush, armature winding, varnishing of coil and reassembling and fitted with the engine including testing complete of capacity 12 volts complete all as specified and directed.
Material and labour for painting of DG sets of 75 KVA including alternator, fuel tank complete with all accessories by scrapping throughly the existing corroded paint and applying two coats of synthetic enamel paint including marking SM/MES No complete all as specified and directed
Material and labour for painting of DG sets of 7.5 KVA including alternator, fuel tank complete with all accessories by scrapping throughly the existing corroded paint and applying two coats of synthetic enamel paint including marking SM/MES No complete all as specified and directed
Supply and fix in repair unserviceable Maintenance free battery 180 Ah 12 volts complet all as specified and directed. Make Exide/Amron
Supply and fix in repair unserviceable battery lead copper lead with brass terminal complete suitable for DG set 7.5 KVA to 160 KVA all as specified and directed. Make Exide/Amron
Dismantling and calibrating the fuel injector assembly from authorised dealer of capacity 82.5 KVA DG set complete allas specified and directed
All as per item No 46 above but 75 KVA capacity
All as per item No 46 above but 50 KVA capacity
All as per item No 46 above but 7.5 KVA capacity
Material and labour for replacement of asbestos rope 6mm dia complete all as specified and directed
Supply and fixing in repairs electronic based generator controller unit model No GCU101 suitable for 160 KVA generator set including testing complete all as specified and as directed.
M& L for cement concrete type B-1 1:2:4 using 20 mm graded aggregate for road finishing / foundation etc.
Cutting of existing road/PCC for laying of LT cables complete all as specified and directed
Supply and fixing in repair of fire Extinguisher CO 2 type 2 Kg capacity to fixed on wall including fixing bracket complete all as specified and as directed.
Supply and fixing in repairof fire Extinguisher CO 2 type 4.5/5 Kg capacity to fixed on wall including fixing bracket complete all as specified and as directed.
Repairs and overhauling of Air Circuit Breaker (ACB) 3/4 pole, 415 Volt, upto 1200 Amp with thermal magnetic release by replacement of worn out parts and cleaning the complete ACB and testing the same after repair for smooth functioning etc, complete all as specified and directed.
Supply and fix in repair power capacitor bank 10KVAR, 3Ph, 415V all as specified and directed.
Supply and fix in repair power capacitor bank 15KVAR, 3Ph, 415V all as specified and directed.
Supply and fix in repair power capacitor bank 25KVAR, 3Ph, 415V all as specified and directed.
M & L in replacement of Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to galvanized iron strip 32 x 6 mm by means of GI bolts nuts, check nuts and washers etc all as shown in electrical plate No. 3 of SSR part 01 1996 including earth work PCC pit with cover, funnel with watering pipe, wire mesh and GI protection pipe light grade all as specified and directed.
Taking down existing unserviceable burnt out end termination of LT UG cable from LT panel, pole box etc and taking out loop by excavation and repairs the cable by providing aluminium lugs and connecting up by replacing uncerviseable bolts nuts etc complete all as specified and directed of 16 to 35 Sqmm 3.5/4 Core
All as per item no. 58 but of size 50 to 95 Sqmm 3.5 Core
All as per item no. 58 but of size 120 to 150 Sqmm 3.5 Core
Supply and fixing in repairs of multifunction panel meters for panel board of 3 phase, 4W IPM 240 V (L-N) 5 Amps panel mounted digital type meter of size 96mm x 96mm including modification of panel to fix complete all as specified and directed.
S&F in repairs of rubber mat suitable for 433V,of size approx. 2m x 1m x 10mm thick complete all as specified and directed
Material and labour for finding faults (any number in one running length) of LT under ground cables of size upto 185 sqmm by using computerised / primary current injection method /any other method and locating fault .Cutting removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at sitefor the following sizes. Note:-(i) Excavation earth work sand cushioning PCC cover etc will be measured and paid separately under relevant items of schedule here in after.(ii) Cable joint will be measured and paid separately.(iii) Additional length of cable required at site for jointing will be measured and paid separately
M&L for LT straight through joint heat shrinkiable suitable for 3 ½ / 4 core of size 10 to 16 sqmm underground cable all as specified and directed.
All as per item no. 62 but of size 25 to 50 Sqmm
All as per item no. 62 but of size 70 to 120 Sqmm
All as per item no. 62 but of size 150 to 185 Sqmm
M & L in repairs for sub main wiring PVC copper cable 2.5 sqmm (02 Run of 2.5sqmm and 01 Run of 1.5 sqmm) copper conductor 1100 Volt grade multi core multi stranded PVC insulated unsheated drawn through and including PVC conduit and accessories fixing on poles/ wall with clamps, nuts bolts etc from FRP box to street light fiting complete all as specified and direcetd
M&L for preparing surface of existing painting of LT panel board and applying one coat of synthetic enamel paint including to repair hinges /door lock mechanism by necessary welding/ fabrication etc completeall as specified and directed
Deduct Credit for Demolished/ Dismantled material Rs. (-) 197620.00 (Minus) as listed in Schedule of Credit Note: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
R J ENTERPRISES
Radha Engineering Services
GRAND SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .